CertainTeed Corporation
20 Moores Road RECEIVED
Malvern,PA 19355
NOV 2 7 2018
SCOPE:
This NOA is being issued under the applicable rules and regulations go materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: CertainTeed Underlayment Systems
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA# 14-1028.02 and consists of pages 1 through 9.
The submitted documentation was reviewed by Alex Tigera.
--- NOA No.: 17-0306.07
MIAMI•DADECOUNTY Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 1 of 9
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Category: Underlayment
Material: SBS
SCOPE:
This approves CertainTeed Underlayment Systems,as described in this Notice of Acceptance;designed to comply with
the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED By APPLICANT:
Product Dimensions Test Product
Specification Description
WinterGuard HT 36"x 65' ASTM D 1970 Modified fiberglass reinforced,bituminous sheet
Manufuring rolls material for use as an underlayment in sloped roof
Location#1 assemblies. Designed as an ice&rain shield.
WinterGuard Granular 36"x 65' ASTM D 1970 Granular surfaced modified,fiberglass reinforced,
Manufuring rolls bituminous sheet material for use as an
Location #2 underlayment in sloped roof assemblies.
Designed as an ice&rain shield.
WinterGuard Sand 36"x 65' ASTM D 1970 Embedded sand surfaced modified,fiberglass
Manufuring rolls reinforced,bituminous sheet material for use as an
Location#2 underlayment in sloped roof assemblies.
Designed as an ice&rain shield.
Diamond Deck? 48"x 250' ASTM D 226 ynthetic,scrim reinforced underlayment for use
Manufuring rolls Type ll under shake,shingles,slate or metal roofing.
Location#3& 4
e a aymenf' 39 3/8"x 61' ASTMD 1970 A film surfaced,self-adhering underlayment for
Manufuring rolls use under metal roofing.
Location#1 '
Black Diamond" 39 3/8"x 68' 7" ASTM D 1970 Granular surfaced modified,fiberglass reinforced,
Base Sheet rolls bituminous sheet material for use as an
Manufuring underlayment in sloped roof assemblies.
Location #2 Designed as an ice&rain shield.Not for use as
an Anchor Sheet.Direct adhesion to wood deck
not permitted in the HVHZ.
NOA No.: 17-0306.07
Mtar�I•naoecouNTr Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 2 of 9
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Product Dimensions Test Product
Specification Description
Flintlastic GTA 39'/8"x 32' 10" ASTM D 6222 Granule surfaced APP Modified Bitumen
Manufuring rolls Grade G membrane with non-woven polyester mat
Location #1 Type I reinforcement for torch application.
All Weather/Empire 39 3/8"x 65' 10" ASTM D 4601 Asphalt coated fiberglass reinforced base sheet.
Base Sheet rolls Type ll
Manufuring
Location#1
Flintlastic GMS 39-'/g"x 32'10" ASTM D 6164 Granule surfaced SBS Modified Bitumen
Manufuring rolls Grade G membrane with non-woven polyester mat
Location #1 Type I reinforcement for mop application.
Flintlastic SA Cap 39 3/s"x 3Yl 1 TAS 103 Polyester reinforced,self-adhering SBS modified
Manufacturing rolls bitumen cap sheet.
Location #1
Roofers' Select 36"x 144' rolls ASTM D226 An asphalt-impregnated,organic felt reinforced
Manufacturing Type 1 with glass fibers,roofing underlayment.
Location #S
RoofRunner 48"x 250 rolls ASTM D226 Synthetic, scrim reinforced underlayment for use
Manufacturing Type Il under asphalt shingles.
Location#6
MANUFACTURING LOCATION:
1. Little Rock,AR.
2. Shakopee,MN
3. Hangzhou, China
4. Silvassa,India
5. Shreveport,LA
6. Vapi,India
NOA No.: 17-0306.07
MIAMI•DAD;COUNTY Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 3 of 9
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Momentum Technologies,Inc. AX31G8G ASTM D6222 06/05/09
TrinitylERD 3530.12.05-1-RI ASTM D1623 10/05/09
C30280.12.09-R2 ASTM D226 12/11/09
C32240.03.10 ASTM D4977 03/04/10
C30890.03.10-1 ASTM D1970 03/17/10
03500.04.10 TAS 103 04/01/10
C31860.05.10 ASTM D1623 05/18/10
C40050.09.12-2 ASTM D1970 09/28/12
C31410.10.10-R1 ASTM D5147.ASTM D4798 11/02/12
C45240.01.14-1 ASTM D1970,TAS 110 01/15/14
C32930.01.11-R2 ASTM D1623 01/20/14
C45240.01.14-2 TAS 103,TAS 110 01/24/14
CTR-SCI 1145.16-3A ASTM D4601 09/19/16
CTR-SCI 1415.11.16 TAS 103 11/28/16
CTR-SC11505.12.16 ASTM D1623 12/22/16
ACT-SC14110.06.17-1 ASTM D 226 06/29/17
PRI Construction Materials CTC-093-02-01 ASTM D6164,ASTM D4798 08/09/11
Technologies,LLC CTC-163-02-01 ASTM D6757,ASTM D226, 05/09/13
ASTM D4869
InterTek Testing Services Ltd. 10103165000Q-002C ASTM D226 08/13/13
101227796COQ-003C ASTM D4798 08/13/13
10103165000Q-005C ASTM D4869 08/13/13
QAI Laboratories RJ3334-2 ASTM D226 07/07/14
RJ3502-1 ASTM E108 09/29/14
NOA No.: 17-0306.07
MIAMI•DADECOUNTY Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 4 of 9
APPROVED ASSEMBLIES:
Deck Type 1: Wood,Non-insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(1): Anchor sheet mechanically fastened to deck.
