HomeMy WebLinkAboutProduct Approval (2)IIWAMP111111
Florida Building Code Online
_ -c--
Business & Professional Regulation
4..ri.
Tom' "T�' ►�tT-' �f
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us 8CIS Site Map Links Search
!ctf:
dopr T�x�
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
FL20853-R2
Application Type
Revision
Code Version
2017
Application Status
Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Evaluation Entity
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
FT Synthetics Inc.
13120 76 Ave Unit 1
Surrey, NON -US 98225
(604) 594-3439
rrobson@ftsyn.com
Russ Robson
rrobson@ftsyn.com
Russ Robson
12179 86 Ave
Surrey, NON -US 00000
(604) 594-3439
rrobson@ftsyn.com
Roofing
Underlayments
Evaluation Report from a Product Evaluation Entity
Intertek Testing Services NA, Inc.
Intertek Testing Services NA, Inc. - QA Entity
01/01/2020
Intertek Testing Services NA, Inc.
Standard
ASTM D226
Method 1 Option C
Year
2009
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtbxPgODTr'%2bX1%2fn2hm4SoV8T9TdomZjJ6ejBsbJRYLQVA%3d%3d 1/2
12/20/2018
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Florida Building Code Online
01/08/2018
01/10/2018
01/14/2018
Summary of Products
'
FL Model, Number or Name
20853.1 FT Synthetics Roof Underlayments
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other:
Description
Synthetic Roofing Underlayment
Installation Instructi" s
i FL20853 R2 II FT Synth tics Roof Underlayr
Instructions.pdf
Verified By: Intertek Tesng Services NA, Inc.
Created by Independe Third Party:
Evaluation Report
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida :: Privacy.Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
W] l6ff� eRa a
Credit Card
salsGS
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtbxPgODTr%2bX1%2fn2hm4SoV8T9TdomZjJ6ejBsbJRYLQVA%3d°/o3d 2/2
D SILVER
thetic Roofing U nderlayment
Installation Instructions:
Caution: Always follow Safety Instruction, Building Codes and Safe Work Practices
issues by the local Govt. bodies (e.g. OSHA / WCB)
FT Synthetics products should be installed with Plastics Cap or Metal Cap nails with either ring shank
or smooth shank Nails. DO NOT USE STAPLES. Use of staples will void the Manufacturer's warranty.
FT Synthetics products are a secondary layer protection approved for installation over Plywood with
proper fasteners. FT Synthetics underlayment is an air, vapour and water barrier with <1 Perm.
FT Synthetics underlayment is laid out horizontally with printed side up using 6" vertical laps and 4"
horizontal laps. The overlaps ensure that the water runs over the overlaps without getting under the
material. Before installing the underlayment ensure that the roof is clear of any debris or any sharp
protrusions.
Product must be attached to the roofing structure using 1" plastic or metal cap nails. Product must be
fastened with the nail pattern printed on the product. All anchoring must be performed flush to the
roof, 90 degrees to the roof deck that will hold the material tightly with the plywood. The use of every
other anchoring location printed on the product is also acceptable. For prolonged exposure, double
the overlaps and use every anchor location. Product has 90 Days UV protection but it should not be
considered a final roofing system. A proper final roofing system should be installed over the product
to get the proper protection. Product is a secondary barrier used over plywood, under a roofing
system like wood and asphalt shingles and metal.
Safety Notification:
FT Synthetics products are designed with the GRIPSPOT technology for better skid protection for the
roofer but product may become slippery due to high moisture, frost, rain, water, dust, debris or other
conditions. Use precautions when working on the roof. Fallow all local and federal safety codes when
installing any roofing system including FT Synthetics products. Failure to adhere to those procedures
may result in serious injury or even death.
FT SYNTHETICS Unit 1-13120 - 76th Avenue Toll Free Ph: 1-844-353-9839
Aff Surrey BC V3W 3H8 Phone: 604-594-3439
Fax: 604-594-3589
Canada www.ftsyn.com
-1-
Single Layer Application of FT SILVER
For slopes greater that 4:12 FT SILVER should be installed horizontally starting
from the bottom of the roof with a 4 inch overlaps working up the roof.
`Roof D
6" (150 mm)
Vertical Overlap
--------------1 --------
4" (100 mm)
____-_---- Horizontal Overlap---
48" (122 cm)
Eave Drip Edge Under Underlayment
Rake Drip Edge
Over
Underlayment
Fasten underlayment
as specified in the
installation instructions
Double Layer Application of FT SILVER
For slopes 2:12 to 4:12 FT SILVER should be installed horizontally starting from the
bottom of the roof with a 4 inch overlaps working up the roof.
