Loading...
HomeMy WebLinkAboutBuilding Permit Application ALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED ^ I Date: Permit Number: --row - RECEIVED Building Permit Application Planning and Development Services ' DEC 0 7 2018 Building and Code Regulation Division ST. Lucie County, Permitting 2300 Virginia Avenue,Fort Pierce FL 34982 Phone: (772)462-1553 Fax: (772)462-1578 Commercial Residential xxxx PERMIT APPLICATION FOR: Roof PROPOSED:IMPRQVEIVIENT LOCATION ' Address: 1964 Jaynell St, Ft.Pierce,FL 34945 Legal Description: 13 35 39 W 1/2 OF N 264 FT OF E 1/2 OF SW 1/4 OF NW 1/4 OF SE 1/4-LESS W 25 FT-(0.89 AC)(OR 1020-608:1124-2;3703-56,58) Property Tax ID#: 2312-423-0002-000-0 Lot No. Site Plan Name: Block No. Project Name: Aleda Caldwell Reroof Setbacks Front Back: Right Side: Left Side: -7-777771 DETAILED DESCRI.PTION,OF WORK '- Remove and replace existing roof n&e.o, ocor etvyr*-4 Sk,ng*S owd v � lr,�a►�, . 1114, P66z ;VA GA IF i'4'...v (-"W c nf4r law" e4j' or,d /"PIA,c 001,94'/'3 CONSTRUCTION INFORMATION Additional work to be nertormed under this permit—check all appy: HVAC Gas Tank []Gas Piping _Shutters Q Windows/Doors FlElectric ❑ Plumbing Sprinklers E Generator R1 Roof 512 Roof pitch Total Sq. Ft of Construction: 4181.9 S . Ft.of First Floor: Cost of Construction:$ 28,929.00 Utilities:]Sewer E]Septic Building Height: 15 OWNER/LESSEEc` CONTRACTOR:. Name Aleda Caldwell Name: Bryon Keith McStoots Address:1964 Jaynell St. Company: PetersenDean Roofing City: Ft.Pierce State: FL Address: 1011 Fairfield Drive Zip Code: 34945 Fax: City: West Palm Beach State:FL Phone No.772-320-8482 Zip Code: 33407 Fax: 561-881-0699 E-Mail:freewayl964@gmail.com Phone No. 561-881-0660 Fill in fee simple Title Holder on next page(if different E-Mail: kismith@petersendean.com from the Owner listed above) State or County License: CCC1329081 If value of construction is$2500 or more,a RECORDED Notice of Commencement is required. S )PPLE.MENTAL_CONS TRUCTION LIEIU LAW IN'I"' DESIGNER/ENGINEER: _Not Applicable MORTGAGE COMPANY: _NotApplicable Name: Name: Address: Address: City: State: City: State: Zip: Phone Zip: Phone: FEE SIMPLE TITLE HOLDER: _Not Applicable BONDING COMPANY: _Not Applicable Name: Name: Add ress:ioi+ra(feld Drive Address: City: City: Zip: Phone: Zip: Phone: OWNER/CONTRACTOR AFFIDVIT:Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St.Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules,bylaws or and covenants that may restrict or prohibit such structure.Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit,I do hereby agree that I will,in all respects,perform the work in accordance with the approved plans,the Florida Building Codes and St.Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review:room additions, accessory structures,swimming pools,fences,walls,signs,screen rooms and accessory uses to another non-residential use WARNING TO OWNER:Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property.A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before commencina work or recording our Notice of Commencement. 6)U&v Signature of Owner/Lessee/Contractor as Agent for Owner nlrau e o 0 or/License Holder STATE OF FLO A STATE OF FLORIDA COUNTY OF r/ n..1 Omch Poifp'I fJ COUNTY OF P9c- 4:3> The f ng instru nent was qcknowledged efore me The forgojng instrume was acknowledged before me this day of 20 by this ; day of 41,Q✓ 20/by U �3> .�/ -41G:s7ve�r-S Name of person making statement / Name of person ing statement Personally Known OR Produced Identification ✓ Personally Known OR Produced Identification Type of Identification Type of Identification Produced Produced (S' re of Notary Public-State of orida (Signature of Notary Public-St of Florida) Commission No. (Seal) Commission No. (Seal) REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED AtARHA Al ImA MURPHY1 Rev.8/2/17 •= MY COMMISSION#GG137493. � = MY COMMISSION#GG 081027 �►�, EXPIRES August 23,2021 ="s. o°c EXPIRES:April 13,2021 Bonded Thru Notary Public Underwriters JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT — 'SAINT LUCIE COUNTY FILE # 4508807 OR BOOK 4210 PAGE 1992, Recorded 12/07/2018 10:05:11 AM I , NOTICE OF COMMENCEMENT Permit No. Property Tax ID No. 2313-423-0002-000-0 State of Florida,County of St.Lucie The undersigned hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,the following information is provided in this Notice of Commencement. Legal Description of property and address if available 13 35 39 W 1/2 OF N 264 FT OF E 1/2 OF SW 1/4 OF NW 1/4 OF SE 1/4-LESS W 25 FT-(0.89 AC) (OR 1020-608: 1124-2; 3703-56, 58) General description of improvements Remove and replace existing roof Ownerflessee Neda J Caldwell Address 1964 Jaynell STFort Pierce,FL 34945 = Interest in property: 1964 Jaynell STFort Pierce, FL 34945 va o x Fee Simple Title holder(if other than owner) o} cc Address = v Contractor PetersenDean Roofing 8 Solar s Phone# 561-881-0660 W — v Address 1011 Fairfield Drive,West Palm Beach,FL 33407 Fax# 561-881-0699 z w CC L= CD Surety Phone# U-CD CD o a E3 Address Fax# c�¢me Amount of Bond y I—j=c m cc Lender Phone# Address