Loading...
HomeMy WebLinkAboutProduct Approval-Sgl Hung Window , 6/5/2018 Florida Building Code Online 1 �IIC°s� r t. �;(. ( Ch`s ;y ° } ° P'J1. 11 )iy � ,t}+11SA9r �t� I '� _oj 1 I Vt> xM .ABOcrnR 0 PRD1616101a co)fAero*PR BCIS Home I Log In I User Registration I Hot Tapia I Submit Surcharge I Stats&Facts I Publications i FBC Staff I BCIS Site Map I Links I Search d bpr a +, J1 Product Approval USER:Public User er ' L r51 0 u, '.i:�C1'r Rr: , I ) Product Approval Menu>Product or Aopllcation Search>Application List �1 1 ^C?l e Ours W Search Criteria Refine Search NC W 50 V4 h Code Version 2017 FL# 16851.6 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL • Product Model,Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL!! Impact Resistant ALL Design Pressure ALL Other ALL Search Results-Ap Iications ELA Iype Manufacturer Validated By. Status FL16851- Revision NewSouth Window Solutions Ryan J.King, Approved g(z FL#:FL16851.6 P.E. History Model:f.9450 Single Hung Window Impact Rated-HVHZ (813)767- Description:Extruded Vinyl"Impact"Single Hung Tilt Window with Flange 6555 (O/X-configuration) Category:Windows Subcategory:Single Hung I 'Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission If necessary. I I Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida,::privacy Statement::Accessibility Statement::pefund Statement Under Florida law,email addresses are public records.If you do not want your a-mall address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with en email address if they have one.The emails provided may be used for affidai communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click Product Approval Accepts: I rEl F-33 ® dha: Credit Card Safe secu rityM irrittcs O op„ o I Pet /No. ?Q, St• h9 B 4°9,0 4c/QOeIO Cptoo, 8nt https://www.floridabuilding.org/pdpr_app_Islaspx 1/1 6/5/2018 Florida Building Code Online iPi 4. }1. iFtiI encotioar I.B6UTImBPR O PPtlJVIeiD 8 -Cb$TAGTbBPa BCIS Home i Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts I Publications I FBC Staff I BCIS Site Map I Links I Search Florida it_; si ProductliApproval USER:Pubc User PrngUct Approval Menu>ProqucS or Application SCarCtl>Application List>Application Detail !;:f arm e Zi FL# FL16851-R6 I Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer NewSouth Window Solutions Address/Phone/Email 4901 oak fair blvd tampa,FL 33610 (513)284-0129 danochstein@newsouthwindow.com Authorized Signature Vivian Wright rickw@rwbIdgconsultants.com • Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F.Schmidt the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan J.King,P.E. ' Validation Checklist-Hardcopy Received Certificate of Independence FL16851 R6 CO1 (c)Certificate of Independence,pdf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA101/I.S.2/A440 2011 AAMA/WDMA/CSA101/I.S.2/A440 2008 ASTM E1886 2005 ASTM E1996 2006 ASTM E1996 2009 TAS 201,202,203 1994 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/pr.app_dtl.aspx7param=wGEVXQwtDgtmmTSTNdVPsacfoLiCDIJOLdCTtJwrC1%2fiaHWx7bLvlw%3d%3d I 1/5 6/512018 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 02/08/2018 Date Validated , 02/08/2018 Date Pending FBC Approval 02/14/2018 Date Approved 04/10/2018 Summary of:Products Go to Page 0 0 Page 1/2 0 0 FL* Model,Number or Name Description 16851.1 a.9400 Single Hung