Owner: VERA&TOM ASTER Wind Zone: 170 MPH.
Address: 121 QUEEN EUGENIA COURT Exposure Category: C ,I
HUTCHINSON ISLAND,FL 34949 Minimum Building Dimension: 25 ft. II
Mean Roof Height: 25 ft. ii
Risk Category: II ,I
iI
Design Pressure Calculations ll
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure/(psf)
1 Int 24.25 47.50 7 42.1 -451f7
2 Int 49.50 47.50 7 40.7 -44L3
3 Int ' 24.25 47.50 7 42.1 -45;,'7
4 Int 34 35.25 7 42.1 -45:7