Fax# Persons within the State ofFlorida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(a)7.,Florida Statues: Name Phone# Address Fax# In addition to himself,owner designates of Phone# Fax# i to receive s copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Expiration date of notice of commencement is one year from the date of recording unless a different date is specified. WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CH.713.13,F,S.,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON TILE JOB SITE BEFORE THE FIRST INSPECTION,IFYOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCMENT. /I Owuer/Iassee,or O er's or Lessee's Anthorged OfficerrDirector/Partner/Managed Signature Owner Signatory's Title/Office State o lorlda,County of ocacch Ac ledged before me this ,day of 20 jr byLWA w 4eolfrNotary all no t me who has produced_ Y l /"S /—vierva:j as identification. g %W1 Ir SI atType or print Name of Notary V (tea{) Title:Notary Public Commission Number �� q �° "�: NATASHA ALI CIA MURPHY `r MY COMMISSION#G0137493, ,o. EXPIRES August 23,2021 I i t RECEIVED DEC 0 7 2018 sr. Lucie County, Permlltingj Premium Report ��EAG, 10/27/2018 Claim: 27 o .. LENG kA, 'total Line Lengths: valleys,=7s rt >lashing=S:ft Midges=81 ft Rake's=,55 rt Step flashing :a ft mos= 1*43(i Eaves 283A Parapets= 0 ft SF\ fay 4, i i 13 LO da jN 27 W � E t j 5 3 Note:This diagram contains segment lengths(rounded to the nearest whole number)over 5.0 Feet.In some cases,segment labels have been removed for readability.Plus signs preface some numbers to avoid confusion when rotated(eg.+6 and+9). MIMM 6i i003-2018 Fa91e Wea 7Kbn.10 les,Li wW Pkt"Iry 1Memadowl Cotµ-AU R6fts R—'v d-Fo;eded by European fW)Ia APOQUM Na 101621993-Care d by tt marc!US.Patent We A On,436;%14S,578;8;170,M; i 6,209,352;8,51S,125;8,625,454,9,115,737;8,670,961;9414,568;8,818,M;8,542,860;9.244,589;9,329,749;95:7.466.0"t Palmy,Pe d'sz9. PAGE 4 10/3112018 13769_14873 1.jpg(512X384) i RECEIVED DEC 0 7 Z018 ST.Lucie County, Permitting py FIL Ct --------------------- 37 , "E 22' (1292) ' 4 24 9 ' 14 9 17 7 4 $PRA 44 40 BAS (2470) 107 22 3 43 4 ]0 OAA 25 4 18 (550) 22 t i a i https://www.pasic.org/imageSketches!sketch/13/13769_14873_l.jpg ]!1 ' Florida Building Code Online Pagel of 2 1V-111, 101 m ¢ � {,q�, r ! 524 � 47 SCIS Home i Log In 1 User Registmuon not Topics j Submit Surcharge Stets®Fads Publlcat FOC SWR BUS Site Na �y T�3 p Unks i Search 1 .� Produtt'A ''. trsea:A a c-Pproval. RECEIVED Emduct Val menu>product Or Annl:,.,n.. "">Aonl'catio t _Lt >Appliention Metall FL# Application Type FL10124-R20 DLC O 7 2018 Cade Version Revision Application Status 2017 ST, Lucie County, Permitting Approved Comments Archived jewo" L41 Product Manufacturer GAF R LL (MJ'a U Address/Phone/Email 1 Campus Drive Parisppany,NJ 07054 (800)766-3411 mstleh@gaf.com Authorized Signature Robert Nieminen lindarelth@trinityerd.com Technical Representative William Broussard Address/Phone/Email 1 Campus Drive Parsippany,NJ 07054 (800)766-3411 Techn icalQuestlonsGAFOgaf.com Quality Assurance Representative Address/phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nleminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/20/2018 Validated By John W.Knezevich,PE 13 Validation Checklist-Hardcopy Received Certificate of Independence FL10124 R20 COI 2017 01 COI Nieminan tr Referenced Standard and Year(of Standard) Standard ASTM D1970 )C�t ASTM D3161 2015 ASTM D3462 2016 2010 1 ASTM D7158 2011 TAS 107 1495 i Equivalence of Product Standards Certified By t Sections from the Code bttp-//W wv.floridabuildin .or / r/ r a g g P p pp_dtl.aspx.param=wGEVXQwtDquracBeVCbd... 12/14/2017 Florida Building Code Online Page 2 of 2 Product Approval Method Method i Option D Date Submitted 09/20/2017 Date Validated 09/27/2017 Date Pending FSC Approval 09/28/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab,laminated,5-tab and hip/ridge asphalt shingles Limits of Use Installation Instructions Approved for use in HVHZ:No EL10124 8220 II 2017 Q9 FINAL ER CAF Asphalt Approved for use outside HVHZ:Yes Shinales FL10124-R20.Ddf Impact Resistant:N/A Verified By:Robert Nieminen PE-59166 Design Pressure:N/A Created by Independent Third Party:Yes Other:Refer to ER,Section S. Evaluation Reports FL10124 R20 AE 2017 09 FINAL ER GAF Asphalt Shingles FLIt?124-R20.Ddf Created by Independent Third Party:Yes .acR dext Con-ct Us::2601,Witir Stone Road.Tallahassee rL 32322 phone:850-487-10Z4 The Stated Florida is an WEED employer.Coavrinht 2007.20,15[ate of Flarida.::Nlvacv Statement;:AQ=1h11i12 Statement:*Refund Stat>ment under Florida law,email addresses are public records.It you do not want your a-mall address released In response to a publlc-reeoms request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.It you have arry questions,please Contact 850.487.1395.'Pursuant to Section 455.275(2),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official Communkatlon with the licensee.However email addresses are public mWrd.If you do net wish to supply a personal address,please provide the Department with an emoll address which can be made available to the public.To determine It you are a licensee under Chapter 455,F.S.,please cods hM. Product Appprr�ovva�l(A�cc'e"pts: 23 Ell CrwC!Cara_ see i i http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=%,GEVXQwtDquracBeVCbd... 