HomeMy WebLinkAboutProduct Approval - shinglesFlorida Building Code Online
Page 1 of 2
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map 11 Links Search
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
TAMKO Building Products, Inc.
PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
kerri_eden@tamko.com
Kerri Eden
kerri_eden@tamko.com
Kerri Eden
PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
kerri_eden@tamko.com
Roofing
Asphalt Shingles
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
Florida
ruProduct
Approval
USER: Public User
Florida License
Product Approval Menu > Product or Application
Search > Application List > Application Detail
-
FL #
FL18355-R4
Validated By
Application Type
Revision
Validation Checklist - Hardcopy Received
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
TAMKO Building Products, Inc.
PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
kerri_eden@tamko.com
Kerri Eden
kerri_eden@tamko.com
Kerri Eden
PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
kerri_eden@tamko.com
Roofing
Asphalt Shingles
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
Zachary R. Priest
the Evaluation Report
Florida License
PE -74021
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
01/07/2019
Validated By
Locke Bowden
Validation Checklist - Hardcopy Received
Certificate of Independence
FL18355 R4 COI TBP15001.4 2017 FBC Eval Report Shingles final.odf
Referenced Standard and Year (of Standard) Standard Year
ASTM D 3161 2016
ASTM D 3462 2010
ASTMD D 7158 2011
TAS 100 1995
Equivalence of Product Standards
Certified By Approved Testing Lab
FL18355 R4 Eguiv UL letter for standards for FBC 2017.1)df
Sections from the Code
https://floridabuilding.orR/pr/pr app dtl.as-ox?param=wGEVXOwtDauvosrHazGXOW83M... 2/6/2018
Florida Building Code Online
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 1 Option D
09/25/2017
09/27/2017
10/08/2017
12/12/2017
Page 2 of 2
FL # Model, Number or Name
Description
18355.1 Glass -Seal, Elite Glass -Seal,
ASTM D 3462 asphalt shingles and hip and ridge shingles
Heritage, Heritage Premium,
Heritage Woodgate, Heritage
Vintage, Hip and Ridge, and
Vintage Hip and Ridge Shingles
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL18355 R4 II TBP15001.4 2017 FBC Eval Report Shingles
final.pclf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest PE -74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL18355 R4 AE TBP15001.4 2017 FBC Eval Report
Shingles final.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 3 399 Phone: 850-487-1624
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487, 1395. *Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts:
RA U W eChgd'.
Credit Card
Safe
httDs:HfloridabuildinL.orL/nr/nr ann dtl.asnx?naram=wCTF.VXOwtl)rnlvnsrHa7.(-TX(1WRIM ?/F/?O1 R
, " CREEKCertificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 6T" EDITION (2017)
Manufacturer: TAMKO BUILDING PRODUCTS Issued September 25, 2017
220 West 4"' Street
Joplin, MO 64801
(417)624-6644
Manufacturing Plants: Joplin, MO
Phillipsburg, KS
Frederick, MD
Dallas, TX
Tuscaloosa, AL
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category: Roofing
Subcategory: Asphalt Shingles
Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1, 1523.6.5.1
Properties: Physical properties, Wind Resistance, Wind Driven Rain
REFERENCES
Entity
Report No.
Standard
Year
PRI Construction Materials Technologies (TST5878)
TAP -043-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -051-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -054-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -114-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -117-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -130-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -131-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -165-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -280-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -303-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -307-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -314-02-01 Rev 2
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -315-02-01
ASTM D 6381
2008(2013)e1
PRI Construction Materials Technologies (TST5878)
TAP -317-02-01
TAS 100
1995
UL LLC (TST9628)
02NK9507
ASTM D 3161
2016
UL LLC (TST9628)
04NK24366
ASTM D 3462
2010A
UL LLC (TST9628)
05NK28006
ASTM D 6381
2008(2013)e1
UL 2390
ASTM D 7158
2011
UL LLC (TST9628)
06NK03898
ASTM D 3161
2016
ASTM D 3462
2010A
UL LLC (TST9628)
08CA59132
ASTM D 3161
2016
UL LLC (TST9628)
09NK07896
ASTM D 3161
2016
ASTM D 3462
2010A
UL LLC (TST9628)
1OCA50498
ASTM D 3462
2010A
UL LLC (TST9628)
1OCA64882
ASTM D 3161
2016
UL LLC (TST9628)
11NK14014
ASTM D 3161
2016
ASTM D 3462
2010A
UL LLC (TST9628)
12CA24551
ASTM D 3161
2016
UL LLC (TST9628)
4786110543
ASTM D 6381
2008(2013)e1
UL LLC (TST9628)
4787043752
ASTM D 3161
2016
UL LLC (TST9628)
4787148748
ASTM D 7158
2011
ASTM D 3161
2016
ASTM D 3462
2010A
CREEK Technical Services LLC (ANE11669)
TBP15001.3
Calculations
2017
TBP15001.4
FL18355-R4
Page 1 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
C R K TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION
Elite Glass -Seal®
12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3 -tab
(Frederick, Joplin &
asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa)
ceramic granules complying with ASTM D 3462,
Glass -Seal
12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3 -tab
(Frederick &
asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa)
ceramic granules complying with ASTM D 3462.
