HomeMy WebLinkAboutProduct Approval (2) Florida Building Code Online
-:r W .. ... x Ts` .,• ,..:� ,: "'_... Z� ..,.g�,,.._;tr•. ,a:c°`a..Ma ,; "` •y _ _
� x
BCIS Home Login I User Registration Hot Topics ) Submit Surcharge Stats&Facts Publications + Contact Us BCIS Site Mapt Links Search`i
Florida
Product Approval
"r .USER:Public User
nt"
Product Aonroval Menu>Application Detail
FL# FL15781-R8
Application Type Revision
n
Code Version 2017 RECEIVED
A r F>« Application Status Approved
Y. X f wafl:
JAN 0 4 2019
Z" Comments
S = � a '�` ST. Lucie Count , Permitting
Archived p Y 9
Product Manufacturer Soft-Lite LLC
Address/Phone/Email 10250 Philipp Parkway
r Streetsboro OH 44241
-. (330)528-1136
x PLangan@soft-lite.com
tiir ,
=� n. Authorized Signature Vivian Wright
N rickw@rwbldgconsultants.com
{„ Technical Representative
}
� Address/Phone/Email
�j o �
f�
Quality Assurance Representative
Address/Phone/Email
0','7t'
Category Windof ',. Subcategory
Horizontal Slider
gp Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
1' ; e ri �� ❑ Evaluation Report- Hardcopy Received
Lyndon F.Schmidt, P.E.Florida Engineer or Architect Name who developed the L
g P Y
Evaluation Report
Florida License PE-43409
Quality Assurance Entity Farabaugh Engineering and Testing,Inc
;. Quality Assurance Contract Expiration Date 12/31/2018
*£: Validated By Ryan J. King, P.E.
ID
g
Validation Checklist-Hardcopy Received
' Certificate of Independence FL15781 R8 C01 (b)Certificateof indeoendence.odf
ray �
1." Referenced Standard and Year(of Standard) Standard Year
AAMA/WDMA/CSA101/I.S.2/A440 2011
AAMA/WDMA/CSA101/I.S.2/A440 2008
ASTM E1300 2004
yASTM E1886 2005
�..s°
ASTM E1996' 2006
ASTM E1996 2009
TAS 201, 202, 203 1994
hitps://(loridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgt3e I SAInEO W 9Taf7MFDxJQgCR4F8K9N%2fsDYcoUiUZ2mQ%3 d/3d[9/7/2018 8:19:28 AM]
Florida Building Code Online
Equivalence of Product Standards
Certified By
Sections from the Code
Eat
Product Approval Method Method 1 Option D
c "
v Date Submitted 02/13/2018
F
Date Validated 02/14/2018
Date Pending FBC Approval 02/22/2018
Date Approved 04/10/2018
Summary of Product77
FL# Model,Number or:Name { Description,
# _ 15781.1 a. "Imperial LS DSL12" Double Slider Extruded PVC Double Horizontal Sliding Window-(XX
y Window Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No _EL15781 R8 II (a)Inst 15781.1.pdf
t= Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409
r Impact Resistant: No Created by Independent Third Party: Yes
a Design Pressure: N/A Evaluation Reports
Other:See INST 15781.1 for Design Pressure Ratings,any FL15781 R8 AE (oval 15781.1.odf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
my' particulars.
m '
15781.2 ' 115. 'Imperial LS'TSL12"'Triple Slider Extruded PVC Triple Horizontal Sliding Window- (XOX
y" P:: Window, Configuration)
(�� r Limits'of-Use Installation_Instructions
-Approved for use in HVHZ: No FL15781 R8 'II (a)Inst 15781.2.pdf_
T Approved for'use-outside HVHZ:Yes Verified,By. Lyndon,F. Schmidt, P.E.,43409
Impact'Resistant: No Created by Independent Third Party: Yes
y Design Pressure: N/A - Evaluation-Reports
c .-Other:See INST;15781.2for Design-Pressure Ratings,any FL15781 R8 AE (a) Eva[ 15781:2.dmf
additional use.limitations, installation instructions and product Created by Independent.Third.Party:.Yes
{ � particulars.