Window Extruded Vinyl"Non-Impact"Single Hung Tilt Window New Construction with Nail Fin(O/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R6 Ii (b)Jnst 16851.13/Si( Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.1 for Design Pressure Ratings,any FL16851 R6 AE (b) Eval 16851,1,pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.2 b.9400 Single Hung Window Extruded Vinyl"Non-Impact"Single Hung Tilt Window with Flange(O/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R6 II (b)Inst 16851.2.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.2 for Design Pressure Ratings,any FL16851 R6 AE (b) Eval 16851.2,pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. I , 16851.3 c.9450 Single Hung Window Extruded Vinyl"Impact"Single Hung Tilt Window New l Construction with Nail Fin(O/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R6 II (g)Inst 16851.3.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.3 for Design Pressure Ratings,any FL16851 R6 AE (b)Eval 16851,3,pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.4 d.9450 Single Hung Window Extruded Vinyl"Impact"Single Hung Tilt Window with Flange (O/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R6 H (b)Inst 16851,4.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.4 for Design Pressure Ratings,any FL16851 R6 AE (b)Eval 16851.4.pdf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 16851.5 , e.9450 Single Hung Window Impact Extruded Vinyl"Impact"Single Hung Tilt Window New Rated-HVHZ Construction with Nail Fin(O/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16851 R6 II (b)Inst 16851,5,pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.5 for Design Pressure Ratings,any FL16851 R6 AE (b) Eval 16851.5,pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.6 f.9450 Single Hung Window Impact Extruded Vinyl"Impact"Single Hung Tilt Window with Flange Rated-HVHZ (O/X-configuration) Limits of Use Installation Instructions https://www.floridabuiiding.org/pr/pr'app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsacfoLiCDIJOLdCTtJwrC1%2fiaHWx7bLvl w%3d%3d 2/5 6/5/2018 Florida Building Code Online Approved for use In HVHZ:Yes FL16851 R6 II (b)Inst 16851.6,0 1 Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.6 for Design Pressure Ratings,any FL16851 R6 AE (b) Eval 16851,6,pdf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 16851.7 g.4400 Single Hung Window Extruded Vinyl"Non-Impact"Single Hung Window New I Construction with Nail Fin(O/X-configuration) Limits of Use Installation Instructions Approved for use In HVHZ:No FL16851 R6 II (b)Inst 16851.7.g_df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.7 for Design Pressure Ratings,any FL16851 R6 AE (b)Eval 16851.7.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. Flange 16851.8 h.4400 Single Hung Window Extruded Vinyl"Non-Impact"Single Hung Window with i lange (0/X.