Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval- single hung
M IAM 1•QADE MIAMI-DARE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE OA www.miamidade.eov/economy CGI Windows and Doors,Inc. 10100 NW 251h Street Miami,FL 33172 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone. DESCRIPTION: Series"Sentinel 110" Aluminum Single Hung Window—L.M.I. APPROVAL DOCUMENT: Drawing No. W10-03, titled "Series Sentinel 110 Alum. S.H. Wdw. (L.M.I./S.M.I.)", sheets 1 through 9 of 9, dated 02/02/10, with revision D dated 09/29/17, prepared by Al- Farooq Corporation, signed and sealed by Javad Ahmad, P.E., bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade A Product Control Section. SILE IMPACT RATING: Large and Small Missile Impact Resistant. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively_affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 15-0512.10 and consists of this page 1 and evidence pages E-1,E-2 and E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez,P.E. NOA No. 17-1018.08 MIAMI•DADE COUNTY Expiration Date: September 22,2020 ® �I Approval Date: December 21,2017 ly,12 �1' Page 1 CGI Windows and Doors,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA No.10-0510.11) 2. Drawing No W10-03,titled"Series Sentinel 110 Alum S.H. Wdw. (L.M.I./S.M.I.)", sheets 1 through 9 of 9, dated 02/02/10,with revision C dated 04/10/15,prepared by Al-Farooq Corporation,signed and sealed by Javad Ahmad,P.E. B. TESTS 1. Test reports on: 1)Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC,TAS 201-94 3)Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings and installation diagram of a series 7500 PVC fixed window,to qualify DuPont"Butacite"PVB interlayer, Duraseal(& and Super Spacer(& insulating glass spacer,prepared by Certified Test Laboratories,Test Report No. CTLA3056 WA, dated 03/03/15, signed and sealed by Ramesh C. Patel,P.E. 2. Test reports on: 1)Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC,TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of a series 7400 PVC project out window,to qualify DuPont`Butacite"PVB interlayer,Duraseal(9 and Super Spacer(&insulating glass spacer,prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WB, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E. 3. Test reports on: 1)Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2)Large Missile Impact Test per FBC,TAS 201-94 3)Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings and installation diagram of a series 238 aluminum fixed window,to qualify DuPont"Butacite"PVB interlayer, Duraseal®and Super Spacer®insulating glass spacer,prepared by Certified Test Laboratories, Test Report No. CTLA 3056 WC, dated 04/16/15, signed and sealed by Ramesh C. Patel, P.E. 4. Test reports on: 1)Air Infiltration Test,per FBC, TAS 202-94 2)Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3)Water Resistance Test,per FBC,TAS 202-94 4)Large Missile Impact Test per FBC,TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test,per