HomeMy WebLinkAboutProduct Approval (3) Copy- MIAMMIAMI-DADS COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 RECEIVED----- -T 786=miamidade.gov/building 2590 F(786)315-2599 NOTICE OF ACCEPTANCE OA Sun-Tek Manufacturing,Inc. 10303 General Dr. N o 1('_10113 Orlando,FL 32824 ST. Lucie County, Permitting SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: MD-CMA Skylight. APPROVAL DOCUMENT: Drawing No. CMA-002,titled "MD-CMA",sheets 1 and 2 of 2,prepared by Sun-Tek Manufacturing,Inc., dated May 09,2011,signed and sealed by James D.Wells,Jr.,P.E.,on October 06,2017,bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and the expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved"or the Product Control Seal,unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA#15-0513.05 and consists of this page 1,evidence submitted pages E-1,E-2, and E-3 as well as approval document mentioned above. The submitted documentation was reviewed by He yDA.Makar,P.E.,M.S. MIAMI-DADE COUNTY �(� NOA No. 17-1023.18 Expiration Date: 03/13/2023 Approval Date: 03/15/2018 / / Page 1 Sun-Tek Manufacturing,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#08-0110.06 A. DRAWINGS L Manufacturer's die drawings and sections. 2. Drawing No. CMA-002, titled "IvM-CMA",sheets 1 and 2 of 2,prepared by Sun-Tek Manufacturing,Inc., dated 09113195 and 04125195, with no revisions, signed and sealed by Rene J. Quiroga, P.E. B. TESTS 1. Test reports on 1)Air Infiltration Test,per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test,per FBC, TAS 202-94 4)Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6)Forced Entry Test,per FBC 24113.2.1, TAS 202-94 along with marked-up drawings and installation diagram of Model MD-CMA Curb Mounted Plastic Dome Skylight,prepared by National Certified Testing Laboratories, Test Report#210-2885-1, dated 10131102, signed and sealed by W. A. Davis Jr., P.E. C. CALCULATIONS 1. Anchor calculations prepared by Product Technology Corporation on 02105103, signed and sealed by A. Perez Maldonado, PE. D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office(BCCO) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 07-0212.01 issued to General Electric Plastics for their "Lexan Sheet Products", approved 05/25/07, expiring on 07/17/08.. F. STATEMENT 1. Code compliance letter issued by Product Technology Corporation on 02/06/03, signed and sealed by A. Perez Maldonado (Evidence Submitted under NOA # 03-0401.07) G. OTHERS 1. Notice of Acceptance No. 03-0401.07,issued to Sun-Tek Manufacturing,Inc., approved on 10/09/03 and expiring on 03/13/08. 2. No change letter issued by Sun-Tek Manufacturing,Inc., dated 01/02/08,signed by James Feudner. A=Z4 elmy A.Makar,P.E.,M.S. Product Control Section Supervisor NOA No. 17-1023.18 Expiration Date: 03/13/2023 Approval Date: 03/15/2018 E-1 Sun-Tek Manufacturing,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2: EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#11-0601.04 A. DRAWINGS 1. Drawing No. CMA-002, titled ".AM-CMA", sheets I and 2 of2,prepared by Sun-Tek Manufacturing, Inc., dated May 09, 2011, signed and sealed by James D. Wells, Jr., P.E., on May 08, 2012. B. TESTS 1. Test reports on 1)Air Infiltration