Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2 "Ail Ka- . r :. .:. . BCIS Home I Log In I User Registration Hot Topics ( Submit Surcharge Stats&Facts Publications I Contact Us j BCIS Site Map I Links Search Florida ;� r !;", ;;9 Product Approval,� 1,�g fte USER:Public User U.^�o�SsaN�� Product Aooroval Menu>Product or Aoolication Search>Aonlication List>Application Detail 1> FL# FL18355-R4 Application Type Revision Code Version 2017 Application Status Approved Comments Archived ❑ Product Manufacturer TAMKO Building Products,Inc. Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri—eden@tamko.com Authorized Signature Kerr!Eden kerri_eden@tamko.com Technical Representative Kerri Eden Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri—eden@tamko.com Quality Assurance Representative Address/Phone/Emall Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Zachary R.Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/18/2021 Validated By Locke Bowden P.E. © Validation Checklist-Hardcopy Received Certificate of Independence FL18355 R4 COI TBP15001.4 2017 FBC Eval Report Shinqles final.odf Referenced Standard and Year(of Standard) Standard Year ASTM D 3161 2016 ASTM D 3462 2010 ASTMD D 7158 2011 TAS 100 1995 Equivalence of Product Standards Certified By Approved Testing Lab FL18355 R4 Eauiv UL letter for standards for FBC 2017.gdf Sections from the Code https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquvosrHazGX... 12/10/2018 Florida Building Code Online Page 2 of 2 Product Approval Method Method 1 Option D Date Submitted 09/25/2017 Date Validated 09/27/2017 Date Pending FBC Approval 10/08/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 18355.1 Glass-Seal,Elite Glass-Seal, ASTM D 3462 asphalt shingles and hip and ridge shingles Heritage,Heritage Premium, Heritage Woodgate,Heritage Vintage,Hip and Ridge,and Vintage Hip and Ridge Shingles Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL18355 R4 II TBP15001.4 2017 FBC Eva]Reoort Shingles Approved for use outside HVHZ:Yes final.odf Impact Resistant:N/A Verified By: Zachary R.Priest PE-74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL18355 R4 AE TBP15001.4 2017 FBC Eva[Reoort Shingles final.Ddf Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road.Tallahassee Fl.32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: WE ® aCh`xt M T Credit Card V� Safe. https://www.floridabuilding.org/pr/pr�--app—dtl.aspx?pa rarn­—wGEVXQwtDquvosrHazGX... 12/10/2018 r— Certificate of Authorization No.29824 CREEK 17520 Edinburgh Dr Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,6'EDITION(2017) Manufacturer: TAMKO BUILDING PRODUCTS Issued September 25, 2017 220 West 4th Street Joplin, MO 64801 (417)624-6644 Manufacturing Plants: Joplin,MO ' Phillipsburg,KS Frederick, MD Dallas,TX Tuscaloosa,AL Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: Asphalt Shingles Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1, 1523.6.5.1 Properties: Physical properties,Wind Resistance,Wind Driven Rain REFERENCES Enti N Report No. Standard Year PRI Construction Materials Technologies(TST5878) TAP-043-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-051-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-054-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-114-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-117-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-130-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-131-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-165-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-280-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-303-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-307-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-314-02-01 Rev 2 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-315-02-01 ASTM D 6381 2008(2013)e1 PRI Construction Materials Technologies(TST5878) TAP-317-02-01 TAS 100 1995 UL LLC(TST9628) 02NK9507 ASTM D 3161 2016 UL LLC(TST9628) 04NK24366 ASTM D 3462 2010A UL LLC(TST9628) 05NK28006 ASTM D 6381 2008(2013)e1 UL 2390 ASTM D 7158 2011 UL LLC(TST9628) 06NK03898 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC(TST9628) 08CA59132 ASTM D 3161 2016 UL LLC(TST9628) 09NK07896 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC(TST9628) 10CA50498 ASTM D 3462 2010A UL LLC(TST9628) 10CA64882 ASTM D 3161 2016 UL LLC(TST9628) 11NK14014 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC(TST9628) 12CA24551 ASTM D 3161 2016 UL LLC(TST9628) 4786110543 ASTM D 6381 2008(2013)e1 UL LLC(TST9628) 4787043752 ASTM D 3161 2016 UL LLC(TST9628) 4787148748 ASTM D 7158 2011 ASTM D 3161 2016 ASTM D 3462 2010A CREEK Technical Services LLC(ANE11669) TBP15001.3 Calculations 2017 TBP15001.4 FL18355-R4 Page 1 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. D Y TAMKO BUILDING PRODUCTS' 1 1 I 1 Asphalt Shingles TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION Elite Glass-Seal® 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick,Joplin& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass-Seal 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass-Seal 12-1/4"x 36", ASTM D 7158, Class H self-sealing, 3-tab asphalt shingle with fiberglass (Joplin) mat coated on both sides with asphalt and surfaced with ceramic granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Heritage® 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas,Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Joplin,Phillipsburg& complying with ASTM D 3462. Tuscaloosa) Heritage®Premium 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas,Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Phillipsburg& complying with ASTM D 3462. Tuscaloosa) Heritage®Premium 12" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Frederick) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage®Vintage® 17-1/2"x 40',ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Phillipsburg) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage®Woodgate 