FBC 2411.3.2.1,TAS 202-94 along with marked-up drawings and installation diagram of a series"Sentinel" aluminum single hung window,prepared by Hurricane Test Laboratory, LLC,Test Report No. HTL-0080-0101-10, dated 02/03/10, signed and sealed by Vinu J. Abraham, P.E. (Submitted under NDA No.10-0510.11) Manue PV- 018.08 .E. Product Controlner NOA No. 1 Expiration Date: September 22,2020 Approval Date: December 21,2017 E-1 CGI Windows and Doors,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC-5th Edition (2014), dated 09/08/14,prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No.14-0915.06) 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0916.11 issued to Kuraray America,Inc.for their "SentryGlas® (Clear and White) Glass Interlayers" dated 06/25/15, expiring on 07/04/18. 2. Notice of Acceptance No. 14-0916.10 issued to Kuraray America,Inc. for their "Butacite®PVB Glass Interlayer"dated 04/25/15,expiring on 12/11/16. 3. Notice of Acceptance No. 14-0423.15 issued to Eastman Chemical Company(MA) for their"Saflex CP–Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 06/19/14, expiring on 12/11/18. 4. Notice of Acceptance No. 14-0423.17 issued to Eastman Chemical Company(MA) for their"Saflex Clear and Color Glass Interlayers"dated 06/19/14, expiring on 05/21/16. F. STATEMENTS 1. Statement letter of conformance, complying with FBC-5th Edition(2014), and of no financial interest, dated 08/26/14, issued by Al-Farooq Corporation, signed and sealed by Javad Ahmad,P.E. (Submitted under previous NOA No.14-09-15.06) 2. Laboratory compliance letter for Test Report No. HTL-0080-0101-10, issued by Hurricane Test Laboratory, LLC, dated February 03, 2010, signed and sealed by Vinu J.Abraham,P.E. (Submitted under NOA No.10-0510.11) 3. Test Proposal for the qualification of Butacite®PVB glass interlayer by DuPont as well as Duraseal®and Super Spacer®Standard warm-edge flexible insulating glass spacers, dated December 16,2014,issued by RER,Product Control Section, signed by Jaime Gascon, Supervisor. G. OTHERS 1. Notice of Acceptance No. 14-0915.06, issued to CGI Windows & Doors for their Series "Sentinel 110"Aluminum Single Hung Window-L.M.I. approved on 02/05/15 and expiring on 09/22/20. —Wawu ;�C44 Manueer P.E. Product Coat of aminer NOA N . 17-1018.08 Expiration Date: September 22,2020 Approval Date: December 21,2017 E-2 CGI Windows and Doors,Inc' NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No W10-03,titled"Series Sentinel 110 Alum S.H. Wdw. (L.M.I./S.M.I.)", sheets 1 through 9 of 9,dated 02/02/10,with revision D dated 09/29/17,prepared by Al-Farooq Corporation,signed and sealed by Javad Ahmad,P.E. B. TESTS 1. None C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 61' Edition (2017), dated 09/29/17,prepared by Al-Farooq Corporation,signed and sealed bZ Javad Ahmad, P.E. D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0916.11 issued to Kuraray America,Inc.for their "SentryGlas® (Clear and White) Glass Interlayers"dated 06/25/15, expiring on 07/04/18. 