HomeMy WebLinkAboutProduct Approval (3) 1/1312018 Florida Building Code Online V
BCtS Home Log in. { User Registration Hot Topics ! Submit Surcharges stats&;Facts ( Publications ' FBG.Staff lA BGS Ste MapY i Unks € +Search
F7 rda
Product.Approval
USER:Public User
Product Aoproval Menu>Product or Application Search>Application Us >Application Detail
< r a FL L17647-R1L /7&q7, 2
_ � �+
Application Type -Revision
Code Version 017
Application Status Approved
Comments
Archived
Product Manufacturer Custom Window Systems Inc.
Address/Phone/Email 1900 SW 44th Avenue
Ocala,FL 34474
(352)368-6922 Ext-245
kpine@cws.cc
Authorized Signature Kevin Pine
kpine@cws.cc
Technical Representative Jay Lathrop0 I
Address/Phone/Email 1900 SW 44th Ave
Ocala;FL 34474
(352)368-6922 Ext 291
jlathrop@cws.cc
Quality Assurance Representative Arturo Monteverde
Uj Address/Phone/Email 1900 SW-44th Ave
Ocala,FL 34474
(352)368-6922 Ext 221
amonteverde@cws.cc
LL Category Windows
Subcategory Single Hun
l
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received {
ss
Florida Engineer or Architect Name who developed Luras A.Turner
the Evaluation Report
Florida License PE-58201
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration date 07/21/2020
Validated By Steven M.Urich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL17647 R1 COI EvaiReport882B.pd 4'
Referenced Standard and Year(of.Standard) Standard Year
AAMA/WDMA/CSA 101/I.S.2/A440-08 2008
ASTM E1886-05 2005
ASTM E1996-09 2009
TA 201/202/203 1994
Equivalence of Product Standards
Certified By
hfpsl/www.flaridabuilding.org/pr/pr_ppp dtl.aspx?param=wGEVXQvADgvFGYZsjrZFR9F38JUJ4XSP%2fpCG2rt44EaVhMhWp/*2bDNN4gg%3d*/*3d 1/2
1/13/2018 Florida Building Code Online
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 09/28/2017
Date Validated 09/29/2017
Date Pending FBC Approval 10/02/2017
Date Approved 12/12/2017
Summary of Products
FL# Model,Number or Name Descrlption '
_......_.e._.._...___
17647.1 SH-8100 SH-8100 PVC Single Hung
Limits of Use ((Installation Instructions
Approved for use in HVHZ:Yes FL17647 RI IT CWS-958B_pdf
Approved for use outside HVHZ:Yes Verified By:Lucas A.Turner 58201
Impact Resistant.,Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See installation detail for sizes and Dias.Outer lite I.G. FL17647 RI AE EvalReport958B.Ddf
to be safety glass when used above 30 ft,in HVHZ.Glass Created by Independent Third Party:Yes q
complies to ASTM E1300-044 i
17647.2 _ SH-8100 SH-8100.PVC Single Hung
Limits of Use :Installation Instructions
Approved for use in HVHZ:Yes FL17647 R1 11 CWS-882B.odf
Approved for use outside HVHZ:Yes Verified By:Luras A.Turner 58201
II Impact Resistant:Yes Created by Independent Third Party:Yes
i Design Pressure:+70/-70 t Evaluation Reports
Other:Flange only,Max,size 51-7/8"x 72".Outer lite I.G.to FL17647 Rl AE EvalReoort882B.Ddf
be safety glass when used above 30 ft.in HVHZ.Glass Created by Independent Third Party:Yes
complies to ASTM E 1300-04.
. _ ___j
Falk rtex4
F
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850.487.1824
3
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State'of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records,if you do not wantyour e-mail address released In response to a public-records request,do not send electronic. it
mail to this entity,Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section is
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may he used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal
address,please provide the Department with an email address which can be made available to the public.To determine,if you are a licensee under Chapter455,FS., �
please click h re.
Product Approval Accepts: r.
i
4(
Credit Card
Safe
x
;i
https:lfwww.floridabuilding.org/pr/praPP_ tl.aspx? aram=wGEVXQwtD vFGYZsjrZFR9F38JUJ4X8P°/a2fPCG2n44EaVhMhW%2bDNN4q9%3d%3d 2/2
WIN�Y'"T"EUUf95�(k".7j1
1900$VV 44TH AVE.
