HomeMy WebLinkAboutBuilding Permit Application ALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED ^ I
Date: Permit Number:
--row
- RECEIVED
Building Permit Application
Planning and Development Services ' DEC 0 7 2018
Building and Code Regulation Division ST. Lucie County, Permitting
2300 Virginia Avenue,Fort Pierce FL 34982
Phone: (772)462-1553 Fax: (772)462-1578 Commercial Residential xxxx
PERMIT APPLICATION FOR: Roof
PROPOSED:IMPRQVEIVIENT LOCATION '
Address: 1964 Jaynell St, Ft.Pierce,FL 34945
Legal Description: 13 35 39 W 1/2 OF N 264 FT OF E 1/2 OF SW 1/4 OF NW 1/4 OF SE 1/4-LESS W 25 FT-(0.89 AC)(OR 1020-608:1124-2;3703-56,58)
Property Tax ID#: 2312-423-0002-000-0 Lot No.
Site Plan Name: Block No.
Project Name: Aleda Caldwell Reroof
Setbacks Front Back: Right Side: Left Side:
-7-777771
DETAILED DESCRI.PTION,OF WORK '-
Remove and replace existing roof
n&e.o, ocor etvyr*-4 Sk,ng*S owd v � lr,�a►�, .
1114, P66z ;VA GA IF i'4'...v (-"W c nf4r law" e4j' or,d /"PIA,c 001,94'/'3
CONSTRUCTION INFORMATION
Additional work to be nertormed under this permit—check all appy:
HVAC Gas Tank []Gas Piping _Shutters Q Windows/Doors
FlElectric ❑ Plumbing Sprinklers E Generator R1 Roof 512 Roof pitch
Total Sq. Ft of Construction: 4181.9 S . Ft.of First Floor:
Cost of Construction:$ 28,929.00 Utilities:]Sewer E]Septic Building Height: 15
OWNER/LESSEEc` CONTRACTOR:.
Name Aleda Caldwell Name: Bryon Keith McStoots
Address:1964 Jaynell St. Company: PetersenDean Roofing
City: Ft.Pierce State: FL Address: 1011 Fairfield Drive
Zip Code: 34945 Fax: City: West Palm Beach State:FL
Phone No.772-320-8482 Zip Code: 33407 Fax: 561-881-0699
E-Mail:freewayl964@gmail.com Phone No. 561-881-0660
Fill in fee simple Title Holder on next page(if different E-Mail: kismith@petersendean.com
from the Owner listed above) State or County License: CCC1329081
If value of construction is$2500 or more,a RECORDED Notice of Commencement is required.
S )PPLE.MENTAL_CONS TRUCTION LIEIU LAW IN'I"'
DESIGNER/ENGINEER: _Not Applicable MORTGAGE COMPANY: _NotApplicable
Name: Name:
Address: Address:
City: State: City: State:
Zip: Phone Zip: Phone:
FEE SIMPLE TITLE HOLDER: _Not Applicable BONDING COMPANY: _Not Applicable
Name: Name:
Add ress:ioi+ra(feld Drive Address:
City: City:
Zip: Phone: Zip: Phone:
OWNER/CONTRACTOR AFFIDVIT:Application is hereby made to obtain a permit to do the work and installation as indicated.
I certify that no work or installation has commenced prior to the issuance of a permit.
St.Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules,bylaws or and covenants that may restrict or prohibit such
structure.Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit,I do hereby agree that I will,in all respects,perform the work
in accordance with the approved plans,the Florida Building Codes and St.Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review:room additions,
accessory structures,swimming pools,fences,walls,signs,screen rooms and accessory uses to another non-residential use
WARNING TO OWNER:Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property.A Notice of Commencement must be recorded and posted on the jobsite
before the first inspection. If you intend to obtain financing, consult with lender or an attorney before
commencina work or recording our Notice of Commencement.
6)U&v
Signature of Owner/Lessee/Contractor as Agent for Owner nlrau e o 0 or/License Holder
STATE OF FLO A STATE OF FLORIDA
COUNTY OF r/ n..1 Omch Poifp'I fJ COUNTY OF P9c- 4:3>
The f ng instru nent was qcknowledged efore me The forgojng instrume was acknowledged before me
this day of 20 by this ; day of 41,Q✓ 20/by
U �3> .�/ -41G:s7ve�r-S
Name of person making statement / Name of person ing statement
Personally Known OR Produced Identification ✓ Personally Known OR Produced Identification
Type of Identification Type of Identification
Produced Produced
(S' re of Notary Public-State of orida (Signature of Notary Public-St of Florida)
Commission No. (Seal) Commission No. (Seal)
REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE
COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW
DATE
RECEIVED
DATE
COMPLETED AtARHA Al ImA MURPHY1
Rev.8/2/17
•= MY COMMISSION#GG137493. � = MY COMMISSION#GG 081027
�►�,
EXPIRES August 23,2021 ="s. o°c EXPIRES:April 13,2021
Bonded Thru Notary Public Underwriters
JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT — 'SAINT LUCIE COUNTY
FILE # 4508807 OR BOOK 4210 PAGE 1992, Recorded 12/07/2018 10:05:11 AM
I
,
NOTICE OF COMMENCEMENT
Permit No. Property Tax ID No. 2313-423-0002-000-0
State of Florida,County of St.Lucie
The undersigned hereby gives notice that improvement will be made to certain real property,and in accordance with
Chapter 713,Florida Statutes,the following information is provided in this Notice of Commencement.