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas&Frederick) reinforced, laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage®Woodgate 12" x 36-3/8", ASTM D 3161, Class F fiberglass reinforced, laminated architectural (Frederick) asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Hip and Ridge Shingles 12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt (Frederick&Joplin) shingle surfaced with mineral granules complying with ASTM D 3462. Vintage®Hip and Ridge 12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle (Phillipsburg) surfaced with mineral granules complying with ASTM D 3462. TBP15001.4 FL18355-R4 Page 2 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. I I C TAMKO BUILDING PRODUCTS IIS Asphalt Shingles TECHNICAL SERVICES, LLC INSTALLATION Elite Glass-Seal® Basic Wind Speed(V„it): Max. 194 mph (Frederick,Joplin& Basic Wind Speed Msd): Max. 150 mph Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 19/32 in. plywood or wood plank for Glass-Seal new construction; Min. 15/32 in. plywood existing (Frederick,Joplin(Non- construction. HVHZ)&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min.7/16 in.OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): Installed with 5-1/8 inch exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5-1/8-inch exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. NAILS -r *-111 T� w Nailing -Area 6-718 5-118" Butt Edge Figure 1. Elite Glass-Seal&Glass-Seal 4 Nail Pattern (Non-HVHZ only) NAILS Nailing .. .- -.--.---......-........_......__..... -----------------....._... -- 6-7W Area ......... ......... ......... .......-....--- ......•-...... 5-1/8" But#Edge Figure 2. Elite Glass-Seal&Glass-Seal 6 Nail Pattern TBP15001.4 FL18355-R4 Page 3 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not specifically addressed herein. C REEK TAMKO BUILDING PRODUCTS' j� I 1 Asphalt Shingles TECHNICAL SERVICES, LLC Heritage® Basic Wind Speed(V„ic): Max. 194 mph (Dallas, Frederick,Joplin, Basic Wind Speed(Vwd): Max. 150 mph Phillipsburg&Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 19/32 in. plywood or wood plank for Heritage®Premium new construction; Min. 15/32 in. plywood existing (Dallas, Frederick construction. Phillipsburg&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 15/32 in. plywood or wood plank for Heritage®Woodgate new construction; Min.7/16 in.OSB existing construction. (Dallas&Frederick) Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): Installed with 5-5/8 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5-5/8 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or T Nail Pattern"detailed below. FASTENERSNAIL ZONE COMMON BOND EXPOSU RE 6-6/8" 12-1/211--►� 12-3/8" --►�— 12-1/2`� Figure 3. Heritage®, Heritage®Premium, and Heritage®Woodgate (Dallas) 4 Nail Pattern (non-HVHZ only) FASTENERS NAIL ZONE COMMON BOND '7 61 "7EXPOSURE 6-6/8" 1'�--1� f�-1/2'�-�f-�-112"-►h-7,1'!8"�T-1/2"-Ph-7-i/2"� �1" Figure 4. Heritage®&Heritage®Premium 6 Nail Pattern TBP15001.4 FL18355-R4 Page 4 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC NAIL�ZONEI - ASTENERS _ Cd .MON BOND EXPOSURE 5 irk"; 1=►, 71/2 -7-112`x► 7=3/8" /2 7=71 7=112 ►' �-1,!" Figure 5. Heritage®Woodgate 6 Nail Pattern -►I1-h-i-12-1/2° i i i i i i i i i i i i Common Bond FASTENERS i i i i i i T m NOx E, r 1 W 39-318" 0 I Figure 6. Heritage®, Heritage®Premium,&Heritage®Woodgate Alternate 6 Nail Pattern PAINT` LINE _:. --...:-=-----_.-.......:_... - - _ }NAIL:SONE. EDGE OF..:: COMMON - BOND EXPOSURE OMM.ON-BOND- EXPOSURE ACCEPTABLE. FASTENER LOCATION -DO NOT FASTEN ALONG:EDGE OF ------------ ---- _ COMMON'BOND :PREFERRED FASTENER LOCATION Figure 7. Heritage®(Tuscaloosa) Expanded Nail Zone Nail patterns from Figures 3,4, and 6 may be placed in the nail zone as described above TBP15001.4 FL18355-R4 Page 5 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CL7 u TAMKO BUILDING PRODUCTS' RE K Asphalt Shingles TECHNICAL SERVICES, LLC Heritage®Premium Basic Wind Speed(V„i,): Max. 194 mph (Frederick) Basic Wind Speed(Vnd): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min.7/16 in.OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. . Installation (HVHZ): Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. NAIL ZONEt FASTENERS COMMON BOND 51/2" EOSURE 5" �- 11" - 12" ill,--q k--1" Figure 8. Heritage®Premium (Frederick) 4 Nail Pattern (non-HVHZ only) NAIL ZONE/ FASTENERS COMMON BOND ,r,� 51/2" EXPOS E 5" 1 g" +91h1 14-11" Figure 9. Heritage®Premium (Frederick) 6 Nail Pattern TBP15001.4 FL18355-R4 Page 6 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. I ' CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC Heritage®Woodgate Basic Wind Speed(V„,,): Max. 194 mph (Frederick) Basic Wind Speed(Vnd): Max. 150 mph Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction;Min.7/16 in.OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either'A Nail Pattern"or"6 Nail Pattern"detailed below. NAIL ZONE/ FASTENERS /OMMONBOND EXPOSURE Y Figure 10. Heritage®Woodgate(Frederick) 4 Nail Pattern (non-HVHZ only) NAIL ZONE/ FAVENEAS COMMON BOND 5'112" EXPOSURE 5' 1""►' �' 9.1/2" ' 9.3/8" 3' • Figure 11. Heritage®Woodgate (Frederick) 6 Nail Pattern TBP15001.4 FL18355-R4 Page 7 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not specifically addressed herein. i L . CREEK TAMKO BUILDING PRODUCTS - Asphalt Shingles TECHNICAL SERVICES, LLC Heritage®Vintage® Basic Wind Speed(Vuit): Max. 194 mph (Phillipsburg) Basic Wind Speed (Vasa): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min.7/16 in.OSB existing construction. Underla ment: In accordance with FBC requirements. Y q Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"5 Nail Pattern"or"6 Nail Pattern"detailed below. 4d` it ug rent Egowe :R N31ch Fastams --— ——— — — — — — i - - — — v-trz^ s rxpasvle Qt,a• Qur• 9.111`—r�—?tro` �+--toga•"''{ �+—to-va•—a{ Figure 12. Heritage®Vintage® 5 Nail Pattern (non-HVHZ only) Notdf Area ur�tr r 6' ^°R Nati Zane 17-1/2' s t- ��lr—.