HomeMy WebLinkAboutProduct Approval Florida Building Code Online
'', li
SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts I Publications F'Contact Us SCIS Site Map' Links Search !
Florida
t. ro
,Product Approval
iR USER:Public User
SF.r,xYtanr3x•r+
Product_Approval Menu>Application Detail
FL# FL15780-R8
Application Type Revision
Code Version 2017
£h i
t Application Status Approved
i
RECEIVE®
Comments
Archivedek
o JAN 0 4 2019
Product Manufacturer Soft-Lite LLC ST. Lucie County, Permitting
Address/Phone/Email 10250 Philipp Parkway
Streetsboro,OH 44241
(330)528-1136
'5 PLangan@soft-lite.com
Authorized Signature Vivian Wright
rickw@rwbldgconsultants.com
� axe
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
r fi x�i a
77
Category Windows
° Subcategory Double Hung
L Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
. Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the Lyndon F.Schmidt, P.E.
Evaluation Report
rr Florida License PE-43409
Quality Assurance Entity Farabaugh Engineering and Testing,Inc
Quality Assurance Contract Expiration Date 12/31/2018
+ Validated By Ryan J. King, P.E.
U:
Validation Checklist- Hardcopy Received
Certificate of Independence FLIS780 R8 COI (b)Certificate of Independence.pdf
n
�Pw� Referenced Standard and Year(of Standard) Standard Year
AAMA/WDMA/CSA101/I.S.2/A440 2008
AAMA/W DMA/CSA101/I.S.2/A440 2011
AAMA/WDMA/CSA101/I.S.2/A440 2005
ZXi ASTM E1886 2005
- ASTM E1996 2006
ASTM E1996 2009
TAS 201 202, 203 1994
https://tloridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgt3elSAInEOW6yPiCnocELk3nHvFWLJoQah8YcpuwDiUg%3d%3d[9/7/2018 8:11:38 AM]
Florida Building Code Online
Equivalence of Product Standards
�—;° Certified By
v
fir;,
.
Sections from the Code
t wrx
F
X ,' Product Approval Method� Method 1 Option D
x x '
Date Submitted 06/11/2018
` Date Validated 06/13/2018
Date Pending FBC Approval 06/18/2018
Date Approved 08/15/2018
g'a U
Summ of..Products -7777777---,-,—.,7,
q^. X ,zg• , w,:.u6m �.........:.-.:_.
ModelNumber,or.Name De
, scription;
' 15780.1 a. "Imperial LS 131-112" Double Hung Extruded PVC Double Hung Window-(X/X Configuration)
5' I Window
Limits of Use Installation Instructions
4 4 Approved for use in HVHZ: No FL15780 R8 II (,a) Inst 15780.1. dmf
r
Approved for use•outside HVHZ:Yes Verified BY: Lyndon ndon F. Schmidt, P.E.43409
�,��
a ro Impact Resistant: No Created by Independent Third Party: Yes
xis _`" Design Pressure: N/A Evaluation Reports
Other:See INST 15780.1 for Design Pressure Ratings,any FL15780 R8 AE (a) Eval 15780.1.pdf
additional use limitations, installation instructions and product Created by Independent Third Party:Yes
particulars.
ks 157802` b:"5400 dH54(65405) Double' Extruded`PVC Double Hung;Window.-',(X%X`Configuration)
Hung Window' .
Limits of.Use -'Installation Instructions
Approved for us in HVHZ: No FL15780 R8 II (a)'Inst 15780.2.pdf-
Approved for use outside HVHZ Yes . , Verified By: Lyndon F. Schmidt,.P.E. 43409
Impact.Resistant:,No Created by Independent Third Party: Yes.
Design Pressure: N/A - Evaluation Reports>,.
{ , Other,:,See INST 15780.2 for DesigmPressure Ratings any FL15780 R8 AE (a)�Eval 15780.2.pdf.'- ,
` additional use•limitations, installation"instructions ander"oduct" Created by Independent Th rd Party:Yes
particulars.