Legal Description of property and address if available 13 35 39 W 1/2 OF N 264 FT OF E 1/2 OF SW 1/4
OF NW 1/4 OF SE 1/4-LESS W 25 FT-(0.89 AC) (OR 1020-608: 1124-2; 3703-56, 58)
General description of improvements Remove and replace existing roof
Ownerflessee Neda J Caldwell
Address 1964 Jaynell STFort Pierce,FL 34945 =
Interest in property: 1964 Jaynell STFort Pierce, FL 34945 va o
x
Fee Simple Title holder(if other than owner) o}
cc
Address = v
Contractor PetersenDean Roofing 8 Solar s Phone# 561-881-0660 W — v
Address 1011 Fairfield Drive,West Palm Beach,FL 33407 Fax# 561-881-0699 z w CC L=
CD
Surety Phone# U-CD CD o a
E3
Address Fax# c�¢me
Amount of Bond y I—j=c m cc
Lender Phone#
Address Fax#
Persons within the State ofFlorida designated by Owner upon whom notices or other documents may be served as provided
by Section 713.13(a)7.,Florida Statues:
Name Phone#
Address Fax#
In addition to himself,owner designates of
Phone# Fax#
i
to receive s copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Expiration date of notice of
commencement is one year from the date of recording unless a different date is specified. WARNING TO OWNER:
ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER
PAYMENTS UNDER CH.713.13,F,S.,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON TILE JOB SITE BEFORE THE FIRST INSPECTION,IFYOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF
COMMENCMENT. /I
Owuer/Iassee,or O er's or Lessee's Anthorged OfficerrDirector/Partner/Managed Signature
Owner
Signatory's Title/Office
State o lorlda,County of ocacch
Ac ledged before me this ,day of 20 jr byLWA
w 4eolfrNotary
all no t me who has produced_ Y l /"S /—vierva:j as identification.
g
%W1 Ir
SI atType or print Name of Notary V (tea{)
Title:Notary Public Commission Number �� q
�°
"�: NATASHA ALI CIA MURPHY
`r MY COMMISSION#G0137493,
,o. EXPIRES August 23,2021 I
i
t
RECEIVED
DEC 0 7 2018
sr. Lucie County, Permlltingj Premium Report
��EAG, 10/27/2018
Claim: 27
o ..
LENG kA,
'total Line Lengths: valleys,=7s rt >lashing=S:ft
Midges=81 ft Rake's=,55 rt Step flashing :a ft
mos= 1*43(i Eaves 283A Parapets= 0 ft
SF\
fay
4,
i
i
13 LO da
jN
27 W � E
t
j
5
3
Note:This diagram contains segment lengths(rounded to the nearest whole number)over 5.0 Feet.In some cases,segment labels
have been removed for readability.Plus signs preface some numbers to avoid confusion when rotated(eg.+6 and+9).
MIMM
6i i003-2018 Fa91e Wea 7Kbn.10 les,Li wW Pkt"Iry 1Memadowl Cotµ-AU R6fts R—'v d-Fo;eded by European fW)Ia APOQUM Na 101621993-Care d by tt marc!US.Patent We A On,436;%14S,578;8;170,M; i
6,209,352;8,51S,125;8,625,454,9,115,737;8,670,961;9414,568;8,818,M;8,542,860;9.244,589;9,329,749;95:7.466.0"t Palmy,Pe d'sz9.
PAGE 4
10/3112018 13769_14873 1.jpg(512X384)
i RECEIVED
DEC 0 7 Z018
ST.Lucie County, Permitting
py
FIL Ct
---------------------
37 ,
"E 22'
(1292) '
4 24
9
' 14 9 17 7 4
$PRA
44
40 BAS
(2470)
107 22
3
43 4 ]0 OAA 25
4 18 (550)
22
t
i
a
i
https://www.pasic.org/imageSketches!sketch/13/13769_14873_l.jpg ]!1 '
Florida Building Code Online
Pagel of 2
1V-111,
101
m ¢ �
{,q�, r !
524 �
47
SCIS Home i Log In 1 User Registmuon not Topics j Submit Surcharge Stets®Fads Publlcat FOC SWR
BUS Site Na �y
T�3 p Unks i Search 1
.� Produtt'A
''. trsea:A a c-Pproval.
RECEIVED
Emduct Val menu>product Or Annl:,.,n..
"">Aonl'catio t
_Lt
>Appliention Metall
FL#
Application Type FL10124-R20 DLC O 7 2018
Cade Version Revision
Application Status 2017 ST, Lucie County, Permitting
Approved
Comments
Archived jewo"
L41
Product Manufacturer GAF
R LL (MJ'a U
Address/Phone/Email 1 Campus Drive
Parisppany,NJ 07054
(800)766-3411
mstleh@gaf.com
Authorized Signature Robert Nieminen
lindarelth@trinityerd.com
Technical Representative William Broussard
Address/Phone/Email 1 Campus Drive
Parsippany,NJ 07054
(800)766-3411
Techn icalQuestlonsGAFOgaf.com
Quality Assurance Representative
Address/phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nleminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/20/2018
Validated By
John W.Knezevich,PE
13 Validation Checklist-Hardcopy Received
Certificate of Independence FL10124 R20 COI 2017 01 COI Nieminan tr
Referenced Standard and Year(of Standard) Standard
ASTM D1970 )C�t
ASTM D3161 2015
ASTM D3462 2016
2010 1
ASTM D7158 2011
TAS 107 1495
i
Equivalence of Product Standards
Certified By
t
Sections from the Code
bttp-//W wv.floridabuildin .or / r/ r a
g g P p pp_dtl.aspx.param=wGEVXQwtDquracBeVCbd... 12/14/2017
Florida Building Code Online Page 2 of 2
Product Approval Method Method i Option D
Date Submitted 09/20/2017
Date Validated 09/27/2017
Date Pending FSC Approval 09/28/2017
Date Approved 12/12/2017
Summary of Products
FL# Model,Number or Name Description
10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab,laminated,5-tab and hip/ridge
asphalt shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:No EL10124 8220 II 2017 Q9 FINAL ER CAF Asphalt
Approved for use outside HVHZ:Yes Shinales FL10124-R20.Ddf
Impact Resistant:N/A Verified By:Robert Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other:Refer to ER,Section S. Evaluation Reports
FL10124 R20 AE 2017 09 FINAL ER GAF Asphalt
Shingles FLIt?124-R20.Ddf
Created by Independent Third Party:Yes
.acR dext
Con-ct Us::2601,Witir Stone Road.Tallahassee rL 32322 phone:850-487-10Z4
The Stated Florida is an WEED employer.Coavrinht 2007.20,15[ate of Flarida.::Nlvacv Statement;:AQ=1h11i12 Statement:*Refund Stat>ment
under Florida law,email addresses are public records.It you do not want your a-mall address released In response to a publlc-reeoms request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.It you have arry questions,please Contact 850.487.1395.'Pursuant to
Section 455.275(2),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official Communkatlon with the licensee.However email addresses are public mWrd.If you do net wish to
supply a personal address,please provide the Department with an emoll address which can be made available to the public.To determine It you are a licensee under
Chapter 455,F.S.,please cods hM.