� Figure 13. Heritage®Vintage° 6 Nail Pattern TBP15001.4 FL18355-R4 Page 8 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 3 CREAK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC Hip&Ridge Basic Wind Speed(V„it): Max. 194 mph (Frederick&Joplin) Basic Wind Speed(Vasd): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction;Min.7/16 in.OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Installation: Installed with 5-1/8 inch exposure in accordance with the FBC and manufacturer's published installation instructions. The direction of the exposed end shall be away from the prevailing wind. Direction prevailing wind Start �5-1/8" exposure here Start Figure 1 here 5-1/8"exposure 1„ ``''••? Fastener ? Fastener Figure 2 4 Figure 3 n Figure 14. Hip&Ridge(Frederick&Joplin) TBP15001.4 FL18355-R4 Page 9 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes'or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use, or other product attributes that are not specifically addressed herein. z DEEK TAMKO BUILDING PRODUCTS 1 1 Asphalt Shingles TECHNICAL SERVICES, LLC Vintage®Hip$Ridge Basic Wind Speed(V„it): Max. 194 mph (Phillipsburg) Basic Wind Speed Msd): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min.7/16 in.OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Installation: Installed with 5 inch exposure in accordance with the FBC and manufacturer's published installation instructions. The direction of the exposed end shall be away from the prevailing wind. Direction of prevailing wind hart. 511exposure In—] Start Figure 1 here 51 exposure 1" Fastener �I Fastener �5-1/21, Figure 2 1/4" Figure 3 Figure 15. Vintage®Hip & Ridge(Phillipsburg) TBP15001.4 FL18355-R4 Page 10 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. i ' j' CREljjj� TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ. 4) Classification to ASTM D 7158 applies to exposure B&C with a building mean roof height of 60-ft or less. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the deck. 7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and code compliant detail shall prevail. 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code,6t'Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. ,,,,G?P�C'ENS 9r�s�•� _ s .........2017.09.25 • No 74021 11 :31 :41 —04'00' 00:. STATE OF •'•:°� Q:•'����� Zachary R. Priest,P.E. ���cS• ' R �� Florida Registration No.74021 Organization No.ANE11669 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E.does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT TBP15001.4 FL18355-R4 Page 11 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. Florida Building Code Online Page 1 of 2 III BCIS Home I Log In User Registration I Hot Topics � Submit Surcharge ( Stats&Facts Publications I Contact Us � BCIS Site Map I Links 1 Search � Florida r Product Approval IUSER:Public User EP rzllam Product Approval Menu>Product or Application Search>Application Lis[>Application Detail FL# FL5259-R28 Application Type Revision Code Version 2017 Application Status Approved Comments Archived ❑ Product Manufacturer POLYGLASS USA Address/Phone/Email 1111 W.Newport Center Drive Deerfield Beach,FL 33442 (954)233-1330 Ext 242 malpert@polyglass.com Authorized Signature Maury Alpert malpert@polyglass.com Technical Representative Maury Alpert Address/Phone/Email 1111 W.Newport Center Drive Deerfield Beach,FL 33442 (912)429-8610 MAIpert@polyglass.com Quality Assurance Representative Ariel Lender Address/Phone/Email 1111 W.Newport Center Drive Deerfield Beach,FL 33442 (954)233-1230 ALender@polyglass.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 09/13/2021 Validated By John W.Knezevich,PE © Validation Checklist-Hardcopy Received Certificate of Independence FL5259 R28 COI 2018 01 COI NIEMINEN.odf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D226 2009 ASTM D4798 2011 ASTM D6164 2011 ASTM D6222 2011 FM 4474 2011 FRSA/TRI April 2012 2012 UL 1897 2012 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3 C... 12/10/2018 Florida Building Code Online Page 2 of 2 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 01/24/2018 Date Validated 01/29/2018 Date Pending FBC Approval 01/30/2018 Date Approved 04/10/2018 Summary of Products FL# Model,Number or Name Description 5259.1 Polyglass Roof Roofing underlayments Underlayments Limits of Use Installation Instructions Approved for use in HVH2:No FL5259 R28 II 2018 01 FINAL ER POLYGLASS UNDERLAYMENTS FL5259- Approved for use outside HVH2:Yes R28.Ddf Impact Resistant:N/A Verified By: Robert Nieminen PE-59166 Design Pressure:+N/A/-622.5 Created by Independent Third Party:Yes Other: 1.)The design pressure in this Evaluation Reports application relates to one particular FL5259 R28 AE 2018 01 FINAL ER POLYGLASS UNDERLAYMENTS FL5259- underlayment system(over concrete deck) R28.odf for use under foam-on tile systems(where Created by Independent Third Party:Yes the underlayment forms part of the load- path).Refer to ER Section 5.6.4 for other systems,other deck types and associated maximum design pressures.2.)Refer to ER Section 5 for other limits of use. Beck Naxt Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: L=_j FM R9 Im Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3 C... 12/10/2018 ' f NEMO I etc. Certificate of Authorization#32455 353 Christian Street, Unit#13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALUATION REPORT Polyglass USA,Inc. Evaluation Report P12060.02.09-R24 1111 West Newport Center Drive FL5259-R28 Deerfield Beach, FL 33442 Date of Issuance:02/24/2009 (954)233-1230 Revision 24:01/24/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMOJetc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 14. Prepared by: ,►,+�+�+1�;��,,,,— Robert J.M.Nieminen P.E. = ..• �: Nieminen, •j0� c.�.i�1 The facsimile seal appearing was authorized by Robert Nieminen, Florida Registration No.59166, Florida DCA ANE1983 1hS�� :•`E��;c P.E.on 01/24/2018. This does not serve as an electronically ''diu� ,�„ •, 4--,- signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMOJetc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. MEMO I etc.is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMOIetc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. NNEMOletc. ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Uplift FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.2.3/1507.1.1 Physical Properties ASTM D226 2009 1507.2.4/1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 2012 1507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Physical Properties ASTM D6222 2011 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Entity Examination Reference Date FM Approvals(TST 1867) Wind Uplift 3004091 01/12/2000 PRI(TST 5878) Physical Properties PRIO1111 04/08/2002 PRI(TST 5878) Physical Properties PUSA-005-02-01 01/31/2002 PRI(TST 5878) Physical Properties PUSA-013-02-01 12/23/2002 PRI(TST 5878) Physical Properties PUSA-013-02-02 12/23/2002 PRI(TST 5878) Physical Properties PUSA-013-02-03 12/23/2002 PRI(TST 5878) Physical Properties PUSA-018-02-01 07/14/2003 PRI(TST 5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI(TST 5878) Physical Properties PUSA-033-02-01 01/12/2006 PRI(TST 5878) Physical Properties PUSA-035-02-01 09/29/2006 PRI(TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI(TST 5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI(TST 5878) Physical Properties PUSA-076-02-01 02/22/2008 PRI(TST 5878) Physical Properties PUSA-083-02-01 04/14/2008 PRI(TST 5878) Physical Properties PUSA-088-02-01 07/29/2009 MTI(TST 2508) Physical Properties JX20H7A 04/01/2008 MTI(TST 2508) Physical Properties RX14E8A 01/29/2009 ERD(TST 6049) Physical Properties 11752.09.99-1 02/08/2000 ERD(TST 6049) Wind Uplift 11757.08.01-1 08/13/2001 ERD(TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD(TST 6049) Physical Properties 02200.07.03 07/14/2003 ERD(TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD(TST 6049) Physical Properties P5110.04.07-1 04/11/2007 ERD(TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD(TST 6049) Physical Properties P13450.08.09 08/13/2009 ERD(TST 6049) Wind Uplift P30540.11.09-R1 11/30/2009 ERD(TST 6049) Physical Properties P11030.11.09-1 11/30/2009 ERD(TST 6049) Wind Uplift P11030.11.09-2 11/30/2009 ERD(TST 6049) Physical Properties P11030.11.09-3 11/30/2009 ERD(TST 6049) Physical Properties P33360.06.10 06/25/2010 ERD(TST 6049) Physical Properties P33370.03.11 03/02/2011 ERD(TST 6049) Physical Properties P33370.04.11 04/26/2011 ERD(TST 6049) Physical Properties P37300.10.11 10/19/2011 MEMO ETC,LLC. Evaluation Report P12060.02.09-R24 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 2 of 14 i ONEMOjetc. Entitv Examination Reference Date ERD(TST 6049) Physical Properties P40390.08.12-1 08/06/2012 ERD(TST 6049) Physical Properties P40390.08.12-2 08/07/2012 ERD(TST 6049) Physical Properties C41420.09.12-3 09/11/2012 ERD(TST 6049) Wind Uplift P39680.03.13 03/04/2013 ERD(TST 6049) Physical Properties P45370.04.13 04/26/2013 ERD(TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013 ERD(TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013 ERD(TST 6049) Wind Uplift P41630.08.13 08/06/2013 ERD(TST 6049) Wind Uplift P11751.05.03-R1 11/26/2013 ERD(TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013 ERD(TST 6049) Physical Properties P45270.05.14 05/12/2014 ERD(TST 6049) Physical Properties 6020.07.14-1 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-2 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-3 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-4 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-5 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-6 09/08/2014 ERD(TST 6049) Physical Properties P46520.10.14 10/03/2014 ERD(TST 6049) Physical Properties P43290.10.14 10/17/2014 ERD(TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015 ERD(TST 6049) Physical Properties P40390.04.15 04/03/2015 ERD(TST 6049) Physical Properties P44360.10.14-R1 05/18/2015 ERD(TST 6049) Physical Properties PLYG-SC8080.05.15-1 05/20/2015 ERD(TST 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016 ERD(TST 6049) Physical Properties PLYG-SC8080.07.16 07/16/2016 ERD(TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016 ERD(TST 6049) Physical Properties PLYG-SC13040.12.16 12/27/2016 ERD(TST 6049) Physical Properties PLYG-SC11900.03.17 03/10/2017 ERD(TST 6049) Physical Properties PLYG-SC12115.08.17 08/08/2017 ICC-ES(EVL 2396) IBC Compliance ESR-1697 11/01/2014 Miami-Dade(CER 1592) HVHZ Compliance NCA 14-0717.08 01/22/2015 Polyglass USA Manufacturing Affidavit Products Current 02/18/2009 Polyglass USA PA Affidavit Mule-Hide Cross Ltg 03/01/2008 Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011 UL,LLC.(QUA9625) Quality Control Service Confirmation Exp.10/05/2018 4. PRODUCT DESCRIPTION: 4.1 Mechanically Fastened Underlayments: 4.1.1 Elastobase is a fiberglass reinforced,SBS modified bitumen base sheet. 4.1.2 Elastobase P is a polyester-reinforced,SBS modified bitumen base sheet. 4.1.3 Polyglass G2 Base is a fiberglass-reinforced,asphaltic base sheet. 4.1.4 Polyglass APP Base is a fiberglass-reinforced,APP modified bitumen base sheet. 4.2 Self-Adhering Underlayments: 4.2.1 Polystick MTS or Polystick MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced,surfaced with polyolefinic film surface; meets FRSA/TRI April 2012. 4.2.2 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced,with an aggregate surface;meets ASTM D1970. 4.2.3 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. NEMO ETC,LLC. Evaluation Report P12060.02.09-R24 Certificate of Authorization#32455 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-1128 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 3 of 14 i NNW' oletc. 4.2.4 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced,with a granular surface; meets FRSA/TRI April 2012. 4.2.5 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. 4.2.6 Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet (FR) are polyester reinforced,APP modified bitumen cap sheets; meet FRSA/TRI April 2012. 4.2.7 Polystick Dual Pro'" is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced,with a polyester fabric surface; meets ASTM D1970. 