Loading...
HomeMy WebLinkAboutProduct Approval (2) 1/2/2019 Florida Building Code Online SON I I I r SCIS Home i Log In- y User Registration ' Hot Topics Submit Surcharge ? Stats&Facts i Publications ` Contact Us t SCIS Site Map ; Links i Search , tidy r Product Approval : USER:Public User aW�c?fP;vszs ' � t;f Product Approval Menu>Product or Application Search>6ppliration List>Application Detail FL# FL5777-RS Application Type Revision RECEIVE Code Version 2017 JAN Application Status Approved JAN Q 3 2019 ST. Lucie County,Permitting Comments Archived 'r Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenu Ocala,FL 34474 (352)36$-6922 Ext 2 1 IL 'Dopy jiathrop@cws.cc Authorized Signature Kevin Pine kpine@cws.cc Technical Representative Jay Lathrop 1 Address/Phone/Email 1900 SW 44th Ave `rnJ Ocala,FL 34474 (352)366-6922 Ext 291 ` jlattlrop@cws.cc 4 Quality Assurance Representative Arturo Monteverde Address/Phone/Email 1900 SW 44th Ave Ocala,FL 34474 (352)368-6922 Ext 221 amonteverde@cws.cc Category LC ' Subcategory .j, Compliance Method sport from a Florida Registered Architect or a Licensed Florida of l Engineer tion Report-Hardcopy Received Florida Engineer or Architect Name who developed the Lucas A.Turner Evaluation Report ' Florida License PE-58201 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 07/21/2020 Validated By Steven M. Urich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL5777 R5 COI EvalReport244 .pdf Referenced Standard and Year(of Standard) Standard Year AAMA 450-10 2010 AAMA/WDMA/CSA 101/I.S.2/A440- 2005 TAS 202 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect PL5777 RS Equiv FL5777 E iyalency_Rdf 1/2/20 1 19 Florida Building Code Online Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/29/2017 Date Validated 09/29/2017 Date Pending FBC Approval 10/02/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 5777.1 Adjustable(Angled)Mull Adjustable Mullion for Alum.and PVC Windows. Limits of use Installation Instructions Approved for use in HVHZ:No FL5777 R5 11 CWS-243C.p gf Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact,Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Not for use in HVHZ.See Mullion Product Evaluation FL5777 RS AE EvaiReport243C.pd Report for complete list of Limitations and Conditions. Created by independent Third Party-.Yes 5777.2 '58 Mull Bar 3"Mull Bar for PVC Windows. Lim-its of Use Installation Instructions Approved for use In HVHZ:Yes FL5777 R5 II CWS-430C.p gLf Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resistant. No Created by Independent Third Party:Yes Design Pressure:N/A j Evaluation Reports Other:See Mullion Product Evaluation Report for complete list FL5777 R5 AE EvalReport430C.pdf of Limitations and Conditions of Use. Created by Independent Third Party:Yes 5777.3 759 Mull Bar 14"Mull Bar for PVC Windows. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL5777 R5 ft CWS-431C.pd Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See Mullion Product Evaluation Report for complete list FL5777 R5 AE E a Report431C.p f of Limitations and Conditions of Use. Created by Independent Third Party:Yes 5777.4 iO Mull Bar 5 1/2"Mull Bar For PVC Windows. Limits of Use Installation instructions Approved for use In HVHZ:Yes FL5777 R5 11 CWS-432C.pdf Approved for use outside HVHZ:Yes Verified By:Lucas A.Turner 58201 Impact Resistant;No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See Mullion Product Evaluation Report forcompletelist FL5777 R5 AE EvalRep2rt432C.pdf of Limitations and Conditions of Use. Created by Independent Third Party:Yes 5777.5 CWS-1950 Mull Bar 21"Mull Bar for Aluminum Windows. Limits of Use Installation Instructions Approved for use In HVHZ:No FL5777 RS 11 CWS-245C.pd Approved for use outside HVHZ:Yes Verified By:Lucas A.Turner 58201 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-N/A Evaluation Reports Other:Not for use in HVHZ;See Mullion Product Evaluation FL5777 R5 AEEvalRep-ort245C pdf Report for complete list of Limitations and Conditions of Use. Created by Independent Third Party:Yes 5777.6 952 Mull Bar 3"Mull Bar for Aluminum Windows. Limits of Use Installation Instructions Approved for use in HVHZ:No FL5777 R5 11 CWS-244C.pd Approved for.use outside HVHZ:Yes Verified By:Lucas A.Turner 58201 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-N/A Evaluation Reports Other:Not for use in HVHZ;See Mullion Product Evaluation FL5777 R5 AE EvaiRep-ort244C p&f Report for complete list of Limitations and Conditions of Use. Created by Independent Third Party:Yes 1/2/2019 Florida Building Code Online • Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available.to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: . Credit'CEird;,:w. • :;�iLi/lir t GENERAL NOTES: 3" PVC MULL BAR - NON-IMPACT 1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND,MANUFACTURED TO COMPLY WITH WINDOW SYSTEMS • SHOWN WDIFFERENT OPTIONS THE FLORIDA BUILDING CODE(FBC),CURRENT EDITION. 1900 SW 44TH AVE. 2.CONFIGURATIONS(SEE SHEET 2);VERTICAL OR HORIZONTAL. OCALA,FLORIDA 34474 www.cws.cc 3.SEE MULLION CHARTS FOR MAX.DESIGN PRESSURES AND LENGTH. (REFER TO SHEETS 2-3) 31f PVC 4,ANCHORAGE:THE 33 1/3%STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT.SEE SHEETS 9-10 FOR ANCHOR DETAILS.WINDLOAD MULL PAR DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. NON4MPACT 5.NOT APPROVED FOR IMPACT RESISTANCE. IMPACT PROTECTIVE SYSTEM IS -j z 0 <REQUIRED IN WIND BORNE DEBRIS REGION. � <Z?„ awo wwor-i 6.DESIGN PRESSURE OF MULLED UNITS SHALL BE CONTROLLED BY THE LESSER z III-J,a < 1z UJ DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL WINDOW UNITS, 0 LU gOz <w§>-0 w ANCHOR CLIP-- ANCHOR CLIP T DES GN PRESSURES AND INSTALLATION DETAILS SHOWN IN THIS DOCUMENT z z 2`4 0 0 /—C-N APPLY ONLY TO THE MULLION.WINDOWS MUST BE APPROVED UNDER SEPARATE 0 0 0 CS I-Df 0 0 �-z id CL APPROVAL. 