-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R6 II (d)Inst 16851.8,psi( Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.8 for Design Pressure Ratings,any FL16851 R6 AE (d) Eval 16851.8.01 additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.9 I.4450 Single Hung Window Extruded Vinyl"Impact"Single Hung Window New Construction with Nail Fin(O/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R6 II (d)Inst 16851,9,odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.9 for Design Pressure Ratings,any FL16851 R6 AE (d) Eval 16851.9,pd( additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.10 j.4450 Single Hung Window Extruded Vinyl"Impact"Single Hung Window with Flange(O/X -configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R6 II CO Inst 16851.10,pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.10 for Design Pressure Ratings,any FL16851 R6 AE (d)Eval 16851.10.0f additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.11 k.4450 Single Hung Window Impact)Extruded Vinyl"Impact"Single Hung Window New Rated-HVHZ Construction with Nail Fin(0/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16851 R6 II (b)Inst 16851.11.p1f Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.11 for Design Pressure Ratings,any FL16851 R6 AE (b) Eval 16851.11.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.12 1.4450 Single Hung Window Impact Extruded Vinyl"Impact"Single Hung Window with Flajlge(0/X Rated-HVHZ -configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16851 R6 II (b)Inst 16851,12.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.12 for Design Pressure Ratings,any FL16851 R6 AE (b) Eval 16851.12.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars' 16851.13 m.4000 Twin Single Hung Window Extruded Vinyl"Non-Impact"Twin Integral Mulled Cornmon Jamb Single Hung Window New Construction with Nall Fin(O/X I O/X-configuration) https://www.tloridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsacfoLiCDIJOLdCTtJwrC1%2fiaHWx7bLvlw%3d%3d 3/5 6/5/2018 Florida Building Code Online Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R6 II (b)Inst 16851.13.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.13 for Design Pressure Ratings,any FL16851 R6 AE (b)Eval 16851.13.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.14 n.4000 Twin Single Hung Window Extruded Vinyl"Non-Impact"Twin Integral Mulled Common Iamb Single Hung Window with Flange(O/X I O/X- configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R6 II (¢)Inst 16851.14.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 16851.14 for Design Pressure Ratings,any FL16851 R6 AE (b) Eval 16851.14.odf additional use limitations,Installation Instructions and product Created by Independent Third Party:Yes particulars. 16851.15 o.4000 Triple Single Hung Window Extruded Vinyl"Non-Impact"Triple Integral Mulled Common Iamb Single Hung Window New Construction with Nail Fin(O/X I O/X I O/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R6 II (b)Inst 16851.15.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.15 for Design Pressure Ratings,any FL1685I R6 AE (b) Eval 16851,15.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. I 16851.16 p.4600 Twin Mulled Single Hung/ Extruded Vinyl"Non-Impact"Twin Integral Mulled Common Picture Window Iamb Single Hung/Picture Window New Construction with Nall Fin(O/X I 0-configuration) ----- Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R6 II (b) Inst 16851.16,pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.16 for Design Pressure Ratings,any fL16851 R6 AE (b)Eval 16851.16,pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.17 q.4600 Twin Mulled Single Hung/ Extruded Vinyl"Non-Impact"Twin Integral Mulled Common Picture Window Iamb Single Hung/Picture Window with Flange(O/X I 0- configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R6 II (b)Inst 16851.17.