4.2.8 Polystick Tile Pro" is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced,with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. 4.2.9 Polystick MU-X is a nominal 54-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section 5.8). 4.3 Mechanically Fastened and/or Bonded Underlayments: 4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of a sand-surfaced SBS modified bitumen back-side and granule-surfaced APP modified bitumen top-side. Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet" in the "Two Ply System"from FRSA/TRI April 2012(04-12) beneath mechanically fastened or adhered tile roof systems. 4.3.2 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced,SBS modified bitumen cap sheets; meet ASTM D6164. Elastoflex S6 G and Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M)in the"Single Ply System"from FRSA/TRI April 2012(04-12) beneath mechanically fastened tile roof systems. Elastoflex S6 G is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System"from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FR is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. 4.3.3 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222. Polyflex G is for use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Polyflex G FR is for use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMOIetc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. NEMO ETC,LLC. Evaluation Report P12060.02.09-R24 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 4 of 14 ONEMOjetc- 5.5 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS Underlayment Asphalt Shingles Nail-On Tile Foam-On Tile Metal Wood Shakes Slate &Shingles Elastobase Yes Yes Yes Yes Yes Yes (Base Sheet in 2-ply system) (Base Sheet in 2-ply system) Elastobase P Yes Yes Yes Yes Yes Yes (Base Sheet in 2-ply system) (Base Sheet in 2-ply system) Polyglass G2 Base No Yes Yes (Base Sheet in 2-ply system) (Base Sheet in 2-ply system) NO NO NO Polyglass APP Base No Yes Yes No No No (Base Sheet in 2-ply system) (Base Sheet in 2-ply system) Polystick MTS or MTS PLUS Yes Yes No Yes Yes Yes Polystick IR-Xe Yes No No No Yes Yes Polystick TU P No Yes Yes (See 5.5.1) No No No Polystick TU Plus Yes Yes Yes (See 5.5.1) Yes Yes Yes Polystick TU Max No Yes Yes (See 5.5.1) Yes No No Polystick Dual Pro Yes No No Yes Yes Yes Polystick Tile Pro Yes Yes Yes (See 5.5.1) Yes Yes Yes Polystick MU-X Yes No No Yes Yes Yes Elastoflex S6 G Yes Yes Yes (See 5.5.1) No Yes Yes Elastoflex S6 G FR Yes Yes No No Yes Yes Elastoflex G TU Yes Yes Yes (See 5.5.1) No Yes Yes Polyflex G Yes Yes Yes (See 5.5.1) No Yes Yes Polyflex G FR Yes Yes No No Yes Yes Polyflex SAP or SAP FR Yes Yes Yes (See 5.5.1) No Yes Yes Mule-Hide SA-APP Cap Sheet Yes Yes Yes (See 5.5.1) No Yes Yes or SA-APP Cap Sheet(FR) 5.5.1 "Foam-On Tile"is limited to use of the following Approved tile adhesives/underlayment combinations. TABLE 1A:ALLOWABLE TILE ADHESIVE/UNDERLAYMENT COMBINATIONS) Adhesive Florida Product Underlayments Approval DAP Foam Touch'n Seal StormBond Roof FL14506 Polystick TU Plus,Polystick TU Max Tile Adhesive Dow TileBond'm FL22525 Polystick TU P,Polystick TU Plus,Polyflex SAP or Tile Pro Polystick TU P,Polystick TU Plus,Polystick TU Max,Polystick Tile Pro, ICP Adhesives Polyset®AH-160 FL6332 Elastoflex G TU,Elastoflex S6 G,Polyflex G,Polyflex SAP,Polyflex SA Cap FR, Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR) Polystick TU P,Polystick TU Plus,Polystick TU Max,Polystick Tile Pro, ICP Adhesives Polyset°RTA-1 FL6276 Elastoflex G TU,Elastoflex 56 G,Polyflex G,Polyflex SAP,Polyflex SA Cap FR, Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR) 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC,I.I.C. Evaluation Report P12060.02.09-R24 Certificate of Authorization#32455 CH EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 5 of 14 ONEMOletc. 5.6 Allowable Substrates: 5.6.1 Direct-Bond to Deck: Polystick(all variations), Dual Pro,Tile Pro, Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)self-adhered to: ➢ New untreated plywood;ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). Note: Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D41 primed structural concrete. Polyflex G or Polyflex G FR torch-applied to: ➢ ASTM D41 primed structural concrete. 5.6.2 Bond-to-Insulation: Polystick(all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR)self-adhered to: ➢ ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard; Dens Deck Prime;or SECUROCK Gypsum-Fiber Roof Board. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board. Polyflex G or Polyflex G FR torch-applied to: ➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FBC Section 1504.3.1. 5.6.3 Bond to Mechanically Attached Base Laver: Polystick (all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self-adhered to: ➢ ASTM D226,Type I or II felt; Elastobase; Elastobase P or Mule-Hide Nail Base. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D226,Type I or II felt; Elastobase; Elastobase P, Mule-Hide Nail Base or Polyglass G2 Base. Polyflex G or Polyflex G FR torch-applied to: ➢ Elastobase; Elastobase P, Mule-Hide Nail Base, Polyglass G2 Base or Polyglass APP Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12),Appendix A,Table 1, or as listed in Section 5.6.4 herein, or as tested in accordance with FBC Section 1504.3.1. NEMO ETC,LLC. Evaluation Report P12060.02.09-R24 Certificate of Authorization 1132455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 6 of 14 ONEMOletc. 5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam on tile systems, where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on the applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04- 12),Appendix A,Table lA or FBC 1609 for determination of design wind loads. #1 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #2 Maximum Design Pressure=-97.