'40 �' " ; 15780.3 c. "5400 DH54(G5405)"Double Extruded PVC Double Hung Window-(X/X Configuration)
Hung Window
Limits of Use Installation Instructions
„; Approved for use in HVHZ:Yes FL15780 R8 II (a)Inst 15780.3.pdf
" Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt P.E.43409
a Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
s; Other:See INST 15780.3 for Design Pressure Ratings, any FLIS780 R8 AE (b) Eva] 15780.3.pdf
&° „ �1x` additional use limitations, installation instructions and product Created by Independent Third Party: Yes� particulars.
'
*
15780.4' d'. "5300-DH53.(G5305)"Double-, Extruded PVC Double Hung Window-(X/X�Configu ration)
ks,1 Hung Window
Limits=of'UsInstallation-
111-11 T
F lation Instructions
y Approved.for use l,n HVHZ:No a FL15780 R8_II (a)Inst 15780.4 pdf ,"
" Approved for use outside HVHZ gYes Verifietl By::Lyndon F.wSchmidt, P E.,43409
"Im act.Resistant: No,*, Created b Independent Third Pa Yes
( ' 1 ; P, Y P Party:
Design Pressured N/A Evaluation Reports
Other:See INST 15780.4 for Design Pressure Ratings,any FL15780 R8 AE (a) Evai 15780.4.ndf
3
additional use limitations, installation instructions and'product Created by Independent Third Party: Yes
particulars.
"
15780.5 e. "5300 DH53(G5305)" Double Extruded PVC Double Hung Window- (X/X Configuration)
q
Hung Window
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15780 R8 II (a)Inst 15780.5.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409
https://floridabuilding.org/pr/pr_app_tl.aspx7param=wGEVXQwtDgt3elSAInEOW6yPiCnocELk3nHvFWLJoQah8YcpuwDiUg%3d%3d(9/7/2018 8:11:38 AM]
Florida Building Code Online
Impact Resistant:Yes Created by Independent Third Party: Yes
° Design Pressure: N/A Evaluation Reports
f° Other:See INST 15780.5 for Design Pressure Ratings,any FL15780 RB AE (b) Eva[ 15780.1;.12df
y' additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
jyy �
15780 6 f. Series'Barcelona!`Model'DH30I Extrucled,PVC,Double Hung°"Impact"Window Missile Level'"C"
(X/X,Confguratlon) :.
t Limits of Use Installation Instructltns .w r
" Approved for use„in HVHZ: No FLI57$0 R8 11"(a)Inst 15780:6
Approved.'for,use outside HVHZ Y,es Verified By.' Lyndon F..Schmidt, P E 43409
:Impact Resistant;Yes -Created by IndependentThird.Porty ,Yes ,
gl % Design Pressure: N/A Evaluation Reports
Other:,See INST 15780.6 for Design.:Pressure"Ratings,any FLiS780 R8 AE (b) Eval 15780 6,odf
"
additional'Use limitations,'installation instructions and product Created by`3ndependentThird Party:Yes
-particulars.
15780.7 g. Series"Barcelona”Models"DH30I" Extruded PVC Double Hung"Impact"Window, Missile Level "D"
x &"DH30PI" -(X/X Configuration)
Limits of Use Installation Instructions
" Approved for use in HVHZ: No FL15780 R8 II (a) Inst 15780J.pdf
*, -W Approved w ;.