12/14/2017 ` FILE COPY EKTE8IOR RESEARCH&DESIGN,I.I.C. ' Certificate of Authorization#9503 � & 353CHRISTIAN STREET,UNIT#1u �� ��m��K '» � y�]���� oxnom�cTos47u * (203)262-9245 EVALUATION REPORT GAF Evaluation Report 01506.01.08-1122 1Campus Drive F00224-1120 Parsippany,N] 07O54 Date mfissuance:01^03W2008 (800)766-341% Revision 22:09/20/2017 SCOPE: This Evaluation Report is issued under mule 61620-3 and the applicable rules and regu|adnha governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building [ode, Residential-Volume. The products described herein have been evaluated for compliance with the eEdition (2017) Florida Building Code sections noted herein. DsScwpnmm: GAF Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2'7'1/R905'2'6'1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.if the product changes or the referenced Quality Assurance documentation changes. Trinity|EKD requires a complete ' review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT.The Evaluation Report number preceded by the words "Frinityl ERD Evaluated" may be displayed in advertising literature. \fany portion ofthe Evaluation Report bdisplayed,then it shall bedone inits entirety. INSPECTION:Upon request,mcopy pfthis entire Evaluation Report shall beprovided omthe user bythe manufacturer ur its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists ofpages 1through 6. Prepared by: Robert J,P4,Nlem;nen,p^E. n°*�=�°� �"�^*���" *=�~ mwm�xrg��nmmmusgz6�oum�og�/mu�mm r~--` ^c=o9120/2mom**~,"m^erve..=electronically signed document. CERTIMA-rioN OF INDEPENDENCE: z. TonIv|sxodoes not have, nor does xintend macquire v,will it acquire,ofinancial interest inany company manufacturing v, distributing products itevaluates. z TrinityJ ERD is not owned,operated or controlled by any company manufacturing or distributing products It evaluates. y. Robert wiemmen,p.s.does not have nor will acquire,a financial interest}nany company manufacturing mdistributing products for which the evaluation reports are being issued. ^. Robert nxemin,m'psdoes not have,nor will acquire,a financial interest in any other entity involved in the approval process of the ' product. 5. This isvbuilding code evaluation. Neither Trinity I ERD nor Robert Nierninen,P.E.are,in any way,the Designer of Record for any project onwhich this Evaluation Report,v,previous versions thereof,is/was used for permitting v,design guidance unless retained specifically for that purpose. .flk4lr('IRS ROOFING SysTEms EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category. Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles,as produced by GAF,have demonstrated compliance with the following sections of the 6'h Edition (2017) Florida Building Code and Florida Building Code,Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property, Standard Year 1507.2.4 1507.1.1, Physical Properties ASTM D1970 2015 R905.2.3 J R905.1.1 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,8905.2.6.1 Wind Resistance ASTM D7158 2011 1507.2.7.1,8905.2.6.1 Wind Resistance TAS 107 1995 3. REFERENCES: gaiint Examination Reference Date GAF(PDM 1915) Letter of Equivalency Sea]-A-Ridge Impact Resistant IR 01/1312012 PRI(TST 5878) Physical Properties GAF-025-02-01 03/27/2002 PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004 PR)(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005 PRI(TST 5879) Physical Properties GAF-324-02-01 12/01/2011 PRI(TST 5878) Wind Driven Rain GAF-407-0201 01/21/2013 UL(TST 1740) ASTM D3462 93NK6295 11/29/1993 UL(TST 1740) ASTIVI D3462 99NK43835 01/12/2000 UL(TST 1740) TAS 107 94NK9632 03/29/2000 UL(TST 1740) ASTM D3462 OINK0663Z 02/02/2001 UL(TST 1740) ASTM D3161,TAS 107 OINK9226 05/21/2001 UL(TST 1740) ASTM D3161 CINK37122 12/18/2001 UL(TST 1740) ASTM D3462 OINK37122 12/19/2001 UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002 UL(TST 1740) ASTM D3161,TAS 107 02NK30971 09/09/2002 UL(TST 1740) ASTM D3161 03CA5367 03/11/2003 UL(TST 1740) ASTM D3462 03NK26444 10/17/2003 UL(TST 1740) ASTM D3462 04NK13850 06/07/2004 UL(TST 1740) ASTM D3161 04NK13950 06/23/2004 UL(TST 1740) ASTM D3161 04NK30546 03/10/2005 UL(TST 1740) ASTM D3462 04NK22009 05/06/2005 UL(T-ST 1740) ASTM D3161 04NK22009 05/09/2005 UL(TST 1740) ASTM D3462 05NK27924 02/10/2006 UL(TST 1740) ASTM D3161 D5NK27924 02/11/2006 UL(TST 1740) ASTM D3161,D3462 06CA18077 06105/2006 UL(TST 1740) ASTM D3161,D3462 06CA18074 06/16/20OG UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2005 UL(TST 1740) ASTM D3462 06CA31603 12/01/2006 UL(TST 1740) ASTM D3161,D3462 06CA41095 12127/2006 UL(TST 1740) ASTM D3161 07NK05228 03/13/2007 UL(TST 1740) ASTM D3161 06CA31611 04/04/2007 UL(TST 1740) ASTM D3161 06CA61149 04/09/2007 UL(TST 1740) ASTM D3161,D3462 07CA31742 11/09/2007 UL(TST 1740) ASTM D3161,D7159,D3462 08CA06100 03/13/2008 Exterior Research and Design,LLC. Evaluation Report 01506.01.08-RZ2 Cerlfflmte