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1X"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. #3 Maximum Design Pressure=-105 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB-3000 Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1%"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. #4 Maximum Design Pressure=-135 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Joints: Min.4-inch wide strips of Elastofiex SA-V over all plywood joints. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max, Polyflex SAP,Polyflex SAP FR,Mule-Nide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #5 Maximum Design Pressure- 315 ecf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Pius, Polystick TU Max, Tile Pro Polyflex SAP, Pol i #6 Sheet and Mule-Hide SA-APP Cap Sheet(FR),self adhered. Maximum D Yf ex SAP FR Mule Hide SA-APP Cl Desi n Pressure=-622,5 sf: Deck: Structural Primer: concrete to PG100 or ASTM D41 meet ro' Underia P lect regUiretlle #7 Yment:Elastofiex G htS to Satisfacti0n0 Maximo T U or Elastoflex S6 G beck: m Desi n Pressure z_ ,applied in full f A�thOr��yy Bas Min.15132 30.0 S fay, IIjQ Base sheet: enc ppin�Pfha Fasteners: Elastobas h�5B to Spavin 11 ga.x e orRule yid eetprolectreq Base P y. 6' X450125-inch io e fail Base ulfeme 0q, i Underi (o `at the °ffx�inch (poly,f.m nts to s . ayment.po ptionaii poi s .3 inch Wide head dia �l top SUrfac �dC �I Ystick lv Y trek TS de side! mererro ��I Qir �� fCOte ofAutho�! Mule l Rid, or q p0lyst(clC l U P/, Oiyst,Ck n saaps nd 6-lh�h O.C. 4, N +`, cerm�Erb�cc. �4to SI S 3z4ss CahSheetf�R)Pe°lYst" l� 'Self 10 �s tyyd� If Ma e adher k Ao a /eo�r�o� ed ,fR �X �(/�l y�/aSsRO(2o1�fF r P o"U# p�C lit"z�G� 0 e��9A �ij �IPr #8 MaximDesign Pressure _37,5 psf*- fONEMOIetc- IV Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch long x 1-Inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TUI Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #9 Maximum Desien Pressure=-37.5 psf*: Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One(1)or two(2)layers ASTM D226,Type 11 felt Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-Inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. #10 Maximum Design Pressure=-45 Psf*: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One(1)layer ASTM D226,Type 11 felt - Fasteners., 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c.at the 2-inch wide side laps and 4-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Eiastoflex G TU,applied in full mopping of hot asphalt. #11 Maximum Design Pressure=-45 psf*: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Two(2)layers ASTM D226,Type 11 felt Fasteners: 11 ga.x 1.25-inch long x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 9-inch o.c.at the 2-Inch wide side laps and 9-inch O.C.at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self-adhering underlayment only)Polystick NITS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. #12 Maximum,Design Pressure=.45 o meet project requirements to satisfaction of Authority Having Jurisdiction. Deck: Min.15132-inch plywood t hasphalt or torch-applied cap or poly-film surface for torch-applied cap) Base Sheet: Elastobase(sanded top surface for ot- Fasteners'. Simplex MAXX Cap Fasteners s and 18-inch O.C.at two(2)equally spaced staggered center rows, Spacing: 9-inch 0-c.at the 2-Inch wide side lap in full mopping of hot asphalt or polyflex G,torch-applied. �IaStojjeX G IU 0,�J,,tflex 56 G,applied satisfaction of AuthoritV Having Jurisdiction. cap) T for torch-app lied o!Sf -film surface -quIreMentS to od to Meet project M torch app cap or poly �yWo riace of bot_Asphalt 01 j staggered center rows- tly Space, to tWo�2)equally Polyflex G,torch-ap P ho spn. halt or �zs deliaPsan lull' �o 14 No,�k,��O aPqll to of PU d center To*'. and z 0 �Weoe ,S,,ggef e Sheet toleckCeq . so eqllam'Pace je.qtde W?Cal) 0\o-otop jo\)( ? o.1, el ?00W Ai\ 16- 50 de 0 yo -0 ea V ire \0- 44! \00 & ONEMOletc. #15 Maximum Design Pressure=-52.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #16 Maximum Design Pressure=-60 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #17 Maximum Design Pressure=-60 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip with CMG Flat Bottom Metal Plates Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #18 Maximum Design Pressure=-67.5 psf: Deck: Min.15/32-inch plywood'to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underlayment) Fasteners: 12 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at four(4)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch-applied or Polyflex G, torch- applied. #19 Maximum Design Pressure=-75 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underlayment) Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with CMG 3"Galvalume Steel Plates, OMG Roofgrip#14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 10-inch o.c.at the 4-inch wide side laps and 10-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch-applied or Polyflex G, torch- applied. #20 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #21 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or CMG Flat Bottom Metal Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #22 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. NEMO ETC,LLC. Evaluation Report P12060.02.09-R24 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 9 of 14 ONEMOJetc' . #23 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underlayment) Fasteners: Dekfast#14 with Dekfast Hex plates, OMG#14 HD with OMG 3"Galvalume Steel Plates, OMG Roofgrip#14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch-applied or Polyflex G, torch- applied. #24 Maximum Design Pressure=-97.5 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c.at the 4-inch wide side laps and 4-inch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #25 Maximum Design Pressure=-105 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #26 Maximum Design Pressure=-112.5 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer at all tin-caps Base Ply: Polystick MTS or Polystick MTS PLUS,self-adhered Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max, Polyflex SAP,Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #27 Maximum Design Pressure=-120 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #28 Maximum Design Pressure=-120 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. 