Anchor Sheet: (4:12 or Above)One or more plies of Diamond Deck with a minimum 4"headlap and a 6"end
lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge
and in a grid pattern spaced 12" o.c. in the field of the roll.
(2:12 to<4:12)One or more plies of Diamond Deck with a minimum 20"headlap and a 12"
end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap
edge and in a grid pattern spaced 12" o.c. in the field of the roll.Vertical joints should be offset
36"minimum.
Surfacing: Shall be acceptable for use in approved asphaltic shingles,wood shakes,&shingles,quarry
slate, and metal roof applications.Must Comply with applicable Roofing Application Standards
and Building Codes
Deck Type 1: Wood,Non-insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(2): Anchor sheet mechanically fastened to deck.
Anchor Sheet: (4:12 or Above) a single layer of RoofRunner shall be applied with printed side up,parallel to
the eaves, overlapping each course with a minimum 3"headlap and'a 6"end lap mechanically
fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and spaced 15"o.c.
vertically and 12" o.c. horizontally in the field of the roll.
Surfacing: Shall be acceptable for use in approved asphaltic shingle applications.Must Comply with
applicable Roofing Application Standards and Building Codes
• NOA No.: 17-0306.07
MIAMI-DAD;COUNTY Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 5 of 9
Deck Type 1: Wood,Non-insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(3): Anchor sheet mechanically fastened to deck.
Anchor Sheet: (4:12 or Above)Two plies of Roofers' Select with a minimum 2"headlap and a 6"end lap
mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and
in a grid pattern spaced 12"o.c. in the field of the roll.
(2:12 to<4:12)Two plies of Roofers' Select with a minimum 19"headlap and a 12"end lap
mechanically fastened to deck with approved nails and tin caps 6" o.c.at the side lap edge and
in a grid pattern spaced 12" o.c. in the field of the roll. Vertical joints should be offset 72"
minimum.
Surfacing: Shall be acceptable for use in approved asphaltic shingle applications.Must Comply with
applicable Roofing Application Standards and Building Codes
Deck Type 1: Wood,Non-insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(4): Anchor sheet mechanically fastened to deck,membrane adhered.
Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4"headlap and a
6"end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap
edge and in a grid pattern spaced 12" o.c. in the field of the roll.
Membrane: One or more plies of Flintlastic GTA torch applied to anchor sheet or WinterGuard HT,
WinterGuard Granular,WinterGuard Sand,MetaLayment or Black Diamond Base Sheet self-
adhering membrane adhered to the anchor sheet with a minimum 3"headlap.and 6"end lap.
Place the first course of membrane parallel to the eave,rolling the membrane to obtain
maximum contact. Remove the release membrane as the membrane is applied. Vertical
strapping of the membrane is acceptable.If membrane is strapped,then anchor sheet must also
be strapped.
Surfacing: Shall be acceptable for use in approved asphaltic shingles,wood shakes,&shingles,quarry
slate,and metal roof applications.Must Comply with applicable Roofing Application Standards
and Building Codes
NOA No.: 17-0306.07
MIAMI-DAD;COUNTY Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 6 of 9
Deck Type 1: Wood,Non-insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(5): Anchor sheet mechanically fastened to deck,membrane adhered.
Anchor Sheet: One ply of ASTM D 226 Type H organic felt or All Weather/Empire Base mechanically
attached with a minimum 4"side lap and a minimum 6"end lap.Anchor sheet shall be applied
at a right angle(901)) to the slope of the deck with approved annular ring shank nails and tin
caps at a fastener spacing of 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in
the field of the roll of the base sheet.