Product Appprr�ovva�l(A�cc'e"pts:
23 Ell
CrwC!Cara_
see
i
i
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=%,GEVXQwtDquracBeVCbd... 12/14/2017
`
FILE COPY
EKTE8IOR RESEARCH&DESIGN,I.I.C.
'
Certificate of Authorization#9503
� & 353CHRISTIAN STREET,UNIT#1u
�� ��m��K '» � y�]���� oxnom�cTos47u
* (203)262-9245
EVALUATION REPORT
GAF Evaluation Report 01506.01.08-1122
1Campus Drive F00224-1120
Parsippany,N] 07O54 Date mfissuance:01^03W2008
(800)766-341% Revision 22:09/20/2017
SCOPE:
This Evaluation Report is issued under mule 61620-3 and the applicable rules and regu|adnha governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building [ode, Residential-Volume. The
products described herein have been evaluated for compliance with the eEdition (2017) Florida Building Code
sections noted herein.
DsScwpnmm: GAF Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2'7'1/R905'2'6'1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.if the
product changes or the referenced Quality Assurance documentation changes. Trinity|EKD requires a complete
'
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT.The Evaluation Report number preceded by the words "Frinityl ERD Evaluated" may be displayed in
advertising literature. \fany portion ofthe Evaluation Report bdisplayed,then it shall bedone inits entirety.
INSPECTION:Upon request,mcopy pfthis entire Evaluation Report shall beprovided omthe user bythe manufacturer ur
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists ofpages 1through 6.
Prepared by:
Robert J,P4,Nlem;nen,p^E. n°*�=�°� �"�^*���" *=�~
mwm�xrg��nmmmusgz6�oum�og�/mu�mm r~--` ^c=o9120/2mom**~,"m^erve..=electronically signed
document.
CERTIMA-rioN OF INDEPENDENCE:
z. TonIv|sxodoes not have, nor does xintend macquire v,will it acquire,ofinancial interest inany company manufacturing v,
distributing products itevaluates.
z TrinityJ ERD is not owned,operated or controlled by any company manufacturing or distributing products It evaluates.
y. Robert wiemmen,p.s.does not have nor will acquire,a financial interest}nany company manufacturing mdistributing products for
which the evaluation reports are being issued.
^. Robert nxemin,m'psdoes not have,nor will acquire,a financial interest in any other entity involved in the approval process of the '
product.
5. This isvbuilding code evaluation. Neither Trinity I ERD nor Robert Nierninen,P.E.are,in any way,the Designer of Record for any
project onwhich this Evaluation Report,v,previous versions thereof,is/was used for permitting v,design guidance unless retained
specifically for that purpose.
.flk4lr('IRS
ROOFING SysTEms EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category. Asphalt Shingles
Compliance Statement: GAF Asphalt Roof Shingles,as produced by GAF,have demonstrated compliance with the
following sections of the 6'h Edition (2017) Florida Building Code and Florida Building Code,Residential Volume
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property, Standard Year
1507.2.4 1507.1.1, Physical Properties ASTM D1970 2015
R905.2.3 J R905.1.1
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,8905.2.6.1 Wind Resistance ASTM D7158 2011
1507.2.7.1,8905.2.6.1 Wind Resistance TAS 107 1995
3. REFERENCES:
gaiint Examination Reference Date
GAF(PDM 1915) Letter of Equivalency Sea]-A-Ridge Impact Resistant IR 01/1312012
PRI(TST 5878) Physical Properties GAF-025-02-01 03/27/2002
PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004
PR)(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005
PRI(TST 5879) Physical Properties GAF-324-02-01 12/01/2011
PRI(TST 5878) Wind Driven Rain GAF-407-0201 01/21/2013
UL(TST 1740) ASTM D3462 93NK6295 11/29/1993
UL(TST 1740) ASTIVI D3462 99NK43835 01/12/2000
UL(TST 1740) TAS 107 94NK9632 03/29/2000
UL(TST 1740) ASTM D3462 OINK0663Z 02/02/2001
UL(TST 1740) ASTM D3161,TAS 107 OINK9226 05/21/2001
UL(TST 1740) ASTM D3161 CINK37122 12/18/2001
UL(TST 1740) ASTM D3462 OINK37122 12/19/2001
UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002
UL(TST 1740) ASTM D3161,TAS 107 02NK30971 09/09/2002
UL(TST 1740) ASTM D3161 03CA5367 03/11/2003
UL(TST 1740) ASTM D3462 03NK26444 10/17/2003
UL(TST 1740) ASTM D3462 04NK13850 06/07/2004
UL(TST 1740) ASTM D3161 04NK13950 06/23/2004
UL(TST 1740) ASTM D3161 04NK30546 03/10/2005
UL(TST 1740) ASTM D3462 04NK22009 05/06/2005
UL(T-ST 1740) ASTM D3161 04NK22009 05/09/2005
UL(TST 1740) ASTM D3462 05NK27924 02/10/2006
UL(TST 1740) ASTM D3161 D5NK27924 02/11/2006
UL(TST 1740) ASTM D3161,D3462 06CA18077 06105/2006
UL(TST 1740) ASTM D3161,D3462 06CA18074 06/16/20OG
UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2005
UL(TST 1740) ASTM D3462 06CA31603 12/01/2006
UL(TST 1740) ASTM D3161,D3462 06CA41095 12127/2006
UL(TST 1740) ASTM D3161 07NK05228 03/13/2007
UL(TST 1740) ASTM D3161 06CA31611 04/04/2007
UL(TST 1740) ASTM D3161 06CA61149 04/09/2007
UL(TST 1740) ASTM D3161,D3462 07CA31742 11/09/2007
UL(TST 1740) ASTM D3161,D7159,D3462 08CA06100 03/13/2008
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-RZ2
Cerlfflmte ofALdhadzotton 119503 EDITION(2017)FBC NON-HVHZ EVALUATION F110124-1170
GAF Asphalt Roof Shingles Revision 22:09120/2017
Page 2 of 6
TRNITYiERD
1
Entitiv Examination Reference Date