�r � Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409
vw
[ i4 , Impact Resistant:Yes Created by Independent Third Party: Yes
I Y, Design Pressure: N/A Evaluation Reports
� Other:See INST 15780.7 for Design Pressure Ratings,any FL15780 R8 AE (b) Eva[ 15780.7.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
�� ;➢f
r: 15780 8 •- h. Senes'Barcelona" Models'"DH30I" Extruded PVC Double Hung "Impact"Window, High Velocity
&"DH30PI" Hurricane`Zone-.(X/X Configuration)
' # Limits of'UseInstallation In"structio,ns
Approved for use in HVHZ:Yes FL15780-R8 II (,a)-Inst 15780.8 pdf
(,
Approved"foruse outsld0HVHZ Yes Verified,By:'Lyndon,F.,Schmidt, P E.43409
' Impact Resistant Yes Created•by'Independent Third PartyYes
� 4' Design Pre"ssure N/A >< ,h � Evaluation"Reports
4 ;1 Other See°INST 15780.8 for Design Pressure�Ratingsi any FL15780 RS AE (J� Eval 157808 pdf r
( ` additional use limitations; installatioWinstructions and product Created- y Independent Third Party Yes
particulars.,
1 15780.9 i. Senes"Barcelona"Models"DH30" Extruded PVC Double Hung"Non-Impact"Window-(X/X
^` &"DH30P" Configuration)
Limits of Use Installation Instructions
.� Approved for use in HVHZ: No FL15780 R8 II (b)Inst 15780.9.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409
F Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
44 '' Other:See INST 15780.9 for Design Pressure Ratings, any FL15780 R8 AE (b) Eval 15780.9.pdf
# { NF
f t additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
r , Contact Us::_2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
}�'a The State of Florida is an AA/EEO employer,Copyright 2007-2013 State of Florida.::Privacv Statement::Accessibility Statement::Refund Statement
" Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
#r mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please dick here.
y _
Product Approval Accepts:
s jai
Credit Card
Safe
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgt3elSAInEOW6yPiCnocELk3nHvFWLJoQah8YcpuwDiUg%3d%3d[9/7/2018 8:11:38 AMI
R W R W Building Consultants, Inc.
B Consulting and Engineering Services for the Building Industry
C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197
Florida Board of Professional Engineers Certificate of Authorization No.9813
Product Sub Category Manufacturer Product Name
Category
Soft-Lite LLC "Barcelona"
Windows Double Hung 10250 Philipp Parkway Model"DH301"&"DH30PI"
Streetsboro;OH 44241 Double Hung Window
(330)528-3400 "Impact"
Scope: Product Evaluation report issued by R;W Building Consultants,Inc.&Lyndon F.Schmidt;.P.E.(System ID#_1998)for Soft-
Lite.LLC.,based on:Rule Chapter No:61 G20-3;Method 1 D of the State of Florida Product Approval,Department of
Business;&.Professional Regulation.
RW Building Consultants and.Lyndon,F.Schmidt,P:E.dont have nor will acquire,financial interest in the company
manufacturing or distributing the,product..or in any other entity involved in the.approval process of the,product named herein.
Limitations:
1. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code(FBC)structural requirements
including the"High Velocity Hurricane Zone".
2. Product anchors shall be as.listed and spaced as shown on.details.Anchor embedment to base material shall be beyond wall dressing
or stucco.
3. When used in"HVHZ",this product complies with Section 1626 of the FBC and does not require an impact resistant covering.
4. For 2x stud framing construction,anchoring of these:units.shall be the same as that shown for 2x buck masonry construction.
5. Site conditions that deviate from the details of drawing FL-15780.8 require further engineering analysis by a licensed
engineer or registered architect.
6. This product meets the water infiltration requirements for"HVHZ".
7. See drawing FL-15780.8 for size and design pressure limitations.
Supporting Documen s;
1. Test.Report No. Test:Standard Testing Laboratory Signed•by,
TEL 0300.1734- TAS 201,202.&20344 Testing Evaluation.Lab., Inc. Lyndon F.Schmidt;P.E:
2. Miami Dade NOA, Materials Testing.
17-0712:04 Saflexo PVB Interlayer(Eastman Chemical Company)
15-0528.13 PVC Extrusions.(Vision;,Extrusions Ltd.)