Test,per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test,per FBC, TAS 202-94 4)Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6)Forced Entry Test,per FBC 24113.2.1, TAS 202-94 along with marked-up drawings and installation diagram of Model MD-CMA Curb Mounted Plastic Dome Skylight,prepared by National Certified Testing Laboratories, Test Report No. NCTL-210-3859-1, dated 03104113, signed and sealed by Gerard J. Ferrara, P.E. C. CALCULATIONS 1. Anchor calculations prepared by J&L Wells Consulting LLC, 19 pages, dated 0311912013, signed and sealed by James D. Wells, Jr., P.E. D. QUALITY ASSURANCE 1. By Miami Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENT 1. Florida Building Code, 2010 Edition, compliance letter prepared by J&L Wells Consulting LLC, dated 0412512012, signed and sealed by James D. Wells, Jr., P.E. 3. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#15-0513.05 A. DRAWINGS 1. Drawing#CM4-002, titled "AM-CMA", sheets 1 and 2 of 2,prepared by Sun-Tek Manufacturing,Inc., dated 05109111, signed&sealed by James D. Wells,Jr., P.E., on 05108112. B. TESTS 1. None. C. CALCULATIONS 1. None. ,Odmy A.Makar,P.E.,M.S. Product Control Section Supervisor NOA No. 17-1023.18 Expiration Date: 03/13/2023 Approval Date: 03/15/2018 E-2 Sun-Tek Manufacturing,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED D. QUALITY ASSURANCE 1. By Miami-Dade County Department of Regulatory and Economic Resources. _ E. MATERIAL CERTIFICATIONS L None. F. STATEMENT 1. Florida Building Code,'2014 Edition, compliance letter prepared by J&L Wells Consulting LLC, dated 0510512015, signed and sealed by James D. Wells, Jr., P.E. 4. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. CMA.-002, titled "MD-CMA", sheets 1 and 2 of 2,prepared by Sun-Tek Manufacturing, Inc., dated May 09, 2011, signed and sealed by James D. Wells, Jr., P.E., on October 06, 2017. B. TESTS 1. None. C. CALCULATIONS L None. D. QUALITY ASSURANCE 1. By Miami-Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENT 1. Florida Building Code;2017 Edition, compliance letter prepared by J&L Wells Consulting LLC, dated 1010612017, signed and sealed by James D. Wells, Jr., P.E. c0Jelmy A.Makar,P.E.,M.S. Product Control Section Supervisor NOA No. 17-1023.18 Expiration Date: 03/13/2023 Approval Date: 03/15/2018 E-3 `eitiaaaait�ttdjj, J. L Wells Consulting LLC �" � Engineer of Record. 1453 Arbitus Circle Z! - 0. James D.Wells,Jr.,P.E. Oviedo,Fl.32765 .: 53 16 Professional Engineer No.53616 (407)496-5489 _ ! !Q/b f�/} jAU Certificate of Authorization No.27162 STAT OF : PART A D—C A PLA �»»»„ -- DRAENIBY; S 2 f CMA-002 3.O000 (��10.625-+-1 t O"TLA OONr.are POL3C"OoRttre -OLVDAR04,11E Stan CO SuwNK DOIC(CON'.Wa) SPAffTKI tPaAud , aN 95-tp0C tL%t 9pS KUuWM0– w (WN1P1tDS) CO 4Q DLCO no Rule a QQ �hp6p0,NICK ALUWNau Q (� M93NtsaEO CkRH[RS r nw Y.Aa VKt 75 At-j—Rl,el =PAL ICR W[R a30 AAV-- (')Is,raer S7OC W M.LON,or PLC LIMN 9071 (!p%2 PNWPS PAN NrAO SHEET(Ir(Ai sEREW IA)ON LONC Soft(3)04 5N04t SIDELij In DIMENSI❑NS FOR FASTENER L❑CATI❑NS ¢ MSN fp9NEp fAEL U1 1004 i Ito a 3- O LONG 0,OWNERS{.1. In (1)6V LUNO Sip[ �'•, Dwr COUNIII 14 FASTENERS Q (s)ONw�NSHpRI S�pE TO CURB MD—CMA 2246 N / aRNA)GDA,[ ;NHRDA