OCALA,FLORIDA 34474
`r
WWW.CWS.CC 3
8100 PVC
SINGLE HUNG
IMPACT
i s
awa
Z � Sz00�
i zdz w
.•....
--y- 0. E�O-'a.
118`ANNEALED OR TEMPERED VV ANNEALED OR TENIPEREO ZxL gam'tIIs
¢%u}p O
j 7116'AIRSPACE ---7116"AIRSPACE V N t j Oz a~N a
Z _pOt�j tli23UVi
•• -6116`LAMINATED 5116'LAMINATED
I IW ANNEALED .116'ANNEALED Q _ O.
1 ---1118'DUPONT PVS INTERLAYER ; 094'DUPONT PVB INTERLAYER a Z 0 O N
118'ANNEALED --'118'ANNEALEDp W Q p,5 7
Iu 7r W stx
I, i- it
SIKAFLEX 652 OR ptArryr
QUANEXDLIRASEAI PURFEGTGLAZE"H' GUSPACERURA"uEAt (4.1')P RFESIK&FLCTGU+2E'N' ',`tp.NORE4y1Tr�f{ 4
552 OR
IG SPACER 1_ Q.y.'i� 1
1 14 ' 172"GLASS SITE *; Na 58201
i
SASH LITE h�,
FIXED LITE
.—X12712617
€ LUCAS A.TURNER.P.E.
FL PE#58201
1239 JABARA AVE.
NORTH PORT,FL 34288
PH.841-380-1574
' Sf1EETU&Gp,7P�lON'; '••-
GLAZING DETAILS
ADE 01116114
REV
SETTING BLOCKS PER FOC 2411.3.3.1 CWS-882 B
s SHEET
.... ._........�._....... _....�_ _. _ _ � _ _..__._� __..._.
1:1 2 OF 6
WIN:0OW SYSTEMS �1
3NTERtOR 1900 SW 44TH AVE.
j 1 OCALA,FLORIDA 34474
13 3'` �,r"4 °•46} WV.Mt,GWS.CC_. _
8100 PVC
T7m SINGLE HUNG
IMPACT
ini
t
LL
{3x 3 14a C Wit'
SECTION B-8 Z�j�z �laf
fluty rfiy�fl'
NOTE:LEFT SIDE SHOWS FIXED SECTION VIEW,
RIGHT SIDE SHOWS SASH SECTION VIEW, O v O
z
I"o _ 0wuaDwo w
r0
Kt 5- w05i .
3 3) C+ Titx a wt�t3�
CL
32 INTERIOR ``�OPrytON5F4y+'�
/ ..-.� v:• Na 58201 '�"A:.
S J B 'r• k •"�"
fi
jpiloty
t4,
s
siaz/2a17._.....
1 e 6} �AS A_TURNER,P.E. l
FL PE#58201
_ 1 1233 JABARA AVE.
B` NORTH PORT,FL 34288
PH,941380.1574
FET EI)so2iAII6N: '-
SECTION VIEWS
SECTION A-A
pitAWN BY;
ADZE 1 0111611a
DWG k: tNEV„
NOT[:ITEMS NOT SHOWN FOR CLARITY: CWS-$82 B
20.25-26.36-37,44,51-52,55-56,64.67-68 5 SHEFT
12 30F6
._._,...._ ..........._,._..........._ .................._..... ...... ...-_.f...-__._.�......................_
PARTS LIST FRAME CORNER �- }
(TEM PART# DESCRIPTION VENDOR MATERIAL 3 tra'-- CONSTRUCTION jCa
1 'I�a{/Lf
1 H 6049 Wain Fr.,SH,wIFI.,PVC,Head Mikron Vinyl { t 15116'-- vavutwuuv I(1]�(j "
_..... ....23it6'_.....