Ply Sheet: (Optional)One or more plies of an ASTM D226 ply sheet adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
Membrane: One ply of Flintlastic GMS adhered in a full mopping of Type IV asphalt applied within the
EVT range and at a rate of 20-40 lbs./sq. or Flintlastic GTA torch applied to the preceding sheet
or Flintlastic SA Cap,self-adhering membranes adhered to the preceding sheet with a minimum
4 side lap and 6"end lap. Place the first course of membrane parallel to the eave,rolling the
membrane to obtain maximum contact. Remove the release membrane as the membrane is
applied. Vertical strapping of the membrane is acceptable. If membrane is strapped,then
anchor sheet and ply sheet must also be strapped.
When used in Tile roof systems the cap sheet shall be back nailed to deck with approved
annular ring shank nails and tin caps at a maximum of 12"o.c. at the side laps and 6" o.c. at the
end laps. No nails or tin caps shall be exposed.
Surfacing: .Flintlastic SA Cap,Flintlastic GTA and Flintlastic GMS may be used with any approved roof
tile system mechanically fastened as specified in their current NOA.
•Flintlastic SA Cap,Flintlastic GTA and Flintlastic GMS may be used with any approved roof
tile system adhered as specified in their current NOA using any foam adhesive listed and
having a current tile adhesive NOA approval.
Must comply with appropriate Roofing Application Standard RAS 118,RAS 119,RAS 120 and
applicable Building Codes.
LABELING:
All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city,
state and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County
Product Control Seal as shown below.
MIAMI•DADE COUNTY
NOA No.: 17-0306.07
MIAMI-DAD;COUNTY Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 7 of 9
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate
the installation of this material.
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. CertainTeed underlayment roofing systems utilizing Flintlastic GTA, WinterGuard HT, WinterGuard Granular,
WinterGuard Sand, DiamondDeck, MetaLayment or Black Diamond Base Sheet as a cap membrane shall be
acceptable for use in asphaltic shingles, wood shakes, & shingles, quarry slate, and metal roof applications.
CertainTeed underlayment roofing systems utilizing RoofRunner or Roofers' Select shall be acceptable for use in
asphaltic shingles.
3. CertainTeed underlayment roofing systems utilizing Flintlastic SA Cap, Flintlastic GTA or Flintlastic GMS as a
cap membrane shall be acceptable for use in foam adhesive set and mechanically fastened roof tile systems as
specified in the surfacing option of the approved assemblies.
4. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. CertainTeed underlayment roofing systems shall be installed in strict compliance with
applicable Building Code.
5. CertainTeed underlayment roofing systems membranes shall be applied to a smooth, clean and dry surface with
deck free of irregularities.
6. CertainTeed underlayment roofing systems membranes shall not be applied over an existing roof membrane as a
recover system but may be applied over an approved roofing Base/Anchor sheet underlayment.
7. WinterGuard HT, WinterGuard Granular, WinterGuard Sand, Black Diamond Base Sheet, Flintlastic SA Cap,
MetaLayment, Diamond Deck, Flintlastic GMS, and Flintlastic GTA shall not be left exposed as a temporary roof
for longer than 180 days of application. RoofRunner and Roofers' Select shall not be left exposed as a temporary
roof for longer than 30 days after application.
8. CertainTeed underlayment products may be used with any approved roof covering Notice of Acceptance listing
CertainTeed underlayment products as a component part of an assembly in the Notice of Acceptance. If
CertainTeed underlayment products are not listed, a request may be made to the Authority Having Jurisdiction
(AHJ) or Miami-Dade County Product Control for approval provided that appropriate documentation is provided
to detail compatibility of the products,wind uplift resistance,and fire testing results.
9. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels. Sweep
the deck thoroughly to remove any dust and debris prior to application.
10. When applying the membrane in the valley, start at the low point and work to the high point,rolling the membrane
from the center outward in both directions.
11. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to
overlap areas.
12. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance and applicable Building Code.
NOA No.: 17-0306.07
MIAMI•DAD;COUNTY Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 8 of 9
1
13. The maximum roof slope for use as roof tile underlayment for direct-to-deck tile assemblies shall be as follows:
(Limitations noted below are a result of the tile stacking/tile'loading performance and do not reflect to that of the
underlayment. See Table Below)
Tile Profile Flintlastic GMS' Flintlastic SA Cap' Flintlastic GTA'
Flat Tile 4:12 6:12 6:12
Profiled Tile 4:12 5:12 6:12
'The following is applicable to all systems using and Flintlastic GMS:
•Slopes greater than 4:12—Horizontal batten strips are required. Stage tiles touching horizontal battens; a
maximum of 10 tiles shall be stacked parallel to the slope(See Figure 2 below).
2The following is applicable to all systems using Flintlastic SA Cap:
•Slopes up to 5:12,Profiled Tile—Stage by placing two tiles perpendicular to the slope followed by maximum
four tiles on top parallel to the slope for a total of 6 tiles. (Illustrated in Figure 1 below).
eSlopes greater than those shown in the above table—Horizontal batten strips are required. Stage tiles touching
horizontal battens; a maximum of 10 tiles shall be stacked parallel to the slope(See Figure 2 below).