SMpEs(xl In IA SIP(SC as"CURD NEK:NI Tp OE rcgS,Tf¢¢Nf I 84NTUR (] of uFW{lLOM51 POOR I 16 RODi SI WALE 6 RIVETS ' NPPUEp o OI T S D+ POLY TO ALUMNOTE: (AP 4MD 7K DAVE COUNT,) RIVET L❑CATI❑NS SYM Q (1) ALL ROOFING DETAILS SHALL COMPLY WITH CHAPTER 15 OF THE 2617 FLORIDA BUALDINC CODE Q DESIGN PRESSURE RATING (2) 4" MINIMUM DISTANCE SHINGLE.LE. ANGLE LIP tD ROOF +— 60 PSF. SURFACE IS FOR SHINGLE. OR D TIL WITHOUT TILELATION. FOR HEIGHT AND INSULATION TH CKNESS TO E ROOFn URGE MISSILE IMPACT RESISTANCE MINIMUM HEIGHT. (3) ANCHCOMPORS TO BE MADE OF H ALUMINUM.O –CORROSIVE MATERIAL. �--13.625---- �- 27.250 MAX. FASTENER SCHEDULE SKYLIGHT TO CURB FASTENER SCHEDULE CURB RIVET SCHEDULE DECO -p—p—C)L U F R2 V1SE-D 10 X 2 PAN HEAD SHEET METAL SCRE S TO DECK Q10 X 3- DECK 10 POLYCARBONATE 3/16"DIA. .93 MosxlPIYU%with t1le F1014C1k SCREWS Buil,iiT1E 4�Osle PER LONG PER SHORT PER LONG PER SHORT PER LONG PER'SHORT :irCC`ttatl(;e dz/ A MODEL SIDE SIDE SIDE SIDE SIDE SIDE Exl nation Dve O / AO 4 4 3 a 23 4 3 a 3 2 t .� 22 3 3 1 1 i' i De S UC ✓ 1919 - S 3 ta22 3 14°5 4 .3 1 a 1 3 3 3 3 1 1 a 4 2 2 1 REv1SION, REV1S10N< PRODUCT NAME: 1 ,, MD--CMA SUN-TCK MANUFACTURING, INC. AILD T i 09.11 1 SCALE! I DVtG NN A—QQ2 10303 GENERAL DRIVE ORLANDO. FL 32824 SIDN'VID J&L Wells Consulting LLC 1453 Arbitus Circle S. Engineer of Record: Oviedo,FL 32765 0. 3616 James D.Wells,Jr.,P.E. (407)496-5489 Professional Engineer No.53616 Certificate of Authorization No.27162 —owl lco> b /7- 40t $TATE OF PART NAME:_ PRODUCT DRAWING ISHE I -ON -2 tw, .01 CMA-002 DESIGN PRESSURE RATING /fill ISO PSF #10 X 2" SCREW PPH LARGE MISSLE IMPACT RESISTANCE OUTER DOME .070 POLYCARBONATE (4) ON LONG SIDE& (3) ON SHORT SIDE (Polrom Polsun, MINIMUM ENBEDMENT 1" Sheffield Mokroton or Sobic Lexon 9034) SILICONE BEDDING (CONTINUOUS) OECD RING STI-275 7— _060 THICK ALUMINUM BUTYL RUBBER SEALANT 6063 T6 MITRE BETWEEN SKYLIGHT AND WELDED CORNERS AND CURB (continuous) INNER LINER, .030polycorbonote 5-1/2" DOME RISE SHIM@ EA. ANCHOR (TYP) (Polrom Polsun, AIR FILIED INSULATED SPACE WITH LOAD BEARING SHIM Sheffield Mokrolon-or 0.500 MAX, Sobic Lexon 9034) ryy as complying with the Flopida ------ 3/16" RIVETBuildftngCO'CF'/LONG SIDEAcceptmcoNoll-I D7-.T. �, /SHORT SID E onDaw p "y I,&D4- r7Ao'", ri #10 x 3" DECK SCREW FINISHED WALL MATERIAL (4) ON LONG SIDE FLASHING BY OTHERS IN 4" MINIMUM (3) ON SHORT SIDE BY OTHERS ( APPROVED [ACCORDANCE WITH NRCA SEE NOTE #2 DADE COUNTY) MINIMUM ENBEDMENT 5/8' SlINCLES (2) 0 kn 0 in NOTE: co -Ij (1) ALL ROOFING DETAILS SHALL COMPLY WITH I L CHAPTER 15 OF THE 2017 FLORIDA BUILDING CODE (2) 4" MINIMUM DISTANCE FROM ANGLE LIP TO ROOF SURFACE IS FOR SHINGLE. OR B.U.R. WITHOUT 2X SYP (SC 0.55) CURB HEIGHT INSULATION. FOR INSULATION AND TILE ROOF ADD TO BE SUFFICIENT TO MAINTAIN TILE HEIGHT AND INSULATION THICKNESS TO 4" 4" MINIMUM AT LOWEST POINT MINIMUM HEIGHT. OF FRAME TO ROOF SURFACE (3) ANCHORS TO BE MADE OF NON-CORROSIVE MATERIAL, ROOF DECK SUPPLIED BY OTHERS AN COMPATABLE WITH ALUMINUM. (APPROVED BY DADE COUNTY) STS-1000 SEALANT (CONTINOUS) REVISION REV11 PRODUCT NAME, MD-CMA SUN-TEK MANUFACTURING, IC 0. FL 32824 _rNF_ IIDATEz5.09,11 1 $C144E� 115 NgmCM6-OQ2 70303 GENERAL DRIVE ORLAND aLi