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.17 for Design Pressure Ratings,any fL16851 R6 AE (b) Eval I6851.17.pdf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 16851.18 r.4800 SH/SH/SH-Triple Single Extruded Vinyl Integrally Mulled Triple Single Hung Windows Hung with Flange; (O/X I 0/X I O/X configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R6 II (b)Inst 16851.18.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.18 for Design Pressure Ratings,any FL16851 R6 AE (b) Eval 16851,18.pdf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars: 16851.19 s.4900 SH/SH-Twin Single Hung Extruded Vinyl Integrally Mulled Turin Single Hung Windows _ with Flange; (0/X I O/X configuration) —_— Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R6 II (d)Inst 16851,19.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.19 for Design Pressure Ratings,any FL16851 R6 AE (d) Eval 16851,19.pdf Created by Independent Third Party:Yes https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsacfoLiCDIJOLdCTtJwrC1%2fiaHWx7bLvlw%3d%3d 4/E 615/2018 Florida Building Code Online additional use limitations,installation Instructions and product particulars. II J 16851.20 t.4900 SH/SH/SH-Triple Single Extruded Vinyl Integrally Mulled Triple Single Hung Windows Hung with Flange; (O/X I O/X I 0/X configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R6 II (d) Inst 16851,20.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.20 for Design Pressure Ratings,any FL16851 R6 AE (d)Eval 16851.20,pdL additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. Go to Page 0 0 Page 1/2 IS IP WIES Contact Us::j601(lair Stone Road,Tallahassee FL 32399 phone:850-487-1824 i The State of Florida Is an WEED employer. yflpj,t 2007-2013 State of Florida,::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your a-mall address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395..Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The malls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter`455,F.S., please click IISEL. Product Approval Accepts: EM RE El EME cam Credit Card Safe securityMrTRIcs httpsJ/www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsacfoLiCDIJOLdCTtJwrCl a/o2fiaHWx7bLvl w%3d%3d 5/E \`,`,,..1*.V I SII., 4..,................ ,„ .,.,, .,,„ ewsoutENh r 55"MAX OVERALL RANGE WIDTH °_ 54'MAX OVERALL FRAME WIDTH A z � ' aurn WINDOW SOLUTIONS 1 ......................,�II _ I ..rr Hr11V'v o R o z 4901 Oak Fair Blvd.,Tampa,FL 33610 / R g E Z m. 9 cW /,/ 1 @ akE n 9450 Single HungWindow 0 M 8 a I0 / 9 4 IMPACT RATED - HVHZm /// o 6Z F. w/Flange ' g / Z QC7 GENERAL NOTES ^ / R �/ a 1. This product hos been evaluated and b in compliance with the 6th Edition /� El & (2017)Florida Building Code(FBCI.Including the"High Velocity Hurricane / 6 Zone"(HVHZI. /// 'E E ag E 2. Product anchors shall be as listed and spaced as shown on details.Anchor / F $ Aembedment to base material shat be beyond wail dressing or stucco. -_w�QF v --, yN V N 5 3. When used in the"HVHZ",this product complies with Section 1626 of the Florida •c-. V7 5 Building Code and does not require an impact resistant covering. W z. 8 . �16t - t 4. For 2x stud framing construction,anchoring of these units shall be the same as o^ 3 e that shown for 2x buck masonry construction. ).