0 oof
TV
�/ O
25' (64 cm)
125" (64 cm)
48" (122 cm)
Eave Drip Edge Under Underlayment
Rake Drip Edge
Over
Underlayment
Fasten underlayment
as specified in the
installation instructions
FT SYNTHETICS Unll 1-13120 - 76th Surrey BC V3W 3H8 Phone: Toll Free Ph: 1-844-353-9839
Phone: 604-594-3439
Fax: 604-594-3589
Canada www.ftsyn.com
-2-
GOLD
Synthetic Roofing Underlayment
Installation Instructions:
Caution: Always follow Safety Instruction, Building Codes and Safe Work Practices
issues by the local Govt. bodies (e.g. OSHA / WCB)
FT Synthetics products should be installed with Plastics Cap or Metal Cap nails with either ring shank or
smooth shank Nails. DO NOT USE STAPLES. Use of staples will void the Manufacturer's warranty.
FT Synthetics products are a secondary layer protection approved for installation over Plywood with
proper fasteners. FT Synthetics underlayment is an air, vapour and water barrier with <1 Perm.
FT Synthetics underlayment is laid out horizontally with printed side up using 6" vertical laps and 4"
horizontal laps. The overlaps ensure that the water runs over the overlaps without getting under the
material. Before installing the underlayment ensure that the roof is clear of any debris or any sharp
protrusions.
Product must be attached to the roofing structure using 1" plastic or metal cap nails. Product must be
fastened with the nail pattern printed on the product. All anchoring must be performed flush to the
roof, 90 degrees to the roof deck that will hold the material tightly with the plywood. The use of every
other anchoring location printed on the product is also acceptable. For prolonged exposure, double the
overlaps and use every anchor location. Product has 180 Days UV protection but it should not be
considered a final roofing system. A proper final roofing system should be installed over the product to
get the proper protection. Product is a secondary barrier used over plywood, under a roofing system
like wood and asphalt shingles, tiles, slate and metal roof.
a
Safety Notification:
a
FT Synthetics products are designed with the GRIPSPOT technology for better skid protection for the
roofer but product may become slippery due to high moisture, frost, rain, water, dust, debris or other
N
conditions. Use precautions when working on the roof. Follow all local and federal safety codes when
installing any roofing system including FT Synthetics products. Failure to adhere to those procedures
i
may result in serious injury or even death.
I
FT SYNTHETICS Unit 1-13120 - 76th Avenue
Surrey BC V3W 3H8
Canada
-3-
Toll Free Ph: 1-844-353.9839
Phone: 604-594-3439
Fax: 604-594-3589
WWWASyn.corn
Single Layer Application of FT GOLD
For slopes greater that 4:12 FT GOLD should be installed horizontally starting from
the bottom of the roof with a 4 inch overlaps working up the roof.
6" (150 mm)
Vertical Overlap
Eave Drip Edge Under Underlayment
Rake Drip Edge
Over
Underlayment
Fasten underlayment
as specified in the
installation instructions
Double Layer Application of FT GOLD
For slopes 2:12 to 4:12 FT GOLD should be installed horizontally starting from the
bottom of the roof with a 4 inch overlaps working up the roof.
Eave Drip Edge Under Underlayment
take Drip Edge
)ver
Jnderlayment
n underlayment
ecified in the
lation instructions
FT SYNTHETICS Unit 1-13120 - 76th Avenue Toll Free Ph: 1-844-353-9839
Surrey BC V3W 3H8 Phone: 604-594-3439
Fax: 604-594-3589
Canada www.ftsyn.com
-4-
PLATINUM
Synthetic Roofing Underlayment
Installation Instructions:
Caution: Always follow Safety Instruction, Building Codes and Safe Work Practices
issues bythe local Govt. bodies (e.g. OSHA / WCB)
FT Synthetics products should be installed with Plastics Cap or Metal Cap nails with either ring shank
or smooth shank Nails. DO NOT USE STAPLES. Use of staples will void the Manufacturer's warranty.
FT Synthetics products are a secondary layer protection approved for installation over Plywood with
proper fasteners. FT Synthetics underlayment is an air, vapour and water barrier with <1 Perm.
FT Synthetics underlayment is laid out horizontally with printed side up using 6" vertical laps and 4"
horizontal laps. The overlaps ensure that the water runs over the overlaps without getting under the
material. Before installing the underlayment ensure that the roof is clear of any debris or any sharp
protrusions.
Product must be attached to the roofing structure using 1" plastic or metal cap nails. Product must be
fastened with the nail pattern printed on the product. All anchoring must be performed flush to the
roof, 90 degrees to the roof deck that will hold the material tightly with the plywood. The use of every
other anchoring location printed on the product is also acceptable. For prolonged exposure, double
the overlaps and use every anchor location. Product has 180 Days UV protection but it should not be
considered a final roofing system. A proper final roofing system should be installed over the product
to get the proper protection. Product is a secondary barrier used over plywood, under a roofing
system like wood and asphalt shingles, tiles, slate and metal roof.
