Loading...
HomeMy WebLinkAboutBuilding Permit ApplicationALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: Permit Number: e Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential x PERMIT APPLICATION FOR: To Select from dropbox, click arrow at the end of line PROPOSED IMPROVEMENT LOCATION: Address: 744 E Prima Vista Lane Port Saint Lucie Florida 34952 Legal Description: Install RINNAI Natural Gas Unit Property Tax ID #: 3419-575-0010-000-5 Site Plan Name: Project Name: Setbacks Front Back: DETAILED DESCRIPTION OF WORK: Install RINNAI Natural Gas Unit Right Side: Left Side: Lot No. Block No. CONSTRUCTION INFORMATION: CONTRACTOR: A Name: Manuel Duran Additional work to be nertormed under HVAC L_I Gas Tank this permit-- checl 0Gas Piping all appy:. Shutters Windows/Doors 11 Electric Plumbing Sprinklers Generator Roof Root pitch Total Sq. Ft of Construction: SFt. of First Floor: Cost of Construction: $ 800.00 Utilities:n Sewer ❑ Septic Building Height: OWNERAESSEE: CONTRACTOR: Name Henry Broman Name: Manuel Duran Address: 744 E Prima Vista Lane Company: First Choice Plumbing Solutions LLC City: Port Saint Lucie State: FL Zip Code: 34952 Fax: Phone No. Address: 1887 SW South Macedo Blvd City: Port Saint Lucie State -.FL Zip Code: 34984 Fax: Phone No. 7728701414 E -Mail: Fill in fee simple Title holder on next page ( if different from the Owner listed above) gmail.com E -Mail: firstchoiceplumbingsolutions@gmaii.com State or County License: CFC1427369 If value of construction is $25DO or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: _ Not Applicable Name: Address: MORTGAGE COMPANY: _ Not Applicable Name: Address: City: State: Zip: Phone: City: State: Zip: Phone FEE SIMPLE TITLE HOLDER: Not Applicable Name: Address:,wrsws-th mated -ed BONDING COMPANY: Not Applicable Name: Address: City:. City: Zip: Phone: Zip: Phone: OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize thepermit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded -posted on the jobsite before the first inspe'gion. If you intend to obtain financing, consult; Mth er or an attorney before commenciniz work or eecordine your Notice of Commencement. Signature of r as Agent for Owner I Signature Holder STATE OF FL6'RII) STATE OF �-`L OIDA' COUNTYOF ���� ` COUNTY OF The f� r�g,„oing instr ent was acknowledged before me The forgoing instrument was acknowledged before me this'd day of �tik� 20 % by this day of N7�,q t� r 20by Name of p rson making statement Personally Known OR Produced Identification Type of Identification Prod ceo r 4 B t 1\ 15,, !!L 1 1\ t n A a A e� (Signature of Notary Pubfic- State of Floriba Name of p rs n making statement Personally known _ OR Produced Identification Type of Identification ProdUced j (Signature of NotaryPublic- State of Florida j Rev. 8/2/17 �ARY� so Arians Veneziano t y Ariana Ven ziam?,� Q Commission No. NOTAO LIC Commission No. TAR' P 9t"J ,- STATE OF FLORIDA ix OF FLORIDA Comm# GG 185914 © CoSTATE mm# GG185914 ce 1g Expires 2/14/2022 ti Expires 2/14/2022 REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEATURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED Rev. 8/2/17 0 al.1 Water Temperature Control Controller Controller Cable Safety !Devices Clearances from Combustibles Clearances from Non -combustibles * 24 inches required for serviceability Min. l Max. Gas Supply Pressure Manifold Gas Pressure (inches W.C.) (sea level) NOx Simulation feed forward and feedback MC-91-2US (included) Deluxe controller: MC -100V-1 US (optional) Bathroom controller: BC-10OV-1 US (optional) MCC-91-2US (optional; for hyrdonic applications) Non -polarized two -core cable, minimum 22 AWG • Flame failure - Flame Rod • Boiling protection • Combustion fan rpm check • Over current - glass fuse • Top of heater - 12 inches • Front (Panel) - 24 inches • Front (Exhaust) - 24 inches • Top of heater - 2 inches • Front (Panel) - 0 inches • Front (Exhaust) - 24 inches Natural Gas: min 5" W.C. Propane Gas: min 8" W.C. • Remaining flame (OHS) • Thermal fuse • Automatic frost protection • Back of heater - 0 inches • Ground 1 bottom - 12 inches • Sides of heater - 6 inches • Back of heater - 0 inches • Ground / bottom - 2 inches • Sides of heater - 118 inch max 10.5" W.C. max 13.5" W.C. Natural Gas: high fire 2.2" W.C. low fire 0.61" W.C. Propane Gas: high fire 3.4" W.C. low fire 0.93" W.C. Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels Limited Heat_ exchanger: 10 years* for residential and hydronic applications, increased to 12 years* if Warranty installed with an isolation valve kit; All other parts: 5 years'; Labor: 1 year (* reduced to 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater) Refer to the manual for complete warranty information. Rinrtai Corporation - 103 International Drive •Peachtree City, GA 30269 • Toll -Free. + 7F714.04 WEIGHT: 43.6 L° 0.28 (7.2) Ib (19.8 kg) 9.27 (235.5) 0.59 (15) 3A5 COWECT ION (356.6) � _- � • .• i �_ I � I O O G 8.90 (226) (— 7 B I L I HOT WATEF OUTLETC - EF G D — co EXI 0 WaTER 1%ET/ m u� xn rn D1IVIEN- DIIVIEN- SION Inches (mm) 510N Inches (mm) N N A {CTAS} 1.31 (33.2) D 4.33 (110) A (GOLD) 1.93 (49) E 2.91 (73.8) A (H07) 1.35 (34.4) F 1.61 (40.8) 00 00 00 oa B 3.96 (100.7) G 2.87 (73) A Rinrtai Corporation - 103 International Drive •Peachtree City, GA 30269 • Toll -Free. G 1.17 (29.8) 1-800-621-9419 -Fax: 678-364-8643 • www.rinnai.us • Type of Appliance 0 Rinnai Model Number Minimum/Maximum Gas Rate (Input) Electrical Electrical Consumption Ignition System Hot Water Capacity Temperature Temperature (without remote) Installation Energy Factor Service Connections Water Flow Control Minimum/Maximum Water Supply Pressure • Temperature controlled, continuous flow, gas hot water system • Certified for installation in manufactured (mobile) homes • Forced combustion • Energy Star qualified REU-VC2528W-US 10,300 - 180,000 BTU/h Appliance: AC 120 Volts - 60 Hz Controller: DC 12 Volts Normal: 57 w Standby: 2 w Anti -frost protection: 104 w Direct electronic ignition Minimum flow rate: 0.26 GPM Minimum activation flow rate: 0.4 GPM Maximum flow rate: 7.5 GPM 98° - 120'° F (factory default) Maximum temperature is selectable at 120° F or at 140° F; 980 - 160° F available with the MCC -91-2 controller for hydronic applications 120' F (factory default) or 140° F Outdoor only Natural Gas: 0.82 Propane: 0.82 Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT Hot water outlet: 314 inch MNPT Water flow sensor, electronic water control device and fixed by-pass 20 - 150 PSI (recommended 30--80 PSI for maximum performance) , Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. 8.0 7.0- —6.fl F F 4.0 E 3.fl — _ -- 2.0 - --- 1.0 - " - I 0.0-- 0 25 50 75 100 125 150 delta T - Temperature Rise °F) O 2012 Rinnai Corporation V75e SP 312012 „g r „M [Ii�t a