Loading...
HomeMy WebLinkAboutDrawing RECEIVED Nov 3 0 2018 ST. Lucie County,per ?� !rC r`L>• g I'I 72" X 96 1 REPLACE DOORS IN 1 OPENING ONLY. OPENING HAS EXISTING HURRICANE PROTECTION INSTALLED UNDER PERMIT#24011253 PER HOMEOWNER. OPENING PRODUCT DESIGN OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS NO. WIDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG. 1 72 T 96 48.00 4 36.5 1 -39.9 FL208675' 47.0 1 -47.0 FRONT ENTRY-LSMI REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS. NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS. ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS. LESS THAN 30%OF STRUCTURE'S VALUE.NOT A RENOVATED BUILDING. EXEMPT FROM 2017 ENERGY CONSERVATION CODE. SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES MEAN ROOF HEIGHT= 18 FT 1 IN BRENGARD RESIDENCE 8742 TOMPSON POINT ROAD DOOR REPLACEMENT PLAN PORT ST. LUCIE, FLORIDA