3. Drawing No. Prepared by Signed,&•Sealed by
No.FL-15780.8 RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt, P.E.
ty��4g9i$ffB669g&
4 ,Sealed by
Buck Anchoring. RW Building Calculations Prepared Cosultants,Inc.(CA#9813),�g��S� �peeao°°.y , �p Lyndon ned F.Schmidt,P.E.
ASTM E1300 Glass Load Lyndon F.Schmidt, P.E. ��w ,��
5. Quality Assurance No 43409 °o
Certificate of Participation issued by Farabaugh Engineering.and Q o m
Testing, Inc,certifying that Soft-Lite.LLC•is manufacturing,products7-1
within a quality assurance program that complies with ISO/IEC _ q
17020 and Guide 53. 0.
ST '"�T
40
�O
"t;8e(0�g � p0�00 Lyndon F.Schmidt,P.E.
FL PE No.43409
10/11/2017
Sheet 1 of 1
.`````��
R v :vv.
r"iP
0 4Q
0
U_ a
Cl)*-. o LL
.� Z A o
.........
10250 Philipp ParkwaBriy
quality to light, i�i' 'rEl'-wilidows
r "P, o omi
Streelsboro,Ohio 44241 N a z z
SEE CHART FOR� �SEE.CHART FOR� £ m a do
,ll!
v a in � =a
FRAMESIZES FRAME SIZES 4 4
Model "DH301 and "DH30P1" E oz
DOUBLE HUNG WINDOW
"imp acrr
Z
LL _ x o
J ¢�
GENERAL NOTES
0 2 ¢z
1. This product has been evaluated and is in compliance with the 6th Edition(2017) o a
Florida Building Code(FBC)structuraLrequirements including the"High Velocity / �/ o) ��
Hurricane Zone"(HVHZ). w a
a a
N
2. Product anchors shall be as fisted and,spaced as shown on details.Anchor X X m
embedment to base material shall be beyond wall dressing or stucco.
o
3. When used in the"HVHT'this product complies with,Section 1626 of the FBC and
does not require an impact resistant covering.
4. For 2x stud framing construction,anchoring of these units shall be the same as that o
shown for 2x buck masonry construction Ln
Model"DH30F' Model"DH30PI" aj
5. Site conditions that deviate from the details of this dravdng require further
engineering.analysis by a licensed engineer or registered architect.
S
a 6. This product meets the water infiltration requirements for the"HVHT'. m
a
TABLEOFCONTENTS MAX MAX D�SfGNPRESSURE(PS0 m
SHEENDESCRIPTION _ MODEL n fR 4M� D i 0 C'p r Az.
g I Typical elevations,design pressures and general notes DIMEN�ION,w ,, DIMENSION POSIi1VE NEGATIVE, ,
w,E 4/14/17 z
2 Horizontal cross sections 'n
E 3 Horizontal cross sections
"DH301" 54.0"X 76.5" 46.25"x33.875' G1 +55.0 -65.0 s=* N.T.S.
4 Vertical cross sections aec,sr' JK m
5 Buck and frame anchoring "DH3011,I" 54.0"X 76X 46.25"x 33.50" G1 +55.0 -65.0 !FS 3
z 6 Components
7 ComBillponents owFL 15
FL-15780.8 0
0 8 of mater als and glar ng detail SHS 7 o 8
Hardware Notes:
1. Lockomeachjamb. �44 ks(2)located on lock rail
lac4 EMB4(TYP.) m
W M
<__4
SEE DETAIL I SEE ANCHORING SHEET ; z° 5 Al!0-zCom
/ Amro
a
24 33 28 �''•..
INTERIOR
8 G1 INTERIOR '�i� `���� N 3 n_
X 24 UN°°z°
/ �v o ■z°0
2to Sm °cw
a m°°n 56tm
mdan
Vv � 4
av
E oz°
❑ 13 9 FIT-
0 o3d
X 25
1 ❑
3 p
EXTERIOREXTERIOR
❑
z
\y/ E 1 �j 3 r `En
4 4 2 HORIZONTAL CROSS SECTION DETAIL 1 N o
2 Shown Direct to Masonry
E 8
a a
>-
C
C A m
24 SEE DETAIL 1 1-1/4"MIN. C SEE DETAIL 1
M EMB.(TYP.)