0 z 0-Z U) z 00, zowzo 0 08.RESPONSIBOF SELECTING PRODUCTS TO MEET ANY MO 0 APPLICABLEILITY LOCAL LAWS,BUILDING CODES,FENESTRATION ORDINANCES OR OTHER SAFTEY 10 w;= 0 REQUIREMENTS RESTS SOLEY WITH THE ARCHITECT,ENGINEER OF RECORD, 5 0�: z I II II I0 (Dw BUILDING OWNER OR CONTRACTOR. w ILL'na:' ujgm Fx 4:tu 0 Cn 9.SINGLE UNITS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN IN THIS EL q. 0,0 0 IL DRAWING. SINGLE UNITS TO BE MULLED TOGETHER MUST BE MANUFACTURED BY aaLU CUSTOM WINDOW SYSTEMS,INC.AND MUST BE MADE OUT OF VINYL PVC OR D. X I I x I X EXTRUDED ALUMINUM, 10.VERTICAL MULLED UNITS MAY BE MULLED INDEFINITELYAS LONG ASTHE SINGLE UNIT WIDTH SHOWN HERE ANDIN.HEIGHT ARE NOT EXCEEDED,AND MULLIONS ARE ANCHORED AS It ......... %&-F El 11.HORIZONTAL MULLION SHALL EXTEND THE ENTIRE WIDTH OF THE MULLED UNIT. N. 58201 'rte I �P3�.Jr --J 7 ANCHOR CLIP VERTICAL MULLION IS USED TO MULL SIDE BY SIDE UNITS TOGETHER. EXAMPLE HDRIZ/.VERT.MULLION FOR SECTION VIEW ONLY .% ANCHOR CLIP— Lucas Turner 2017-09-28 07:10+20:00 0 I I 0 I 4/261201 LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE, NORTH PORT,FL 34288 PH.941-380-1574 X x SHEET DESCRIPTION: TABLE OF CONTENTS GENERAL NOTES ANDELEVATIONS GENERAL NOTES&ELEVATIONS..........-_1 DRAWN BY: DATE: DPCHARTS.................................................2-3 BOM&EXTRUSIONS ...........................4 ANCHOR CLIP RS 04/13/09 EXTRUSIONS.................................................5 5wr'm -fTE—V'. SECTION VIEWS.........................................6-7 EXAMPLE VERTICAL MULLION FOR CONFIGURATIONS&ANCHOR NOTES.. 8 PVC WINDOWS FOR SECTION VIEWS ONLY CWS-430 c INSTALLATION DETAILS..........................9-10 —�HEET 1:25 1 OF 10 DESIGN PRESSURE CHARPSF)FOR NON-IMPACTALUMINUM3"MULLION H-1758,11ORIZONTAL OR VERTICAL,WITH 16226r1767 CLIPS USING FOUR(4)#10 SCREW 9_ INTO WOOD or METAL,3/16"ITW TAPCONS or ELCO ULTRACONS INTO SOLID CONRETE WITH WASHERS PER CLIP. HOLLOW or GROUT-FILLED BLOCK REQUIRES FOUR(4) 1/4"ELCO ULTRACON WITH THE 1767 CLIP. OPENING WIDTH(in.) 39 45 51 57 1 63 69 75 81 87 931900 SW 44TH AVE. 99 1 1063/8 114 1 120 132 1 144 OCALA,FLORIDA 34474 37 120 120 120 120 1 120 120 120 120 120 116 109 102 96 1 91 83 76 www.CwS.CC 423/4 120 120 120 120 120 120 120 113 106 99 94 88 82 78 71 66 483/4 120, 120 120 120 120 113 105 98 92 86 81 76 71 68 62 57 5.11/8 120 120 120 120 111 103 95 89 83 79 74 69 65 62 57 52 3#1 PVC 57 120 120 120 112 103 95 88 82 77 73 69 64 60 58 63 49 MULL,BAR 63 120 120 110 100 92 85 79 74 69 1 65 62 1 58 54 52 47 44 NON-IMPACT -,r 66314 120 113 102 93 86 79 74 c 69 65 61 58 54 51 1 49 44 41 C_ 72 117 104 94 86 79 72 66 62 57 54 51 47 44 42 38 35 z 3: 76 103 90 81 73 671.- m.o ww06 61 56 52 49 46 43 40 37 36 32 30 z w-ja <t-!?w 4 32 77 69 62 57 52 48 45 42 39 37 3 z 80 88 Lu z0z m==!