2 H-W9 Main Ft,SH,w/Flg.,PVC,Sill Mikron Vinyl 1 I WINDOW SYSTEPSS
3 1.6049 Main Fn,SH,w1Flg.,PVC,L,Jb. Mikron Vinyl i
2 I �_ 1900 SW 44TH AVE,
iii OCALA,Fl.gRIDA 34474
4 1+6049 Main Fc.SH,wtFlg.,PVC,R.Jb, Mikron Vinyl 1 it
5 H-1681 Hea Duty,Meet.Rall,Fxd,Aluminum Keymark At- € L, 1 sre' �1 II i WWW.CWS.CC
�y z11r7s'
8 5.1577 Impact Rook Keymark Alum
7116'
8 8+6050 Sash Meet,Raiff,PVC Mikron Vinyl t j 8100 PVC
9 11497 Reint Sash Meet.Rail Keymark Alum I -�'""""'-'-`- CORNER WELD
(ALL SIDES) ; SINGLE HUNG
10 H-6051 Sash Bottom Rail,PVC Mikron Vinyl �-- PVC SASH BTM.RAIL PVC SASH MTG.RAIL 1:8 � IMPACT
11 5-/498 Reint S.B.RIS,S.R Keymark Alum PVC FRAME FLANGE H-6051 H-6050
12 H-W62 Sash SidelTop/Bot,Rail Mikron Vinyl H•6049
[23
S-6064 Glz.Bd„718" Mikron Vinyl 37
13116"-- G z Qz5
56013 Scm.Adapt.,wlNib,PVC.kodz. Mikton Vinyl 314 6 w O w O d
S-6014 Som,Adapt.,PVC,Vert, - Mikron Vinyl t 118 •T » ,�tl z O Z k
56029 Sash Stop J Filler,PVC,Vett, Mikron Vinyl 51ia"`� l""" 11//�J" _ zzto�>-O ro y m
H-1699 Reinforcement,SBR Keymark Atum 1 �8} t Ste' 15..116' I'�", a-w zMuj _
i -1176' 2 z=�4CYw�p
P•2190 Balance BSI i -1116' 1116• 11yt-O ¢P-3059 Sash Cam,PVC BSI Plastic 1 • FIXED MEETING RAIL rf'wz a r ro n P•3046 Take Out CIID BSI SS PVC SCREEN SUPPORT SCREWED TOGETHER WITH D O z)vi 7 y
27 P-3763 Lock,Impact,PVC Intedock S•6014 REINF,SBR OUTERFRA.ME ¢Z LL p O LL Z
[30
P-4069 Keeper,impact,PVC Intedock Zamac PVC S K60SSH DE RAIL H-1699 L)1=-O m
P-3215 Weep Cover wl Flap Gaer Plastic FO 0 aNawrnw
S•6077 HD Fixed Meeting Rail Cofer Mikron Vinyl 3118" - z!1 of O�me-
Cur H 0 i�>N-
P-3429 Wslp.,0,270x,187 back FtnSeai,Grey Uitrefab 179' 'rd P4638 #8 x 2-1/2 PH Mod.Truss,Type A,TEK 2 Faslenal Sleet s 8"" t 118' --•- 1318• - J d N a ��aw.N P-3768 #8 x 0,625 Ph PH SMS Hub City Steel ` i ,. t12^-- , 1718-P-4051W#8 x 1.250 Ph FH TEK,Wirt. Hub Ci Steel } -ty . _ � 1311A P-4264W #8 x 3/4 FH PH w1#6 Head,TEK,Wht, Hub City Steel L t_�_!--Itis" »- e) �_ L tra' ,�%% WO
44 P-3342 Seam Seater,SM-5504 Schnee tris• �..„-,8116• •1� t C'i' FGE•N3,Fi. �.
45 P-3752 Cap Plug,1/2'Hole M&M Nylon REINF.SASH MTG.RAIL PVC SCREEN CATCH PVC SASH STOP v No 58201 •-fiP
47 P-3438 Sikallex 552 or Purfect Glaze•H' Sika/Henkel H-1497 $-6013 S•6029 HD MTG RAIL I e f
48 P-3352 SeL Blk„85 Dur.,1/8'x 5f8"x 2"Lg. F.Lowe Rubber H-1fi81
53 Sash SEE SHEET2 GLASS 4. -23,16•-" f %13 STATE Of 'W
7l8"-- 3. 1 -�•I
54 Fixed SEESHEET2 GLASS 9186' 17 314":U VS'-- t- i l -1314• I �i�OT QtORtOP•'N�4,
eal
62 P-3256 18 Screen Frame,Hadz. A1 Sparer DAmetal Alum �{j Ira 15116 3� '4; 10AIA i+S
r773
P-3218 Screen Frame;Veil. Allmetal Alum 7/7s T 1t }T �7f76•
P-3321 Screen Frame Comer Key Allmetai Plastic REINF.IMPACT HOOK
P-3581 Screen Cloth,18 x 16 Fiberglass Betterwe. Fiberglass S-1112 ftEiNS_498 SSR 1
P3228 Screen Spline,.155 Via.,Bik. Dapa Vinyl PVC GLAZING BEAD
ny 5�0� PVC MTG RAIL COVER I!