ofALdhadzotton 119503 EDITION(2017)FBC NON-HVHZ EVALUATION F110124-1170 GAF Asphalt Roof Shingles Revision 22:09120/2017 Page 2 of 6 TRNITYiERD 1 Entitiv Examination Reference Date UL(TST 1740) ASTM D3161,D3462 07CASS908 04/01/2009 UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009 UL(TST 1740) ASTM D3161,D3462 09CA06956 05/15/2009 UL(TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009 UL(TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009 UL M 1740) ASTM D3161,D7158,D3462 IOCA35554 03/05/2010 UL(TST 1740) ASTM D3161,D7158,D3462 IOCA13686 05/15/2010 UL(TST 1740) ASTM D3462 IOCA07264 05/27/2010 UL(TST 1740) A5TM D3462 IOCA11953 10/29/2010 UL OW 1740) ASTM D3161,D7159,D3462 IONK11951 10/30/2010 UL(TST 1740) ASTM D3161,D7158,D3462 IONK12070 11/0412010 UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01130/2010 UL(TST 1740) ASTM D3161,D7158,D3462 IOCAS3934 03131/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/2011 UL(TST 1740) ASTM D3161,D7158,D3462 IICA47919 12/0312011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA49409 12/08/2011 UL(TST 2740) ASTM D3161,D7158,D3462 11CA49725 12/09/2011 UL,LLC.(TST 9628) ASTM D3462 12CA34891 10/12/2012 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 12CAS8151 02/1512013 UL,LLC.(TST 9628) ASTM D3161 12CA38083 02/26/2013 UL,LLC.(TST 9628) ASTM D3161 13CA32332 06/18/2013 UL,LLC.(TST 9628) ASTM D3161 13CA37934 08/02/2023 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4786875675 07/17/2015 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4787434542 05/17/2016 UL,I-I-C.(QUA 9625) Quality Control Inspection Report,R21,Mobile,AL 10/25/2016 UL,U.C.(QUA 9625) Quality Control Inspection Report,R21,Myerstown,PA 10/20/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tuscaloosa,AL 11/11/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Michigan Cty,IN 11/0112016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Shafter,CA 11/17/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Savannah,GA 11/11/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,1121,Minneapolis,MN 10/25/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mt.Vernon,IN 10/25/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Baltimore,MD, 10/21/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tampa,FL 11/1712016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Dallas,TX 11/04/2016 UL,I.I.C.(QUA 9625) Quality Control Inspection Report,R21,Ennis,TX 11/03/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Fontana,CA 1110112016 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shinizies: 4.1.1 Marquis" WeatherMaxO, Royal Sovereign' and Sentinel" are a fiberglass reinforced 3-tab asphalt roof shingles. 4.1.2 Camelot"; Camelot® 11, Fortitude"", Glenwood"", Grand Canyon", Grand Sequoia', Grand Sequoia" IR, Grand Sequoia" ArmorShieldTm, Monaco", Sienna", Timberline® American Harvest", Timberline,, ArmorShield"*11,Timberline'Natural Shadow",-Timberline Hp®,Timberline"Cool Series',Timberline Ultra HDI and Woodland"are fiberglass reinforced,laminat+'�ed asphalt roof shingles. 4.1.3 Slateline"is a fiberglass reinforced S-tab asphalt roof shingle. 4.2 Hip&Ridge Shingles 4.2.1 Seat-A-Ridge" Ridge Cap Shingles, Seal-A-Ridge" IR Impact-Resistant Ridge Cap Shingles, Seal-A-Ridge" ArrnorShlelds Ridge Cap Shingles and Timbertex"Premium Ridge Cap Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. Exterior Research and Design,LLC. Evaluation Report 01506.02.08-822 Certificate of Authorization#9503 6"EDITION(2017)FOC NON-HVHZ EVALUATION FU0124-R20 GAF Asphalt Roof Shingles Revision 22:0912012017 Page 3 of 6 4.3 Accessory Starter Strips: 4.3.1 Pro-Start"Eave/Rake Starter Strip Shingles and WeatherBlocker'"Premium Eave/Rake Starter Strip Shingles are starter strips for asphalt roof shingles. 4.3.2 QuickStartO Peel & Stick Starter Roll is a is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS modified bitumen starter strip,nominal 9-inch x 33 ft roll,for use with asphalt shingles with exposure of 6- inch or less. 4.3.3 Starterivlatch"' Starter Strip Shingles are color-coordinated starter strips for use with Grand Canyon®and Grand SequoiaO series asphalt shingles. StarterMatch— are installed as the second starter for Grand Canyon's and Grand SequoiaO series installations. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for.any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for use in all wind zones up to Vaud=150 mph(V„it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 The GAF hip&ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for use in all wind zones up to V�,Sd=150 mph(V,it=194 mph). Refer to Section 6 for Installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies only to exposure category B or C,as defined in FBC 1609.4.3,.and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or 8905.2.3. 6.2 Starter Shingles or Starter Strip: 6.2.1 Installation of Pro-Start Eave/Rake Starter Strip Shingles,WeatherBlocker Premium Eave/Rake Starter Strip Shingles and Quick5tart Peel&Stick Starter Roll shall comply with the GAF current published instructions. 6.3 Asphalt Shingles. 