=_ 30 28 25 '2 :R(n 0 lr3t g Ill 84 76 67 59 53 49 45 42— 39 36 34 32 30 28 LL F-W 1 26 24 22 z Z �<Xujoo .1 90 62 54 48 43 39 36 34, 31 29 0 oho LS<:r�_Jx 27 26 24 22 21 19 18 L) oro t;,0-F U)cL c 0 96 51 44 39 35 32 30 1 28 26 24 23 21 1 20 18 18 16 15- zon-z t-=)co z L)td-:Dcj- -TO_2 42 37 33 29 27 25 1 23 21 20 19 18 1 16 15 1 15 - - F-9 m Z'0 LL 0 1063/8 37 32 29 26 24 22 1 20 19 18 17 16 15 - - <3: ;=F 0 z 2� O-Z - 114 1 30 26 23 21 19 17 -16 15 =, ='3:q Imo 0 U- 0�(nmwu)W 120 26 22 20 18 16 15 - w c*W. 0_j U) (L 9 a. of 0�w 126 22 19 17 15 - - 0 uj�o CL:c Ir 0� 132 19 1-715 - WX�:uj ul EL (L 138 17 15 DIP CHART IS FOR: NON-IMPACT 3'MULLION 1758,HORIZONTAL OR VERTICAL,USING EITHER(PER END): .......... 1522 or 1767 CLIPS sa201 �p -(4)#10 SCREWS INTO WOOD or METALz -(4)3116-ITW`TAPCONS or ELCO ULTRACONS INTO SOLID CONCRETE or WOOD z 1767 CLIPSper:* STATE 6P 4 -(4) 114"ELCO ULTRACONS INTO HOLLOW or GROUT-FILLED BLOCK q. ...........Iwo TRANSOM OVER TWIN TRANSOM OVER TRIPLE TWIN TRIPLE VERTICAL MULLION VERTICAL MULLION VERTICAL MULLION VERTICAL MULLION HORIZONTAL MULLION 9/26/2017 LUCAS A.TURNER,P.E. FI_PE#58201 1239 JABARA AVE. z NORTH PORT,FL 34288 ISINGLEI 11. 1-311-151 Z TWIN !_ w DESCRIPTION: D OR SHEET (TRIPLE) DP CHART D M UNITS 1522 or 1767 CLIP BELOW 4ANCHORS DRAWN BY: DATE: OPENING SIZE OPENING SIZE OPENING SIZE OPENING SIZE MULL LENGTH RS 04113/09 _dWG M 'REV,: CWS-430 C ii-i—EET ] DESIGN PRESSURE CHART(PSF) OR NON-IMPACT ALUMINUM 3"MULL H-1758, OR ONT OR RT CAL,WITH 1767 CLIPS USING SIX 6)#10 SCREWS INTO WOOD or METAL,3/16"ITW TAPCONS or ELCO TAPCONS WITH,WASHERS PER EACH END OF MULLION. HOLLOW or GROUT-FILLED BLOCK REQUIRE SIX(6)1W'ELCO ULTRACONS // r/77Ra�°r® •I /�/,,{ WITH THE 1767 CLIP. V(5Util1CG Ill fj�/Ij OPENING WIDTH(in.) WINDOW SYSTEMS1900 SW 44TH AVE. 39 45 51 57 63 69 75 81 87 93 99 .1063/8 114 120 132 144 OCALA,FLORIDA 34474 37 120 .120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 www.cws.cc 423/4 120 120 120 120 120 120. 120 120 120 .120 120 . 120 120 120 115 106 { 493/4 120 120 . 120 120 120. 120 120 120 120• 120 120 120 115 110 100 92 3"PVC' 53 1/8 120 120 120 120 120 120 120 120 120 120 119 112 105 -100 91 84 MULL BAR 57 120 120 120 120 120 120 120 120 116 109 102 95 89 1 84 77 71 NON-IMPACT 63 120 120 120 120 118 108 1 99 92 86 80 76 70 66 63 57 52 663/4 120' 120 120 109 99 91 83 77 72 68 64 59 55 53 48 44 72 120 107 95 86 79 72 66 62 57 54 51 47 44 42 38 _ 35 ¢ z y W o 0 = 76 103 90 81 73 67 61 56' 52 49 46 43 40 37 36 32 30 z D w o D w zoz w-?� Z 80 88 77 69 62 57 52 48 45 42 39 37 34 32 30 28 25 z z= a�5 2 Ln Wj O OF-0d<=Fo: 84 76 67 59 53 49 45 42 39 36 34 32 30 " 28 26 24 22 U o=F a w p o 90 62 54 48 43 39 36 34 31 29 27 26 24 22 21 19 18 F-z F o- 96 51 44 39 35 32 30 28 26 24 23 21 20 18 18. 16 zz p z --=,C-)en 102 42 37 33 29 27 25 23 21 20, 19 18 16 15 >- <�OwsMO_ 106318 37 32 29 26 24 22 20 19 18 17 16 - - - ¢ w } 15 o c 114 30 26 23 21 19 17 16 - - - - - w OD�rnDwinw 120 26 22 20 18 16 - - - - - _ a rn w o 0(n F- 126 22 19 17 15 - - - ~� w3:U3 132 19 17 o 138 17 - - - - - - - +t� OY44,' IV�i DP + CHART IS FOR: ++S pS�,,,,,RETG NON-IMPACT 3"MULLION 1758,HORIZONTAL OR VERTICAL,USING EITHER(PER END): V@�?.y.CENgF.,�Qy�r��. 