UL(TST 1740) ASTM D3161,D3462 07CASS908 04/01/2009
UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009
UL(TST 1740) ASTM D3161,D3462 09CA06956 05/15/2009
UL(TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009
UL(TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009
UL M 1740) ASTM D3161,D7158,D3462 IOCA35554 03/05/2010
UL(TST 1740) ASTM D3161,D7158,D3462 IOCA13686 05/15/2010
UL(TST 1740) ASTM D3462 IOCA07264 05/27/2010
UL(TST 1740) A5TM D3462 IOCA11953 10/29/2010
UL OW 1740) ASTM D3161,D7159,D3462 IONK11951 10/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 IONK12070 11/0412010
UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01130/2010
UL(TST 1740) ASTM D3161,D7158,D3462 IOCAS3934 03131/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/2011
UL(TST 1740) ASTM D3161,D7158,D3462 IICA47919 12/0312011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA49409 12/08/2011
UL(TST 2740) ASTM D3161,D7158,D3462 11CA49725 12/09/2011
UL,LLC.(TST 9628) ASTM D3462 12CA34891 10/12/2012
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 12CAS8151 02/1512013
UL,LLC.(TST 9628) ASTM D3161 12CA38083 02/26/2013
UL,LLC.(TST 9628) ASTM D3161 13CA32332 06/18/2013
UL,LLC.(TST 9628) ASTM D3161 13CA37934 08/02/2023
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4786875675 07/17/2015
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4787434542 05/17/2016
UL,I-I-C.(QUA 9625) Quality Control Inspection Report,R21,Mobile,AL 10/25/2016
UL,U.C.(QUA 9625) Quality Control Inspection Report,R21,Myerstown,PA 10/20/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tuscaloosa,AL 11/11/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Michigan Cty,IN 11/0112016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Shafter,CA 11/17/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Savannah,GA 11/11/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,1121,Minneapolis,MN 10/25/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mt.Vernon,IN 10/25/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Baltimore,MD, 10/21/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tampa,FL 11/1712016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Dallas,TX 11/04/2016
UL,I.I.C.(QUA 9625) Quality Control Inspection Report,R21,Ennis,TX 11/03/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Fontana,CA 1110112016
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shinizies:
4.1.1 Marquis" WeatherMaxO, Royal Sovereign' and Sentinel" are a fiberglass reinforced 3-tab asphalt roof
shingles.
4.1.2 Camelot"; Camelot® 11, Fortitude"", Glenwood"", Grand Canyon", Grand Sequoia', Grand Sequoia" IR,
Grand Sequoia" ArmorShieldTm, Monaco", Sienna", Timberline® American Harvest", Timberline,,
ArmorShield"*11,Timberline'Natural Shadow",-Timberline Hp®,Timberline"Cool Series',Timberline Ultra
HDI and Woodland"are fiberglass reinforced,laminat+'�ed asphalt roof shingles.
4.1.3 Slateline"is a fiberglass reinforced S-tab asphalt roof shingle.
4.2 Hip&Ridge Shingles
4.2.1 Seat-A-Ridge" Ridge Cap Shingles, Seal-A-Ridge" IR Impact-Resistant Ridge Cap Shingles, Seal-A-Ridge"
ArrnorShlelds Ridge Cap Shingles and Timbertex"Premium Ridge Cap Shingles are fiberglass reinforced,hip
and ridge asphalt roof shingles.
Exterior Research and Design,LLC. Evaluation Report 01506.02.08-822
Certificate of Authorization#9503 6"EDITION(2017)FOC NON-HVHZ EVALUATION FU0124-R20
GAF Asphalt Roof Shingles Revision 22:0912012017
Page 3 of 6
4.3 Accessory Starter Strips:
4.3.1 Pro-Start"Eave/Rake Starter Strip Shingles and WeatherBlocker'"Premium Eave/Rake Starter Strip Shingles
are starter strips for asphalt roof shingles.
4.3.2 QuickStartO Peel & Stick Starter Roll is a is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS
modified bitumen starter strip,nominal 9-inch x 33 ft roll,for use with asphalt shingles with exposure of 6-
inch or less.
4.3.3 Starterivlatch"' Starter Strip Shingles are color-coordinated starter strips for use with Grand Canyon®and
Grand SequoiaO series asphalt shingles. StarterMatch— are installed as the second starter for Grand
Canyon's and Grand SequoiaO series installations.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for.any project on which this Evaluation Report,or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
5.4 Wind Classification:
5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for
use in all wind zones up to Vaud=150 mph(V„it=194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 The GAF hip&ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for use in all wind zones up
to V�,Sd=150 mph(V,it=194 mph). Refer to Section 6 for Installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies only to exposure category B or C,as defined in FBC 1609.4.3,.and a
mean roof height of 60 feet or less. Calculations by a qualified design professional are required for
conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval,or be
Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or 8905.2.3.
6.2 Starter Shingles or Starter Strip:
6.2.1 Installation of Pro-Start Eave/Rake Starter Strip Shingles,WeatherBlocker Premium Eave/Rake Starter Strip
Shingles and Quick5tart Peel&Stick Starter Roll shall comply with the GAF current published instructions.