33 28 8 G1 24 33 28 8 G1
INTERIOR INTERIOR z
a I C= Ln
G
• '1 oP ev
n ❑ 13 9 ❑ 13 9 z
Z
LL° EXTERIOR K ° EXTERIOR El
c
3 1-1/47MIN. p DAA 4/14 17 i
EMB.(TYP.) 1 scuE N.T.S.
E
Bwc.BY. JK m
CHK BY: LFS 3
1 HORIZONTAL CROSS SECTION 1 �31 HORIZONTAL CROSS SECTION DPA- N0.:
2 2X Buck Construction 2 Shown w/1 X Buck
FL-15780.8 a
l-+• SHEET 2 OF 8 w
u
d
R:\Olents\Soft•LRe Pemlanent\A-Florida Product Approvals\FL-15780 Double Hung\C-Drawings\FL-15780(2017)(FWS780.68.dwg,3
A
�A A•
0n
o;j
'O v
N
N
CA �+
n A
°z DA
13
❑ w
wN _
o M
W Go
0 —
p �N
0 3 n
D
•O � D �a
Ca o ti ❑
QA 0
lO Q W
A s IN Q
A m �
Z w 0
•o
w �
I0
I0
T
N=
X
O n ❑
N '
N
n — ^
Z W FR
O
D_
W
O A
A O `1111111111////
le-ScH�yi�
�- No.43409
In o o Q PRODUCT. Documents Pp.,6d 8y:'
?; Lyndon F. Schmidt �� ��0�•'�• �`�
i�
SOFT-L1TE WINDOWS ''••......•• 6
P.E. No. 43409
W All ��`�
co .4 {' PART OR ASSEMBLY: GJ���/BUILDING CONSULTANTS, INC.
�m o 5 - - HORIZONTAL P.O. Box 230. Valrico. FL 33595
m NO DATE BY CROSS SECTIONS Phone No.: 813.859.9197
REVISIONS FBPE C.A. No. 9813
0 201 7 R.W.91J1--0.... ..to Iwc.
R:\CIIents\SGR-Ute Penanent\A-Florida Produd Approvals\FL-15780 Double Hung\C-DraWings\FL-15780(2017)\FL-15780.6-8.dwg,4
1-1/4"MIN. 1-1/4"MIN.
EMB,(TYP.) EMB.(TYP.)
0 N m IAN w m
.o w .o w n
C-N Ja
0
n dD 0 n
N =VN! U
-L
O
O N A O .. M
Z D i Z I° I
S T
M
O° 1-1/4"MIN.
EMB.(TYP.)
P
A N > m
.o w
A W 0
A A 1.96"
n
OR n C'° o
'02 0o 0 O q
a_ H
y=Al I O rn O
O rn
A bl A
Z I
Z W
IA ....
1-1/4'MIN.
EMB.(TYP.)
N
M m
m
N
w N r„ A O•
S� •o
Co
O N 196"
A N
C ❑
❑ -o
w �
C
0 nn
0 n o r
O O O C3
H I
� � N
1-1/4"MIN. A
EMB.(TYP.) 1.9 ' / No.43409
5T' 1.957
Q PRODUCT: Deeumente Prepared41y, v, 01AMW
SOFT—UTE WIDOWS Lyndon F. Schmidt ��i� �'•.!LORIDR
WINDG
43409
m' y 4` PART OR ASSEMBLY: G��7��BUILDING CONSULTANTS, INC.
p L, x ln. J1�U1/ P.O. Box 230, Valrieo, FL 33595
I� bo BY CROSSSECTIONSV Phone No.: 813.659
NO DATE .9197
REVISIONS FBPE C.A. No, 9813 -
®2C17 R.W.BUILDING CDNGULTANtG INC.
%
............
