Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=w... t r�r BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search db� €t A Product Approval USER:Public User Procuct Approval Menu>Procuct or Ipohcatinn Search>Application List>Application Detail FL# FL14095-R10 Application Type Revision Code Version 2017 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer JELD-WEN Address/Phone/Email 3737 Lakeport Blvd Klamath Falls,OR 97601 (800)535-3936 fbcl@jeld-wen.com Authorized Signature Rylee Sumner Fricks fbcl@jeld-wen.com Technical Representative JELD-WEN Corporate Customer Service Address/Phone/Email 3737 Lakeport Blvd. Klamath Falls,OR 97601 (800)535-3936 customerserviceagents@jeld-wen.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 07/11%2017 1 of 3 12/03/2018 10:12 AM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=w... Date Validated 07/26/2017 Date Pending FBC Approval Date Approved 07/28/2017 Summary of Products FL# Model,Number or Description ;Name 14095.1 Premium Atlantic Single Hung(8100)36"x 72"Insulated Glass(5/16 in PVB or SGP Lam-1/8 out Annealed) Vinyl Limits of Use Certification Agency Certificate j Approved for use in HVHZ:Yes 1 FL14095 R10 C CAC NI011567.04-R3.pdf 1 Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 04/30/2025 Impact Resistant:Yes Installation Instructions Design Pressure:+65/-70 FL14095 R10 II FL14095 R5 II DP65-70 36x72 Impact Installation Instructions.pdf Other:Laminated glazing interlayer FL14095 R10 II NI011567.04-R3 Dwgs 07252017.pdf i material requirements meet the Verified By: Hermes Norero,PE 73778 current edition of the FBC in Created by Independent Third Party:Yes accordance with Miami-Dade NOA :.Evaluation Reports I for DuPont SentryGlas and DuPont FL14095 R10 AE PER3094.pdf PVB interlayers.White PVC exterior Created by Independent Third Party:Yes extrusion meet the current edition of the FBC in accordance with Miami-Dade NOA for Quanex.IG back bedded with Dow 995.Safety ;glazing required to the exterior at !heights above 30 feet. 14095.2 Premium Atlantic Single Hung(8100)36"x 72"Insulated Glass(1/8 in-1/8 out Annealed) Vinyl Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes I T FL14095 R10 C CAC N1011567.06-Rl.pdf Approved for use outside FL14095 R10 C CAC NI011567.09-R2.pdf HVHZ:Yes 'Quality Assurance Contract Expiration Date Impact Resistant:No 04/30/2025 Design Pressure:+65/-70 Installation Instructions Other:White PVC exterior FL14095 R10 II NI011567.09-R2 Dwgs 07252017.pd extrusion meet the current edition of' FL14095 R10 II PAV TSH FBC 36x72 SS 2017-06-26.pdf the FBC in accordance with Verified By: Hermes Norero,PE 73778 i Miami-Dade NOA for Quanex.IG Created by Independent Third Party:Yes back bedded with Dow 995.Safety Evaluation Reports glazing required to the exterior at FL14095 R10 AE PER4869 SS 2017-06-26.pdf heights above 30 feet. Created by Independent Third Party:Yes — ---- -- --. --- - .......... 14095.3 Premium Atlantic Single Hung(8100)52 1/8"x 75'Insulated Glass(3/16 in-3/16 out Annealed) Vinyl Li tim sof Use — Certification Agency Certificate Approved for use in HVHZ:Yes I FL14095 RSO C CAC NI011567.06-Rl.pdf Approved for use outside FL14095 R10 C CAC NI011567.07-R2.pdf !HVHZ:Yes 'Quality Assurance Contract Expiration Date Impact Resistant: No 04/30/2025 { Design Pressure:+65/-70 1 Installation Instructions Other:White PVC exterior FL14095 RIO–II NI011567.07-R2 Dwqs 07252017.pdf extrusion meet the current edition of FL14095 R10 II PAV TSH FBC 5205 SS 2017-06-26.pdf 1 the FBC in accordance with Verified By: Hermes Norero,PE 73778 j Miami-Dade NOA for Quanex.IG Created by Independent Third Party:Yes back bedded with Dow 995. i Evaluation Reports Windows with insulated glass wider FL14095 R10 AE PER4870 SS 2017-06-26.pdf I than 36"require setting blocks. Created by Independent Third Party:Yes Safety glazing required to the t exterior at heights above 30 feet. 14095.