Glass -Seal
12-1/4" x 36", ASTM D 7158, Class H self-sealing, 3 -tab asphalt shingle with fiberglass
(Joplin)
mat coated on both sides with asphalt and surfaced with ceramic granules complying
with ASTM D 3462. Shingles shall be used in the non-HVHZ only.
Heritage®
13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas, Frederick,
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Joplin, Phillipsburg &
complying with ASTM D 3462.
Tuscaloosa)
Heritage® Premium
13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas, Frederick,
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Phillipsburg &
complying with ASTM D 3462.
Tuscaloosa)
Heritage® Premium
12" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Frederick)
laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage® Vintage®
17-1/2" x 40", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Phillipsburg)
laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage® Woodgate
13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas & Frederick)
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
complying with ASTM D 3462.
Heritage® Woodgate
12" x 36-3/8", ASTM D 3161, Class F fiberglass reinforced, laminated architectural
(Frederick)
asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles
shall be used in the non-HVHZ only.
Hip and Ridge Shingles
12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt
(Frederick & Joplin)
shingle surfaced with mineral granules complying with ASTM D 3462.
Vintage® Hip and Ridge
12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle
(Phillipsburg)
surfaced with mineral granules complying with ASTM D 3462.
TBP15001.4 FL18355-R4 Page 2 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
rim GREEK
TECHNICAL SERVICES,
LLC
INSTALLATION
Elite Glass-Seal®
Basic Wind Speed (V„ it):
(Frederick, Joplin &
Basic Wind Speed (Vasd)
Tuscaloosa)
Deck (HVHZ):
Glass-Seal
(Frederick, Joplin (Non-
HVHZ) & Tuscaloosa)
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ)
Nailing
Area
Nailing
Area
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5-1/8 inch exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5 -1/8 -inch exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or "6 Nail Pattern" detailed below.
NAILS
Butt Edge
Figure 1. Elite Glass -Seal & Glass -Seal
4 Nail Pattern (Non-HVHZ only)
MAILS
-718"
5-1/8"
Butt Edge
Figure 2. Elite Glass -Seal & Glass -Seal
6 Nail Pattern
P_718t1
5-1/81,
TBP15001.4 FL18355-R4 Page 3 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GREEK
TECHNICAL SERVICES, LLC
Heritage®
(Dallas, Frederick, Joplin,
Phillipsburg & Tuscaloosa)
Heritage® Premium
(Dallas, Frederick
Phillipsburg & Tuscaloosa)
Heritage® Woodgate
(Dallas & Frederick)
Basic Wind Speed (V„ u): Max. 194 mph
Basic Wind Speed (Vasa): Max. 150 mph
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Deck (HVHZ):
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
Deck (Non-HVHZ):
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
Underlayment:
In accordance with FBC requirements.
Min. slope:
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation (HVHZ):
Installed with 5-5/8 in. exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ):
Installed with 5-5/8 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either 'A Nail
Pattern" or "13 Nail Pattern" detailed below.
FASTENERS NAIL ZONE
COMMON
BOND
EXPOSURE 5-5/8"
�- 12-1/211 -►�- 12-318" - ► -- 12-1 /2'L_� r-1 "
Figure 3. Heritage®, Heritage® Premium, and Heritage® Woodgate (Dallas)
4 Nail Pattern (non-HVHZ only)
M
NAIL ZONE
COMMON
BOND
IE 5-518"
1'—�►I f' i-1/2'� 7-112"+�1- r �/8"-►� 7-112"�7-1/2"-►� I4-1"
Figure 4. Heritage® & Heritage® Premium
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 4 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GREEK
TECHNICAL SERVICES, LLC
1 " �7.112 +7
TAMKO BUILDING PRODUCTS
Asphalt Shingles
NAIL ZONE/
COMMON BOND
EXPOSURE 5 518"
_J
-1/2'1.0 - -3/8'+-1/2+7-1/29+
Figure 5. Heritage® Woodgate
6 Nail Pattern
.-
0 Common Bond
PAI NT
LINE.