2. Notice of Acceptance No. 16-1117.01 issued to Kuraray America,Inc.for their "Trosifol®Ultraclear, Clear and Color PVB Glass Interlayers"dated 01/19/17, expiring on 07/08/19. 3. Notice of Acceptance No. 17-0712.03 issued to Eastman Chemical Company(MA) for their"Saflex CP-Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 09/07/17,expiring on 12/11/18. 4. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company(MA) for their"Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. F. STATEMENTS 1. Statement letter of conformance,complying with FBC 51h Edition(2014),with FBC 61 Edition(2017),and of no financial interest,dated September 14,2017,issued by Al- Farooq Corporation,signed and sealed by Javad Ahmad,P.E. G. OTHERS 1. Notice of Acceptance No. 15-0512.10, issued to CGI Windows&Doors for their Series"Sentinel 110"Aluminum Single Hung Window-L.M.I., approved on 08/06/15 and expiring on 09/22/20. Manuel P.E. Product Co ntr E miner NOA No. -1018.08 Expiration Date: September 22,2020 Approval Date: December 21,2017 E-3 53 I/W 52 1/8' 52 1/0- FLANGE B'FIANCE WIDTH BUCK WIDTH BUCK WIDTH 47 7/16' 47 7/16- 47 7/16' o D.LO. (FIX LRE) FALSE MUN INS D. (FIX. LITE) FALSE MUNTINS D.LO. (FIX. LITE) z RF 3 2 -(SURFACE APPLIED APPLIED) n 6'MAX. 018'## OPTIONAL ) 5 1/2'MAX. 20 9/16' ## (OPTIONAL 20 9/16' 0 �' J MAX. 5 1/2'MAX. MAX. ## W HEAD/SILL A HEAD/Sql HEAD/SIU A7HEAD/SILL HEAD/SILL HEAD/SILL Q a 4 6 ERS CORNERS 7 W yW I I 11 p II Il �' ii ii � ii ii 0 u n F _#__ �____= a o c C W W O h 5 n Z n Y n Y Q W my V !E n s n ii Z% ii \w • -__--''11 �J11 u _ 1 n x n 1 rn _ _1II me n tL n o n 4I===== 'R p C ii ii � n J II 11 n t n J II II i U II II 4 II " m C7 11 11 11 II C a I 6 ii T11 " b y O Ci 47 7/16' z FALSE MUNTINS 47 7/16' m j D.LO.(VENT) m-' D.LO. (VENT) \ (SURFACE APPLIED) O.LO.(VENT) z C O \ u O O=N 50 1/4' 50 1/4' 50 1/4' n O1 N VENT WIDTH VENT WIDTH VENT WIDTHC4Ed 0 M FLANGE & FLANGE ADAPTOR FRAME EQUAL LEG FRAME FIN FRAME Z c z J SERIES SENTINEL 110 ALUMINUM SINGLE HUNG TPINDOW H 3 0 FE NOv DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER TYPICAL ELEVATION , � oA CHARTS SHOWN ON SHEET 2. O APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE COMBINATIONS OF S.H./S.H. OR SINGLE HUNG WDW. WITH OTHER MIAMI-DADE COUNTY ** C APPROVED WINDOWS USING MIAMI-DARE COUNTY APPROVED MUWONSgg IN BETWEEN. CENTER ANCHOR REQUIRED WHEN 8 R LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION APPROVAL SPACING EXCEEDS 20 9/16" WILL APPLY TO ENTIRE SYSTEM. m b THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2014(5TH EDITION)/2017 (6TH EDITION)FLORIDA _ LAMINATED GLASS BUILDING.CODE INCLUDING HIGH VELOCITY HURRICANE ZONE(HVHZ). INSULATING LAM. GLASS ^ 1BY OR 21TY WOOD BUCKS h BUCK FASTENERS BY OTHERS. MUST BE o n' - DESIGNED AND 14STALLM ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS LARGE MISSILE IMPACT °-o$ S B To THE BUILDING STRUCTURE SMALL MISSILE IMPACT 5 o m o ANCHORS SHALL BE CORROSKIN RESISTANT,SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF'S INSTRUCTIONS.SPECIFIED EMBEDMENT TO BASE A11 11111 1/T7jA' MATERIAL STALL BE BEYOND WALL DRESSING OR STUCCO. ♦`�J.fl � ,Vi o A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. •' N' ALL SHIMS TO BE HIGH IMPACT,NON-METALLIC AND NON-COMPRESSIBLE WG (�•e V'^.