6.3 Asphalt Shingles.
6.3.1 installa€ion of asphalt shingles shall comply with the GAF current published instructions,using minimum four
(4)nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions:
➢ Camelot,Camelot 11,Grand Canyon,Grand Sequoia,Grand Sequoia IR,Grand Sequoia Armor5hleld,
and Woodland require minimum five(5)nails per shingle.
➢ Slateline requires minimum six(6)nails per shingle.
i
6.3.2 Fasteners shall be in accordance with manufacturer's published requirements,but not less than FBC 1507.2.6
or R905.2.5. Staples are not permitted.
6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. Contact the GAF for details.
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R22 f
Certificate OfAuthorlmBon#9503 6r"EDITION(2017)FBC NON44VHZ EVALUATION F1.10124-1120 $
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 4 of 6
LERD
6.4 Nip-&.Ridge Shingles:
6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles,Seal-A-Ridge IR Impact-Resistant Ridge Cap Shingles and
Seal-A-Ridge ArmorSh(eld Ridge Cap Shingles shall comply with the GAF current published instructions with
a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and nominal 0.25-inch diameter
beads of Henkel"Loctite Pl.S30 Roof&Flashing Sealant .
Sealant
pwiants
A25nin) Encfaft crdlatmh#116
iNn:
-�k
Nail
clivo
6.4.2 installation of Timbertex Premium Ridge Cap Shingles shall comply with GAF current published instructions
with a minimum two(2)nails,minimum 3/8-inch head diameter, per shingle and beads of Sonneborn NP1
Gun Grade Polyurethane Sealant or Henkel Pl.Roofing and Flashing Sealant.
tmu ov'I.
'2,5 rim',
�
425nm I
A
fir" ..............-
6.4.3 Fasteners shall be in accordance with GAF published requirements, but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
Exterior Research and Design,U.C. Evaluation Report 01506.01.08-R22
CertUlcate of Authorizatiba#9503 e"EDITION(2017)FSC NON-HVHZ EVALUATION FLI0124-RZD
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 5 of 6
—F\Ll
TIRINTY.'r-l"'
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table I507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to property evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 6I020-3 QA
requirements.
10, QUALITY ASSURANCE ENTITY:
U L LLC–QUA9625;(847)664-3281
END OF EVALUATION REPORT-
yy
Exterior Research and Design,LLC. Evaluation Report 01506.01.09422
Certificate plAutharizattan 99503 6`"EDITION(2017)F13C NON-liVHZ EVALUATION FU0124-420
GAF Asphalt Roof Shingles ReVISIDn 22:09/20/2017
Page 6 of 6
Florida Building Code Online Page I of 2
Bas Nome E,Log to I user it"Istration Het Topics Submit Surcharge Stats&Pacts Publication°r Fac stair i Bets Site Map Links{ Search
+ Y Product Approval
USEW.Public User
e �
product Aoo ov!Ment>ort dtict o Agn icat'on SPAM>ApoNcation t isi>ApPlieatlon Detail
{ $ Fl-# FL15487-R6
` Application Type Revision
Code Version 2017
Application Status Approved
W031M gr 11L Ar '%
Comments L
Archived ❑
F. .t UU,
Product Manufacturer GAF
Address/Phone/Email 1 Campus Drive
Parisppany,N3 07054
(800)766-3411
mstieh@gaf.com
Authorized Signature Robert Nieminen
iindar@nemoetc.com
Technical Representative William Broussard
Address/Phone/Email 1 Campus Drive
Parsippany,N3 07054
(800)766-3411
Tech nica{QuestionsGAF@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Undedayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/24/2019
Validated By Sohn W.Knezevich,PE
8 Validation Checklist-Hardcopy Received
Certificate of Independence FLA 5487 R66 COI 2017 O1 COI Niemtnen.odf
Referenced Standard and Year(of Standard) 51landard leart
ASTM D226(physicals) 2009
ASTM D4533(tear) 2015
Equivalence of Product Standards
'i
Certified By
Sections from the Code
a
htt •//www.floridabuildin .or r/ r a dtl.as x? aram=wGEVX wtD to %2bDhVR 3/26/2018
p• gP P PP_ P P Q 9 P Q x
f
Florida Building Code Online Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 12/1512017
Date Validated 12/18/2017
Date Pending FDC Approval 12/21/2017
Date Approved 02/13/2018
Summa ry of Products
FL# Model,Number or Name Description
15487.1 GAF Synthetic Roof Underlayments Synthetic Roof Underlayments
Limits of use Installation instructions
Approved for use in kiv"Z:No FL15497— R6 11 2017 12 FINAL ER GAF Synthetic
Approved for use outside HVHZ.Yes Undedayments R-15487-116,nd
Impact Resistant:N/A Verified By:Robert Nlemmen PE-59166
Design Pressure.N/A Created by Independent Third Party,Yes
Other.Refer to ER Section 5 for Limits of Use. Evaluation Reports
FLIS487 R6 AF 2017 12 FINAL ER GAP Synthetic
Underlayments 171.15497-116,rid
Created by Independent Third Party:Yes
Beck Next
CrIntask us::maj Blair stone AoU_Tallahassee PI 3239qPhone:a5V-467-i824
The State of Florida is an AMEEO employer.CtayrMlt 2007-201.3 State of Fforlda.::Privacy statement::Amessibility sutter-at:;Refund Statement
under Florida law,email addresses are public records.it you do not want your e-mail address released to response to a pubbe-retards request,do not send
electronic mail to this entity,instead,contact the office by phone or by traditional mall.It you have arty questions,please contact 850.487.13EI5.*Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If
they have am.The emalts provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To detemine If you are a licensee under
Chapter 455,F.S.,please click DEL.
Product Apprwal Aroapts.
http://www.floridabuilding.org/pr/pr_aVp—dti.aspx?Param=WGEVXQWtDqtep%2bDhVRQ... 3/26/2018
CoPWYERR RESEARCH&DESIGN,LLC.