15781.3 c. "5300 DSL53(G5352)" Double Extruded PVC Double Horizontal Sliding Window-(XX
Slider Window Configuration)
4, Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15781 R8 II (b)Inst 15781.3. df
' ,.,i k Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
w lh Other:See INST 15781.3 for Design Pressure Ratings, any FL15781 R8 AE (a) Eval 15781..3. dmf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars. I
g 15781.4 d. "5300 DSL53-;(G5352)"Double Extruded-PVC Double HorizontalSliding-Window-(XX
SI[der W(nd'8 Configuration)`
Limits of UseInstallation'Instructions
Approved foruse No FLI5781 R8.dI (b)Inst 15781.4 pdf
Approved:for use outside'HVHZ Yes Verified By:..Lyndoq F:,Schmi'dt, P.E. 43409,
Irgpact Resrstantp Yes Created by Independent Third Party:Yes:
s `Desig,n Pressure..N/A Evaluation Reports:
Other:See INST 15781:4 for Design'Pressure Ratings;any FL•15781 R8 AE (a) Eyal 15781.4.pdf>
additional use limitations installation instructions and product Created b Independent Third Pa Yes
� p Y P rtY�
particulars.
15781.5 e. "5400 SSL54(G5402)"Single Extruded PVC Single Horizontal Sliding Window- (OX or XO
.x Slider Window Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15781 R8 II (b)Inst 15781.5.12df
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409
https://floridabuilding.org/pr/pr_app_dtl.aspx?pamm=wGEVXQwtDqt3elSA1nEOW9Taf1MFDxJQgCR4F8K9N%2fsDYeoUiUZ2mQ%"3d%3d[9/7/2018 8:19:28 AM]
Florida Building Code Online
R ; Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.5 for Design Pressure Ratings, any FL15781 R8 AE (a)Eval 15781.5.odf
a � additional use limitations, installation instructions and product Created by Independent Third Party:Yes
g` particulars.
f 7,-
. a
1-5781;6 f. 5400,S$L54.(=G5402) Single : Extruded'PVC Single Horizontal Sliding Window-(OX or XO
h
Slider Window Configuration)
Liits of Use
mInstallation Instructions
Approved for use�m HVHZ Yes FL15781 R8 'II (b)Inst 15783.6.pdf
' Approved for useoutside HVHZYes Verified By: Lyndon F,Schmidt,P.E.43409
Impact Resistant:Yes. Created;by Independent Third Party: Yes '
'Design'Pressure:;N/A
. Evaluation Reports
e Other:See INST 15781.6 for lies!gn'Pressure Ratings; any FL15781 R8 AE (a)Eval 15781.6.pdf
additional use limitations, installation;instructions and product, Created by,lndependeritThird Party: Yes
particulars.
15781.7 g. "5400 TSLF54"Triple Slider Extruded PVC Triple Horizontal Sliding Window- (XOX
Window Configuration)
h q# Limits of Use Installation Instructions
Approved for use in HVHZ: No FLIS781 R8 II_(a) Inst 15781.7.pdf
§ Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409
` Impact Resistant:Yes Created by Independent Third Party:Yes
=is
x Design Pressure: N/A Evaluation Reports
Other:See INST 15781.7 for Design Pressure Ratings,any FL15781 R8 AE (a) Eval 15781.7.pdf
additional use limitations, installation instructions and product Created by Independent Third Party:Yes
particulars.
C" 15781 8„ h."5400 TSLF54"Triple Slider = Extruded PVC Triple Horizontal Sliding Window- XOX
P P 9
11Vindow Configuration)
4 Limns-of Use Installation Instructions
Approved for use.in.HVHZ:Yes . FL15781 R8 II (a)'Inst 15781.8.pdf
,a Approved for use outside HVHZ Yes Verified:By: Lyndon F:,,'Schmidt, P.E.;43409"
y 3mpact`Resistant kYes Created"b 'Inde endent Third Part Yes,,-,
v Y. p Y
y f� Design Pressure,N/A �. EvaluationReports `?