5.6.4.1 All other direct-deck, adhered Polyglass underlayment systems beneath foam-on tile systems carry a Maximum Design Pressure of-45 psf. NEMO ETC,LLC. Evaluation Report P12060.02.09-R24 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 10 of 14 ONEMOjetc. 5.6.4.2 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016)for Zone 2/3 enhancements. 5.7 Exposure Limitations: Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days after installation. Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation. Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Dual Pro,Tile Pro or Elastoflex G TU shall not be left exposed for longer than 180-days after installation. Polyflex SAP or SAP FR, or Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive-set tile, in which case the maximum exposure is 30 days. Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the prepared roof covering is to be adhesive-set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum exposure is 180 days. 5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition,tested at standard laboratory conditions. Agreement between purchaser and seller,as set forth in Section 4.3, Note 1 of ASTM D1970-15,should be established as to slip resistance. 5.9 Tile Slippage Limitations(FRSA/TRI April 2012(04-12)): When loading roof tiles on the underlayment in direct-deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Flat 10-tile stack 7:12 Elastoflex G TU Lugged 8-tile stack(6 over 2) 6:12 Elastoflex S6 G or S6 G FR Flat or Lugged 6-tile stack(4 over 2) 4:12 Polystick MTS or MTS PLUS Flat 6-tile stack(4 over 2) 5:12 Lugged 6-tile stack(4 over 2) 4:12 Polystick Tile Pro Flat or Lugged 6-tile stack(4 over 2) 7:12 Flat 6-tile stack(4 over 2)or 10-tile stack 7:12 Polystick TU Max Lugged 6-tile stack(4 over 2) 7:12 Lugged 10-tile stack 6:12 Polystick TU P Flat 6-tile stack(4 over 2) 6:12 Lugged 6-tile stack(4 over 2) 4:12 Rolystick TU Plus Flat or Lugged 6-tile stack(4 over 2) 7:12 Flat or Lugged 10-tile stack 6:12 Polyflex G or G FR Flat or Lugged 6-tile stack(4 over 2) 4:12 Polyflex SA P or SA P FR Flat or Lugged 6-tile stack(4 over 2) 4:12 NEMO ETC,LLC. Evaluation Report P12060.02.09-R24 Certificate ofAuthorizotion#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-1128 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 11 of 14 , ONEMOletc. 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6.3 Elastobase,Elastobase P or Mule-Hide Nail Base: 6.3.1 Non-Tile Applications: Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. Elastobase, Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA P FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self-adhered, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR,torch applied. Roof cover limitations are those are those associated with the top-layer underlayment,as set forth in Table 1. 6.3.2 Tile Applications: Elastobase,Elastobase P or Mule-Hide Nail Base are limited to use as a mechanically attached base sheet in the"Two Ply System"from FRSA/TRI April 2012(04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with FRSA/TRI April 2012(04-12)Installation Manual. 6.4 Polystick MTS,MTS PLUS,IR-Xe,TU P,TU Plus,TU Max,Dual Pro,Tile Pro or MU-X or Polyflex SAP,Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR): 6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970(except Polystick TU P) underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.4.2 Direct-to-Deck with Mechanically Fastened Roof Covers: All self-adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR)should be back-nailed in selvage edge seam in accordance with Polyglass/Mule- Hide back nailing guidelines. Nails shall be corrosion resistant, 11 gauge ring-shank type with a minimum 1-inch diameter metal disk or Simplex-type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back- nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The head lap membrane is to cover the area being back-nailed. All seal-lap seams (selvage laps) must be firmly rolled with a minimum 28 Ib. hand :' roller to ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). ` a,E i View of Ovelap Seam of Dual Pro and Tile Pro All over-fabric and over-granule end-laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap. Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets,exposed valleys, or exposed roof to wall details NEMO ETC,LLC. Evaluation Report P12060.02.09-R24 Certificate of Authorization 1132455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 12 of 14 f ONEMOletc. Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be installed in a water shedding manner. All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-Ib weighted-roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches, laps(min.28 Ib roller)or small areas of the roof that are not accessible to a large roller or broom. 6.4.3 Tile Applications(not allowed for Polystick Dual Pro,IR-Xe or Polystick MU-X): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self-adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRI April 2012(04-12),Table 1. For adhesive-set tile applications, refer to Section 5.6.4 herein. 6.4.4 Two(2) Ply Underlayment Systems: Polystick MTS or MTS PLUS followed by Polystick MTS, MTS PLUS,TU P,TU Plus,TU Max,Tile Pro, MU-X or Polyflex SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top-layer material. This is not a requirement,but is allowable if a 2-ply underlayment system is desired. Polystick MTS or MTS PLUS followed by Polystick TU P,TU Plus,TU Max,Tile Pro or Polyflex SAP is allowable for use under foam-on tile systems. Limits of use are those associated with the top-layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. 