Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2 _711 ia k r a: amu, eCIS Home Log In ! User•Registration ! Hot Topics Submit Surcharge f Stats&Facts I'rPdbncauoas�!-Contact Us I I aC75 Site Map j Links Search, Pbridd '`Product Approval USER:Public User ,q A 1 L,I s sn V _ `• Product Aooroval Menu>product or Aoollcatlon Search>Application List>Application Detail �• � FL# FL19715-R4 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Silver Line Building Products Corp. Address/Phone/Email One Silverline Drive North Brunswick,NJ 08902 (732)435-1000 jonberrian@slbp.com Authorized Signature Jon Berrian jonberrian@slbp.com Technical Representative Jon Berrian Address/Phone/Email One Silverline Drive North Brunswick,NJ 08902 (732)435-1000 jonberrian@slbp.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Hermes F.Norero,P.E. the Evaluation Report Florida License PE-73778 Quality Assurance Entity Window and Door Manufacturers Association-QA Quality Assurance Contract Expiration Date 12/31/2019 Validated By Locke Bowden P.E. FA Validation Checklist-Hardcopy Received Certificate of Independence FL19715 R4 COI COI Silverline SS 2017-06-14 odf Referenced Standard and Year-(of Standard) Standard year AAMA/WDMA/CSA 101/I.S.2/A440 2011 AAMA/WDMA/CSA 101/I.S.2/A440 2008 ASTM E1886 2005 ASTM E1996 2012 ASTM E330 2002 TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By https:Hfloridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtvA`/`2bxmzkl hGu... 11/27/2018 Florida Building Code Online Page 2 of 2 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 12/18/2017 Date Validated 12/18/2017 Date Pending FBC Approval 12/29/2017 Date Approved 02/13/2018 Summary of Products FL# Model,Number or Name Description 19715.1 Series 2900/4900 Single Hung Extruded Vinyl Single Hung Window Limits of Use Installation Instructions Approved for use in HVHZ:No FL19715 R4 II SWD002 SS 2017-12-15 Ddf Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero,P.E. Florida P.E.73778 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See Installations Instructions and Product Evaluation FL19715 R4 AE PER5375 SS 2017-12-15.Ddf Report for design pressure tables and limitations of use. Created by Independent Third Party:Yes 19715.2 Series 2900/4900 Single Hung Extruded Vinyl Single Hung Window Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL19715 R4 11 SWD012 SS 2017-12-15.Ddf Approved for use outside HVHZ:Yes Verified By: Hermes F.Norero Florida P.E.73778 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See Installations Instructions and Product Evaluation FL19715 R4 AE PER5376 SS 2017-12-15.odf Report for design pressure tables and limitations of use. Created by Independent Third Party:Yes 19715.3 Series 70 Model 2127 Single Hung Extruded Vinyl Single Hung Window Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL19715 R4 II SWD010 SS 2017-12-18.Ddf Approved for use outside HVHZ:Yes Verified By: Hermes F.Norero Florida P.E.73778 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See Installations Instructions and Product Evaluation FL19715 R4 AE PER4805 SS 2017-12-18.01' Report for design pressure tables and limitations of use. Created by Independent Third Parry:Yes 19715.4 Series 70 Model 2127 Single Hung Extruded Vinyl