Other:�See INST 15781.8 for DesigglPressure Ratings,any,'" FLIS781 R8`AE (a)EVaI"15781 8 pdf
additional use limitations, installation iristructions and product Created by Independent Third Party:Yes
n
particulars.
Ml-
F 15781.9 i.Series"Barcelona" Model"SSL30I" Extruded PVC Horizontal Sliding"Impact"Window, Missile Level
# a
"C"Excludes Wind Zone 3 and 4(XO or OX Conflgurations)
Limits of Use Installation Instructions
s•' Approved for use in HVHZ: No _FLIS781 R8 II (b)Inst 15781.9.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
'r Design Pressure: N/A Evaluation Reports
sde' Other:See INST 15781.9 for Design Pressure Ratings, any _FL15781. R8 AE (a) Eval 15781.9.odf
{ additional use limitations, installation instructions and product Created by Independent Third Party: Yes
4r,37,;io NO
mt
* = particulars.
j. Series 'Barcelona" Model "SSL30I" Extrude&PVCHorizontal Sliding "Impact"Window, Missile Level
H 15781.10
".D."Includes Wind Zone 4(XO or OX,Configura'tions)
Limits ofWe Installation Instructions
+ � Approved for use'`in HVHZ: No �' FL15781'R8 II O�lnst 1=5781.10 pdf• ;
za H
Approved for use outside'HVHZ.Yes: "Verified By: Lyndon F. Schmidt, P.E.43409-
Impact'Resistant:Yes Created=by Independent'Third Party:Yes'
{€ 1r > Design Pressure: N/A Evaluation Reports
` Other:.See•INST 15781.10,for Design-Pressure'Ratings,'any FLi5781 R8 AE (a) Eval 15781.10.pdf
additional use limitations*installation instructions and;product Created;by Independent Third Party: Yes
N
s � =particulars.
15781.11 k.Series"Barcelona"Model "SSL30I" Extruded PVC Horizontal Sliding"Impact"Window, High
Velocity Hurricane Zone Large Missile(XO or OX
Configurations)
B. Limits of Use Installation Instructions
" Approved for use in HVHZ:Yes FL15781 R8 II (b)Inst 15781.11.pdf
....k
Approved for use outside HVHZ:Yes Verified Y B Lyndon ndon F. Schmidt, P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
' Design Pressure: N/A Evaluation Reports
Other:See INST 15781.11 for Design Pressure Ratings,any FL15781 R8 AE (a) Eval 15781.11.12df
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
A
k
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgt3eiSA1nEOW9Taf7MFDx1QgCR4F8K9N%2fsDYeoUiUZ2mQ°/"3d%3d[9/7/2018 8:19:28 AM]
Florida Building Code Online
Nk 15781 12`. I Series"Ba�celona'.,Model.TSL30I"„ Extruded PVC Triple-Horizontal'Slldin "Iin act"-Window,'Missile
� Level "C�Excluiies WI Zone;3�and'4,(XOX 1/4=Sy2 1/4�and-
Y XOX,1%;3.1/3:1/3 Configurations)
'Limits of Use Installation Instructions
Approved for use in,HVHZ: No FL15781 R8.II (b)Inst'15781.12.Rdf
Approved,for use outside HVHZ:Yes, VerifleY Y
d B Lyndon Schmidt, P.E.,43409`
s
Impact"Resistant .Yes Created by:'Independent Third Party:Yes
Design Pressure.-N/A Evaluation-Reports,
*` '61
Other.See-INST 15781:12 for Design Pressure Ratings, any FL15781- R8 AE (_a)-Eval 15781.12.[1df
'F 't additional;use limitations; installation.instructions and product Created by:IndependentTtiird,Party:Yes
paritrculars:
15781.13 m. Series"Barcelona' Model Extruded PVC Triple Horizontal Sliding"Impact'Window, Missile
s' "TSL30I" Level "D"Excludes Wind Zone 4(XOX 1/4-1/2-1/4 and XOX
z 1/3-1/3-1/3 Configurations)
f .: Limits of Use Installation Instructions
1 '
Approved for use in HVHZ: No FL15781 R8 II (b)Inst 15781.13. dmf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 ;
Impact Resistant:Yes Created by Independent Third Party: Yes
" Design Pressure: N/A Evaluation Reports
u` Other:See INST 15781.13 for Design Pressure Ratings,any FLIS781 R8 AE (a) Eval 15781.13.Ddf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
15781-A4 n. series."Ba rcel ona" Model 'TSL30I" ExtrudedPVC Triple Horizontal"Sliding"Impact"Window;'High
A"s, Velocity:Hurricane Zone,Large,Missile(XQX 1/4-1/2 1/4 and _
F , :> XOX 1/3-1/3-1/3 Configurations)
a
:> Limits of.U'se InstallationYnstr'uctionsF` '
* 1A -roved for use in HVHZ:Yes-
, , FLIS781 R8 II b Inst 15781.14 df
Approved for use outside HVHZ:.
