y E _ FL# FL15487-R6
irsewit�' _44.1a
Application Type Revision
Code Version 2017
Application Status Approved
Comments i
E1
Archived 0
Product Manufacturer GAF
Address/Phone/Email 1 Campus Drive
Parisppany,NJ 07054 Lij
(800)766-3411 I
mstieh@gaf.com
�]
Authorized Signature Robert Nieminen
lander@nemoetc.com
i
Technical Representative William Broussard
Address/Phone/Email 1 Campus Drive
Parsippany,NJ 07054
(800)766-3411
TechnicalQuestionsGAF@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
0 Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/24/2019
Validated By John W.Knezevich,PE
© Validation Checklist-Hardcopy Received
Certificate of Independence FL15487 R6 COI 2017 01 COI Nieminen.ndf
Referenced Standard and Year(of Standard) Standard Year
ASTM D226(physicals) 2009
ASTM D4533(tear) 2015
Equivalence of Product Standards
Certified By
Sections from the Code
I
i
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDcltep%2bDhVRQ... 3/26/2018
Florida Building Code Online Page 2 of 2 •
Product Approval Method Method 1 Option D
Date Submitted 12/15/2017
Date Validated 12/18/2017
Date Pending FBC Approval 12/21/2017
Date Approved 02/13/2018
Summary of Products
FL# Model,Number or Name Description
15487.1 GAF Synthetic Roof Underlayments Synthetic Roof Underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL15487 R6 II 2017 12 FINAL ER GAF Synthetic
Approved for use outside HVHZ:Yes Underlavments FL15487-R6.odf
Impact Resistant:N/A Verified By:Robert Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other:Refer to ER Section 5 for Limits of Use. Evaluation Reports
FL15487 R6 AE 2017 12 FINAL ER GAF Synthetic
Underlayments FL15487-R6.pdf
Created by Independent Third Party:Yes
(Back) INexti
Contact Uq::3601 Blair Stone Road.Tallahassee FL 32399,phone:850-487-1824
The State of Florida Is an AA/EEO employer.Co vrioht 2007-2013 State of Florida ::privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to
Section 455275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click be,...
Product Approval Accepts:
IGO
credit Card
Safe
...securityM I~'TIticS'
. l
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtep%2bDhVRQ... 3/26/2018 •
'
EXTERIOR RESEARCH&DESIGN,LLC.
certificate of Authorization#9503
cPU\11~TY ERD
3S3CHRISTIAN STREET,UNIT#13
OXFORD,CT 06478
(203)262-9245
EVALUATION REPORT
GAF Evaluation Report 01506.03.12-R6
1Campus DhveFL15487-R6
Parsippany, NJ 07054 ��Dateof�ssuanne:D4���� 12
Revision��1��1S���17
(800)766-3411
ScoPc
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen',
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: GAF Synthetic Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
Comr/musuCoxxpuAwceThisEva|uationReportisvaUdunti|suchtimeasthenamedproduct(s)chanQesthereherenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinityj ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
AovsnnsowsmT The Evaluation Report number preceded by the words "TrinUy(ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consistof pages 1 through 6.
Prepared by:
Robert P.E.�K� The facsimile seal appearing was authorized by Robert
Florida Registration No.59166,Florida DCA ANE19B , ��R.E.»»12/15/2017.This does not serve as an
electronically signed document.
CERTIFICATIONor|mrepcwosmcs:
1. Trinity ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company
manufacturing or distributing products it evaluates.
2. Trinity'ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing
products for which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval'
process of the product.
5. This is a building code evaluation. Neither Trin|ty!EKD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
�
!
Qi TRINITY|����
^��
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Undedayment \
,
Compliance Statement: GAF Synthetic Roof Underlayments,as produced by GAFhave demonstrated compliance
with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the
applicable sections of the following Standards. Compliance is subject to the Installation Requirements and
Limitations/Conditions of Use set forth herein. .