6.3.1 installa€ion of asphalt shingles shall comply with the GAF current published instructions,using minimum four (4)nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions: ➢ Camelot,Camelot 11,Grand Canyon,Grand Sequoia,Grand Sequoia IR,Grand Sequoia Armor5hleld, and Woodland require minimum five(5)nails per shingle. ➢ Slateline requires minimum six(6)nails per shingle. i 6.3.2 Fasteners shall be in accordance with manufacturer's published requirements,but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the GAF for details. Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R22 f Certificate OfAuthorlmBon#9503 6r"EDITION(2017)FBC NON44VHZ EVALUATION F1.10124-1120 $ GAF Asphalt Roof Shingles Revision 22:09/20/2017 Page 4 of 6 LERD 6.4 Nip-&.Ridge Shingles: 6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles,Seal-A-Ridge IR Impact-Resistant Ridge Cap Shingles and Seal-A-Ridge ArmorSh(eld Ridge Cap Shingles shall comply with the GAF current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and nominal 0.25-inch diameter beads of Henkel"Loctite Pl.S30 Roof&Flashing Sealant . Sealant pwiants A25nin) Encfaft crdlatmh#116 iNn: -�k Nail clivo 6.4.2 installation of Timbertex Premium Ridge Cap Shingles shall comply with GAF current published instructions with a minimum two(2)nails,minimum 3/8-inch head diameter, per shingle and beads of Sonneborn NP1 Gun Grade Polyurethane Sealant or Henkel Pl.Roofing and Flashing Sealant. tmu ov'I. '2,5 rim', � 425nm I A fir" ..............- 6.4.3 Fasteners shall be in accordance with GAF published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. Exterior Research and Design,U.C. Evaluation Report 01506.01.08-R22 CertUlcate of Authorizatiba#9503 e"EDITION(2017)FSC NON-HVHZ EVALUATION FLI0124-RZD GAF Asphalt Roof Shingles Revision 22:09/20/2017 Page 5 of 6 —F\Ll TIRINTY.'r-l"' 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table I507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to property evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 6I020-3 QA requirements. 10, QUALITY ASSURANCE ENTITY: U L LLC–QUA9625;(847)664-3281 END OF EVALUATION REPORT- yy Exterior Research and Design,LLC. Evaluation Report 01506.01.09422 Certificate plAutharizattan 99503 6`"EDITION(2017)F13C NON-liVHZ EVALUATION FU0124-420 GAF Asphalt Roof Shingles ReVISIDn 22:09/20/2017 Page 6 of 6 Florida Building Code Online Page I of 2 Bas Nome E,Log to I user it"Istration Het Topics Submit Surcharge Stats&Pacts Publication°r Fac stair i Bets Site Map Links{ Search + Y Product Approval USEW.Public User e � product Aoo ov!Ment>ort dtict o Agn icat'on SPAM>ApoNcation t isi>ApPlieatlon Detail { $ Fl-# FL15487-R6 ` Application Type Revision Code Version 2017 Application Status Approved W031M gr 11L Ar '% Comments L Archived ❑ F. .t UU, Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parisppany,N3 07054 (800)766-3411 mstieh@gaf.com Authorized Signature Robert Nieminen iindar@nemoetc.com Technical Representative William Broussard Address/Phone/Email 1 Campus Drive Parsippany,N3 07054 (800)766-3411 Tech nica{QuestionsGAF@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Undedayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 05/24/2019 Validated By Sohn W.Knezevich,PE 8 Validation Checklist-Hardcopy Received Certificate of Independence FLA 5487 R66 COI 2017 O1 COI Niemtnen.odf Referenced Standard and Year(of Standard) 51landard leart ASTM D226(physicals) 2009 ASTM D4533(tear) 2015 Equivalence of Product Standards 'i Certified By Sections from the Code a htt •//www.floridabuildin .or r/ r a dtl.as x? aram=wGEVX wtD to %2bDhVR 3/26/2018 p• gP P PP_ P P Q 9 P Q x f Florida Building Code Online Page 2 of 2 Product Approval Method Method 1 Option D Date Submitted 12/1512017 Date Validated 12/18/2017 Date Pending FDC Approval 12/21/2017 Date Approved 02/13/2018 Summa ry of Products FL# Model,Number or Name Description 15487.1 GAF Synthetic Roof Underlayments Synthetic Roof Underlayments Limits of use Installation instructions Approved for use in kiv"Z:No FL15497— R6 11 2017 12 FINAL ER GAF Synthetic Approved for use outside HVHZ.Yes Undedayments R-15487-116,nd Impact Resistant:N/A Verified By:Robert Nlemmen PE-59166 Design Pressure.N/A Created by Independent Third Party,Yes Other.Refer to ER Section 5 for Limits of Use. Evaluation Reports FLIS487 R6 AF 2017 12 FINAL ER GAP Synthetic Underlayments 171.15497-116,rid Created by Independent Third Party:Yes Beck Next CrIntask us::maj Blair stone AoU_Tallahassee PI 3239qPhone:a5V-467-i824 The State of Florida is an AMEEO employer.CtayrMlt 2007-201.3 State of Fforlda.::Privacy statement::Amessibility sutter-at:;Refund Statement under Florida law,email addresses are public records.it you do not want your e-mail address released to response to a pubbe-retards request,do not send electronic mail to this entity,instead,contact the office by phone or by traditional mall.It you have arty questions,please contact 850.487.13EI5.