P-3029 Screen Pull Tab Summit Alum M077
P-3033 Screen Spring,SS Fl.Screen 55 1,-„-,_, 9/2212017
P-3113 Screw Support for PVC T.Plastics Nylon LUCAS A.TURNER,P.E.
5-1112 Reinforcement,Impact Hooks Keymark Alum A 3116- FL PE#58201
74 P•3541 1#8 x 70,Pan Head,TEK. Fastenal Steel b ._ O 1239 JASARA AVE,
NORTH PORT,FL 34288
f(
1 PH,94138Q-1574
LINE ITEMS NOT USED; r
-'
7,13;15-17,21-22,29,33.36,4lA3,48,49-52.55,57-61,69,71-72 15116' 112'-- fytiF,ETDESCRIPTIQNi -���”
......, 5 .........._ 3116'-
s� -- --� BOM AND EXTRUSIONS
Ira vfs F1 I Q
T
SCREW SUPPORT I}R4WN aY:--7DATE:
IMPACT HOOK P-3113 ADE 01/16/14
__.
$-1577 bWG ps
CWS-882 B_.....
s E: ISHEET
NOTE:ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED, . .
...........__....... _ _........�.z_.... »_ ......
TYPICAL HEAD ANCHORAGE MIN.EMBEDMENT Q�DOMTVEMOS .
SEE TABLE I SUBSTRATE.
EDGE DIST. BY OTHERS 1900 SW 44TH AVE,
SEE TABLE 1 114*MAY,SKIM L SEC TABLE 1 ALA.
FLORIDA 34474
WWWICWS�Cc
SUBSTRATE BY OTHERS r
SEE TABLE I MIN,EMBEDMENT
SEE TABLE I MIN,EVIE DIST.
PERIMETER SEA SEE TABLET 8100 PVC
SEALANT
-..—^--
SINGLE HUNG
INSIDEAND OUT INSTALLATION ANCHOR
SEALANT BEHIND SEE TABLE I IMPACT
FLANGE BY INSTALLER L 11,MAX.sHjm
C,
C, <
ZOZ WM
PERIMETER SEALANT �-W-z�-3:21
<Wuloo
MET %
ay'NSTAL.R z zm-.
0 0,3<T
INSIDE AND OUT I—���L P us 0.
INSTALLATION ANCHOR co
5-.Z
SEE TABLE 1 FLANGE BY INSTALLER -ZL-,WZO 0
LL20 U-Z
mopjzoNTALsEcnoN
CONTINUOUS DOUBLE U4'BEADS OF TYPICAL JAMB ANCHORAGE
I TREmGLA7X U I Goo SEALANT AROUND z w 0
PERIMETER AT ALL 11401CATFD POINTS - 0- w En
BETWEEN FRAME AND BUCK BY INSTALLER 0 ,j 0 tL=
w ul 3:w
0- a:
SEALANT BEHIND t 1/4'MAX.SHIM "tWottro",
FLANGE BY INSTALLER
s n
fi
PERIMETER SEALANT "I'LEMBEDMENT No 68201 'vl%
BY INSTALLER
.SEE
INSIDE AND OUT
1;210- STATE OF
SUBSTRATE BY GTHERS-_/ e
SEE TABLE I MINEDGE DIST. ...........
SEE TABLE I
CA\ VERTICALSECTION
PERIMETER
�JBF' i 1�0
"4
.E
_-&-_RAG E
TABLEA.APPROVED INSTALLATION FASTENERS LUCAS A.TURNER,P.E.