-4 Premium Atlantic Single Hung(8100)52 1/8"x 75"Insulated Glass(5/16 in PVB or SGP Lam-1/8 out Vinyl Annealed) -. ._....... . ... – Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14095 R10 C CAC NI011567.02-R2.pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 04/30/2025 ' Impact Resistant:Yes Installation Instructions Design Pressure:+50/-60 FL14095 R10 II FL14095 115 II DP50-60 52.125x75 Impact Installation Instructions pdf Other:Laminated glazing interlayer FL14095 R10 II N1011567.02-R2 Dwgs 07252017 )df material requirements meet the Verified By: Hermes Norero,PE 73778 current edition of the FBC in Created by Independent Third Party:Yes accordance with Miami-Dade NOA Evaluation Reports for DuPont SentryGlas and DuPont FL14095 RIO AE PER3091 odf PVB interlayers.White PVC exterior ' Created by Independent Third Party:Yes extrusion meet the current edition of the FBC in accordance with 2 of 3 12/03/2018 10:12 AM 7FloridaBuilding Code Online https://www.floridabuilding.org/pr/pi_app_dtl.aspx?param=w... Miami-Dade NCA for Quanex.IG back bedded with Dow 995.Windows) with insulated glass wider than 36' I j require setting blocks.Safety glazing j required to the exterior at heights above 30 feet. 14095.5 Premium Atlantic Single Hung(8100)52 1/8"x 75"Insulated Glass(5/16 in SGP Lam-3/16 out Annealed) Vinyl Limits of Use i Certification Agency Certificate Approved for use in HVHZ:Yes FL14095 R10 C CAC NI011567.01-Rl.odf Approved for use outside FL14095 R10 C CAC N1011567-RI.pdf HVHZ:Yes 4 Quality Assurance Contract Expiration Date Impact Resistant:Yes 04/30/2025 Design Pressure:+65/-75 I Installation Instructions j Other:Laminated glazing interlayer I FL14095 R10 II FL14095 R5 II DP65-75 52.125x75 Impact Installation Instructions.pdf i material requirements meet the FL14095 R10 II NI011567.01-R1 Dwos 07252017.pdf current edition of the FBC in Verified By: Hermes Norero,PE 73778 1 accordance with Miami-Dade NOA I Created by Independent Third Party:Yes for DuPont SentryGlas and DuPont Evaluation Reports PVB interlayers.White PVC exterior FL14095 R10 AE PER3095.Ddf extrusion meet the current edition of j Created by Independent Third Party:Yes the FBC in accordance with Miami-Dade NOA for Quanex.IG back bedded with Dow 995. I Windows with insulated glass wider I than 36"require setting blocks. j Safety glazing required to theit I exterior at heights above 30 feet. I Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395. Pursuant to Section 455.275(1),Florida statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: grr«t IM Credit Card Safe 3 of 3 12/03/2018 10:12 AM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=W... i®rti�� BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search Product Approval r USER:Public User Procuct Approval Menu>Product or Anphcation Search>Application List>Application Detail FL# FL14095-R10 Application Type Revision Code Version 2017 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer JELD-WEN Address/Phone/Email 3737 Lakeport Blvd Klamath Falls,OR 97601 (800)535-3936 fbcl@jeld-wen.com Authorized Signature Rylee Sumner Fricks fbcl@jeld-wen.com Technical Representative JELD-WEN Corporate Customer Service Address/Phone/Email 3737 Lakeport Blvd. Klamath Falls,OR 97601 (800)535-3936 customerserviceagents@jeld-wen.