39-3/8"
Figure 6. Heritage®, Heritage® Premium, & Heritage® Woodgate
Alternate 6 Nail Pattern
7-718" * G-=----------------------------------------------------------------------------------------- -----I NAIL ZONE
6.118" EDGE OF
COMMON
AL
BOND
EXPOSURE
5-518"
ACCEPTABLE
/FASTENER LOCATION
DO NOT FASTEN
ALONG EDGE OF
--------------- ---------- COMMON BOND
PREFERRED
FASTENER
LOCATION
Figure 7. Heritage® (Tuscaloosa)
Expanded Nail Zone
Nail patterns from Figures 3, 4, and 6 may be placed in the nail zone as described above
TBP15001.4 FL18355-R4 Page 5 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GREEK
TECHNICAL SERVICES, LLC
Heritage® Premium Basic Wind Speed (V.u):
(Frederick) Basic Wind Speed (Vasd):
Deck (HVHZ):
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ):
FAS
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12. .
Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or "6 Nail Pattern" detailed below.
NAIL ZONE/
COMMON BOND
51/211 lIXPdi URE
1 �� 11 "--►� - 12" 11 � `� k--111
Figure 8. Heritage® Premium (Frederick)
4 Nail Pattern (non-HVHZ only)
A
NAIL ZONE/
FASTENERS COMMON BOND
51/2" EXPO RE 5"
1 u—� —91/21' +34— 9u—+3" 91/2" IF1"
Figure 9. Heritage® Premium (Frederick)
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 6 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GREEK
TECHNICAL SERVICES, LLC
Heritage® Woodgate Basic Wind Speed (V it):
(Frederick) Basic Wind Speed (Vasa):
Deck (Non-HVHZ):
TBP 15001.4
Underlayment:
Min. slope:
Installation (Non-HVHZ)
NERS
5-1}"
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or "6 Nail Pattern" detailed below.
IT
EXPOSURE Y
I ±
NAIL ZONE/
COMMON BOND
1 11'. 12-318"—'ice 11"
Figure 10. Heritage® Woodgate (Frederick)
4 Nail Pattern (non-HVHZ only)
AS
T�
5-112" EXPOSURE 5"
I
1"-1►I N- 9-112" �►�-3'-93/8"--►�1.3'+►� 9-112" -� [1-1"
1 Figure 11. Heritage® Woodgate (Frederick)
6 Nail Pattern
FL18355-R4
IL ZONE/
MMON BOND
Page 7 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GREEK
TECHNICAL SERVICES, LLC
Heritage® Vintage® Basic Wind Speed (V„ic):
(Phillipsburg) Basic Wind Speed (Vasa):
Deck (HVHZ):
Deck (Non-HVHZ)
Underlayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ):
ao'
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "5 Nail
Pattern" or "6 Nail Pattern" detailed below.
Exposure
%tch
Fasteners
r-- — — — — — — — -s — — — — -s-- --
17-1J2"
I=E,xu�?1N' 41M'—✓r-9-1M' —9-1w
1/ .1
—lana• aw—H
Figure 12. Heritage® Vintage®
5 Nail Pattern (non-HVHZ only)
40• _ I ExP=M
Figure 13. Heritage® Vintage®
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 8 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GREEK
TECHNICAL SERVICES, LLC
Hip & Ridge Basic Wind Speed (V„ic):
(Frederick & Joplin) Basic Wind Speed (Vasa)
Deck (HVHZ):
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation:
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements.
Installed with 5-1/8 inch exposure in accordance with the
FBC and manufacturer's published installation instructions.
The direction of the exposed end shall be away from the
prevailing wind.
Direction prevailing wind
Start 5-1/8" exposure
here-.�-
rn1
Figure 1
Fastener
Figure 2
1"
Fastener
45-W9
Figure 3
Figure 14. Hip & Ridge (Frederick & Joplin)
TBP15001.4 FL18355-R4 Page 9 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
LM TECHNICAL SERVICES, LLC
Vintage® Hip & Ridge Basic Wind Speed (V„ ic):
(Phillipsburg) Basic Wind Speed (Vasa):
Deck (HVHZ):
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation:
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements.
Installed with 5 inch exposure in accordance with the FBC
and manufacturer's published installation instructions. The
direction of the exposed end shall be away from the
prevailing wind.
Direction prevailing wind
5" exposure
Figure 1
1"
Fastener
�5-1/2"
Figure 2
5', exposure
1"
Fastener
r 15-1/2"
1/4" Figure 3
Figure 15. Vintage® Hip & Ridge (Phillipsburg)
TBP15001.4 FL18355-R4 Page 10 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
C RE K TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ.
4) Classification to ASTM D 7158 applies to exposure B & C with a building mean roof height of 60 -ft or less.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the
deck.
7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and code compliant detail shall prevail.
8) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 6t' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
;.,�� •..�,�•ENS�.Fs� 2017.09.25
'
No 74021 - 11:31:41
�•• STATE OF •41' _04'001
'.�0T�•;c� O R `Q P���: Zachary R. Priest, P.E.
S' ' • Florida Registration No. 74021
ONA\ +����� Organization No. ANE11669
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
TBP15001.4 FL18355-R4 Page 11 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.