- w s 5. Site conditions that deviate from the details of this drawing require further T3000 1 engineering analysis by a licensed engineer or registered architect. '``0 0 r --.,c..,--..... ^,Dhh Q D ^.N,01—W W MAX OVERALL MAX.OVERALL MAX MAX. .. DESIGN PRESSURE ._o moa a TABLE OF CONiENTS DAY.NTE DAY UT! MASS Z SHEEN DESCRIPTION FLANGE FRAME DIMENSION DIMENSION rs Rz SO n a' a— u DIMENSION. DIMENSION (Ot'ERASW (FIXED) loll NEG:: '. ne 2/I9/14 G 1 1 Typical elevations,design pressures&general notes 1 2 Vertical&horizontal cross sections 55.0"X 77.0" UV X 76.1' 4725x34.35 49.75 x 34.5 GT,G2 +55.0 -65.0 N.T.S.ey: 3 3 Vertical&horizontal cross sectionsrmom err 4 Buck&frame anchoring 3 X 63.0" 37.r X 62. 30.25"z 27.36" 3275x 27.6" Gl.G2 +65.0 -85.0natrickmosacIFS 5.1 1' a ! 5 Components ° 6 8,11 of materials and glazing detaihF1n Note:This product,when used with GI gloving,Is not approved for use alcove 30 feet In the"HVHZ'. —16851.6 s 1 or e b ¢r a ' 1 - I ..osTa tit NOTE Sheet Med Screws musl ./......'..... % 1 !-.- -_-___ - ex perietmio a mh.of 3 treats a.. .,. A . .7: t 47 through at leas,2 shoob of metal. 0 . ..• A • i ity -• • 1 0 0 s de 1 it ire n . Ali 11 AA 0 . 0----P- IIIIWili1 -•:-.:"It,-.)\,.. -, , %I 0 *--. -4w111111 sg. • wjp, li .11 INTERIOR /4, i i 1 In ‘‘‘ I 4 o " ri / II Ilisnr, 0 Elg ,..-.-k- 8gi ifirolit.,7_4=- 4=7",,rv=is fL.,..___„--------- T- 1,---- „iiiir co 0 & .. .i.-- -. - -mr.-.1.-T1 (VA j ,i, ill / II g'1'.111H---- •- • I \II!! 1;111 ... [---.........., 1:11.1111- .1 X • i --7,-_-_-_L, ji ------ (ID 1 til ______ _ 0 Cie. EMIR CO I, ilNit.:_e" estecnEi g ____________, . . Ia Not= Y WINS:MAL CROSSETIN ED INTERIOR 1 I.Lodc=I keeper localod T from '•:114.1-11r.,,1 16.0Laii each and of lockfmeethp rd. 0 • 0 ' "1410 0 111 DUERIoR i • 4gEksgt 1-1/MR 0 OM MO.RP.) 0 0 0 gc 1 0 " %7 o00 0 - • . ill i INIERIOR 0 0 ,.,„ ... ° 0 i . • 1 c 0 0 0 to c . _._,.....,. -,1 ohl6 1 es EZ-7.7.__ c I . .. 0 le 114 E c.1 V ri z w • ire , -, • R..,1,ii I R i fit----,417:7*----1=._ - -1---c.7.7y. iit ,, . .... . _No in 0 (3 Laiilmr 011•4 -j '.74/17E--j• pi r 1 . A 1,,...ri. iii:1-- 0 ,r," _.-_-_-. -ii.ii 151kg I 1 I us. , ! 5 - 4.--1 ciji ail. .— -....1-____—_,..11 , r illibib._-• I I,- 0 pr......0 gidl° j111% 43:gt 7li 1111111111111 8.`'Fip-•44A-Ws 1 i = "vi illrirli 0 Ad 1—.... .-.a__-,M1IL— _ .. .•. • :,. . • saoci.1ew11a.w.IN.N.T..a.S4. V S1-W1/4oMw0 0 EXTEIOR K4 yMAL CDMoKnacnSm2t/Pa19.%LJFK1S4 0 WITE=CMu0 orMONFALCROSSSEC1701C( _ _ 1* CROSSearstacri -- --- --- - - FL-16851.6 i .40,011.1:1111, 4, woe Sheet Me1aISaaws mot . .. dr%penetrate o mln.al 3 treads 1.. 2 i 1 ill 0 gar Oomph at least 2;heels of meal. 0 .-• .. ig / [ Aii ill ] M %IP ., 11-147- iliMill Iv -- 11 VP' w moat 0 II h. • - IL' 11 , 1; 11111111==—ei 7-1'74 mod-I.7ar.--... ENANN 4 li iiiS - IR Jw-Ein Ai kia•_ii_mtg, 0 0 1 gil 1; A 1 1 ol L_ LL'ILLA-:---- • 1 \ v.zi.: , e i a Ita-sao ,)w_iimo 1111 co , dX ...••••-•••••-••-•-.---.•--'-...-i.4• AI, ffitLlI iii 0 0 i •••./g ,., 0 00,,.-10R ea' I III lilt--'6. „ W 0 SEE NOR 1 6 i 11 g I —7=7-77=•: --•; --,.1.-;',.^ri 0 1 41 0 W aoss SECTION :1111% -.i 1 r7-11_ New Irk 111, 14... ill III 1.Look and boom boatel T from 4.14 5...- •1 A , INER/OR I Goal end of locicimaellng rat 0 .L.