2. STANDARDS:
Section Property Standard Year ,
1507.1.1,T1507.1.1 Unrolling,Breaking Strength, ASTM D226 2009 /
Pliability
| 1507.1.1 Tear Strength ASTM D4533 2015
3. REFERENCES:
Entity Examination Reference Date
ERD(TST 6049) Physical Properties n3360.02.07'2'n1 03/13/2007 !
cnonsTbO49> Physical Properties G12110.12,08 12/02/2008 \
PRI(TST 5878) Physical properties umY-003'02'01 03/19/2002
PRI(TST 5878) Physical properties sAF-224'02-01 07/27/200* i
PRI(TsTso7o) Physical properties aAF349-02'01 07/03/2012
PRI(TST 5878) FBC 1507.1.1(Exception) GAF-818-02-01 12/05/2017 '
ITS(TST 1509) Physical properties 100258583C0Q-010A 01/11/2011
Miami-Dade(CER 1592) HVHZ compliance 16'1213.04 11/16/2017
Miami-Dade(CER 1592) HVHZ compliance 16-1216.02 02/02/2017 ,
ICC-ES(EVL2396) IBC/IRC compliance sn'2053 07/01/2017
ICC-ES(EVL2396) |oc/|nccompUonce ESR-2808 07/01/2017
ICC-ES(EVL2396) IBC/IRC compliance ESR-3286 02/01/2017
UL,LLC(QUA 9625) Quality Control R10689;Charleston,SC 06/16/2017
UL,LLC(QUA 9625) Quality Control x10689;North Bay,ON 04/05/2017
. UL,LLC(QUA 9625) Quality Control R10689;Fontana,CA 07/07/2017
UL,LLC(QUA 9625) Quality Control R10689;McGregor,TX 05/24/2016
UL,LLC(QUA 9625) Quality Control x10689;Pryor,OK 06/20/2017
UL,LLC(QUA 9625) Quality Control R10689;Mission,BC 06/27/2017 .
4. PRODUCT DESCRIPTION:
4.1 Deck-Armorm Premium Breathable Roof Deck Protection iso non-woven, spun-bonded polypropylene
laminated polyethylene scrim sheet roof underlayment, available in 48-inch or 54-inch roll widths; mees
FBC 1507.1.1(Exception).
4.2 RoofPrew SBS-Modified All-Purpose Underlayment is a fiberglass-reinforced, S135 modified bitumen roof
underlayment;meets AC165. \
4.3 Shing|e'Knotew Roof Deck Protection is a fiberglass reinforced, asphaltic roof underlayment; meets FBC
1507.1.1(Exception).
4.4 StormSofe= Anchor Sheet is a polypropylene woven fabric which serves as an anchor sheet in two-p|
roof underlayment systems;meets FBC 1507.1.1(Exception). |
4.5 Tiger Paw= Roof Deck Protection is a non-woven, polypropylene reinforced, polymer coated roof
under|ayment;meets FBCz5o7.1.1(E^zeption). '
Exterior Research and Designuc Evaluation Reprt 01506.03.12-R6
Certificate of Authorization#9503 6TH EDITION(2o z)mcmow'xvnzcuxLoxnom pu5487-n6
GAF Synthetic Roof Linderlayments Revision n'1a/15/uo1r
� .
Page zv,a '
.
TRINI11r I ERD
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity!ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved RoofingMaterials
Directory
or test report from accredited testing agency for fire ratings of this product.
5.4 GAF
Synthetic Roof Underlayments maybe
Y used with any prepared roof cover
. P where the product
specifically referenced within FBC approval
p duct is
documents. If not liste
d, a request may be made to the
Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the
prepared roof covering.
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Underlayment Asphalt Foam-On Wood Slate or
y Shingles Nail-On Tile Tile Metal Shakes& Simulated
Shingles Slate
Deck-Armor'"'Premium '
Breathable Roof Deck Yes No No Contact Mfg Contact Mfg = Contact Mfg
Protection
RoofProT"SBS-Modified
All-PurposeYes
No, No No Yes Yes ,-
Underlayment
Shingle-Mate®Roof
Deck Protection es Nor No No No NO
U
y
r �
Tiger Paw"'Roof Deck
Protection Yes No = No Contact Contact Contact
Mfg. Mfg Mfg.
5.6 Exposure Limitations:
Deck-ArmorTM Premium Breathable Roof Deck Protection; RoofProT" SBS-Modified All-Purpose
Underlayment; Shingle-Mate® Roof Deck Protection; StormSafew Anchor Sheet; Tiger Pawl" Roof Deck
Protection shall not be left exposed for longer than 30-days after installation.
6. INSTALLATION:
6.1 GAF Synthetic Roof Underlayments shall be installed in accordance with GAF published installation
instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application.
16 3 Deck-Armor" Premium Breathable Roof Deck Protection:
6.3.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC
Table 1507.1.1 for the type of prepared roof covering to be installed,taking into account the wider sheet-
width for double-layer applications.
6.3.2 Fasteners shall be 1-inch diameterlastic-ca
p pped corrosion resistant nails or 1-inch diameter plastic-
capped,corrosion resistant staples.