A LE Certificate ofAuthorization#9503
3S3CHRISTIAN STREET,UNIT#l3
�] ���
~� D'8�I��8k � � ^-- '—
OXFORD,CT 06478
^ (2O3)262-924G
EVALUATION REPORT
GAF Evaluation Report 01506.03.12-R6
I Campus Drive FLIS'187-116
Parsippany,NJ 07054 Date of Issuance:04/23/2012
(800)766-3411 Revision 6:12/25/2017
SCOPE!
This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nleminen,
P.E. for use of the product under the Florida Building [ode and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6mEdition (2017) Florida Building Code
sections noted herein.
oscmpnom: GAF Synthetic Rmofopderleymewt
LAacums: Labeling shall be in accordance with the requirements the Accredited Oma|Ky Assurance Agency noted
herein.
ComnmocmCommuxwc : ThisEva|oat|onReportisva|idurtUsuchdmeasthenamedproduct(s)chenges,the referenced
Quality Assurance documentatnnchongos orprovisions ufthe Code that relate tnthe product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen' P.E. if the product
changes orthe referenced Quality Assurance ducumenmtnnchanOes' Trinity\ERDrequires acomplete review cf this
Evaluation Report relative toupdated Code requirements with each Code Cycle.
AowennSmomnTheEvu|uaUonReportnumberp,ecededbytbevwords^Trnity|ERDEva|uated" maybedbplayedin
advertising literature. Vany portion ofthe Evaluation Report\sdisplayed,then it shall hedone inits entirety.
imspsonmmcUpon request,acopy cf this entire Evaluation Report shall beprovided to the user bythe manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists ofpages 1through 6'
Prepared by:
v
Robert J,M.Niem|*en,P.E. n=mcsimite se*appearing was authorized u,Robert
mx�an«smm�mrwusy2e��o*�,DCA xw��o ' w*rni""'nc""cvzv20zzThis does°*"erve=""
y"ctt"m=0v sIgn"oaoc."°m.
CERWICAMOmOFINDEPENDENCE:
z. Trinity\cnD does not have, nu, does it intend to acquire or will it acquire, a financial interest in any company
manufacturing vrdistributing products itevaluates.
Z. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
5. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing
products for which the evaluation reports are being issued.
^. Robert Nieminen,p.E.does not have, nor will acquire,ufinancial interest inany other entity involved inthe approval
process cfthe product.
s. This is a building code evaluation. Neither Tiinitv|ERD nor Robert Nieminem, P.E. are, in anyway the Designer of
Record for any project on which this Evaluation Report, orprevious versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: GAF Synthetic Roof Underlayments,as produced by GAF,have demonstrated compliance
with the following sections of the e Edition(2017)Florida Building Code through testing In accordance with the
applicable sections of the following Standards. Compliance is subject to the Installation Requirements and
Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Prope Standard Year
1507.1.1,T1507.1.1 Unrolling,Breaking Strength, ASTM D226 2009
Pliability
I507.1.1 Tear Strength ASTM D4533 2015
3. REFERENCES:
gatitt Examination Reference Date
ERD CW 6049) Physical Properties R3360.02.07-2-RI 03/13/2007
ERD(TST 6049) Physical Properties 612110.12.08 12/02/2008
PRI(TST 5878) Physical properties BRY-003-02-01 03/19/2002
PRI(TST 5879) Physical properties GAF-224-02-01 07/27/2009
PRI(TST 5878) Physical properties GAF-349-02-01 07/03/2012
PRI(TST 5878) FBC 1507.1.1(Exception) GAF-818-02-01 12105/2017
ITS(TST 1509) Physical properties 100259583COQ-0I0A 01/11/2011
Miami-Dade(CER 1592) HVHZ compliance 16-1213.04 11/16/2017
Miami-Dade(CER 1592) HVHZ compliance 16-1216.02 02102/2017
ICC-ES(EVL2396) IBC/IRC compliance ESR-2053 07/01/2017
ICC-ES(EVL2396) IBC/IRC compliance ESR-2808 07/01/2017
[CC-ES(EVL2396) IBC/lRC compliance ESR-3286 02/01/2017
UL,LLC(QUA 9625) Quality Control 810689,Charleston,SC 06116/2017
UL,LLC(QUA 9625) Quality Control R10689;North Bay,ON 04/05/2017
UL,LLC(QUA 9625) Quality Control R10689;Fontana,CA 07/07/2017
UL,LLC(QUA 9625) Quality Control R10689;McGregor,TX 05124/2016
UL,LLC(QUA 9625) Quality Control R10689,Pryor,OK 06/20/2017
UL,LLC(QUA 9625) Quality Control R10689;Mission,BC 06/27/2017
4. PRODUCT DESCRIPTION:
4.1 Deck-Armor*"' Premium Breathable Roof Deck Protection is a non-woven, spun-bonded polypropylene
laminated polyethylene scrim sheet roof underlayment, available in 48-inch or 54-inch roll widths;meets
FBC 1507.1.1(Exception).
4.2 RoofPrd'SBS-Modified All-Purpose Underlayment is a fiberglass-reinforced,SBS modified bitumen roof
underlayment;meets AC165.
4.3 Shingle-Mate" Roof Deck Protection is a fiberglass reinforced, asphaltic roof underlayment; meets FBC
1507.1.1(Exception).
4.4 StormS06Anchor Sheet is a polypropylene woven fabric which serves as an anchor sheet in two-ply
roof underlayment systems;meets FBC 1507.1.1(Exception).
4.5 TigerPaw"" Roof Deck Protection is a non-woven, polypropylene reinforced, polymer coated roof
underlayment;meets FBC 1507.1.1(Exception).