-11 1.,:.. I I o ±55 PS F CGERIOR 15gpg1 t I-11f WA EMI.11YR1MAX.DESIGN FEMME FOR ALTERNATE ANCHORING LOC.A1100194OWN ONIESSHEET 0 0 - 0 0 frfP1 E x e I " FOR FRAME MORI>ar OR FRAME 1.03oNT s lei 0 „, OCD 0 we - gag i . . A. imam o 0 0 • , ...k.a. g.: 1 v 0 10 o o tc ..0 — (le 0 gilge S to51 5 ', ---g -..__._,.,,,i . . • 031H..-111:ti711._Jill-0000 R414R P 0 ,T€T.WeaiiTEW ..,1*--,-- ,,ONHIINM ........... =KAI I. I. 1.11 I rillW 0 ^r fg. w tow MO 1 :—.1;111-1MIN, 1 lf 1 - P 0 n111111 II .7...-e_ I .7 05 .t.tniona *''.'•"1.;:1 g..,:. .-VA 1 1 .. • -•A .../ ' lir ' MI 0 111.1L"..." 0 aril IP' •A' ..P . • • 0 . e' . • !. . • 4 • • ,...N..iiria t • rs.1,1 Iv 2 oat, 2/19/14 . I .. 0 0 00 . 0 0 I-11e Ai1.1 EMIL(11,4 Imp N.7'.S. ma.on US X 1 0 0 NORIZONTAL CgcoOrl ZIP014 0 rionfotirm mionsiciloN 021eAmLnylialscr=4 Ditvom Mt R V FL-.181351.6 E, 71(Buck Mason'y 1X Buck Mammy -..- 611M,3_el r_IL 0 - — - - - _ i . MalianVim Death Windows FIAAANENDA-flakto Ptcduct Approdalia-15351 Smolt iturOt-OnmingsV116851.(2017141-16851.6.thaa 4-a fa la I I 11 11;11::,1 Oil! -'... " gi g i g . • i el • ...;IT. 11..1 .. , 11 g g Iti:Iffig I 1.1 I wi .. iii 11112. . . ..i .... •.%•.;11..„) ..)- 4:".f'' .0 $eGI 1 • ...1 -..,...1 I I 1 • : LA.4.—..‘ %g ..... .• e -•.. ••! ai - iiii 142 4 , . -k••• 1 :. !,,,,, if g ,a.. 1 0 —... .•. '1 Pi lit III 1 • •3;) A.:: p .1% I Nst Ss 1 1 e A rh A 2 g li 1 le I 1 ft 1 i 4 7 1 1 1 I I_ .4' _..I 1:f I Iryper .— I. .1 n OM 01 1 1 11 y2g P ri w, 1 ••. '• •. "' • -- -----I 1•. mooe _ 1I 1 . -0 i 7` 0 . •: i‘ .. 1 1 ; w 1 ) 14.1-1 1-7-1.1 ifirprd ,L._ E 1 1 ..........wit44 ?.. •=lci * likE , Ociaber12,2017 1.-. j i , PRODUCT: Dosumunts mimed ....:t ......1410/ 4.7. 1 piPlgi a , 08 $7 ::.• TE T17 6TH ED. (201n FOC .PC SINGLE HUNG WINDOW reap!. Eichntiel. ! ' ' .3742 WINDOW STZE IFS 60 In. 1 14, I 3 1 • \ : g II:ID:ALT MOM Locop LFS "111111100- 2 14715,foo magic cum_ .DT -PART OR AMMO': -gew.mama CONSULTANTS. IMO. P.O. Box 230.Witco. Pk 338os /15 UPDATE TO 5TH 20. (2014) FOC,IFS IBUCK 1 FRAME Phone Kat 1113.080.91D7 Th 6 .." NO DATE BY ANCHORING MD O.A. No. 91,113 AEI/SONS" 0 9014 ol.v.rall1LOINal Copasumarro Imo. ' . . , i mcFintsvera kWh*Won Pothwdarm-name fird..0A5Fn7.4158,15332558.•)4101K-5,566,55FIAGINI(2017811•151n5454 5-2 229' • i i r;= L =3 , C1.062' — i 43 cri[11:1G=EJEJ I 11 Da , 219- . .- 2.74" 1.20 1L .--. v7.,; 0 A‘,..• 1 ....V>, 4 -1-- ' ' q 111111 P 1 1 - I 1 CI 1 %A :4 cf.:: q • it *3 ::•:•:'. •::: 1 .1:`,Zf•: :Z 1 . 1. 1.41. i___I.2e__Ig 1.70' _, I III._ T I LP Fl---1 11 1.24" 1 ---1- '>S''' , :`• 0 ,: ,. . ',. b. :',..-.•. P •:.::':. -1 51 —T —1 cue 4 i47C) 1_rii 1-.-021* I- i 7:1 EJ r::- = 8 1.1. (Erfl 1 1 L I 1 4' L.UFq 4. 1 r _i [. 1.47'---•-• ' lir out 111/010 if 4 I r._=. i il L I' i , oolattice., .e.- a I No.43400 i f.- oda*1Z 20/7 Demo.onts`517.5avd 01,1 1. ,......ur s 1?LIPOME TO 877.1 Eif. (2077)MC JK Pilt5-2--.4iCitsthaz Km mew kridon F. Schenk* I 1," 139-.004.- . 1 2 2 ,,,, 4 TV;7 Aram 37x52 811430N Ma 1.F3 P.E. No.43409 4.4 3 9 7116,/.90E9 AM ANCTIOR LOCATION (FS ...i• Z.4 2 I 17418 ADO(AMMO DETNI. 0 PART OR ASSDM : IELY: g ift in ..7 1 6 15 timer m 5U4 ED. (2014)MC liS *W.MELDIP.O. WI W413XMIT32.10 VattlCC.LIIII1 330511113: 1 NO.' 87 COUPONENTS mom No. 613.000.0107 _ REVISIONS FPC O.A. No.5813 0 251-4 N.W.Mult.cm el croasuvro.wra Dm . , 4tn!naVYr SOWi Widows dews RIMIANDANA-Florid'PratlKt Ayprcred1 -16951 SI*MAW-Dn.4va-181s1(2G17niL-76as1Edo3 62 IMa/3E.1 30o.6",,N_,0'ci os vo.tnA Ca Na--“–"...