Exterior Research and Design,LLC.
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Evaluation Report 01506.03.12-R6
GAF Synthetic Roof Underlayments FL
Revision 6:12/15/20/15/20R6
17
Page 3 of 6
Ti
TRINI ERD
6.3.3 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of Liberty' SBS Self-
Adhering Base/Ply Sheet;StormGuard® Film Surfaced Leak Barrier; UnderRoofTM 2 Polyester-Surfaced Leak
Barrier; UnderRoorm HT High Temperature Leak Barrier;WeatherWatch®Mineral Surfaced Leak Barrier or
WeatherWatch®XT Mat Surfaced Leak Barrier at vulnerable leak areas,including but not limited to eaves.
valleys, rakes, skylights and dormers. At eaves and valleys, install the leak barrier prior to installation of
the underlayment. Along the rake,install the underlayment, leaving 6 to 8-inch of the deck exposed,and
then install the leak barrier over the underlayment and exposed decking. At other areas, install the leak
barrier over the underlayment. Refer to FL10626.
6.3.4 Non-Tile Roof Installations:
Single Laver;Roof Slope>4:12:
Starting at the eave,fasten the eave edge and 6-inch wide end-laps 6-inch o.c. Fasten in the field of the roll
12-inch o.c.in two,equally spaced,staggered center rows.
Continue upsiope in a similar manner, maintaining minimum 3-inch side-laps and minimum 6-inch end
laps. Fasten 6-inch o.c. in the laps and 12-inch o.c. in two, equally spaced, staggered center rows in the
field. Ensure all end laps are staggered at least 3-feet apart.
Double Laver;2:12<Roof Slope<4:12:
If leak barrier (6.3.3) is not used, install a half-width sheet at the eave prior to subsequent courses.
Starting at the eave,fasten the eave edge and 6-inch wide end-laps 6-inch o.c.Fasten in the field of the roll
12-inch o.c.in two,equally spaced,staggered center rows.
Continue upslope in a similar manner,with minimum 25.5-inch side-laps for 48-inch wide rolls(resulting in
maximum 22.5-inch exposure) or minimum 28.5-inch side-laps for 54-inch wide rolls (resulting in
maximum 25.5-inch exposure) and minimum 6-inch end-laps. Fasten 6-inch o.c. along the low edge and
end laps and 12-inch o.c.in two,equally spaced,staggered center rows in the field. Ensure all end laps are
staggered at least 3-feet apart.
6:4 Tiger PawTM Roof Deck Protection;
6.4.1 Shall be installed in compliance with the requirements for ASTM D226,Type I or II underlayment in FBC
Table 1507.1.1 for the type of prepared roof covering to be installed,taking into account the wider sheet-
width for double-layer applications.
6.4.2 Fasteners shall be 1-inch diameter plastic-capped corrosion resistant nails or 1-inch diameter plastic-
capped,corrosion resistant staples.
6.4.3 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of LibertyTM SBS Self-
Adhering Base/Ply Sheet;StormGuard® Film Surfaced Leak Barrier;UnderRoofTM 2 Polyester-Surfaced Leak
Barrier;UnderRoof'T HT High Temperature Leak Barrier;WeatherWatch®Mineral Surfaced Leak Barrier or
WeatherWatch®XT Mat Surfaced Leak Barrier at vulnerable leak areas,including but not limited to eaves,
valleys, rakes, skylights and dormers. At eaves and valleys, install the leak barrier prior to installation of
the underlayment. Along the rake, install the underlayment, leaving 6 to 8-inch of the deck exposed,and
then install the leak barrier over the underlayment and exposed decking. At other areas, install the leak
barrier over the underlayment. Refer to FL10626.
6.4.4 Non-Tile Roof Installations:
Single Layer;Roof Slope>4:12:
Starting at the eave,fasten the eave edge and 6-inch wide end-laps 6-inch o.c. Fasten in the field of the roll
12-inch o.ck in two,equally spaced,staggered center rows.
Continue upslope in a similar manner, maintaining minimum 3-inch side-laps and minimum 6-inch end- I
laps. Fasten 6-inch o.c. in the laps and 12-inch o.c. in two, equally spaced, staggered center rows in the
field. Ensure all end laps are staggered at least 3-feet apart.
Exterior Research and Design,LLC. Evaluation Report 01506.03.12-R6
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL15487-R6
GAF Synthetic Roof Underlayments Revision 6:12/15/2017
Page 4 of 6
. .