-n
%
xi
PYP.) 10.5-O.C.(TYP.)
CL:
6-(TY�P) A z
C-3 6
C
% >
.7- z11
0 N
o Q3 o
11 z
0
z
z.
2X BUCK F N rA m'.w
NJ b 2W =1 6 oo.
TYP. r� 07 D :.E
SASH IXBUCK G C3 a.
DIRECT TO LZ
2X BUCK H .6
MASONRY z
BUCK < FRAME�� HEAD&JAMBS g v Lj
ITYP-) A SO:
MEETING
2X BUCK M
MASONRY
OPENING IXBUCK K
MASONRY DIRECT TO 3 La
OPENING], D :z
SASH MASONRY m
THROUGH TILT
LATCH BLOCK fl
o
o
BUCKANCHORING FRAMEANCHORING
z(n
0
Vi
CONCRETE ANCHOR NOTES.*
1.concrete anchor locations at the comers maybe adjusted to mainfain the min.
edge distance to mortar joints.
2.Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to
maintain the min.edge distance to mortar joints,additional concrete anchors
may be required to ensure the"MAX.ON CENTER"dimension are not exceeded.
3. Concrete anchor table:
....
.......... .. ...............I........................CLEARANCE. z
.. ..
...........ANCHOR.......
........... ..............
z Q
TO ADJACENTiVPE1 11 8
...... .............. . 0
..............................
mm
ITW /47 2" 4/14/17
TAPCOV scAm N.T.S.
ELCOMO.Mi. JK
4- CHV-BY-- LFS
WOOD SCREW INSTALLATION NOTES: DRAWING NO.: rc
1.Maintain a minimum 5/8"edge distance,I"end distance,&I"o.c.spacing of FL—15780.8
wood screws to prevent the splitting of wood.
ISHEET_5_OF_jL 0
R:\Olents\Soft-Ute Permanent\A-Florida Product Approvals\FL-15780 Double Hung\C-Drawings\FL-15780(2017)\FL-15780.6.8.dwg,6
N � _
0
V a
O W y
0
z
h
m
� 0.66"
It
1.77'—n
C noo 1
O � U� w
0.065" 1.63"
m
2.87"'
0.95' 1.5'
WTT
Tim
L 0;0
0.27'--1
0.86"
A_
m o
iv o o
o y? 0.09" �? a
m 1
T
I! s '°
0.06S'
1.05'
00
1.44„
0.39" 0.32"
N A 0.64"
A
4o.09. 9 � n �
- m x
m
>
1.os" N
0a7"-� ��• sCH
0.94" /
7 No.43409
T g PRODUCT: Documents Prepared By:
�pgtDf•.:'��
SOFT—LITE WINDOWS Lyndon
nd n F43409 Schmidt ��jei.
r- i S •......-�
I
�///71�j lAltlll\\
PART OR ASSEMBLY: //�� BUILDING CONSULTANTS. INC.
(n _. r!v�P.O. Box 230, Valrlco• FL 33595
C)I� Co N v NO DATE BY COMPONENTS Phone No.: 813.659.9197
REVISIONS FBPE C.A. No. 9813 ,
02017 R.W.BUILDING Cors UL-NIe IND.
R:\Olents\Soft-Lite Penanent\A-Rorida Product Appmals\FL-15780 Double Hung\C-Drawings\FL-15780(2017)\FL-15780.8-8.dwg,7
2.87"
o
� O
� � o
a
o
0
m ❑
1.96"
v
V �
R �
� 1
0
T a
0
0
1.21" in
--
T_ w
w
�s
m w
Y y p�q.
vJ IV
clo
2.39"
121"
1.OT'—►I
a
� _ o
0 0.09' too
—T ce �t
1151Illitt,
1.96„ SCHM��rirr
�� v:uc�NaF . �•
No.43409 �
�ZRr �•C
PRODUCT: Decumente Propared By:i
{, SOFT—LITE WINDOWS Lyndon NoF43Schmidt ;irrvft
I14 G o Z
V GA BUILDING CONSULTANTS,, INC.
