Loading...
HomeMy WebLinkAboutWind Load Calculation RECEIVE© DEC 0 7 2018 ST. Lucie County,Per Property Information Building Information Owner: Kern Sheri Wind Zone: 170 MPH. Address: 12737 S Indian River Drive Exposure Category: C Jenson Beach,FL 34957 Minimum Building Dimension: 25 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 50 60 7 36.0 -39.2 2 Int 34 60 7 36.9 -40.1 3 _ Int _51 61 _ 7 35.9_ -39.1 4 Int 34 60 7 36.9 -40.1 5 Int 24 24 7 37.8 -41.0 6 Int 35 37 7 37.8 -41.0 7 Int 25 56 7 37.8 -41.0 8 Int 25 56 7 _ 37.8 -41.0 9 Int 60 7 37.8 -41.0 10 Int 37 58 _ 7 36.8 -40.0 11 Int 25 60 7 37.7 -40.9 12 Int 24 47 7 37.8 -41.0 13 Int 28 46 7 37.8 -41.0 14 Int 24 47 7 37.8 _ -41.0 15 Int_ 35 _ 69 7 36.5 -39.7 16 Int 98 48 7 34.9 -38.1 - ----.........._._ .......-......._.. -- 17 Int 98 17 7 35.8 -39.0 18 Int 35 69 7 36.5 -39.7 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1