�C s MATERS INCLUDING BUT NOT UMRED TO STEEL/METAL SCREWS.THATMATERIALS _ 70692 COME INTO CONTACT WITH OTHER DISSIMILAR MATERIASHALL MEET THE IPODUCTREVUM } tt REQUIREMENTS OF THE 2014/2017 FLORIDA BLDG. CODE Q ADOPTED STANDARDS. •n—piyim.0h do Fbxf! THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION uddwg Code •/A�. FOR A SITE SPECIFIC PROJECT.i.e. LIFE SAFETY OF THIS PRODUCT.ADEQUACY AImptan"tJo IB `�`� ATE OF •�!(A\ drowing no. OF STRUCTURE RECEIVING THIS PRODUCT AND SFALNC AROUND OPENING FOR E Detc ORIF•.• ♦ W�O_O� WATER INFILTRATION RESISTANCE ETC. �AL CONDRIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, 3y Ss/ \♦♦ AND TO BE REVIEWED BY THIS OFFICIAL *Aivni adcPiaduN 'VAATl11 111\71♦ Sheet 1 Of 9 EQUAL LITES WINDOWS UNEQUAL LITES WINDOWSC2 DESIGN LOAD CAPACITY-PSP DESIGN LOAD CAPACITY-PBP - � FLANGE DDIS. BUCY IS. GLLTS TYPES'A'k'ACUM1'6TYPES'B'k'BI' FLANGE DW. BOCK DU19. IfAZ.TOP TYPES TYPES'A'k'11'9IL45 TiP 'B'k'B1' I O WIDTH HEIWR WIDTH HEIGHT EKr.(+) 1Kr.(-) E%T.(+) INT.(-) W1DTHWIOM HDGW 'A'DIM. DG.(.) INT.(-) EXT(+) 1M.(-) 18 -t/e• 75.0 750 80.0 85.0 53-1/B' 7' S2-t/e" 75• 36-1/4• S 7 80.0 a5.0 26-1/2" 25-1/2• 75A 75.0 80.0 55.0 49' 79" 48" 7a' 39-1/4• 75A 75.0 80.0 85.0 O Z M q 6 37" 26• 36" 25• 75.0 75.0 80.0 85.0 26-1/2• 25-1/2• 70-5/8' 75.0 75.0 Bo.D 65.0 f Z(p d 49• 48• 75.0 75.0 WO 85.0 31" 30• 63-5/e' 75.0 75.0 804 S" 53-1/8' 52-1/8• 75A 75.0 804 85.0 33• M. 32' 84' 80' a0A B5.0 Q O (V C 19-1/a" 18-1/8' 75.0 75.0 80.0 85.0 37" 36• 63-1/2' 75.0 75.0 80.0 85.0 �• w 26-1/2" 25-1/2" 754 75.0 8DA 85.0 43' 42' 45-1/{' .0 75.0 80.0 37' 36-3/B' M. 37-3/B• 78A 75.0 80.0 55.0 41 Q H 49• b' 75.0 75.0 80.0 65.0 p 53-1/8• 52-1/8• 75.0 75.0 80A 85.0 WIDTH c�2 av O a <8 19-1/a• 18-1/8• 75.0 75.0 BOA Ss.o O 11 z6-1/2" 25-1/2" 75A 75.0 80.0 55.0 LL ir U)OJ 37' 50-5/6" 36• 49-5/8• 75.0 75.0 80.0 85.0 t9• 48' 73.0 75.0 50.0 BS.O LL 2: 53-I/a• 52-1/8• 75.0 75.0 80.0 BSA J O X0{61`� 19-1/8' 18-1/8. W26 8-1/8• 75.0 75.0 a0.o 0.5.0 Q W O F 26-1/2' 25-1/2' 75.0 75.0 SOA 85.0 V •� 37" 53' 36' 6Y' 75.0 75.0 80.0 6510 T �? 49' 48 ' 75.0 76.0 a0A 65A V! 53-1/e• 52-1/e0 75.o 750 82-0 es.o 19-1/8' 75.0 7S0 BOA B5A 2 C) I 26-1/2• 25-1/2" 75.0 75.0 a04 85.0 r- r' C 37' 78" 36' 75• 75.0 75.0 80.0 SSA UNEQUAL LITES (ORIEL TYPE) K• 48' 78.0 75.0 BOA 85.0 ; 53-1/8• 52-1/B' 75.0 75.0 SOA BSA = O 19-1/6• 18-1/8• 75A 75.0 00: SSA w p W 25-1/2• 25-1/2' 75A 75.0 SOA SBA 37' 85" 36' 94" 75.0 75.0 00A 0.5.0 C to 46-1/2' 45-1/2' 75.0 75.0 80.0 MO BUCK DIMS )!