y PART OR ASSEMBLY: J�
I� 00 ti NO DATE BY COMPONENTS Phone No.:30.Valrico. FL 813.659.9197 33595
REVISIONS FBPE C.A. No. 9813
®2017 R.W.BUILDING CONGUL-NIA INC.
o`%����
BILL OF MATERIALS ``O� :.• !)/j�., n
REM 0 MATERIAL -410.0
A 1X BUCK SG>=0.42 WOOD ==';`af' o3Q_Z"�
B 2X BUCK SG>=0.42 WOOD =a.-; �,
Z '•04 m
C 1/4"MAX.SHIM SPACE o
mio
D 1/4"X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL %�: =N M
MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI ,• ~
E
301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE , '���/LLL Iltt ���`` o o m z°
•;
F #8-15 X 2 TRUSS HEAD SMS(1-3/8"MIN.EMBEDMENT) STEEL U Na m x Z
G IX X 2-3/4"HWH ELCO OR ITW CONCRETE SCREW STEEL \ E 7 G
H 1/4"X 2-1/4"HWH ELCO OR ITW CONCRETE SCREW STEEL \, a ya o o m
K 1N X 3-1/4"PFH ELCO OR ITW CONCRETE SCREW STEEL LL
"�� a m a o.4
g
M #10 X 2-3/4"PPH WS(1,3/8"MIN.EMBEDMENT) STEEL E a Z
1 FRAME' PVC o gra
2 HEAD* PVC
3 WEEP HOLE COVER* PVC
4 SILL ADAPTER' PVC
5 TOP UFT HANDLE` PVC 3
6 KEEPER RAIL' PVC o H
7 LOCK RAIL* PVC 3 mac,
8 PLAIN STILE* PVC
9 GLAZING BEAD' PVC 5/B"GLASS BITE DOW 240D SAS N o�
10 BOTTOM LIFT RAIL' PVC 7/8"THICK '
11 REINFORCEMENT(6065-T5 ALUM) ALUM. 1/8"ANNEALED Vn
o12 REINFORCEMENT(6065-T5 ALUM) ALUM.13 REINFORCEMENT(6065-T5 ALUM) ALUM. � 0.09(7'SAFLEX PVB INTERLAYER a
14 HEAD POCKET INSERT' PVC
15 SLOPED INSERT* PVC 1/fi"ANNEALED m
3 16 SLOPED SILL` PVC
0 20 LOCK - - AIR SPACE
21 LOCK KEEPER - ao
24 TILT LATCH BLOCK - 1/8"ANNEALED OR TEMPERED GLASS*
n
25 TILT LATCH STEEL INTERCEPT SPACER
26 #8 X 1"PFH TEK STEEL o
27 #6 X 1"PFH TEK STEEL GT GLAZING DEFAfL Ln
28 WEATHERSTRIP(187-270 TRI-FIN)
29 BULBSEAL -
" 30 BULBSEAL
a 31 PIVOT BAR STEEL "HVHT'GLAZING NOTES: z
32 #7 X 3/4"PFH TEK STEEL 1.GLAZING>36'WIDE REQUIRES TWO)2)SETTING BLOCKS CONFORMING TO FBC SECTION 2411.3.3.1 m
2.*TEMPERED GLASS IS REQUIRED FOR EXTERIOR GLASS GREATER THAN 30 FEET ABOVE GROUND. r a
33 BALANCER BRACKET o
•THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARETO BE PRODUCED BY
m
EXTRUDERS LICENSEES IN"AAMA CERTIFICATIONS PROGRAMS FOR RIGID PVC EXTRUSIONS". z
O o
Z
5 DATE 4/14/17 =
scuE a N.T.S. �
E
owG.BY: JK m
cHK.ew. LFS 3
•j DRAWING NO.:
r
N FL-15780.8 0
N
SHEET 8 OF 8
V