VHZ Yes Verified:ey: Lyndon F.Schmidt, P.E.43409
Impact Resistant:"Yes Created by Independent Third Party:Yes" "-
*
Design Evaluation Reports
a" 1 w Other:See'INST 1578L14 for Design=Pressure Ratings,an FL1578L`R8.AE (b) Eval�15781.14.Ddf
s*a -
r atlditional use limitations, in;stallation,instructions and product Created by Independent Third"Party Yes '
particulars.
15781.15 o. Series"Barcelona" Model "DSL30" Extruded PVC Horizontal Sliding"Non-Impact"Window(XX
Configuration)
r ' Limits of Use Installation Instructions
z t Approved for use in HVHZ: No FLIS781 R8 II (b)Inst 15781.15.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409
x ; a Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.15 for Design Pressure Ratings,any FLIS781 R8 AE (b)Eval 15781.15.pdf
¥ k: additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
..
�" 15781,.16 p. Series,"Barcelona" ModelOTSL30" Extruded PVC,Triple Horizontal Sliding"Non Impact"Window,
t r2 (XOX1'/4-1/2-1/4 and.XOX 1/3-1/3-1/3.Configurations)
x
¢ Limits of Use Installation Instructions
4y Approved for use in HVHZ: No FL-15781 'R8 II (b)Inst 15781.16 pdf
Approved for use outside'HVHZ Yes Verified By: Lyndon,F. Schmidt, P E 43409
' , Impact Resistant No ,� �.r Createdby,Independent Third"Party Yes'
D'e'sign Pressure„N/A -; m, Evaluation Reports `
Q
Other ySee.INST 15781.16 for Design Pressure Ratings,any. FL15781 RB AE`(b)Evai 15781 16,�df E
. . additional use limitations„ installationinstructions and,p oduct Created by.Independent Third Party:Yes
-
particulars:
r Contact Lic::2601 Blair Stone Road.Tallahassee FL 32399Phone:850-487-18 4
r ”
The State of Florida is an AA/EEO employer,Coovriaht 2007-2013 State of Florida.:;Privacy Statement:;Accessibility Statement-;,Refund Statement
i• k t4 Y ��r
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to apublic-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
a' • Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails
=_ s provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
„x
Product Approval Accepts:
https:Hfloridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqt3ciSAInEOW9Taf1MFDxJQgCR4F8K9N%2fsDYcoUiUZ2mQ%3d%3d[9/7/2018 8:19:28 AM]
Florida Building Code Online
w¢
Credit Card
Safe
Aft,. i9
https://floridabuilding.org/pr/pr_app_dtl.aspx7param=wGEVXQwtDqt3elSAInEOW9Taf7MFDxJQgCR4F8K9N%2fsDYeoUiUZ2mQ°/a3d%3d[9/7/2018 8:19:28 AM]
R W R W Building Consultants, Inc.