•TTP. o O SN c 2 O M V n WIDTH € C Z FLANGE FRAME 3 0 N FLANGE DIMS �I W t9 0 5 H BUCK DIMS 0 F-T EQUAL LEG FRAME z 8 BUCK DMS EQUAL LITES yo a�as FIN FRAME m u At1111 1111/// 5�% BUCK DIMS �•••. ' s PRODUCTREVISPD - n NOTE: �«*drms wi h Ws F7uWa 8 GLASS CAPACITIES ON THIS SHEET ARE 7dAo 1dmE Cone BASED ON ASTM E1300-09 (3 SEC. GUSTS) FLANGE ADAPTOR FRAME F p"a�H�I <! 0 8. � �' OF druWinyo Dc AND FLORIDA BUILDING COMMISSION FLANGE DIMS ., •..... DECLARATORY STATEMENT OCA05-DEC-219 ti c nkPoa9a '��7i1�"�1` sheet 2 of 9 1/8'ANN. GLASS 1/8'HEAT STREN'D GLASS .075' Interlayer .075'Interlayer O Saflex CP With PET Core Saflex CP With PET Co. o By 0'Eastman Chernieal Co.' R'Eastman Chemical Co.' Z m ; .090' Interloyer 090'Interlayer Saflex Clear And Color Glass Saflex Clear And Color pFass $gx 0'Eastman Chemical Co' By 'Eastman Chemical Co.' Q a 6 .090'Interlayer 090'Interlayer 0 00— U SentryGlos Sentrygas CL N OAR Kumray America, Inc' By'Kuroray America, Inc.' O ¢ OR 090'Interloyer 090'Interlayer 0 t'm r Troeifol PVB Trosifol PVB 0 0O By 'Kuromy America, Inc.' By 'Kuroray Americo, Inc! Ga� o 8 GLASS ANN. C5 �+ 1/8'HEAT SfREN'0 GUESS 0 = yN 10, SILICONE =vvm�� Q Ir z tl 3 M7 GE 1200 �] M1 LL W M.o cs DOW CORNING 899 c+ DOW CORNING 899 r Z n DOW CORNING 995 DOW CORNING 995 J O Q 3mf O EB 0 0 a Ea a Ee y N fw, w � x M4 AT 1/4 POINTS ON LRES M4 AT 1/4 PORM ON LITES U i W WIDER THAN 36' W WIDER THAN 36' C GLASS TYPE 'A' GLASS TYPE 'R ; vi 5/16'OVERALL LAM. GLASS 5/16'OVERALL LAA.GLASS (L.M.I & S.M.I.) y O0r, 0 u 1/8'ANN.GLASS 1/8'HEAT SfREN'D CLASS N .075'Interloyer .075'Interlayer D F N Saflex CP With PET Core Saflex CP With PET Core By'Eastman Chemical Co.' By 'Eastman Chemical Co.' Ed 3: n OR OR z 0 3 n 090' Interlayer 090'Interloyer C _ Sane. Clear And Color Glass Saflex Clear And Color Glass N 3 Z By 'Eastman Chemical Co.' By 'Eastman Chemical Co.' O= OR OR 1/4'AR SPACE .090' Interlayer 1/4'AR SPACE .090'Interlayer w U O J SentryGlos SentryGlas h By 'Kuraray America, Inc.' By 'Kumroy America, Inc.' 0 1/8'ANN. GLASS OR OR 090'Interlayer 1/8'HEAT STREN-D GLASS .090'Interlayer Trosifol PVB Trositol PVB c By'Kuroray America, Inc.' By 'Kuroroy America, Inc.' E P x Q a 1/8'ANN. CLASS 1/8' HEAT STREN'D GLASS SILICONE SILICONE rn GE 1200 = y GE 1200 DOW CORNING 899 DOW CORNING 899 \O M7 DOW CORNING 995 \O Ml DOW CORNING 995 PRODUCT REVUED m ckh 60 Fbdb c oXL EDGE SPACER XL EDGE SPACER ;3uildogc.& a o„ C o S o$ 5T. STEEL BY'CARDINAL' ST. STEEL BY'CARDINAL' 4cccptence No � o< m OR OR F..Pimrinn Dee c 0 DURRASEAL BY'OUANLX' a0 DDURRASEAL BY'OUANEX' W E9 SUPER SPACER BY'Ql1ANEX' W E9 SUPER SPACER BY 'QUANEX' rni sde Prow `���PJI'”.:..�.,7'/Z�q���i� •� W M4 AT 1/4 POINTS ALL SIZES M4 AT 1/4 POINTS ALL SIZES GLASS TYPE 'Al' GLASS TYPE 'Hl' 0.70'OVERALL INSUL LAM.CUSS 0.70'OVERALL INSUL. LAM. GLASS '� a'— -- ---- (L.M.I ONLY) tv; OF l{A� drawing no. (S.M.I.) OR101;.•' IN ORDER TO QUALIFY FOR SMALL MISSILE IMPACT RATING0N EXTERIOR EXTERIOR PLY OF GLASS TYPE'Al' & 'B7' MUST BE TEMPERED. V ArIA`1\\\\` sheet 3 of 9 O ,T_EUV. DRS FLANGE & FLANGE ADAPTOR FRAME113Y FOR SPACING m�IrV SEE ELEV. WOOD BUCK METAL 1 .