6.5 Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR: 6.5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System"from FRSA/TRI April 2012(04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet" in the"Two Ply System"from FRSA/TRI April 2012(04-12) beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet"in the"Two Ply System"from FRSA/TRI April 2012(04-12) beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G FR is for use as an alternate to"Mineral Surface Roll Roofing" (ASTM D6380,Class M)in the"Single Ply System"from FRSA/TRI April 2012(04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet"in the"Two Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof systems. 6.5.2 For hot-asphalt-applications, Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt-applied to the substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end-laps minimum 6-inch wide, off-set minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 6.6 Polyflex G or Polyflex G FR: 6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Polyflex G is for use as an alternate to the Heat Applied"Cap Sheet" in the"Two Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened or adhered tile roof systems(Base Sheet Limited per 5.6.3). ✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof systems(Base Sheet Limited per 5.6.3). MEMO ETC,I.I.C. Evaluation Report P12060.02.09-R24 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 13 of 14 NNEMO etc. 6.6.2 Polyflex G or Polyflex G FR shall be fully torch-applied to the substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end-laps minimum 6-inch wide, off-set minimum 3 feet from course to course. Side and end laps shall be fully heat-welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. 6.7 Tile Staging: 6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein,and Polyglass published requirements for tile staging. 6.7.2 Battens and/or Counter-battens, as required by the tile manufacturer and FRSA/TRI April 2012(04-12) must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail- boards,to prevent tile sliding and/or damage to the underlayment during the loading process. 6.7.3 Polyglass specifies the minimum cure time after installation of self-adhering membranes and before loading of roofing tiles is forty-eight(48)hours. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C.61G20-3 QA requirements. The following plants have qualified products under their respective physical properties specifications. Plant Specification ProductUs Fernley,NV,Hazleton,PA&Winter Haven,FL ASTM D1970 Polystick MU-X Hazleton,PA M-D 13-0004 Elastoflex G TU ASTM D1970 Polystick IR-Xe Hazleton,PA&Winter Haven,FL ASTM D1970&FRSA/TRI April 2012 Polystick TU Plus ASTM D1970&FRSA/TRI April 2012 Polystick TU Max Tuscaloosa,AL ASTM D4601,Type II Polyglass G2 Base ASTM D226(physicals) Elastobase,Elastobase P ASTM D6509 Polyglass APP Base FRSA/TRI April 2012 Polystick MTS,Polystick MTS PLUS FRSA/TRI April 2012 Polystick TU P Winter Haven,FL FRSA/TRI April 2012 Polyflex SAP,Polyflex SA P FR ASTM D1970 Polystick Dual Pro ASTM D1970&FRSA/TRI April 2012 Polystick Tile Pro ASTM D6164 Elastoflex S6,Elastoflex S6 G FR ASTM D6222 Polyflex G,Polyflex G FR 9. QUALITY ASSURANCE ENTITY: UL, LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com -END OF EVALUATION REPORT- NEMO ETC,LLC. Evaluation Report P12060.02.09-1124 Certificate of Authorization#32455 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 14 of 14 l i NNEMOletc. 5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012(04-12) and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04- 12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads. #1 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment: Polystick TU P,Polystick TU Plus, Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #2 Maximum Design Pressure=-97.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG 100 or ASTM D41 Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1%"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. #3 Maximum Design Pressure=-105 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB-3000 Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1%"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. #4 Maximum Design Pressure=-135 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Joints: Min.4-inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #5 Maximum Design Pressure=-315 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max,Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #6 Maximum Design Pressure=-622.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #7 Maximum Design Pressure=-30.0 psf*: Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max, Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. NEMO ETC,I.I.C. Evaluation Report P12060.02.09-R24 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 7 of 14 11 . 1 ONEMOletc. #8 Maximum Design Pressure=-37.5 psf*: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #9 Maximum Design Pressure=-37.5 psf*: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One(1)or two(2)layers ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. #10 Maximum Design Pressure=-45 psf*: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One(1)layer ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c.at the 2-inch wide side laps and 4-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G TU,applied in full mopping of hot asphalt. #11 Maximum Design Pressure=-45 psf*: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Two(2)layers ASTM D226,Type 11 felt Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 9-inch o.c.at the 2-inch wide side laps and 9-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. #12 Maximum Design Pressure=-45 psf: _ Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.at the 2-inch wide side laps and 18-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #13 Maximum Design Pressure=-52.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #14 Maximum Design Pressure=-52.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max, Polyflex SAP,Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-AP,0 Cap Sheet(FR),self-adhered. NEW ETC,LLC. Evaluation Report P12060.02.09-R24 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 8 of 14