1767 CLIPS �t No 59201 !f� -(6)#10 SCREWS INTO WOOD or METAL `*: 6 •* I (6)3/16"ITW TAPCONS or ELCO.ULTRACONS INTO SOLID•CONCRETE or WOOD (6) 1/4"ELCO ULTRACONS INTO HOLLOW of GROUT-FILLED BLOCKS TATE OF �W p+bNA�c� ++�+ TRANSOM OVER TWIN TRANSOM OVER TRIPLE TWIN TRIPLE HORIZONTAL MULLION VERTICAL MULLION VERTICAL MULLION VERTICAL MULLION VERTICAL MULLION 9/26/2017 LUCAS A.TURNER,P.E. (. FL PE#58201N 1239 JABARA AVE. i r z z N NORTH PORT,FL 3 288 z ISITWIN PH.941-380-1574 Lu E OR SHEET DESCRIPTION: o ITRIPCE1 DP CHART UNITS 1767 CLIP �BE-LOW� 6ANC ORS t I I DRAWN BY: DATE: OPENING SIZE --i OPENING SIZE 'OPENING SIZE OPENING SIZE F•— MULL LENGTH RS 04/13/09 DWG 0: REV.: CWS-430 C SHEET 1:1 3 OF 10 ITEM PART# DESCRIPTION T"MULUBARCLIP "L"MULUSARCUP I H-1758 1 3/8"x S'MULLION TUBE FRAME TYPE OPENING I (F-1522-XXX) (F-1767-XX)() NEW F-1522-013 F-1767-001 (("V 2 #10 OR#1214EXWASHER HEAD TEK SCREW*(see note below) Imlabw 3 #10 x 1 112",PANHEAD PHILIPS ZINC FLANGE WINDOW SYSTEMS Val 4 #10 FLAT WASHER RETRO F-1522-006 F-1767-001 1900 SIN 44TH AVE. 6 S-1522 RETRO,FIT MULL ANCHOR CUP NEW F-1522-013 F-1767-004(L&R) CCALA,FLORIDA 34474 7 S-1897 MULLION CLIP FIN RETRO F-1522-013 F-1767-004(L&R) WWw.CWS.Cc SEALANT NEW NOT RECOMMENDED F-1767-001 9 S-1895 DRIP CAP BOX RETRO F-1522-006 F-1767-001 3#1 PVC 10 S-1896 FLANGE ADAPTER 11 S.6018 MULLION INTERIOR COVER MULL BAR 1 13 P-3486 MULL BAR CAP NON-IMPACT 14 F-1522-013 3"SLOTTED NEW CONTRUCTION FIN MULL CLIP 15 1 F-1522-006 13"SLOTTED T-CUP z — - 16 F-1767-001 I L-ANGLE T'MULL CLIP,STANDARD < ?. z 0 mujo cowc) 17 F-1767-004L L-ANGLE T'MULL CLIP,FIN,LEFT z uj_'0 <�:Zauj w zOz m_—t .18 F-1767-004R L-ANGLE 3"MULL CLIP,FIN,RIGHT Q :Tc w y 0 CC 3:ca 19 #10 HEX WASHER HEAD TEK SCREW LL Pw z zzm<MWOO 0 0 1­ WOOD SCREW SIZE(910 OR#12).SPECIFIED IN WINDOW UNIT APPROVAL DOCUMENT 01­tC.)< .-CC Q 0 z CL In a. 0Z U)—Z Z) Z 00:� z0ozo 0 1. 0 LL Z 1314­1 12- 17116* < 0 LU p 0— 6 t2") 1 7/1W- 0 Z'6 7116" ,�:t2 5 7116' 0 0 Lu U3 Uj 1/4" LL .00 7116" w z 0-J CO F- a. (L x 0 9 cn 3/16" Lu 1/16' F w cn w DRIP CAP S-1895 (1 15116") 3181, 1 w MULLION INTERIOR I .L� IL F- EL CC COVERS-6018 8 FLANGE ADAPTER S-1896 2 7116• 111116" (17/8') % Vc(TP) 4 /B* 0* AIDREW 13116" 'sfq.......... 318 Na 58201 -P Z I TOP VIEW L� 2 7/16" 1511 42 114') 213/16" 518* s7a— ....... 13/4",.. 1 311_a 3"MULLBAR H-1758 131LF MULLION CLIP S-1897 9/26/2017 ,14 4 7/8' 2114" LUCAS A.TURNER,P.E. F-1522-006 FL PE#58201 RETRO,1 FLANGE CLIP 1239 JABARA AVE. NORTH PORT,FIL 34288 4 7/8 PH.941-380-1574 4. 11 ' SHEET DESCRIPTION: F-1622-013 A CORE,SEND AND BREAK NEW CONSTRUCT.ION FIN INSTALLATION BOM AND EXTRUSIONS TO REMOVE FIN FOR FRAME DRAWN BY: DATE: ATTACHEMENT TO MULL BARRS 04/13/09 DETAIL A TYP.FIN FRAME 3:1 DWG FTE—V.. CWS-430 c scAiE SHEET NOTE:ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. 1:2 4 OF 10