\ I STRUCTURE o A . . '�4'a• �..•' a. •DISE �\� TVPKSIL ANCHORS Oo � \ Ij 11 MWAI-UWE COVNTY APPROVED T1I Z FSCE 0FOR SPACING IMULLION B MULLION ANCHORS ESEPARATE NOAEDGE DST. OROma ;aI � U 'EDGE DIST. I I 0�R O -- 0 t m n � I i ___- olJd ()& \ TYPICAL ANCHORS S5 M2 TYPICAL ANCHORS 0 N.3 ti 2 SEE ELEV. SEE ELEV. Q,'C Z O H FOR SPACING FOR SPACING Q W E �Z'A us WOOD BUCKS AND METAL STRUCTURE NOT BY CGI WDW. <z�°rt 0 2 3j= —ro —1 MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. TYPICAL ANCHORS: sEE ELEv. FOR SPACING OWEEP LOCK PTIONAL TO 2 3�" fu=125 KSI.fy=100 10) v V ' EGRESS LOCK 1/4" DIA. ULTRACON BY �ELCOFu-177 KSI.Fy-155 KSI) � '^ AT SILL `. INTO 28Y WOOD BUCKS OR WOOD STRUCTURES o 1-1/2" MIN. PENETRATION INTO WOOD (MEAD/SILL/JAMBS) ; o = o © THRU 1BY BUCKS INTO CONC. OR BLOCKS v p w 1-1/4' MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) 1- C1 Et WHEN USED THE MIN. WOOD BUCK 1-1/4" MIN. EMBED INTO BLOCKS (JAMBS) o O N o DEPTH SWILL BE 2)(1". THE USE OF DIRECTLY INTO CONCRETE OR BLOCKS FW 1 DEEPER OR BEVELED WOODBUCKS IS 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) d o NM n i PERMITTED. 1-1/4' MIN. EMBED INTO BLOCKS (JAMBS) 0 Z 4 1 ! #14 CMS OR SELF DRI I IN. SCRIENS (GRADE 2 CRS) 3 O INTO MIAMI—DADE COUNTY APPROVED MULLIONS J W OR iE INTO METAL STRUCTURES (HEAD/SILL/JAMBS) '9 z i!i (3) THREADS MIN. PENETRATION BEYOND SUBSTRATE � ALUMINUM: 1/8" THK. MIN. (6063—T5 MIN.) e t 0 1 STEEL 1/8" THK. MIN. (Fy = 36 KSI MIN.) x^ u ! (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) 0 gg 7Z 13 Y Q ' lYPlf`dl F71Y.F MSTA/J_(`F C q p$T5Q� g1F S4 1 INTO CONCRETE AND MASONRY = 2" MIN. 5g5 ' INTO WOOD STRUCTURE = 1" MIN. 1 INTO METAL STRUCTURE = 3/4" MIN. E6 ass i WOOD AT HEAD. SILL OR JAMBS SG - 0.55 MIN. M9 _ CONCRETE AT HEAD, SILL OR JAMBS f•c =3000 PSI MIN. g g C-90 HOLLOW/FILLED BLOCK AT JAMBS fm 2000 PSI MIN. m o OI PRODUCT REVISEDc C nc o,mplying with tAs FlocfdA ` ett\111111///7j7j 1 1 Bcccpun«M.t -/010'08 a: �� JW '' T •c �P.•v •.,. . d _ Expirelion tMe jg� EDGE OISf:~' �• :• \ ..� I I IYPIGIL AN 7 • SEE ELEV. OF FOR '• � drawing a no. ANCHORS FOR SPACING SEE ELEV. O!I-t0t•,' �' W10-03 `wDOD BUCK FOR SPACING '''''A�111t ``` sheet 4 of g 1/4'MAX. BUCK WIDTH 1/4•MAX. FLANGE & FLANGE ADAPTOR FRAME SHIM SHIMS 0 O1 1l m 3 TYPICAL ANCHORS TYPICAL.ANCHORS SEE ELEV. S6 S5SEE ELEV. " < FOR SPACING 1 1 MB . . FOR SPACING Q 1 <n o.• FLANGE ADAPTOR FRAME W p 0 CCL g :. METAL STRUCTURE S — - 1' .4• G>M aa¢m gg R O Nyp A BY W N O EXTERIOR TwOpp BUq(S I __= LL z m 1 Jt oma � DA-OPG. O N 1/4'MAK. BUCK WIDTH i SHIMS TYPICAL ANCHORS O W ! SEE ELEV. IYPIGIL ANCHORS I rn vi FOR SPACING SEE ELEV. j O V FOR SPACING = O Cil • _ _____— _ I I vi r � � WDDo WOOD STRUCTUR C Z 1 B WOOD BUCKS 1 N � O .NMI-DADE COUNTYo sQt �w APPROVED MULLION m o SEE SEPARATE NOA 1/2•TYP. O ¢ q `u F BUCK WIDTH BI1CIf WIDTH m g INTALLATION DETAILS SHOWN ON PAGES 4 1, AND 5 APPLY TO BOTH FLANGE FRAME AND FLANGE ADAPTOR FRAMES. m„' I II - 88d8 1 I HRODUCr REV1S® —0yul6 with dw Noise <m 1 I chniding CO& O I5zlOTG OS ��,N a I�iAAA - ^�pirationDate I I ��` v� ��� I •1 cow No 7p= -014 K 1•FH. SMS. Is •oarorp` W10-03 oil' �� sheet 5 of g TYPICAL ANCH raoo eliafc FOR SPACING ORS `M�� U EQUAL LEG FRAME y.V STRSEE ELEV. UCTURE ,.I x SEE EI ANCHORS • `d�. ..