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have am.The emalts provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To detemine If you are a licensee under Chapter 455,F.S.,please click DEL. Product Apprwal Aroapts. http://www.floridabuilding.org/pr/pr_aVp—dti.aspx?Param=WGEVXQWtDqtep%2bDhVRQ... 3/26/2018 CoPWYERR RESEARCH&DESIGN,LLC. A LE Certificate ofAuthorization#9503 3S3CHRISTIAN STREET,UNIT#l3 �] ��� ~� D'8�I��8k � � ^-- '— OXFORD,CT 06478 ^ (2O3)262-924G EVALUATION REPORT GAF Evaluation Report 01506.03.12-R6 I Campus Drive FLIS'187-116 Parsippany,NJ 07054 Date of Issuance:04/23/2012 (800)766-3411 Revision 6:12/25/2017 SCOPE! This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nleminen, P.E. for use of the product under the Florida Building [ode and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6mEdition (2017) Florida Building Code sections noted herein. oscmpnom: GAF Synthetic Rmofopderleymewt LAacums: Labeling shall be in accordance with the requirements the Accredited Oma|Ky Assurance Agency noted herein. ComnmocmCommuxwc : ThisEva|oat|onReportisva|idurtUsuchdmeasthenamedproduct(s)chenges,the referenced Quality Assurance documentatnnchongos orprovisions ufthe Code that relate tnthe product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen' P.E. if the product changes orthe referenced Quality Assurance ducumenmtnnchanOes' Trinity\ERDrequires acomplete review cf this Evaluation Report relative toupdated Code requirements with each Code Cycle. AowennSmomnTheEvu|uaUonReportnumberp,ecededbytbevwords^Trnity|ERDEva|uated" maybedbplayedin advertising literature. Vany portion ofthe Evaluation Report\sdisplayed,then it shall hedone inits entirety. imspsonmmcUpon request,acopy cf this entire Evaluation Report shall beprovided to the user bythe manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists ofpages 1through 6' Prepared by: v Robert J,M.Niem|*en,P.E. n=mcsimite se*appearing was authorized u,Robert mx�an«smm�mrwusy2e��o*�,DCA xw��o ' w*rni""'nc""cvzv20zzThis does°*"erve="" y"ctt"m=0v sIgn"oaoc."°m. CERWICAMOmOFINDEPENDENCE: z. Trinity\cnD does not have, nu, does it intend to acquire or will it acquire, a financial interest in any company manufacturing vrdistributing products itevaluates. Z. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 5. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. ^. Robert Nieminen,p.E.does not have, nor will acquire,ufinancial interest inany other entity involved inthe approval process cfthe product. s. This is a building code evaluation. Neither Tiinitv|ERD nor Robert Nieminem, P.E. are, in anyway the Designer of Record for any project on which this Evaluation Report, orprevious versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: GAF Synthetic Roof Underlayments,as produced by GAF,have demonstrated compliance with the following sections of the e Edition(2017)Florida Building Code through testing In accordance with the applicable sections of the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Prope Standard Year 1507.1.1,T1507.1.1 Unrolling,Breaking Strength, ASTM D226 2009 Pliability I507.1.1 Tear Strength ASTM D4533 2015 3. REFERENCES: gatitt Examination Reference Date ERD CW 6049) Physical Properties R3360.02.07-2-RI 03/13/2007 ERD(TST 6049) Physical Properties 612110.12.08 12/02/2008 PRI(TST 5878) Physical properties BRY-003-02-01 03/19/2002 PRI(TST 5879) Physical properties GAF-224-02-01 07/27/2009 PRI(TST 5878) Physical properties GAF-349-02-01 07/03/2012 PRI(TST 5878) FBC 1507.1.1(Exception) GAF-818-02-01 12105/2017 ITS(TST 1509) Physical properties 100259583COQ-0I0A 01/11/2011 Miami-Dade(CER 1592) HVHZ compliance 16-1213.04 11/16/2017 Miami-Dade(CER 1592) HVHZ compliance 16-1216.02 02102/2017 ICC-ES(EVL2396) IBC/IRC compliance ESR-2053 07/01/2017 ICC-ES(EVL2396) IBC/IRC compliance ESR-2808 07/01/2017 [CC-ES(EVL2396) IBC/lRC compliance ESR-3286 02/01/2017 UL,LLC(QUA 9625) Quality Control 810689,Charleston,SC 06116/2017 UL,LLC(QUA 9625) Quality Control R10689;North Bay,ON 04/05/2017 UL,LLC(QUA 9625) Quality Control R10689;Fontana,CA 07/07/2017 UL,LLC(QUA 9625) Quality Control R10689;McGregor,TX 05124/2016 UL,LLC(QUA 9625) Quality Control R10689,Pryor,OK 06/20/2017 UL,LLC(QUA 9625) Quality Control R10689;Mission,BC 06/27/2017 4. PRODUCT DESCRIPTION: 4.1 Deck-Armor*"' Premium Breathable Roof Deck Protection is a non-woven, spun-bonded polypropylene laminated polyethylene scrim sheet roof underlayment, available in 48-inch or 54-inch roll widths;meets FBC 1507.1.1(Exception). 4.2 RoofPrd'SBS-Modified All-Purpose Underlayment is a fiberglass-reinforced,SBS modified bitumen roof underlayment;meets AC165. 4.3 Shingle-Mate" Roof Deck Protection is a fiberglass reinforced, asphaltic roof underlayment; meets FBC 1507.1.1(Exception). 4.4 StormS06Anchor Sheet is a polypropylene woven fabric which serves as an anchor sheet in two-ply roof underlayment systems;meets FBC 1507.1.1(Exception). 