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 07/11/2017 1 of 3 12/03/2018 10:13 AM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=w... Date Validated 07/26/2017 Date Pending FBC Approval Date Approved 07/28/2017 Summary of Products FL# Model,Number or I Description Name 114095.1 Premium Atlantic Single Hung (6100)36"x 72"Insulated Glass(5/16 in PVB or SGP Lam- 1/8 out Annealed ) Vinyl Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14095 R10 C CAC NI011567.04-R3.pdf Approved for use outside 'Quality Assurance Contract Expiration Date HVHZ:Yes 04/30/2025 ' Impact Resistant:Yes Installation Instructions Design Pressure: +65/-70 FL14095 R10 II FL14095 R5 II DP65-70 3602 Impact Installation Instructions.pdf Other:Laminated glazing interlayer FL14095 R10 II NI011567.04-R3 Dwgs 07252017.pdf material requirements meet the Verified By: Hermes Norero,PE 73778 current edition of the FBC in Created by Independent Third Party:Yes accordance with Miami-Dade NOA 'Evaluation Reports for DuPont SentryGlas and DuPont FL14095 R10 AE PER3094.1)df PVB interlayers.White PVC exterior Created by Independent Third Party:Yes extrusion meet the current edition of the FBC in accordance with Miami-Dade NOA for Quanex.IG back bedded with Dow 995.Safety I glazing required to the exterior at heights above 30 feet. 14095.2 Premium Atlantic Single Hung(8100)36"x 72"Insulated Glass(1/8 in-1/8 out Annealed) Vinyl Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes 1 FL14095 R10 C CAC N1011567.08-R1.odf Approved for use outside 1 FL14095 R10 C CAC NI011567.09-R2.pdf HVHZ:Yes i Quality Assurance Contract Expiration Date Impact Resistant: No 04/30/2025 p Design Pressure:essure: +65/-70 Installation Instructions Other:White PVC exterior FL14095 R10 I: NI011567.09-R2 Dwgs 07252017 pdf extrusion meet the current edition of FL14095 R10 II PAV TSH FBC 3602 SS 2017-06-26.pdf the FBC in accordance with Verified By: Hermes Norero,PE 73778 Miami-Dade NOA for Quanex.IG i Created by Independent Third Party:Yes back bedded with Dow 995.Safety 'Evaluation Reports glazing required to the exterior at FL14095 R10 AE PER4869 SS 2017-06-26.pdf heights above 30 feet. Created by Independent Third Party:Yes 14095.3 Premium Atlantic Single Hung(8100)52 1/8"x 75"Insulated Glass(3/16 in-3/16 out Annealed) Vinyl Limits of Use !Certification Agency Certificate Approved for use in HVHZ:Yes FL14095 R10 C CAC NI011567.06-Rl.pdf Approved for use outside FL14095 R10_-C- CAC NI011567.07-R2.pdf HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 04/30/2025 Design Pressure:+65/-70 Installation Instructions I Other:White PVC exterior FL14095 R10 II N1011567.07-R2 Dwgs 07252017.pdf extrusion meet the current edition of FL14095_R10_II_PAV TSH FBC 52x75 SS 2017-06-26.pdf I the FBC in accordance with Verified By: Hermes Norero,PE 73778 Miami-Dade NOA for Quanex.IG Created by Independent Third Party:Yes back bedded with Dow 995. Evaluation Reports Windows with Insulated glass wider FL14095 R10 AE PER4870 SS 2017-06-26.pdf than 36"require setting blocks. Created by Independent Third Party:Yes Safety glazing required to the exterior at heights above 30 feet. 14095.4 'Premium Atlantic Single Hung(8100)52 1/8"x 75"Insulated Glass(5/16 in PVB or SGP Lam-1/8 out Vinyl Annealed) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14095 R10 C CAC NI011567.02-R2.pdf Approved for use outside Quality Assurance Contract Expiration Date f HVHZ:Yes ' 04/30/2025 Impact Resistant:Yes Installation Instructions Design Pressure: +50/-60 FL14095 R10 11 FL14095 R5 II DP50-60 52.125x75 Impact Installation Instructions.pdf Other:Laminated glazing interlayer FL14095 R10 II N1011567.02-R2 Dwgs 07252017.pdf 3 material requirements meet the Verified By: Hermes Norero,PE 73778 current edition of the FBC in ! Created by Independent Third Party:Yes accordance with Miami-Dade NOA Evaluation Reports for DuPont SentryGlas and DuPont FL14095 R10 AE PER3091.0 PVB interlayers.White PVC exterior Created by Independent Third Party:Yes !extrusion meet the current edition of the FBC in accordance with 