Loading...
HomeMy WebLinkAboutWind Load Calculation PARADISE ,E ERIORS ,;C` 'L "Building Our Quality Reputation, One Customer At A, Time" SCC131150472 Property Information Building Information Owner: PAUL&SHEENAGH KUKLA Wind Zone: 170 MPH. Address: 1107 KINGSWOOD LN Exposure Category: C FORT PIERCE,FL 34982 Minimum Building Dimension: 61 ft. Mean Roof Height: 12 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 32 59 7 37.1 -40.3 - --._..._.. -............... -- ----- -- - - - 2 Int 32 59 7 37.1 -40.3 3 Int 23 35 7 37.8 -41.0 4 End 32 59 7 37.1 -49.3 5 End 25 49 7 37.8 750.6 6 Int 26 49 7 37.8 -41.0 --........- -- --- ---.. - .._.... --- ----..-.... 7 End 25 62 7 37.6 -50.2 8 End 48 52 7 36.4 -47.9 9 End 25 49 7 37.8 -50.6 10 End 52 49 7 36.4 -47.8 _..... -.__.......-----..._....__.-........ --- 11 Int 52 49 7 36.4 -39.6 12 End 25 62 7 37.6 -50.2 13 Int 25 _ 62 7 37.6 -40.8 14 End 25 62 7 37.6 -50.2 15 Int 52 62 7 35.8 -39.0 16 Int 52 62 7 35.8 -39.0 RECEIVED JAN 0 4 2019 -- Pv ric County, Permitting ST. I.0FILE CA-T . Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.61h Edition(2017)Florida Building Code. Page 1 of 1 a • lei ® � • � ® o. A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Comer Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE OPENING (Location) IS THIS A PRODUCT ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW TYPE ACCEPTANCE OPENING SHUTTERS NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF TESTED DIMENSIONS MULLION REQ Y/N SIZE REQ Y/N/NA 1 Int window 7/8"LamilG FL15780.8 55 65 37.1 -40.3 54x76.5 32x59 No No 2 Int Window 7/8"Lam'IG FL15780.8 55 65 37.1 -40.3 54x76.5 32x59 No No 3 Int Window 7/8"LamilG FL15780.8 55 65 37.8 -41.0 54x76.5 2305 No No 4 End Window 7/8"LamilG FL15780.8 55 65 37.1 -49.3 54x76.5 32x59 No No 5 End Window 7/8"LamilG FL15780.8 55 65 37.8 -50.6 54x76.5 25x49 No No 6 Int Window 7/8"Lam" FL15780.8 55 65 37.8 -41.0 54 x 76.5 26x49 No No 7 End Window 7/8"Lami IG FL15780.8 55 65 37.6 -50.2 54.76-5 25x62 No No 8 End Window 7/8"Lami IG FL15780.8 55 65 36.4 -47.9 54 x 76.5 48x52 No No 9 End Window 7/8"LamilG FL15780.8 55 65 37.8 -50.6 54x76.5 25x49 No No 10 End Window 7/8"Lami IG FL 15781.11 55 60 36.4 -47.8 73 x 63 52x49 No No 11 Int Window 7/8"LamilG FL15781.11 55 60 36.4 -39.6 73 x 63 52x49 No No 12 End Window 7/8"Lam'IG FL15780.8 55 65 37.6 -50.2 54.76-5 25x62 No No 13 Int Window 7/8"Lam+IG FL15780.8 55 65 37.6 -40.8 54 x 76.5 25x62 No No 14 End Window 7/8"Lami IG FL15780.8 55 65 37.6 -50.2 54 x 76.5 25x62 No No 15 Int Window 7/8"LamilG FL15780.8 55 65 35.8 -39.0 54.76.5 52x62 YES No 16 Int Window 7/8"LamilG FL15780.8 55 65 35.8 -39.0 54x76.5 52x62 YES No CE1U19 IA41 a) < ST. Lu_e(-0unLY, C I L E 0 P Y