Safety Notification:
FT Synthetics products are designed with the GRIPSPOT technology for better skid protection for the
roofer but product may become slippery due to high moisture, frost, rain, water, dust, debris or other
conditions. Use precautions when working on the roof. Follow all local and federal safety codes when
installing any roofing system including FT Synthetics products. Failure to adhere to those procedures
may result in serious injury or even death.
Unit 1-13120 - 76th Avenue Toll Free Ph: 1-844-353-9839
IFFOAT"IFT SYNTHETICS Surrey BC V3W 3H8 Phone: 604-594-3439
Fax: 604-594-3589
Canada www.ftsyn.com
-5-
Single Layer Application of FT PLATINUM
For slopes greater that 4:12 FT PLATINUM should be installed horizontally starting
from the bottom of the roof with a 4 inch overlaps working up the roof.
TRoof Deck^
Rake Drip Edge
4" (100 mm)
_ _ _ _ _ _ Horizontal Overlap
_ _ _ Over
- --- -- Underlayment
48" (122 cm)
Fasten underlayment
6"150 mm as specified in the
( )
Vertical Overlap installation instructions
Eave Drip Edge Under Underlayment
Double Layer Application of FT PLATINUM
For slopes 2:12 to 4:12 FT PLATINUM should be installed horizontally starting from
the bottom of the roof with a 4 inch overlaps working up the roof.
oRoof Deck �—�`-
48" (122 cm)
25" (64 cm)
25" (64 cm)
Eave Drip Edge Under Underlayment
Rake Drip Edge
Over
Underlayment
Fasten underlayment
as specified in the
installation instructions
FT SYNTHETICS Unit 1-13120 - 76th Avenue Toll Free Ph: 1-844-353.9839
Surrey BC V3W 3H8 Phone: 604-594-3439
Fax: 604-594-3589
Canada www.ftsyn.com
-6-
r
101MMY4 11
Breathable Synthetic Underlayment
Installation Instructions:
Caution: Always follow Safety Instruction, Building Codes and Safe Work Practices
issues bythe local Govt. bodies (e.g. OSHA / WCB)
FT Synthetics HYDRA should be installed with Plastics Cap or Metal Cap nails with either ring shank or
smooth shank Nails. DO NOT USE STAPLES. Use of staples will void the Manufacturer's warranty.
FT Synthetics HYDRA is a secondary layer protection approved for installation over Plywood with
proper fasteners. FT Synthetics HYDRA underlayment is laid out horizontally with printed side up
using 6" vertical laps and 4" horizontal laps. The overlaps ensure that the water runs over the
overlaps without getting under the material. Before installing the underlayment ensure that the roof
is clear of any debris or any sharpprotrusions.
Product must be attached to the roofing structure using 1" plastic or metal cap nails. Product must be
fastened with the nail pattern printed on the product. All anchoring must be performed flush to the
roof, 90 degrees to the roof deck that will hold the material tightly with the plywood. The use of every
other anchoring location printed on the product is also acceptable. For prolonged exposure, double
the overlaps and use every anchor location. Product has 180 Days UV protection but, it should not be
considered a final roofing system. A proper final roofing system should be installed over the product
to get the proper protection. Product is a secondary barrier used over plywood, under a roofing
system like wood and asphalt shingles and metal.
Safety Notification:
FT Synthetics products are designed with the GRIPSPOT technology for better skid protection for the
roofer but product may become slippery due to high moisture, frost, rain, water, dust, debris or other
conditions. Use precautions when working on the roof. Follow all local and federal safety codes when
installing any roofing system including FT Synthetics products. Failure to adhere to those procedures
may result in serious injury or even death.
Unit 1-13120 - 76th Avenue Toll Free Ph: 1-844.353-9839
FT SYNTHETICS Surrey BC V3W 3H8 Phone: 604-594-3439
Fax: 604-594-3589
Canada www.ftsyn.com
-7-
Single Layer Application of FT HYDRA
For slopes greater that 4:12 FT HYDRA should be installed horizontally starting
from the bottom of the roof with a 4 inch overlaps working up the roof.
6" (150 mm)
Vertical Overlap
Eave Drip Edge Under Underlayment
Rake Drip Edge
Over
Underlayment
Fasten underlayment
as specified in the
installation instructions
Double Layer Application of FT HYDRA
For slopes 2:12 to 4:12 FT HYDRA should be installed horizontally starting from the
bottom of the roof with a 4 inch overlaps working up the roof.
Eave Drip Edge Under Underlayment
fake Drip Edge
Dver
Jnderlayment
'n underlayment
)ecified in the
Ilation instructions
Unit 1-13120 - 76th Avenue Toll Free Ph: 1-844.353-9839
FT SYNTHETICS Surre BC V3W 3H8 Phone:604-594-3439
y Fax
Fax: 604-594-3589
Canada www.ftsyn.com
-8-