2 of 3 12/03/2018 10:13 AM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=w... i ' Miami-Dade NOA for Quanex.IG back bedded with Dow 995.Windows! with insulated glass wider than 36" j require setting blocks.Safety glazing j required to the exterior at heights above 30 feet. —� 14095.5 Premium Atlantic �SmgleH.utng(8100) 52 1/8 x 75"Insulated Glass(5/16 in SGP Lam-3/16 out Annealed) Vinyl Limits of Use ion Agency Certificate Approved for use in HVHZ:Yes FL14095 R10 C CAC N1011567.01-R1.pdf I Approved for use outside ( FL14091 R10 C CAC NI011567-R1,pd1 HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes I 04/30/2025 Design Pressure: +65/-75 (Installation Instructions Other:Laminated glazing interlayer I FL14095 R10 II FL14095 R5 II DP65-75 52.125x75Impact Installation Instructions Ddf material requirements meet the FL14095 R10 II NI011567.01-R1 Dwps 07252017.1)df current edition of the FBC in Verified By: Hermes Norero,PE 73778 accordance with Miami-Dade NOA Created by Independent Third Party:Yes for DuPont SentryGlas and DuPont Evaluation Reports PVB interlayers.White PVC exterior ' FL14095 R10 AE PER3095.pdf extrusion meet the current edition of! Created by Independent Third Party:Yes the FBC in accordance with I( Miami-Dade NOA for Quanex.IG I back bedded with Dow 995. I Windows with insulated glass wider I than 36"require setting blocks. Safety glazing required to the i exterior at heights above 30 feet. ..---._.._ .. ..__.—...... .........1. .__.._..._ Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Credit Card Safe 3 of 3 12/03/2018 10:13 AM i om NAIL FIN INSTALLATION CORNERS ' V� Ili:".N:Y'VR�.:!4NT 2 MIN DISTANCE FOR EDGE.3/4" MAX.THRU RUE Erw '' �cuf•,;G[t-, 2X WOOL) 3 3 FRAME i l i; zzrm i 2 1/4"MAX SHIM SPACE I , � 1 1/2"MIN. ' I e EMBEDMENT I � I / GLAZING DETAIL _FRAME SECTION(TYP) .IAMB SECTION(TYP) VERTICAL SECTION HORIZONTAL SECTION im 51ACE 3 s•WO, EROY .H_r�nr>rnvc[ `°"Ms PREMIUM ATLANTIC VINYL SH WINDOW t Z Max Frame I DP RATING IMPACT wv+now woErr(36'wx.) I i 1/r.u,r:E.uacpu.Er:r 36 x 72 +65/-70 YES I TYPICAL ELEVATION WITH FASTENER SPACING LARGE MISSILE IMPACT Installation Notes: General Notes: I Seal flange/frame to substrate. i. The product shown herein is designed,tested arid manufactured to comply with the wind load criteria 2. Use#10 PH or greater fastener though the nail fin with sufficient length to penetrate a minimum of 1 of the adopted International Building Code(IBC).the International Residential Code(IRC),the Florida 112"into the wood framing. For 2X wood frame substrate(min.S.G.=0.42). Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. 4 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 2. All glazing shall conform to ASTNI E1300. to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing is 3mm annealed-11 mm airspace-3mm annealed-2mm PVB Interlayer by project of installation. DuPont-3mm annealed. Reason:I am apprr Digitally signed Hermes F. P.E. 4 Use structural or composite shims where required. oving this documeocume nt Date:2014.09.19 16:26:14-04'00' This schedule addresses oniv the fasteners required to anchor the ,` window to achieve the rated design pressure up to the size limitations \"\ noted. It is not intended as a guide to the installation process and does �� r aarr.r 1:r,crver.R: nr,1r: t . �i 3737 Lakeport Blvd not address he sealing consideration that may arise in different wall 03/13/2014 � , •, � •••\G/ • � JELDNEN Klamath Falls,OR.97601 conditions For the complete installation procedure,see the instructions .