•ObT•„ SEE ' •p • a.'' .... • a. • ••.' FOR SPACING g 6 II I MWA-DADE COUNTY MULLION& MULLION AANHI II QESE Fz M 9 N E DIST. 3 0 I I I SEE SEPARATE NOA II H W I I II I Q f Z � a :.... n7 f � EDGE DIST. I tl 0 II iI Cp�U m U M3 E7 EB TYPICAL ANCHORS TYPICAL ANCHORS Q� M g M2 SEE ELEV. SEE ELEV. Q f p Q .� FOR SPACING FOR SPACING O 5 TYPICAL ANCHORSEi MIAMI-DARE COUNTY �'C Z O FOAPPROVED Mi Q W N LL c M9 �& MUWON ANCHORS Z 0 q X SEE SEPARATE NOA 0 1/4� BUCK WIDTH BUCK WIDTH BUCK WIDTH Z Pqf Q J SHIMS Q M nl f .v I Fr--i� a SWEEP LOCK 1 1/4' OPTIONAL TO _ _ _Emp E8 t EGRESS LOCK AT SILLra — 1 W 0 v �Of I '0 N IL -J I N x o O2N O F1 t v Q m /14 Xi FH. SNs. G+j O M n 10 N p !E O _ F5.I U 2'M EQUAL LEG FRAME CAN BE INSTALLED DIRECTLY o INTO WOOD. CONCRETE OR METAL STRUCTURES c I WfIHOUT THE NEED OF A W000 BUCK. c iI - 2 3/a*Mel. 12 e I S4 ' - 1 E6 23/8,MIN. �_:; a trwcAl ANCHORS 0 o_ S e ry M9 _—� * .' 5 SEE ELEV. .S'gig 9 8 O PRODUC�f REV1y6D FOR SPACING << 14 �� "S,COQ1PIYm8 with1lM Fhb AnmR,, No f -1018.08 ```�711n AH tAAA�� o E2 Expi—ion rh u1 �� J'`......... Mianei udr Product CaAvr>$ �• WHEN USED THE MIN. WOOD BUCK �/ ND yy DEPTH SHALL BE 2%'. THE USE OF `EDGE \ TYPICAL ANCHORS PERMITTED.E�� BEVELED WOODBUCKS IS ATE OF droMiny no. sEE ElEV. !tOa+W:.• W10-03 FOR SPACNG '% ` ` MOOD BUCK ''AA A� Ij1T�`' sheet 6 of 9 1m6 EXTERIOR SRF Kc Hyl mp N 0 (0—) O D.L OPG. O 0 A m zP a� x OPTIONAL ._.._.._.._.._. AFI� 11 � yy n�0 O ll� N j P VENT HEIGHT chi 8 1/Y MIN. BUCK HEIGHT 1/2'MIN. 1/4.MAX. 1/4"MAX. GAP CAP 7MM m 1 1/2 + - Z �N _0 R. o 0 0 x WH � Z => 9 �n1 u1 1 0. dot. 02-M-10 revisions: SERIES SENTINEL 110 ALUM S.H. WOW. (LM.I./S.M.I.) AL-FAROOQ CORPORATION rC a DO .1.1 BSCrI 1011 ENGINEERS h PRODUCT DEVELOPMENT A OO.1J.10 Iq fIYNOE 1110 9NFFf / CGI Windows and Doors, Inc. V m 9 date UPWtD m 9011 R+C 9360 SUNSET DRIVE,SURE 220 10100 N.W. 25TH STREET MIAMI,FLORIDA 33173 p, � IF C 04.10.10 Iq TED 1118 91EFf (C.)26-6 78O � o os zo.n tR941t0 mz5n rec MIAMI, fL. 33172 TEL.(ao�26ae1oo FA%.(306)284-0970 m W o thk Ey: TEL (305)593-6590 FAX.(305)693-6592 COMP-ANL W70-03CGI 17W1 PART / QUANTITY DESCRIPTION 11ATERIAL IdANF./SUPPLIER V /REMARKS U E1 CGI-100 1 FRAME HEAD 6063-T6 �� o E2 001-101 1 FRAME SILL _--_. 6063-T6 E3 COI-102 2 FRAME JAMB W63-T6 E4 CGI-103 1 MEETING RAIL 6063-Ts FS CGI-104 1 LOCK RAIL 8063-T6 E6 CGI-105 1 HANDLE RAIL 6063-TB - 1�o`� V E7 CGI-106 2 SASH RAIL 6063-T6 - 0 IL Lu N S E6 CGI-107 AS READ. 3/16'GLAZING BEAD 6063-T5 - G E9 CAT-108 AS READ. 0.700'GLAZING BEAD _ 6063-75 LL E10 CGI-1099 AS REOD. FRONT FLANGE ADAPTOR 6063-Ts - V p ui 1.I E71 Ctl-1t0 AS REOD. NAIL FIN ADAPTOR 6063-75 - O Q Q Q g E12 CGI-135 1 FIANCE FRAME HEAD 6063-76 E13 