B Consulting and Engineering Services for the Building Industry
C P.O.Box 230 Valrico,FL 33595 Plione 8.13.659.9197
Florida Board of Professional Engineers Certificate of Authorization No.9813
31
31
70 1
Product Sub Category Manufacturer Product Name
Category
Soft-Lite LLC "BARCELONA"
Windows Horizontal Slider 10250 Philipp Parkway Model"SSL301"
Streetsboro,OH 44241 Sliding Window
(330)528-3400 "Impact"
Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc.and Lyndon F.Schmidt, P.E.(System ID#1998)
for Soft-Lite LLC based on Rule Chapter No.61 G20-3,Method 1 D of the,State of Florida Product Approval,Department of
Business&Professional Regulation.
RW Building Consultants and Lyndon F. Schmidt,P.E.do not have nor Will acquire financial interest in the company
manufacturing or distributing the product or in any other entity,involved in the approval process of the product named herein.
Limitations:
1. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code(FBC)structural requirements
including the"High Velocity Hurricane.Zone".
2. Product anchors shall be.as listed'and:spaced as:shown on details:Anchor embedment to,base material.shall be beyond wall dressing or
stucco.
3. When.used in the`'HVH2';,this productcomplies w Section 1626 of the FPC and does not require an impact resistant covering.
4. For 2x stud framing construction;anchoring of these unifs hall be the same.'as.that'shcW"n for 2x buck-masonry construction.
5. Site conditions•that•deviate from the .details of drawing FL-15781.11 require further engineering analysis by a licensed engineer or
registered architect.
6. See drawing FLA 5781.11 for size and design pressure limitations.
7. This product meets thew ter ififiltration requirements for"HVHZ".
uppo mg ocuments:
1. Test Report No. Test.Standard Testing Laboratory Signed by
fEL•03001826 TAS':207,202 8'203.94 Testing
,Evaluation Lab,Inc. Lyndon F,Schmidt,P.E.
TEL 03001829 TAS 201,.202•&203-94 Testing Evaluation Lab,.lnc. Lyndon F.Schmidt, P.E.
TEL 03001832 TAS 201„202:&;203-94 . Testing'Evaluation Lab,Inc. Lyndon F.Schmidt, P.E.
TEL.03001870' TAS-201,-202:&203=94 Testing.Evaluation Lab,Inc. Lyndon F.Schmidt,P.E.
2. Miami Dade NOA Materials Testinq
15-1201.11 Saflex®PVB Interlayer(Eastman Chemical Company)
15-0528.13 PVC Extrusions(Vision Extrusions Ltd.)
3. Drawing No. Prepared by Signed&Sealed by
No.FL-15781.11 RW Building Consultants,Inc.(CA 99813) Lyndon F.Schmidt,P.E.
4. Calculations Prepared by Signed&Sealed by
Anchoring RW Building Consultants, Inc..(CA#9813) 4 Lyndon F.Schmidt,P.E.
sa®,.�cat=�
ASTM E1300 Glass Load Lyndon F Schmidt; R.E. o�®®qe 'Ye”�
5. Quality Assurance
Certificate of Participation Issued by Farabbugh.Engineering and
Testing, Inc,certifying that Soft-Lite LLC is manufacturing products o" No 43409 a.
within a quality assufance:program.that complies•withISO/IEC 000l
17020,;and Guide:53.
j�0 STATE OF �� Lyndon F.Schmidt,P.E.
� +`�' FL PE No.43409
Sheet 1'of 1 �A01-1 8/29/2017
` f�fy,t�.f � 0��
°I�os naslat,%°�
°QA .
Oft Ed.