� , u nvc:131: x:Acl:: packaged with the window or go to i/N0/,7�778 - — D. Vezo NTS Phone: (5 tt)8,92-3,451 www.jeld-wen.com/resourcestinstallalion = * �*� �� t * = J. Kantola ECKLID P": 11r� DISCLAIMER; DTATE OF = PRw::,BY: Premium Atlantic Vinyl Impact Single Hung Window 1�1 I Thls drawing and its contents are confidential and are riot to be % O •'•. '�OK IDP•'• rcnen n-, reproduced or copied in whole or in part or used or disclosed to others ��� p Eb' e��` D/v,:008729 except is authorized by JELD-WEN Inc,. sea a a1te 338 INCTL210 3875- PIf3C`AI, rlr:lf.+-ATL:n CAD r,l/1, I4; u=V 00 ;nrrr a L 4 or C--�5.5"UAX h,�l MASONRY INSTALLATION mom CORNERS :-� IS•O.C. d a d 3 vluFE n.+r rt* UU.TNRU - JAMB 4 i j l 1"h16FI:MENI 1�9'MA% a a 5I.-CE u v >r:nr.�e ° a �J l _-_ Y. IMI ' I ,IAMB SECTION(TYP) GLAZING DETAIL HORIZONTAL SECTION ! ! FRAME 5ECTION(TYP) VERTICAL 5ECTTON ,, V � ./! CORNERS '! ,a a c ExiFE0.uc rt " PREMIUM ATLANTIC VINYL SH WINDOW s.Q mss, P R Max Frame DATING IMPACT womoW mnTN(36•WAX) '. a. 36 x 72 +65/-70 1 YES TYPICAL ELEVATION WITH FASTENER SPACING LARGE MISSILE IMPACT Installation Notes; General Notes: 1. Seal flangerframe to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria 2. Use 3116"ITW Tapcon or equivalent fasteners through frame with sufficient length to penetrate a of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida minimum of 1 14'into concrete or masonry at each location with a 2 1/2"min from edge distance.For Building Code(FBG)including HVHZ and the industry requirement for the stated conditions. concrete (min.f c=3000psi)or masonry substrate(CMU shall adhere to ASTM C90). 2. All glazing shall conform to ASTM E1300. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 3. At minimum.glazing is 3mm annealed-11 mm airspace-3mrn annealed-2mm PVB Interlayer by to the structure. The host structure is the responsibility of the architect or engineer of record for the DuPont-3mm annealed. project of installation. 4. Use structural or composite shims where required. This schedule addresses only the fasteners required to anchor the `�, window to achieve the rated design pressure up to the size limitations ��� noted. It is not intended as a guide to the installation process and does ♦ --F " i PROJECT ENGI NFIR: BATE. • F �i not address he sealing consideration that may arise in different wall QQ 3737 Lakeport Blvd p-.l,(<` - 08/13/2014 l �/ ••\GS '••'A i conditions. For the complete installation procedure,see the instructions ;'•\.- , ,• u^AI'-',Erv' sc,u-e: J EL N Klamath Falls,OR.97601 packaged with the window or go to 0/ T! D. Vezo NTS Rhone: (541)flsz i�Y -3451 i:IL: ww%v.jet(1-wet).comkesources/installation t * J. Kantola -0TATjE F +Y A-POVED6:: Premium Atlantic Vinyl Impact Single Hung Window I DISCLAIMER: -;3 •_ �1 rL _ This draviing and its contents are confidential and are not to be % 0 =.��OfKtOP;•'• j reproduced or copied in whole or in part or used or disclosed to others �i� P E�o. B`�`. D00$729 Iexcept as authorized by JELD-WEN Inc. See e �9ulte ase 1DFR7T,F1FR Nu r,t.uT na>Ip.mn inrnTTOII n rrc,G u,! RfV a,EEr ICA fee ` Fl04 NCTI-210 3875 -FBC 00 ' 5 CORNERS IES' A:\CTSTA WCC FOR C06F W, STEEL INSTALLATION rROM 2 is'O.C. 16'—A'mlil. 18 ginuge min UAX THRU stun JAm MB sttid fHfAi SPACE 1/4'MAX SHIM 5PACE 2 MIN DISTANCE FOR EDGE:112' Mim mbed."i k 9 of th'ec threads 3 --T pasi fra— ',i Ar,-',9r7E 13" 77- T/ GLAZING DETAIL. JAMB SECTION(TYP) FRAME SECTION HORIZONTAL SECTION 1r) VERTICAL SECTION I I 4" "A H';� A1:1 A n 1/4'MAX SHEN.5r ACE FROM T-9" CORNERS PREMIUM ATLANTIC VINYL SH WINDOW Max Frame I DP RATING IMPACT 71':9 I—WINDOW MOTH(Sol W".)—1 1 1 P—t— i 1 1 36 x 72 +65/-70 1 YES MLt,).L",STArICE i TYPICAL ELEVATION WITH FASTENER SPACING LARGE MISSILE IMPACT General Notes: Installation Notes: 1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria 2. For anchoring into metal framing use#8 TEK Self Tapping screws with sufficient length to achieve a of the adopted International Building Code(IBC),the International Residential Code(IRC).the Florida Building Code(FBC)including HVHZ and the industry requirement for the stated conditions minimum embedment of three threads past the frame thickness. Steel substrate min.18ga.,fy=33 ksi, 2. All glazing shall conform to ASTM El 300. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 3, At minimum,glazing is 3mm annealed-11 mm airspace-3mm annealed-2mm PV13 Interlayer by to the structure. The host structure is the responsibility of the architect or engineer of record for the DuPont-3mm annealed. project of installation. 4. Use structural or composite shims where required. This schedule addresses only the fasteners required to anchor the window to achieve the rated design pressure up to the size limitations noted. It is not intended as a guide to the installation process and does "ROACf ENGINEER, DATE: 3737 Lakeport Blvd not address he sealing consideration that may arise in different wall 08/13/2014 likh T ',(AL U: i uniumons For the complete installation procedure,see the instructions ELD'WEI-I Klamath Falls,OR.97601 packaged with the window or go to D. Vezo NTS Phone: (541)882-314.51 :,,"No,,>7 778," 1 S www.jeld-wen corn/resourcesiinstallation I itEC'ED b� J. Kantola STATE OF Z Premium Atlantic Vinyl Impact Single Hung Window DISCLAIMER: W This drawing and its contents are confidential and are riot to be 0 T No reproduced or copied in whole or in part or used or disclosed to others // PD008729 rft , E except as authorized by JELD-WEN Inc. E N.k�d4' a �11AIIT�;A*11 A11111111-1,11(�111 398 d.. t. 338 11'FPJT1F1 AW4 �"'6-3875- -F-BC 00 m--'v NCrL21 BUILDING DROPS Date: 0 : 30 4 e Report NoDate: : 3094 A Perfect Solution in Every Drop Certificate of Authorization:29578 Manufacturer: JELD-WEN,Inc. Product Category: Windows Product Sub-Category: Single Hung Compliance Method: State Product Approval Method (1)(a) Product Name: Premium Atlantic Vinyl Single Hung—Impact (Impact) 36"x 72"(O/X) Scope: This is a Product Evaluation Report issued by Hermes F. Norero,P.E. (FL(1 73778)for JELD-WEN,Inc. based on Method 1a of the State of Florida Product Approval, Department of Business and Professional Regulation -Florida Building Commission. Hermes F. Norero,P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions NCTL210-3875-1413C,signed and sealed by Hermes F. Norero, P.E. (FL#; 73778)for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the current Florida Building Code and does not require an impact resistant covering. 4. Site conditions that deviate from the details of drawing NCTL210-3875-1-FBC require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions NCTL210-3875-1-FBC for size and design pressure limitations. Hermes F. Norero, P.E. Florida No. 73778 Page 2 of 4 BUILDING DROPS Date: 08/ 30 4 :.s Report No: 3094 ' A Perfect Solution in Every Drop Certificate of Authorization:29578 Quality Assurance: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a quality assurance program audited by an approved quality assurance entity through National Accreditation and Management Institute(FBC Organization#:QUA 1789). Performance Standards: The product described herein has been tested per: TAS 201-94 0 TAS 202-94 0 TAS 203-94 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories NW (FBC Organization#TST9341) Report#: NCTL-210-3875-1, Report Date: 4/18/2013 2. Certification Agency National Accreditation and Management Institute (FBC Organization#:CER 1773) 3. Material Certification Miami Dade RER—Product Control Section NOA E.I. DuPont De Nemours&Co., Inc.: PVB Interlayer 4. Material Certification Miami Dade RER—Product Control Section NOA Quanex Building Products:PVC Extrusions Hermes F. Norero, P.E. Florida No. 73778 Page 3 of 4 BUILDING DROPS Date: 0 : 30 4 Report No: 3094 t A Perfect Solution in Every Drop 0.