4.5 TigerPaw"" Roof Deck Protection is a non-woven, polypropylene reinforced, polymer coated roof underlayment;meets FBC 1507.1.1(Exception). Exterior Research and Design,LLC. Evaluation Report 015015.03.12lit6 Certftate of Authorization#9503 15PEDITION(2017)FBC NON-HVHZ EVALUATION FLIS487-R6 GAP Synthetic Roof Underlayments Revision 6:12/75/2027 Page 2 of 6 = Tw^^" `m n ^ �—~ D 5' UMnnnomS: 5.1 This ba.building node evaluation. Neither Trinity|ERD nor Robert mi6minen, P.E. are, in any way, the Peyigner.cf Record for any project unwhich this Evaluation Report, n,previous versions thcrcof, us/w^^ used for permitting o,design guidance unless retained specifically for that purpose. 5,2 This Evaluation Report isv,tfor use inFBCHYMZjurisdictions. 5.3 Re Classification is not part of this Evaluation nepnrt; refer mmcurrent Approved Roofing Materials Directory ortest report from accredited testing-agency for fire ratings ofthis product. SA GAF Synthetic mmcf un6wrlwxmema may he used with any prepared roof cover where the product.is specifically refepenruci within Facappnma| documents. Ifnot listed, a request may be made uothe Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.s Allowable Roof Covers: TA BLE1. ROOF COVER OPTIONS Asphalt Foam-On Wood State or Underlayment Shingles Nail-On Tile Tile Metal Shakes& Simulated Shingles Slate Deck-Armor—Premium Corft Mfg Breathable Roof Deck Yes N ontact Mfg Contact Mfg ct Protection RoofPro-SBS-Modified AJI-Purpose es —Yes. Underlayment Shingle-Mate"Roof Deck Protection Tiger Paw�Roof Deck ct J. Protection 5.6 Exposure Limitations. Deck-Armor" Premium Breathable Roof Deck Protection; Ronfpnf° SBS-Modified /4|'Pwrpcoe Undedayment, Shing|c'K8auw° Roof Deck Protection;Stormsafe� Anchor Sheet; Tiger powy" Roof mm± Protection shall not bcleft exposed for longer than 3O-dayoafter installation. 6. ImsTAuuAT/om/ 6.1 ao* Synthetic Roof mndeMammeutsshaU be installed in accordance with GAF published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly mmremove any dust and debris prior toapplication. 63 Deck Armor",Pirernium Breathable Roof Deck Protection:., 6.3.1 Shall be installed in =�Iiance�Zh the requirements for ASTM D226,Type I or 11 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed,taking into account the wider sheet- width fnrdvub|e|ayerapphcatioos 6.3.2 ramenes shall be 1-inch diameter plastic-capped corrosion resistant nails or 1-inch diameter plastic- capped,corrosion resistant staples. Exterior Research and Design,LLC. Evaluation Report 01506.03.12-R6 Certificate afAumorizatlan^9503 15'm EDITION(201qFOC NON-HVHZ EVALUATION FLIS487-R6 GAF Synthetic Roof uou=lavmwots Revision s'12/15/ou7 Page sof 6 l .TP1 ERD 6.3.3 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of Liberty''SBS Self- Adhering Base/Ply Sheet;StormiSuard®Film Surfaced Leak Barrier,UnderRoof`"2 Polyester-Surfaced Leak Barrier;UnderRoofl HT High Temperature Leak Barrier;WeatherWatch®Mineral Surfaced Leak Barrier or WeatherWatch®XT Mat Surfaced Leak Barrier at vulnerable leak areas,including but not limited to eaves, valleys,rakes,skylights and dormers. At eaves and valleys,install the leak barrier prior to installation of the underlayment. Along the rake,install the underlayment,leaving 6 to 8-inch of the deck exposed,and then install the leak barrier over the underlayment and exposed decking. At other areas, install the leak barrier over the underlayment. Refer to FL10626. 6.3.4 Non-Tile Roof.installations: Single Laver Roof Slope>4:12: Starting at the eave,fasten the eave edge and 6-inch wide end-laps 6-inch o.c.Fasten in the field of the roll 12-inch o.c.in two,equally spaced,staggered center rows. Continue upslope in a similar manner, maintaining minimum 3-inch side-laps and minimum 6-inch end- laps. Fasten 6-inch o.c.in the laps and 12-inch o.c.in two,equally spaced,staggered center rows in the field. Ensure all end laps are staggered at least 3-feet apart. Double Laver:2:12<Roof Slope<.4:12: if leak barrier (6.3.3) is not used, install a half-width sheet at the eave prior to subsequent courses. Starting at the eave,fasten the eave edge and 6-inch wide end-laps 6-inch o.c.Fasten in the field of the roil 12-inch o.c.in two,equally spaced,staggered center rows. Continue upslope in a similar manner,with minimum 25.5-inch side-laps for 48-inch wide rolls(resulting in maximum 22.5-inch exposure) or minimum 28.5-inch side-laps for 54-inch wide rolls (resulting in maximum 25.5-inch exposure) and minimum 6-inch end-laps. Fasten 6-inch o.c.along the low edge and end laps and 12-inch o.c.in two,equally spaced,staggered center rows in the field. Ensure all end laps are staggered at least 3-feet apart. 6 4;. Tiger Paw""ltaof Deck Prntetlon 3 .; w . 6.4.1 Shall be installed in compliance with the requirements for ASTM D226,Type I or li underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed,taking into account the wider sheet- width for double-layer applications. 6.4.2 Fasteners shall be 1-inch diameter plastic-capped corrosion resistant nails or 1-inch diameter plastic- capped,corrosion resistant staples. 