Exterior Research and Design,LLC. Evaluation Report 015015.03.12lit6
Certftate of Authorization#9503 15PEDITION(2017)FBC NON-HVHZ EVALUATION FLIS487-R6
GAP Synthetic Roof Underlayments Revision 6:12/75/2027
Page 2 of 6
= Tw^^" `m n ^ �—~ D
5' UMnnnomS:
5.1 This ba.building node evaluation. Neither Trinity|ERD nor Robert mi6minen, P.E. are, in any way, the
Peyigner.cf Record for any project unwhich this Evaluation Report, n,previous versions thcrcof, us/w^^
used for permitting o,design guidance unless retained specifically for that purpose.
5,2 This Evaluation Report isv,tfor use inFBCHYMZjurisdictions.
5.3 Re Classification is not part of this Evaluation nepnrt; refer mmcurrent Approved Roofing Materials
Directory ortest report from accredited testing-agency for fire ratings ofthis product.
SA GAF Synthetic mmcf un6wrlwxmema may he used with any prepared roof cover where the product.is
specifically refepenruci within Facappnma| documents. Ifnot listed, a request may be made uothe
Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the
prepared roof covering.
5.s Allowable Roof Covers:
TA BLE1. ROOF COVER OPTIONS
Asphalt Foam-On Wood State or
Underlayment Shingles Nail-On Tile Tile Metal Shakes& Simulated
Shingles Slate
Deck-Armor—Premium
Corft Mfg
Breathable Roof Deck Yes N ontact Mfg Contact Mfg ct
Protection
RoofPro-SBS-Modified
AJI-Purpose es —Yes.
Underlayment
Shingle-Mate"Roof
Deck Protection
Tiger Paw�Roof Deck
ct
J.
Protection
5.6 Exposure Limitations.
Deck-Armor" Premium Breathable Roof Deck Protection; Ronfpnf° SBS-Modified /4|'Pwrpcoe
Undedayment, Shing|c'K8auw° Roof Deck Protection;Stormsafe� Anchor Sheet; Tiger powy" Roof mm±
Protection shall not bcleft exposed for longer than 3O-dayoafter installation.
6. ImsTAuuAT/om/
6.1 ao* Synthetic Roof mndeMammeutsshaU be installed in accordance with GAF published installation
instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly
mmremove any dust and debris prior toapplication.
63 Deck Armor",Pirernium Breathable Roof Deck Protection:.,
6.3.1 Shall be installed in =�Iiance�Zh the requirements for ASTM D226,Type I or 11 underlayment in FBC
Table 1507.1.1 for the type of prepared roof covering to be installed,taking into account the wider sheet-
width fnrdvub|e|ayerapphcatioos
6.3.2 ramenes shall be 1-inch diameter plastic-capped corrosion resistant nails or 1-inch diameter plastic-
capped,corrosion resistant staples.
Exterior Research and Design,LLC. Evaluation Report 01506.03.12-R6
Certificate afAumorizatlan^9503 15'm EDITION(201qFOC NON-HVHZ EVALUATION FLIS487-R6
GAF Synthetic Roof uou=lavmwots Revision s'12/15/ou7
Page sof 6
l
.TP1 ERD
6.3.3 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of Liberty''SBS Self-
Adhering Base/Ply Sheet;StormiSuard®Film Surfaced Leak Barrier,UnderRoof`"2 Polyester-Surfaced Leak
Barrier;UnderRoofl HT High Temperature Leak Barrier;WeatherWatch®Mineral Surfaced Leak Barrier or
WeatherWatch®XT Mat Surfaced Leak Barrier at vulnerable leak areas,including but not limited to eaves,
valleys,rakes,skylights and dormers. At eaves and valleys,install the leak barrier prior to installation of
the underlayment. Along the rake,install the underlayment,leaving 6 to 8-inch of the deck exposed,and
then install the leak barrier over the underlayment and exposed decking. At other areas, install the leak
barrier over the underlayment. Refer to FL10626.
6.3.4 Non-Tile Roof.installations:
Single Laver Roof Slope>4:12:
Starting at the eave,fasten the eave edge and 6-inch wide end-laps 6-inch o.c.Fasten in the field of the roll
12-inch o.c.in two,equally spaced,staggered center rows.
Continue upslope in a similar manner, maintaining minimum 3-inch side-laps and minimum 6-inch end-
laps. Fasten 6-inch o.c.in the laps and 12-inch o.c.in two,equally spaced,staggered center rows in the
field. Ensure all end laps are staggered at least 3-feet apart.
Double Laver:2:12<Roof Slope<.4:12:
if leak barrier (6.3.3) is not used, install a half-width sheet at the eave prior to subsequent courses.
Starting at the eave,fasten the eave edge and 6-inch wide end-laps 6-inch o.c.Fasten in the field of the roil
12-inch o.c.in two,equally spaced,staggered center rows.
Continue upslope in a similar manner,with minimum 25.5-inch side-laps for 48-inch wide rolls(resulting in
maximum 22.5-inch exposure) or minimum 28.5-inch side-laps for 54-inch wide rolls (resulting in
maximum 25.5-inch exposure) and minimum 6-inch end-laps. Fasten 6-inch o.c.along the low edge and
end laps and 12-inch o.c.in two,equally spaced,staggered center rows in the field. Ensure all end laps are
staggered at least 3-feet apart.
6 4;. Tiger Paw""ltaof Deck Prntetlon 3 .; w .
6.4.1 Shall be installed in compliance with the requirements for ASTM D226,Type I or li underlayment in FBC
Table 1507.1.1 for the type of prepared roof covering to be installed,taking into account the wider sheet-
width for double-layer applications.
6.4.2 Fasteners shall be 1-inch diameter plastic-capped corrosion resistant nails or 1-inch diameter plastic-
capped,corrosion resistant staples.