Single Hung Window Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL19715 R4 II SWD011 SS 2017-12-18 Ddf Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero Florida P.E.73778 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See Installations Instructions and Product Evaluation FL19715 R4 AE PER4806 SS 2017-12-18.Ddf Report for design pressure tables and limitations of use. Created by Independent Third Party:Yes Back NeM Contact Us::7601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007.2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click hem. Product Approval Accepts: Credit Card': https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtvA%2bxmzk lhGu... 11/27/2018 I Suver Line SILVER ' LINE BUILDING PRODUCTS V1 SERIES170 SERIES SINGLE HUNG WINDOW (2127) No ONE SIIRTHU �w a902 PH:f8001 3344228 (NON-IMPACT) J z z� w0 F QQ O z azw ZS g3a v%i 3 Gz O 3d8 GENERAL NOTES: w j z 0 m It3 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MAX OVERALL SIZE TABLE OF CONTENTS > o \a l/ MANUFACTURED TO COMPLY WITH THE 6TH EDITION CONFIG. DESIGN MISSILE ET < FLORIDA BUILDING CODE(FBC),INCLUDING HVHZAND HAS WIDTH HEIGHT PRESSURE IMPACTRATING SHEREVISION SHEET DESCRIPTION w \ BEEN EVALUATED ACCORDING TO THE FOLLOWING: • TAS 20234 52" 62.50" O/X +62.8/-65 PSF NON IMPACT 1 - GENERAL NOTES&GLAZING DETAIL • ASTM E330-02 REMARKS BY DATE • AAMA/WDMA/CSA101/I.S.2/A44G-08/11 2 - ELEVATION&ANCHOR LAYOUTS 6rHFBCEDMON ua D6/24/v 52" 73" 0/X +55/-60 PSF NONIMPACT - 2. ADEQUACY OF THE EXISTING STRUCTURAL 3 VERTICAL SECTIONS CONCRETE/MASONRY,2X FRAMING,AND METALFRAMING 4 - HORIZONTAL SECTIONS AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRINGAPPLIED PRODUCT HORIZONTAL&VERTICAL SECTIONS,INSTALLATION NOTES& . 5 - DETAILS LOADS TO THE FOUNDATION I5 THE RESPONSIBILITY Of THE REINFORCEMENTvMovuuxm4E uvRovucEo M xmou ruvuir ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF wmromN7 0T8E NiMDDU=M MW M11. AIIEMnONS,ADdnONS,XIGHLIGMDNG,OR OTHER INSTALLATION. wunNssronas ooaeArNrAu xmvERNnrzDANP u0 3. 1X AND 2X BUCKS(WHEN USED)SHALL BE DESIGNED AND Digitally signed byy yyujr//gqe,�F.Norero,P.E ANCHORED AS SPECIFIED HEREIN.REFER TO SHEET 5 FOR Reason:l Ii�p�o4in-4 RAlAsgyent FURTHER DETAILS OF BUCK INSTALLATION. Date:2 .856: �5170v = 5/8"O.A.I.G.GLASS `2 �l �i�� 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE R GENERIC AND MAY NOT REFLECTACTUAL CONDITIONS FOR I ,Z':• Q ASPECIFICSITE.IF SITE CONDITIONS CAUSE INSTALLATION i — ] __ TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE -.0;3 T T t SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT IN \ INTERIOR NON-HVHZ AREAS.IN HVHZ AREAS,ONE TIME PRODUCT EXTERIOR / + O•••• pP;' <U� APPROVAL TO BE OBTAINED FROM MIAMI-DADE RER OR I i��T�s••••.,,,..••' G��*- AHI. I �IMF �i��s/ONAL������� S. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED ON STEEL SPACER ` Nt7a�db1II&w"ps THIS PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE. FLOMDA PM No 77778 MIN.GLASS MMDNO drops INC 1/8"OR 3/32" Soe o —A M M!I"NI /778 6. WINDOW FRAME MATERIAL:PVC BITE 7/16" EaPE OERI.OF At�ir OFM711ON No.2o67e SETTING BLOCK 7. IN ACCORDANCE WITH THE 6TH EDITION FOC,WOOD . FL q: COMPONENTS SHALL HAVE BEEN PRESERVATIVE TREATED F L 19 715 OR SHALL BE OF A DURABLE SPECIES AS DEFINED IN CHAPTER 23. GLAZING DETAIL DATE: 12.11.17 8. GLASS MEETS THE REQUIREMENTS OF ASTM E 1300 DWG.BY: CHK.BY: GLASS CHARTS.SEE SHEET 5 FOR GLAZING DETAILS. NOTE: LMS 1HFN ALL GLAZING CONFIGURATIONS SHALL COMPLY WITH SCALE: NTS SAFETY GLAZING REQUIREMENTS OUTLINED IN SWDOIO CURRENT FBC AND ASTM E 1300 GLASS LOAD DWG,4: RESISTANCE. SHEET: OF 5 � Silver Line KO'ATIdei%6 ONE SILVERUNE DRIVE NORTH BRUNSWICK,NI 08902 PH:(8001 234J 28 MAX.O.A FRAME J' z WIDTH 52" Z F MAX.D.L.O. ui n a E WIDTH 47.69" W z zQ,13a A B 3"MAX. 6"MAX. 6.25"MAX. I p F Ur S ��A --- 3 3 FROM I O.C. FROM oz < z s r 3 CORNERS I r CORNERS I J o mi tD W cc w z DO NOTE: ALL FASTEMEETING > a /a THE MEETING RAIL IN •• c\ O THE INTERIOR JAMB C MAX.D.L.O. 4 ^O" 6"MAX. TRACK MUST BE FLATHEADS. r . a HEIGHT33.50" C O.C. REMARKS BY I DATE 4 6THEBCEDRION LM 06/11/17 12.50"MAX. O.C. MAX.O.A FRAME HEIGHT 73" "WIrx ro Arm sxAu Nm e E uvxo9u¢D m ux+0K2 DR vAxr wmlDmwNTr[x mxsExr DrNmwxa 9Rws,Nc uTDunaa,A9 dmxs,Hlow6xnxy on mxu MMDNGSTOTILLf WNMEMAR[N.1 FAAVRFDAND ..X.. 3"MAX. 6.25"MAX. E e HEIGHT 33.50" FROMFROM CORNERS CORNERS `,Lllll111JJ//// X S F.Ll� •........ .O ELEVATION ANCHOR LAYOUT ANCHOR LAYOUToP.: SINGLE HUNG WINDOW NAIL FIN-SINGLE HUNG WINDOW THROUGH FRAME-SINGLE HUNG WINDOW i ••••........ •' . ���isS�lO.NAI FBINE�T}WQI PE 'S now PE N.73778 BUILDING DROPS NO 398 E OAIBA BEACN BLTA 3JB g DAWA BEADH.EL I WE CERT.OF AU1HOfRAnON Nw 20378 ffi FL p: FL19715 DATE: 12.11.17 4 DWG.BY: CHK.BY: LMS I HFN z SCALE: NTS i DWG.#: SWD010 SHEET: 2 OF 5 a Sil�� I NORTH ONE AVERME DRIVE BRUNSWICK Nl O8907 FFyye� PH:800 73"228 yy \ J Z R / Vi t Wo SEE GLAZING SEE GLAZING DETAIL,SHEEP 1 DETAIL,SHEET 1 _d t!f J MZ w w m 0 r o. REMARKS BY DATE _ 241�, W 61HFBCEDMON LM 06/1//17 I9 11 i2 2 x EXTERIOR INTERIOR EXTERIOR INTERIOR Il W NNGsuLLIP)T6LPLPPDBUCLDIN WNOBid PMT WI1110UT WPIFiEN CGNSFMf DFBGItdNG DIIOPS.dC NUFMTIGN;AGDRIONS.XK.IN1GNfIN0.0POMFA c NYRAIfG5IIWAUCA EOVACNPLN TJQN.iRiL4ANe SEE GLAZING SEE GLAZING a . 7T rcr - DETAIL,SHEET 1 DETAIL,SHEET 1 NNAL-..,% L fxD�41#LRD 73M FU*WA O O xo 7377E / 1 6UNIA omP6 we Yt we O" BFaG/BIW./308 FBPE OW W F6VTHaPo7FlAn17�0ox{>7se7e *IRFL M "7 FL19715 DATE: 12,11.17 DWG. I "HFN SCALE: NTS f DWG.#: SWD010 4 A VERTICAL SECTION g VERTICAL SECTION SHEET: OF 5 glvg�.k,29 dr r ONE SE MINE DRAM INTERIOR NORTH BRUN'swim N108902 SECTION FOR SECTION FOR PH:900 BLOCK&TACKL BALANCERSE SEE GLAZING SEE GLAZING —CONSTANT FORCE V DETAIL SHEET I DETAILSHEET BALANCERS Z Z lim it It 9z z 1101i EXTERIOR5 E 0 DO D.L.O. MAX.FRAME WIDTH REMARKS BY DATE HORIZONTAL SECTION 6THFOCEDnMN LAI 06/14/27 UPPER SASH ftPRDD=G.�ORPAAr N. SEE GLAZING INTERIOR SEE GLAZING —\ % CETAI L SHEET 1 DETAIL SHEET 1 ..... IlrOrlrrrr .. .0s rfrrrriJs EXTERIOR s'/0 ua'FLORDA PM No D.LO, EARLDWO DROP-% sca L DANA REACH W DANIA . N —kyMUM MT.OFAMUMTHDRNo.29579 MAX.FRAME WIDTH FL#: FL19715 HORIZONTAL SECTION DATE: 12.11.17 LOWER SASH DWG.BY: CHK.BY: LMS I HFN SCALE: NTS DWG.#: SWD010- SHEET., OF 5 � MIN. SUBSTRATE 1/4"MAX. $HIM SPACE �� SUBSTRATE MIN.EMBEDMENT SUBSTRATE 5ilverL ne EDGE DISTANCE BY OTHERS 3 BY OTHERS .