6.4.3 Optional, or if required by the Authority Having Jurisdiction: install a leak barrier of Liberty— SBS Self- Adhering Base/Ply Sheet;StormGuardm Film Surfaced Leak Barrier;UnderRoof``2 Polyester-Surfaced Leak Barrier;UnderRoof�°"HT High Temperature Leak Barrier;WeatherWatch®Mineral Surfaced Leak Barrier or WeatherWatch®XT Mat Surfaced Leak Barrier at vulnerable leak areas,including but not limited to eaves, valleys, rakes,skylights and dormers. At eaves and valleys,install the leak barrier prior to installation of the underlayment. Along the rake,install the underlayment,leaving 6 to 8-inch of the deck exposed,and then install the leak barrier over the underlayment and exposed decking. At other areas,install the leak barrier over the underlayment. Refer to FL10626. 6.4.4 Non Tile Roof installations: Single Laver.Roof Slope>4:12: Starting at the eave,fasten the eave edge and 6-inch wide end-laps 6-inch o.c.Fasten in the field of the roll 12-inch o.c.in two,equally spaced,staggered center rows. Continue upslope in a similar manner, maintaining minimum 3-inch side-laps and minimum 6-inch end- laps. Fasten 6-inch o.c. in the laps and 12-inch o.c.in two,equally spaced,staggered center rows in the field. Ensure all end laps are staggered at least 3-feet apart. { Exterior Research and Design,I.I.C. Evaluation Report 01506.03.12-86 CertificoteofAuthorization#9503 6'"EDITION(2017)FBC NON-HVH2 EVALUATION F1.15487-116 GAF Synthetic Roof Underlayments Revision 6:12/15/2017 Page 4 of 6 1 i ERD Double Laver:2:12<Roof Slope c 4:12: If leak barrier.(6.4.3) is not used, install a half-width sheet at the eave prior to subsequent courses. Starting at the eave,fasten the eave edge and 6-inch wide end-laps 6-inch o.c.Fasten in the field of the roll 12-inch o.c.in two,equally spaced,staggered center rows. Continue upslope in a similar manner,with minimum 25.5-inch side-laps(resulting in maximum 22.5-inch exposure)and minimum 64nch end-laps. Fasten 6-inch o.c.along the low edge and end laps and 12-inch o.c.in two,equally spaced,staggered center rows in the field. Ensure all end laps are staggered at least 3- feet apart. 6 5 - StomR5afe""-Anchoi�6heet �, 6.5.1 StormSaf0l Anchor Sheet is limited to use as a mechanically attached base layer in 2-01y underlayment systems. 6.5.2 Fasteners shall be 1-inch diameter plastic-or steel-capped corrosion resistant nails; corrosion-resistant nails&1-5/8-inch tin-caps;or Drill-Tec screws and plates. 6.5.3 Non-Tile Roof installations: Starting at the eave,fasten the eave edge and 6-inch wide end-laps 6-inch o.c.Fasten in the field of the roll 12-inch o.c.in two,equally spaced,staggered center rows. Continue upslope in a similar manner, maintaining minimum 3-inch side-laps and minimum 6-inch end- laps. Fasten 6-inch o.c. in the laps and 12-inch o.c.in two,equally spaced,staggered center rows in the field. Ensure all end laps are staggered at least 3-feet apart. One the same day, install Liberty'SBS Self-Adhering Base/Ply;StormGuarW® Film Surfaced Leak Barrier; UnderRoof°- HT High Temperature Leak Barrier; WeatherWatch® Mineral Surfaced Leak Barrier or WeatherWatchO XT Mat Surfaced Leak Barrier over the StormSafe"-Anchor Sheet. Refer to FL10626. 6:6 RoofPi6 SBS-Modified All-Purpose'Underlayment'and Shirr!e M ateO Roof Deck Protection 6.6.1 Shall be installed in compliance with the requirements for-ASTM D226,Type I or 11 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. No hammer tacks or staples are permitted. 6.6.2 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of UbertyT" SBS Self- Adhering Base/Ply Sheet;StormGuardO Film Surfaced Leak Barrier,UnderRoof' HT High Temperature Leak Barrier;WeatherWatchO Mineral Surfaced Leak Barrier or WeatherWatch'XT Mat Surfaced Leak Barrier at vulnerable leak areas,including but not limited to eaves,valleys,rakes,skylights and dormers. At eaves and valleys, install the leak barrier prior to installation of the underlayment. Along the rake, install the underlayment, leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the underlayment and exposed decking. At other areas,install the leak barrier over the underlayment. Refer to FL10626. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 'i Exterior Research and Design,LLC. Evaluation Report 01506.03.12-R6 Certificate of Authorization X9503 6t"EDITION(2017)FSC NON4HVH2 EVALUATION FUS"7-116 GAF Synthetic Roof Underlayments Revision 6:12/15/2017 Page 5 of 6 s R-jj !ERD 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C.61620-3 CA requirements. The following plants have qualified products under their respective physical properties specifications. ilaiit S`oecification:__ ProduiMsj North Bay,Ontario FBC 1507.1.1(Exception) Deck-Armor'"Premium Breathable Roof Deck Protection,StormSafe" Anchor Sheet Fontana,CA AC165 RoofProTM SBS-Modified All-Purpose Underiayment Pryor,OK FBC 1507.2.1(Exception) Shingle-Mate*Roof Deck Protection McGregor,TX FBC 1507.1.1(Exception) Shingle-Mateo Roof Deck Protection Mission,BC FBC 1507.1.1(Exce(Exception) Tiger PawTM Roofi Deck Protection Charleston,SC FBC 1547.1.1(Exception) Tiger PawTM Roof Deck Protection 9. QUALITY ASSURANCE ENTITY: UL,LLC.—QUA9625;(847)664-3281 •END OF EVALUATION REPORT- '3 s 1 t i I Exterior Research and Design,LLC. Evaluation Report 01506.0312-R6 CeWflcote ojAutharization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FLLW7-R6 GAF Synthetic Roof Underiayments Revision 6:22/2Sf 2017 Page 6 of 6