HomeMy WebLinkAboutDrawing Size,
Opening (wx.H) �N '
1 Accordlon�Shutter 63 x 76,9
(Front Window)
2 Accordion.Shutter, -,111I 63 x 62> s-
,(SJde•1Mntlow)
3. Accordion.Shutter ti 63 z 62'r
(side lMndow) 5
4. Accordion Shutter ?
I
Property Information Building Information
(Owner: William Brown Wind Zone: 160 MPH.
Address: 132 N Mediterranean Blvd Exposure Category: B
Port St Lucie,F134952 Minimum Building Dimension: 24 ft.
Mean Roof Height: 15 ft.
Risk Category: 11
{ Design Pressure Calculations
Opening Location 'Device Device Device Max Positive 'IF-Maj-Negative
Number Zone JL Width(in) Height(in) Elevation(ft) ]I Pressure(psf) IL Pressure(psf)
1 Int 63 767 29.9 -32.7
.
._......_--_.................__..... _ —.................-_....-_........_....................._ --................----....--------................__....---.._..._....._..............._...---._.............. ..........._..............................._...................--
2 Int 63 62 7 30.4 -33.1
3 - Int 63 62 7 30.4, -33.1
4 Int 72 80 7 29.6 -32.3
j 5 Int 72 62 7 30.1 -32.8
- —
................_......._....------ ---- - --..._.......--- ----.............
6 Int 35 47 7 32.2 -35.0
I
i
I
a
_ I
{
i
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.