'The following is applicable to all systems using Flintlastic GTA:
•Tiles shall be stored on battens on roof pitches greater than 6:12".
Slope Slope
ji
s
Y a
Side View
Figure 2: Batten Method
Front View
����` « ,<�`�� �°K� Front
Figure 1: Staged Method, View
Figure 2: Batten Method
END OF THIS ACCEPTANCE
NOA No.: 17-0306.07
MIAMI•oAOEeouNTY Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 9 of 9
MIAMIFE
IL
CQiSCTIC0 TROL SEA '-DADE CUNTY
TION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE NOA www.miamidade.aov/eeonomy
CertainTeed Corporation
20 Moores Road NOV 2 7 2018
Malvern,PA 19355
SCOPE: ST.Lucie County, Permitting
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(in Miami-Dade County) and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product
or material tested for quality assurance purposes. if this product or material fails to perform in the accepted manner,the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Ridge Vent 12" Filtered and 9" Filtered
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for
sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA# 15-0831.05 and consists of pages 1 through 4.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 17-0213.07
QMIAMDADERMOUNTY Expiration Date: 06/14/22
Approval Date: 05/11/17
Page 1 of 4
ROOFING COMPONENT APPROVAL
Category Roofing
Sub-Category: Ventilation
Materials: Plastic
Maximum Design Pressure: N/A
Fire Classification: N/A
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Specification Description
CertainTeed Ridge Vent See detail drawing TAS 100 High density polypropylene low profile attic ridge vent
12"Filtered herein for installation in shingle roof systems.
CertainTeed Ridge Vent See detail drawing TAS 100 High density polypropylene low profile attic ridge vent
9"Filtered herein for installation in shingle roof systems
MANUFACTURING LOCATION
1. Orrick,MO
EVIDENCE SUBMITTED:
Test Agency/Identifier Name Re ort Date
Architectural Testing,Inc. TAS 100A(95) 6457.01-109-18 08/08/06
TAS 100A(95) 65453.01-109-18 08/08/06
PRI Construction Materials Technologies ASTM G 155 AVIG-006-02-01 10/18/11
ASTM G 1929 AVIG-005-02-01 10/18/11
ASTM D 635 AVIG-005-02-01 10/18/11
ASTM D 2843 AVIG-005-02-01 10/18/11
NOA No.: 17-0213.07
MIAMI•DAD,COUNTY mj Expiration Date: -0214/22
Approval Date: 05/11/17
Page 2 of 4
APPROVED APPLICATIONS:
Tradename: CertainTeed Ridge Vent 12"Filtered, and
CertainTeed Ridge Vent 9"Filtered
System Type: Mechanical attachment of static vent over asphalt shingle roof systems only.
Slot: Cut a minimum 1'/z" slot along the apex of the roof by cutting'/4"on each side of the ridge.
The slot shall terminate approximately 6" from the rake edge.
Installation: Place ridge vent section centered over the void at one end of the ridge.Plugged end should
be flush with end wall of ventilated space under roof. Pre-fasten first section using roofing
nails through pre-drilled nail bosses. Continue to pre-fasten remaining sections,making
sure support walls are flat on roof and filter is secure between shingles and vent. Cut final
section to length.
Ridge Shingle: Nail cap shingles in place using roofing nails long enough to penetrate through the roof
sheathing a minimum of YIh of an inch. Use nail lines provided on vent.
Net Free Area: Refer to manufacturers published literature.
Minimum Slope: 2:12
LIMITATIONS:
1. Refer to applicable Building Codes for required ventilation.
2. This acceptance is for installations over asphalt shingle roof systems only.
3. CertainTeed Ridge Vent 12"Filtered,and CertainTeed Ridge Vent 9"Filtered Ridge Vents shall not be installed
on roof mean heights greater than 33 feet.
4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
5. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo and following statement: "Miami-Dade County Product Control Approved" or the
Miami-Dade County Product Control Seal as shown below.
MIAMI•DADE COUNTY
• '
NOA No.: 17-0213.07
MIAMI•DADE COUNTY Expiration Date: 06/14/22
Approval Date: 05/11/17
Page 3 of 4
`c w
DETAIL DRAWINGS
11.0
R4.9
t
4Q° '—1
2.5 ,.
s .
.4
iss
CERTAINTEED RIDGE VENT— 12" FILTERED
e
y I
(�1
�s.5.
5.2
CERTAINTEED RIDGE VENT—911 FILTERED
END OF THIS ACCEPTANCE
NOA No.: 17-0213.07
MIAMI•DADE COUNTY Expiration Date: 06/14/22
Approval Date: 05/11/17