HomeMy WebLinkAboutWind Load Calculation PARADISE ,E
ERIORS
,;C` 'L
"Building Our Quality Reputation,
One Customer At A, Time"
SCC131150472
Property Information Building Information
Owner: PAUL&SHEENAGH KUKLA Wind Zone: 170 MPH.
Address: 1107 KINGSWOOD LN Exposure Category: C
FORT PIERCE,FL 34982 Minimum Building Dimension: 61 ft.
Mean Roof Height: 12 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 32 59 7 37.1 -40.3
- --._..._.. -...............
-- ----- -- - - -
2 Int 32 59 7 37.1 -40.3
3 Int 23 35 7 37.8 -41.0
4 End 32 59 7 37.1 -49.3
5 End 25 49 7 37.8 750.6
6 Int 26 49 7 37.8 -41.0
--........- -- --- ---.. - .._.... --- ----..-....
7 End 25 62 7 37.6 -50.2
8 End 48 52 7 36.4 -47.9
9 End 25 49 7 37.8 -50.6
10 End 52 49 7 36.4 -47.8
_..... -.__.......-----..._....__.-........ ---
11 Int 52 49 7 36.4 -39.6
12 End 25 62 7 37.6 -50.2
13 Int 25 _ 62 7 37.6 -40.8
14 End 25 62 7 37.6 -50.2
15 Int 52 62 7 35.8 -39.0
16 Int 52 62 7 35.8 -39.0
RECEIVED
JAN 0 4 2019
-- Pv
ric County, Permitting
ST. I.0FILE CA-T
.
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.61h Edition(2017)Florida Building Code.
Page 1 of 1
a • lei ® � • � ® o.
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Comer Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE
OPENING (Location) IS THIS A PRODUCT ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW TYPE ACCEPTANCE OPENING SHUTTERS
NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF TESTED DIMENSIONS MULLION REQ Y/N
SIZE REQ Y/N/NA
1 Int window 7/8"LamilG FL15780.8 55 65 37.1 -40.3 54x76.5 32x59 No No
2 Int Window 7/8"Lam'IG FL15780.8 55 65 37.1 -40.3 54x76.5 32x59 No No
3 Int Window 7/8"LamilG FL15780.8 55 65 37.8 -41.0 54x76.5 2305 No No
4 End Window 7/8"LamilG FL15780.8 55 65 37.1 -49.3 54x76.5 32x59 No No
5 End Window 7/8"LamilG FL15780.8 55 65 37.8 -50.6 54x76.5 25x49 No No
6 Int Window 7/8"Lam"
FL15780.8 55 65 37.8 -41.0 54 x 76.5 26x49 No No
7 End Window 7/8"Lami IG FL15780.8 55 65 37.6 -50.2 54.76-5 25x62 No No
8 End Window 7/8"Lami IG FL15780.8 55 65 36.4 -47.9 54 x 76.5 48x52 No No
9 End Window 7/8"LamilG FL15780.8 55 65 37.8 -50.6 54x76.5 25x49 No No
10 End Window 7/8"Lami IG FL 15781.11 55 60 36.4 -47.8 73 x 63 52x49 No No
11 Int Window 7/8"LamilG FL15781.11 55 60 36.4 -39.6 73 x 63 52x49 No No
12 End Window 7/8"Lam'IG FL15780.8 55 65 37.6 -50.2 54.76-5 25x62 No No
13 Int Window 7/8"Lam+IG FL15780.8 55 65 37.6 -40.8 54 x 76.5 25x62 No No
14 End Window 7/8"Lami IG FL15780.8 55 65 37.6 -50.2 54 x 76.5 25x62 No No
15 Int Window 7/8"LamilG FL15780.8 55 65 35.8 -39.0 54.76.5 52x62 YES No
16 Int Window 7/8"LamilG FL15780.8 55 65 35.8 -39.0 54x76.5 52x62 YES No
CE1U19
IA41 a) <
ST. Lu_e(-0unLY, C