6.4.3 Optional, or if required by the Authority Having Jurisdiction: install a leak barrier of Liberty— SBS Self-
Adhering Base/Ply Sheet;StormGuardm Film Surfaced Leak Barrier;UnderRoof``2 Polyester-Surfaced Leak
Barrier;UnderRoof�°"HT High Temperature Leak Barrier;WeatherWatch®Mineral Surfaced Leak Barrier or
WeatherWatch®XT Mat Surfaced Leak Barrier at vulnerable leak areas,including but not limited to eaves,
valleys, rakes,skylights and dormers. At eaves and valleys,install the leak barrier prior to installation of
the underlayment. Along the rake,install the underlayment,leaving 6 to 8-inch of the deck exposed,and
then install the leak barrier over the underlayment and exposed decking. At other areas,install the leak
barrier over the underlayment. Refer to FL10626.
6.4.4 Non Tile Roof installations:
Single Laver.Roof Slope>4:12:
Starting at the eave,fasten the eave edge and 6-inch wide end-laps 6-inch o.c.Fasten in the field of the roll
12-inch o.c.in two,equally spaced,staggered center rows.
Continue upslope in a similar manner, maintaining minimum 3-inch side-laps and minimum 6-inch end-
laps. Fasten 6-inch o.c. in the laps and 12-inch o.c.in two,equally spaced,staggered center rows in the
field. Ensure all end laps are staggered at least 3-feet apart.
{
Exterior Research and Design,I.I.C. Evaluation Report 01506.03.12-86
CertificoteofAuthorization#9503 6'"EDITION(2017)FBC NON-HVH2 EVALUATION F1.15487-116
GAF Synthetic Roof Underlayments Revision 6:12/15/2017
Page 4 of 6 1
i
ERD
Double Laver:2:12<Roof Slope c 4:12:
If leak barrier.(6.4.3) is not used, install a half-width sheet at the eave prior to subsequent courses.
Starting at the eave,fasten the eave edge and 6-inch wide end-laps 6-inch o.c.Fasten in the field of the roll
12-inch o.c.in two,equally spaced,staggered center rows.
Continue upslope in a similar manner,with minimum 25.5-inch side-laps(resulting in maximum 22.5-inch
exposure)and minimum 64nch end-laps. Fasten 6-inch o.c.along the low edge and end laps and 12-inch
o.c.in two,equally spaced,staggered center rows in the field. Ensure all end laps are staggered at least 3-
feet apart.
6 5 - StomR5afe""-Anchoi�6heet �,
6.5.1 StormSaf0l Anchor Sheet is limited to use as a mechanically attached base layer in 2-01y underlayment
systems.
6.5.2 Fasteners shall be 1-inch diameter plastic-or steel-capped corrosion resistant nails; corrosion-resistant
nails&1-5/8-inch tin-caps;or Drill-Tec screws and plates.
6.5.3 Non-Tile Roof installations:
Starting at the eave,fasten the eave edge and 6-inch wide end-laps 6-inch o.c.Fasten in the field of the roll
12-inch o.c.in two,equally spaced,staggered center rows.
Continue upslope in a similar manner, maintaining minimum 3-inch side-laps and minimum 6-inch end-
laps. Fasten 6-inch o.c. in the laps and 12-inch o.c.in two,equally spaced,staggered center rows in the
field. Ensure all end laps are staggered at least 3-feet apart.
One the same day, install Liberty'SBS Self-Adhering Base/Ply;StormGuarW® Film Surfaced Leak Barrier;
UnderRoof°- HT High Temperature Leak Barrier; WeatherWatch® Mineral Surfaced Leak Barrier or
WeatherWatchO XT Mat Surfaced Leak Barrier over the StormSafe"-Anchor Sheet. Refer to FL10626.
6:6 RoofPi6 SBS-Modified All-Purpose'Underlayment'and Shirr!e M ateO Roof Deck Protection
6.6.1 Shall be installed in compliance with the requirements for-ASTM D226,Type I or 11 underlayment in FBC
Table 1507.1.1 for the type of prepared roof covering to be installed. No hammer tacks or staples are
permitted.
6.6.2 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of UbertyT" SBS Self-
Adhering Base/Ply Sheet;StormGuardO Film Surfaced Leak Barrier,UnderRoof' HT High Temperature Leak
Barrier;WeatherWatchO Mineral Surfaced Leak Barrier or WeatherWatch'XT Mat Surfaced Leak Barrier at
vulnerable leak areas,including but not limited to eaves,valleys,rakes,skylights and dormers. At eaves
and valleys, install the leak barrier prior to installation of the underlayment. Along the rake, install the
underlayment, leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the
underlayment and exposed decking. At other areas,install the leak barrier over the underlayment. Refer
to FL10626.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
'i
Exterior Research and Design,LLC. Evaluation Report 01506.03.12-R6
Certificate of Authorization X9503 6t"EDITION(2017)FSC NON4HVH2 EVALUATION FUS"7-116
GAF Synthetic Roof Underlayments Revision 6:12/15/2017
Page 5 of 6
s
R-jj !ERD
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C.61620-3 CA requirements.
The following plants have qualified products under their respective physical properties specifications.
ilaiit S`oecification:__ ProduiMsj
North Bay,Ontario FBC 1507.1.1(Exception) Deck-Armor'"Premium Breathable Roof Deck Protection,StormSafe"
Anchor Sheet
Fontana,CA AC165 RoofProTM SBS-Modified All-Purpose Underiayment
Pryor,OK FBC 1507.2.1(Exception) Shingle-Mate*Roof Deck Protection
McGregor,TX FBC 1507.1.1(Exception) Shingle-Mateo Roof Deck Protection
Mission,BC FBC 1507.1.1(Exce(Exception) Tiger PawTM Roofi Deck Protection
Charleston,SC FBC 1547.1.1(Exception) Tiger PawTM Roof Deck Protection
9. QUALITY ASSURANCE ENTITY:
UL,LLC.—QUA9625;(847)664-3281
•END OF EVALUATION REPORT-
'3
s
1
t
i
I
Exterior Research and Design,LLC. Evaluation Report 01506.0312-R6
CeWflcote ojAutharization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FLLW7-R6
GAF Synthetic Roof Underiayments Revision 6:22/2Sf 2017
Page 6 of 6