~ Certificate of Authorization:29578 Through Frame Installation: 1. Approved anchor types and substrates are as follows: A. For concrete (Min.f'c= 3000 psi)or masonry substrate (Min. f'c=1500 psi)where one by(1X), non-structural,wood bucking is employed, use(1)3/16"diameter ITW Tapcon type concrete screw anchors per location of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. B. For concrete (Min.f'c=3000 psi) or masonry substrate(Min.Fc= 1500 psi)where wood bucking is NOT employed,use (1)3/16"diameter ITW Tapcon type concrete screw anchors per location of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. C. For steel substrate, use (1)#8 Tek Screw type steel frame (min.18ga.)anchors per location of sufficient length to achieve minimum three threads of penetration beyond steel structure. Nail Fin Installation(Where applicable): A. For wood substrates(Min.S.G.=0.42)use(1)#10 Wood Screw type installation anchors per location of sufficient length to achieve a minimum embedment of 1.50" into the wood substrate. Refer to Installation Instructions(NCTI-210-3875-1413C)for anchor spacing and more details of the installation requirements. Design Pressure: Design Pressure Positive 65 PIF { Negative 70 PSF Hermes F. Norero P.E. Florida No. 73778 Page 4 of 4 NOTICE OF PRODUCT CERTIFICATION v CERTIFICATION NO: N1011567.04-R3 DATE: 05/23/2013 NCI CERTIFICATION PROGRAM: Structural COMPANY: JELD-WEN t,F�r,.5 CODE: 1822-1 DaO REVISION DATE: 01/13/2017 To verify that the"Notice of Product Certification"is valid,please visit www.NAMIC'ertif ication.com to assure that the product is active and currently listed.This certification represents pn)duct con fimnity to the applicable specification and that certi lication criteria has been satisfied. A NAM1 approved certification label must be applied to the product to claim certification StatuS. Please review and advise NAMI ifall y corrcetions are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION JELD-WEN "Premium Atlantic Vinyl Single Hung(5100)" 3737 Lakeport Boulevard Impact Rated Vinyl Single Hung Window Klamath Falls,OR 97601 (]:in or f=lange Installation) ('on 1 iglu,16011:O.'x Glaring: IG-1,8"Annealed Glass%Lanrinate- 1/8"Annealed Glass/0.090"I'VB Interlaver by Dul'011ti 1/8"Annealed Glass or IG-1%8"Annealed Glass!Laminate- 1.18"annealedGfass/0.090"Sentry(las Plus by DuPont' 1 8"Annealed Glass Franco: W-914nun(36") 1-1-1829nnn(72") Sash: W-8451nnl(33-25") 11-883nnn(34.75") SPECIFICATION PRODUCT RATING TAS 201/202/203-94 Design Pressure: +65/-70 psf Large Missile Impact Rated Product Tested By: National Certified Testing Laboratories Report No: NCTL-210-3875-1 Expiration Date: April 30, 2025 Administrator's Si-nahtre: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Haves,VA 23072 Tel: (804) 684-5124 Fax: (804) 684-5122 398 E. Dania Beach Blvd. BUILDING DROPS Suite 338 Dania Beach, FL 33004 t '3; A Perfect Solution in Every Drop 954.399.8478 PH Certificate of Authorization:29578 954.744.4738 FX contact@buildingdrops.com 119-odmet k"N"flu"Ifl n Report Of JELD-WEN, Inc. Premium Atlantic Vinyl Single Hung - Impact fir Florida Product Approval kwport No. 3094 Current Florida Building Code Method: 1 — A (Certificate) Category: Windows Sub — Category: Single Hung Product: Premium Atlantic Vfigl Single Hrrng -Impact Material: PVC Product Dimensions: 36"x 72"(O/a) Prepared For: .#E LD-NNI ::N. 1110. 3737 Lakeport Blvd. 11ittt ails Y.tals. OR 97601 Prepared by: ``,�tt„t,rrrr�� ILcrtrt 's F. Not-cl-o. l'.1”. ��`��S F. 0�/Y' � Florida Professional Engineer 41 73778 Date: 08/11/2014 ��:'�\G.• 1'� 7& : O Contents: Evaluation Report Pages 1 4 "10 .; T TE F of C� rrt�t►t Hermes F. Norero,P.E. Florida No. 73778