FL PE#58201
1239 JA
AVE,
rtJOSTRATE TYPE ANCHOR TYPE MIN.EMBEDMENT MIN,EDGE DIST. PERIMETER SEALANT----
VIT7n-W NORTH PORT,FL 34288
CONCRETE(ZO KSI MIX) TAPCON 1-11T I-itw BY INSTALLER
IJOLLOW,OR GROUT-FILLED CMU(117 PCF MIN.) 3116-rTw tAPcoN 1. 2' INSIDE AND OUT /-C"\ HORiZONTALSECTION PH,941.380-1574
7161—ELCO ULTRACON 1. —v iiINSTALLATION3 CONCRETE(2.85 KSI MIN,) HEAD AND SILL SIMILAR FOR BOX INSTALLATION
GROU`r-FILILED CMU(ASTM C-90) 311W ELOO,ULTRACON 1-114* 2-112
3116*ITW PCON INSTALLATION DETAILS
2X MIN.SOUTHERN PINE(G-0:5.5) Iy8* 7/8'
OR CLOD ULTRACON FLANGE REMOVAL NOTE:PARTIALLY OR FULLYREMOVING THE FLANGE, . DAIE:
" " UP TO AND INCLUDING A BOX-FRAME APPLICATION IS ACCEPTABLE PROVIDED: ��Dyl
2X MIN.SOUTHERN PINE(G=0.55) 010 WOOD SCREW 1-3/87t917ADi 01116114,
16 GAUGE(OXW)MIN.STEEL STUD 1110-lGHILnKWIK-FLEXORlTW FULL THREAD 7116" -MIN."114'FILLET OF CONSTRUCTION-GRADE ADHESIVE CAULK IS APPLIED awd F,
_(33 KSI YIELD MIN) TEKS SELF,-DRILLING SCREW THRU 0A60r INSIDE AND OUT,FULL PERIMETER,BY INSTALLER. 5 CWS-882 B
118"ALUM.(60"MIN.)OR, 1310 GRADE 5 SELF-TAPPING1 FULL THREAD 7116* -PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS
III$*STEEL(33 KSI MIN) DRILLING SCREW THRU 0,125* SHOWN FOR FLANGE WINDOWS.
1:2 6OF6
.....................
Tj T�j'�AT�� 1239 Jabara.Ave.
t„J North Port,FL 34288
ENGINEERING & Ph. 941-380-1574
CONSULTING, INC. FBPE C.O.A. #29779
Evaluation Report 882B
September 7,2017
Product Description: Series 8100 PVC Single Hung,Large Missile Impact,517/8"x 72"unit size with
Heavy Duty Meeting Rail,+/-70 PSF,no anchors in sill
Manufacturer: Custom Window Systems,Inc. 1900 SW 4,e Ave,Ocala,FL 34474
Statement of Compliance: This report evaluates the above-listed product per the requirements of FAC
Product Approval Rule Chapter 61G20-3.005(4). This product complies with the requirements of the 6'h
Edition(2017)Florida Building Code including the,High Velocity Hurricane Zone: The product testing
standards performed are outlined below.
Technical Documentation:
1) This report,prepared by Lucas A.Turner,P.E.,at 1239 Jabara Ave.,North Port,FL
2) Approval drawing CWS-882B,signed and sealed by Lucas A.Turner,P.E.
3) Test Report NCTL-210-3815-1 and-IA,by National Certified Testing Laboratories,Orlando,
FL,signed and sealed by Gerard.J.Ferrara,with testing performed: TAS 201/202/203-94,ASTM
E 1886-02/04/05,ASTM E 1996-02/04/06/09,and AAMA/WDMA/CSA 101/I.S.2/A440-08
4) Supplemental Cafes_to support CWS-88213,signed and sealed by Lucas A.Turner,P.E.
Installation: Units must be installed according to approval document GWS-882B.
Limitations of Use: This product:
• May be used in 4/X configuration in sizes and with max.glass DLO heights as shown in CWS-
882B
• Is impact resistant and does not require the use of shutters
• May be used in the High Velocity Hurricane Zone
• Requires 7/8"Insulating Glass consisting of 1/8 Annealed or Tempered outboard lite(Tempered
required above 30 ft in HVHZ) —Air—5/16 Laminated(1/8Ann-.090PVB-1/8Arm)inboard lite
• Requires Kuraray(Dupont)PVB Interlayer per Miami-Dade N.O.A. 16-1117.021
• Requires Quanex(1blikron)white rigid PVC framing per Miami-Dade NOA 17-0206.10' is
{
t I have evaluated the interlayer and framing materials in these Dupont and Quanex NOAs and.find
that they comply with the requirements of the 0"Ed.(2017)Florida Building Code for use in this
product. t
Certification of Independence: I do not have,nor do 1 intend to acquire,nor will I acquire,a financial
interest in Custom Window Systems or in any company manufacturing or distributing products for which
this report is being issued. I do not have,nor do I intend to acquire,nor will I acquire,a financial interest
in any other entity involved in the testing or approval process of this product. `
l
t*is�etu�tir����
Lucas :-w.1 No 50201 .� 9/07/2017
*e =*= Lucas A.Tumer, P.E.
Turner * - s
s STATE OF, :'Au FL PE#58201
2017-09-16 .,t',:+ 'i
09:29+20:00