=0"n lm 00011 . •"' glE112111111BiltilligninVil Iillillii 8!gi!I4A:Illi! BiPIiill A gm„4.111 i Z. R Fi' j N i gg I '81 Ilid . 18 10 , EX 9, . , all . 41FF §§111§§ z� ; gg �El o�g MIMM8M 8 l IEl] R = 1 n CoQ �i i ! II � coq m �IJdli, ;a 8 iii ! 1191 LA la1 4 rat 1i . ilq 0 g . 1 61 I, , , 1 P 1 I is 98 0 ,,,,,«111111,,,,' 34°.111/ ti...; ^*i j 144.43408 :** : omCVr Tz 2oI7 - ' J s 4 1'RD000Ti ammo&Pr.f•.a in•:,. ��— •'. 1 p 1.0 lig S UPDATE TO 51M D. (2017) FBC a SINGLE NUNG WINDOW Loom F. Il OmOd1 I ";'�, , .. ..:,-^''` "or- 1 9 3 to 4 AU 17 ADDED 37162 WOW Si7E LIS P.C. Na O4DB ¢,,.. .0 3 9 7 16 ADDED ALT.AH LOCAT1 OS g11/11111N��� GI y :F 2,t 17 13 ADD C1AZ1ND DEM X -Par at Ass704r. G/j ammo C TA1rn. INC. 5` co.-4. 1,8 '•. 13,UPDATE 1D STH ED. (20)4) FBC 115wow 1y(/P.O. Dmf .io.%%Woo. P1.33698 �' # �� — MASONS ANO GLAZING Mono No.:s. 8819AIn Fit C.A.No. 0819 0 101•FI.W.wawa:,aa.rnn7Mrf•um, R W BuildingConsultants, Inc. R Consulting and Engineering Services for the Building Industry B P.O.Box 230 Valrico.FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No.9813 Product Evaluation Report Report No.: FL-16851.6 Date: October 12,2017 Product Sub Category Manufacturer Product Name Category NowSouth Window Solutions 9460 Single Hung Window Windows Single Hung 4901 Oak Fair Blvd Impact Rated-HVHZ Tampa,FL 33610 WI Flange (813)626.6000 Scope: Product Evaluation report issued by R W Building Consultants,Inc.&Lyndon F.Schmidt,P.E.(System ID#1998)for NewSouth Window Solutions,based on Rule Chapter No.61 G20-3,Method 1D of the State of Florida Product Approval, Dept.of Business&Professional Regulation. RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code(FBC)including the"High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the"HVHZ",this product complies with Section 1626 of the FBC and does not require an impact resistant covering. 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-16851.6 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL-16851.6 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Sinned by C9937.03-401-18 TAS 201,202,203-94 Architectural Testing,Inc. Shawn G.Collins,P.E. TEL 02031487 TAS 201,202,203-94 Testing Evaluation Lab. William B.Shelton,P.E. TEL 02031566 TAS 201,202,203-94 Testing Evaluation Lab. William B.Shelton,P.E. TEL 02031722 TAS 201,202,203-94 Testing Evaluation Lab. William B.Shelton,P.E. 2. Miami Dade NOA Materials Testing 17-0712.05 Saflex°PVB Interlayer(Eastman Chemical Co.) 3. Drawing No. Prepared by Signed&Sealed by No.FL-16851.6 RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. 4. Calculations Prepared by Signed&Sealed by Anchoring RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. ASTM E1300 Glass Load Lyndon F.Schmidt,P.E. %cotIlitriggt, 0�0�F,SCHfl••//r. 5. Quality Assurance a� ,,.•';G` - .' ,�4:9 Certificate of Participation issued by National Accreditation and Management ®o,� \, F••. ®vo Institute,certifying that NewSouth Window Solutions is manufacturing No 09 products within a quality assurance program that complies with ISO/IEC . h 17020 and Guide 53. d • t \ STATE 0 4," 4‘.•. d e4f# ,ua O.... mow Lyndon F.Schmidt,P E. ,B#,, 9 6/0 NO ir54`NAL 0 FL •PE1 o.43409 Sheet 1 of 1