� 8Y OTHERS 1aAnFlelse11 INTERIOR SCREW IN THE INTERIOR CHANNEL It MIN. Lu MIN. EDGE DISTANCE u ONESTIWRUNFD&AE EMBEDMENT SCREW IN THE EXTERIOR oz NORTH BRUNSWICK w a PH:(800x3aoxxe CHANNEL z�, PERIMETER SEALANT I� —� 1/4"MAX LLl 0 2 a E ! PERIMETER SEALANT L�,� BY OTHERS SHIM SPACE 1/4"MAX. z f I N Nl`n BY OTHERS Q EXTERIOR MIN. SHIM SPACE 0.0 EXTERIOR INTERIOR EMBEDMENT EXTERIOR INTERIOR x s �0Fa� L9IIR VERTICAL SECTION HORIZONTAL SECTION C Z'~� s E A HORIZONTAL SECTION w a o o THROUGH FRAME(HEAD) 6 THROUGH FRAME(JAMB) 6 NAIL FIN(HEAD) x z �z m& NS N?C m REINFORCEMENT DETAILS ' x 1/4"MAX. �+—0.34" W SUBSTRA SHIM SPACE I d BY OTHERS 0.87" INTERIOR 2 �—.( 8� -+X0.13" REMARKS BY DATE 1- 0 77" 6TH FB[EDITION LM 06/14/17 w T ` �� 0.415 w=f 0.06" 0.87" 0.46.. z 0.9 o EXTERIOR INTERIOR , 1 NUMOP C2 LOCK MEETING RAIL ALL TTOM LIFT MIINUM RAIL$c SASH LOCK ALUMINUM Ax°sxuLxore6 wnwuaulxwxoL6oa rARr 7EXTERIOR MMCtNG5T6NM6xWNMURAax[}TPE°P5aD6PAx° AITFMSpIi;AUDITION;XILNt1G!°°t°.°R°MFA MIN.EDGE DISTANCEF ,111ttI.JJJJJJ p HORIZONTAL SECTION E VERTICAL SECTION 6 NAILFIN(JAMB) 6 MEETING STILE �� orfr INSTALLATION NOTES: ANCHOR SCHEDULE * 7 .. -* SCHEDULE MON EE43EOMENT MI i. ONE(I)INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN. METHOD SUBSTRATE ANCHORDISTAN.EDGENCE as^O T T 2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OF ANCHORS TO BE USED FOR PRODUCT WOOD:MDi.SD=0.55 OO #aWOODHEAD EW t.6• 0.76` ;r Q�ti ( pP;••�+>;�'.� DSCR ,. INSTALLATION OF THE MAXIMUM SIZE LISTED. NAILING FIN .•••• METALIMIN�FyGAUG08 TEK SCREW PENE BEYOND 050' rt�'i�sSfpNA1:.E�fr���`` 3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN A TOLERANCE OF 31/2INCH THE DEPICTED LOCATION&SPACING IN THE SSIW. METAL ANCHOR LAYOUT DETAILS(I.E.,WITHOUT CONSIDERATION OF TOLERANCES).TOLERANCES ARE NOT CUMULATIVE FROM ONE FLORID 4f N.73 73 INSTALLATION ANCHOR TO THE NEXT. P10 PAN HEAD IN FLORIDA ME Nn we 1.6' 0.76' BU14N4 oR4P&OIC EXTERIOR CHANNEL 3Y6 E DAlUA BEAOf 8WR i 376 2 4. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S).MAXIMUM ALLOWABLE SHIM STACK TO BE WOOD:MIN.SG=0.55 FBPC QALLOF Ai IOR6ATION xw Zos79 6 YO FLAT HEAD INTHE 3/8 INCH.OR BETTER.HIM WHERE SPACE OF 1/16 INCH OR GREATER OCCURS.SHIM(5)SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC INFERIOR CHANNEL is 4sb• FL N: S. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES,INCLUDING BUT NOT LIMITED TO STUCCO,FOAM,BRICK a10PANHEADIN PENETRRATION 7TATION BEYOND 0.54 MIN FL1971"J g' VENEER,AND SIDING. METAL-18 GAUGE SWW. EXTERIOR CHANNEL THROUGH FRAME METAL DATE:MIN.Fjr=33KSi 12.11.17 6. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL ORHAVE A 010 FLAT HEM IN THE 3THREADSMIN DWG.BY: CHK.BY. CORROSION RESISTANT COATING. INTERIOR CHANNEL ENETRATION META Evle HBEYOND 4s4•CORROSION LMS METAL .a n 7. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK,DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS.EDGE coNCRETe Frr34wPE1 art�T T�APCON t.zs t.7s SCALE: NTS DISTANCE IS MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK, S W DO10 DWG.k: 8, INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, MAsoNRv:GMv Per 3IIS'17W TAPCON 1 zs• 1 T5^ SHEET: AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BY THE C90 MIN.2040 PEI FLAT HEM ANCHOR MANUFACTURER. 9. FOR INSTALLATION ANCHORS ABOVE THE MEETING RAIL IN THE INTERIOR JAMB TRACK,USE FLATHEAD ANCHORS. OF 5 to 24 14 24 PAMAL 31DI 31 7 BAS 17 1164 ) 17 2 , GAA (Qs 2.4 17 10