02-136 2 FLANGE FRAME JAMB 6083-TS E14 CGI-137 1 FLANGE FRAME SILL 6063-T6 - w y 6 E17 CGI-605 OPTIONAL SCREEN FRAME 8063-T5 - LL Z O QW�f � M1 CGI-362V AS REOD. GLAZING BULB VINYL(WROMETER 75-80 SHORE A) PVC M2 OGI-111 OPTIONAL SCREW COVER PVC PROTOTYPE OR EOUN. 113 CGI-112 AS REDD. EQUAL LEG COVER/SHIM,3'LONG AT ANCHOR LOCATIONS PVC i M4 - 2/LTTE SETTTNG BLOCKS EPOM DUROMLIER 8025 SHORE A M9 SUPER BOOST 2/WDW. SPIRAL BALANCE - BSI OR EQUIV. I n M10 - 2/WDW. BLOCK/TACKLE BNANCE - BSI OR EQUN. C 'n Mil W23201NG AS REOD. PILE WITH CENTER FIN WOOL ULTRAFAS OR EMM. 3 O M12 COI-129 1/WDW. F0RE55 LOCK ALUM. SULLIVAN 3 M13 CGI-131 2/WDW. HANDLE RAIL END CAP NYLON M&M = O U14 E260IBM - D BULB-T SLOT PVC ULTRAFAB OR EOIAV. r M75 CGI-133 4/WDW. SASH W0tx5PIRAL BALANCE) NYLON M&M to M78 Cd-130 2/WOW. SASH TOP GUIDE(SPIRAL BALANCE) NYLON M&M a O x N c M17 A30730401-32 1/WOW. CAM LOCK ZINC TRUTH OR EQUIV. M16 CGI-132 2/WDW. SASH STOW,2'LONG PVC PROTOTYPE OR WW. cl 03 M y M20 CGI-125 2/WDW. SASH CMI(B/TBAI.ANCE) NYLON M&M Z C) n M21 - 2/WON. B/T BALANCE TACE OUT CLP - BSI OR EQUIV. § O TOO—� M22 146-6 2/WDW. WEEP COVER NYLON AMESBURY OR EQUN w M23 CGI-134 - SILL SPACER PVC PROTOTYPE OR EOUW. ¢ U O . w Ule N S2 2 OR 3/CORNER f 10 X 1 1/4'LG. PHL PK SMS. ST ST.ASSEMBLY SCREW S4 _ 41 WDW. f 8 X 1 2'PH.SMS.ST BALANCE BRACKET SCREW S5 - 2 WOW. 8 X 1'LG. FH. SMS. ST/ST. SPIRAL B.ASSEMBLY Ss - 2/LOCK B X 1 2'I.C. FH.SMS O CGI-133 E CAM LOO( 2 O n g o _ gig 99 1'R0bllCTftEVL� \711111111111/ xs camDlYuR wily bie Plod` \\ i DuildioA Code `\\ ��•���i� o -prat—Doe , g By 7069¢ _ !� Miwru de Prodeel ^ 411 t% TE OF •'�!//�: drawingo no. W10-03 ''�YYII�Aj j111\ sheet 8 of 9 2.505 2.505 -11-.G65u c� � 52 M o P 3 1.745 .fill .811 1.550 1.680 I 0 q w .745 .065 -1 1145 TP. .745 085 I 2 I IYP. .Oso I U 1.015 F� 1.015 fes- L-1.395 A E72 FLANGE FRAME HEAD Et FLUSH FRAME HEAD Et1 NAIL FIN ADAPTER V G N 1.583 1.593 1.007 �-•- a ¢ o oaoo i3w¢ .745 I 0: i a n .065 obs j a w y LL o TVP. iYP. 065 a 2 02 o nP. 2.113 m 3.675 i 3.175 3.175 1.368 1,015 a 1.42s 1.429 VENT TOP CORNER c-_----� L1.220 7.000 .500 - m O n .500 2505 E4 MEETING RAIL FRAME TOP CORNER 2.101 3 n 1.220 E14 FLANGE FRAME SILL 0E2 FLUSH FRAME SILL �//� H 0 w r .500 1.301--{ 1.307 7.043 ,g 'O En 1.785 c',p .065 S2 _ to fn 065 d p N M.065 :t TP. TP. Z U 3 n 2.440 2. 1A15 I 3 Z 4 o ,,,• 7.015 1.015 E5 LOCK RAIL FRAME BOTTOM CORNER I wU VENT BOTTOM CORNER a .745 I ,745 2.195 O 2.846 IF•-2.346 c $ E13 FLANGE FRAME JAMB O FLUSH FRAME JAMB 12 1 892 .490 •120jr 1.043 085 .705 .050 TP. .705�jF-,050 TYP. .. 1 LAM ,.015 e,. a.884HAND RAIL SODUCT REVISED O 5/16 GLAZING BEAD E9 .700" GLAZING BEAD B MYi�� iW FWid4 /1111111/ :\eeepteuce Fd 1.449 1.395 Expiation Dart `� �Q;.•' •qF•••., � N 1 : 1.195 .74 1.450 s j 180 �,, +��--1r.180 m ' Dade Product -[ .293 •050 .060 1.025 085 1.015 .550 050 JJJ ... j O Of r � Browing no. off.•• W10-03 ' O FLUSH FRAME COVER SCREW COVER l"i SASH RAIL Et0 FLANGE ADAPTOR llllt t\�\ sheet yof9 � i