— -- | —
! `
~��K�
nomm �mo ol �~
/ ^
Double Layer 2:12<Roof Slope<4:12:
If leak barrier (6.4.3) is not used, install a half-width sheet at the eave prior to subsequent courses.
Starting at the eavefasten the eave edge and 6-inch wide end-laps 6-inch o.c.Fasten in the field of the roll
12-inch o.c.in twoequally spaced,staggered center rows.
Continue upslope in a similar manner, with minimum 25.5-inch side-laps (resulting in maximum22.5'inch
exposure) and minimum 6-inch end-laps. Fasten 6-inch o.c. along the low edge and end laps and 12-inch
o.c.in two,equally spaced,staggered center rows in the field. Ensure all end laps are staggered at least 3-
fee apart.
6.5 StormSafe'm Anchor Sheet: -
6.5.1 StormSafe" Anchor Sheet is limited to use as a mechanically attached base layer in 2-ply underlayment
systems.
6.5.2 Fasteners shall be 1-inch diameter plastic- or steel-capped corrosion resistant nails; corrosion-resistant
nails&1-5/8-inch tin-caps;or Drill-Tec screws and plates.
6.5.3 Non-Tile Roof Installations:
Starting at the eave,fasten the eave edge and 6-inch wide end-laps 6-inch o.c.Fasten in the field of the
1Z�nchoz.\ntwo equally spaced,staggered center rows.
|
Continue upslope in a similar manner, maintaining minimum 3-inch side-laps and minimum 6-inch end-
laps. Fasten 6-inch o.c. in the laps and 12-inch o.c. in two, equally spaced, staggered center rows in the
field. Ensure all end laps are staggered at least 3-feet apart.
One the same day, install LibertyTM SBS Self-Adhering Base/Ply; StormGuard® Film Surfaced Leak Barrier;
UnderRoofTM HT High Temperature Leak Barrier; WeatherWatch® Mineral Surfaced Leak Barrier or
WeatherWatch®XT Mat Surfaced Leak Barrier over the StormSaferm Anchor Sheet. Refer to FL10626.
6.6- :;-RoofProT"SBS-Modified Ali-Purpose Underlayment and Shingle-Mate®Roof Deck Protection:
6.6.1 Shall be installed in compliance with the requirements for ASTM D226,Type I or II underlayment in FBC
Table 1507.1.1 for the type of prepared roof covering to be installed. No hammer tacks or staples are
permitted.
6.6.2 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of Uberty' SBS Self-
Adhering Base/Ply Sheet;StormGuard® Film Surfaced Leak Barrier;UnderRoof" HT High Temperature Leak
elf-Adher(ng8ase/P|y3heet;Borm8uandmFi|m3urfacedLeak8arrier;UnderRnof" MTHighTemperatureLeak
Barrier;WeatherWatch®Mineral Surfaced Leak Barrier or WeatherWatch®XT Mat Surfaced Leak Barrier at
vulnerable leak areas, including but not limited to eaves, valleys, rakes, skylights and dormers. At eaves
and valleys, install the leak barrier prior to installation of the underlayment. Along the rake, install the
underlayment, leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the
underlayment and exposed decking. At other areas, install the leak barrier over the undertayment. Refer
to FL10626.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
! '
! ! -
Exterior Research and Design,LLC. Evaluation Report 01506.03.12-R6
Certificate of AuthorIzation#9503 6TH EDITION(2017)FBC NON-H VHZ EVALUATION F115487-R6
GAF Synthetic Roof Underlayments Revision m12/z$uo17
Page 5 of 6
TRINITY. ERD
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements.
The following plants have qualified products under their respective physical properties specifications.
Plant
Specification ` ° Products)
North Bay,Ontario FBC 1507.1.1(Exception) Deck-Armor'"Premium Breathable Roof Deck Protection,StormSafe'"
Anchor Sheet
Fontana,CA AC165 RoofPro" SBS-Modified All-Purpose Underlayment
Pryor,OK _ FBC 1507.1.1(Exception) Shingle-Mate®Roof Deck Protection
McGregor,TX FBC 1507.1.1(Exception) Shingle-Mate®Roof Deck Protection
Mission,BC FBC 1507.1.1(Exception) Tiger Paw'"Roof Deck Protection
Charleston,SC FBC 1507.1.1(Exception) Tiger Paw'"Roof Deck Protection
9. QUALITY ASSURANCE ENTITY:
UL,LLC.—QUA9625;(847)664-3281
-END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 01506.03.12-R6
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL15487-R6
GAF Synthetic Roof Underlayments Revision 6:12/15/2017
Page 6 of 6