` Y Y11 doVY�7 ::(I)*.. Z �VVV O� LLm
8Yf.Y21Yig CjLlQ4ItV t0 light. ..SEE CHART FOR FRAME SIZES ''�4prr rtU `` o r0i00z°
10250 Philipp Parkway \ m a a.;
Streetsboro,Ohio 44241 tl�;+
{b E a U o Z 4
Z U
uEm omm
J C W
n1 1'. N� 5 Ram
"BARCELONA"
Model "SSL30l" �� �� � 3W r^�,
o° JAa V ,�
SLIDING WINDOW
h y WZ
"IMPACT' A
X
Q / • O Z J
O Z
� 3 r 5-
03
-m oy
J
D 4 JccW
GENERAL NOTESw o a�
1. This product has been evaluated and is in compliance with the 6th Edition(2017) a a a
Florida Building Code[FBC)structural requirements including the"High Velocity
Hurricane Zone"(HVHZ). , m
e
2. Product anchors shall be as listed and spaced as shown on details.Anchor
embedment to base material shall be beyond wall dressing or stucco,
3: When used in the"HVHT'this product complies with Secfion 1626 of the FBC and
does not require an impact resistant covering. o 0
= U �
4. For 2x stud framing construction,anchoring of these units shall be the same as that N
shown for 2x buck masonry construction.
W
5. Site conditions that deviate from the details of this drawing require further W
engineering analysis by a licensed engineer or registered architect. p =
wu MA7f MQX GtAS5 DE$ PRESSURE(FSFJ w i
6. This product meets the water infiltration requirements for the"HVHT', FRAME D LO f
i ry Q
rDtAAENSfON �''D � n'P.E _POSRIVE_ ,.fJEGATNE: o
TABLE OF CONTENTS 73.0"X 63.0"* 31.437"x 54.375" Gl +55.0 -60.0 -z v
g SHEET# DESCRIPTION ` 12
1 Typical elevations,design pressures and general notes 73.0"X 56.0" 37.437"x 47.375" GI 55.0 -60.0 sem:wA 4 26/17
+ N.T.S. °
2 Horizontal cross sections
3 Vertical cross sections 73.0"X48.0" 31.437"x 39.375" GI +60.0 -65.0
M.�' JK m
4 Buck and frame anchoringcroc Ero LFS 3
0 5 Components ORAWNG NO.:
6 Bill of materials and glazing detail *Requires external stile reinforcement(Item#17) FL-15781.11 a
SHEET I OF 6 N
1.Item#17 required for units ............. f"
0, 'n
greater Win height.
r
1-1/4"MIN.
EMB.PYP.) z
INTERIOR 1-1/4,MIN. --A
INTERIOR <
EMB.(TYP.)
>
15 5 6;
28 C 28) lif IIIA 0" z
0 C4
0 x
C3
K-0 Ci CW
C= .'t 5 a a.
t masa
0
1 X r4 0 K5 CZ
2 2
2
( 2 9 GI
9 G1
3 EXTERIOR 10
2 10
EXTERIOR 0
Ca
G
C
E IL-u
( 1:)!!�2:) 3 E
3 3 3
HORIZONTAL CROSS SECTION
r2 /�3 HORIZONTAL CROSS SECTION En W
0
Shown 13[mct to Masonry 2 Shown w/1X Buck
it
a.�
1-1/4'MIN. --------
.3:5 EMB.(TYP.) F B EMB.(TYP.) �s
C
F
INTERIOR
15 6
10
28 7 13
GI 20 z
INTERIOR in
22
C= 8 N
21 W
0
9 G1 26
10 D z
LLI
9
EXTERIOR GI 9 is - a
D 23 15 28 1 E DA7r- 4126117 12,
C 17) 27 14 9 EXTERIOR SEE NOTE I MAM N.T.S.
E 1 SEE NOTE 1 6 DWG.lrf-. JK M
NOTE: CHK.13Y.
1.Item#J located 7-114"from LFS
HORIZONTAL -6RAMNG NO.' [X
HORIZONTALHORIZONTAL CROSS SECTION L CROSS SECTION each end and I at the center r-
CROSS SECTION / 4 r5
(3 total). FL-15781.11
sviEEr 2 OF_6
CE
�Or .m `�^ N
• �',.� o P;JCI n
Q za G
B �� C 16
SEE
C SEE NOTE 1 16 -- 1 NOTE
f ��w �hiust oro z
SEE NOTE 1 16 �� — 1 10 2 {I 11 a Z m Z
J 10 q a 11 — — 28 �N ami a:am
28 m
2 11 — —E� 28 15
28 15 g - o Z
28 8 D 8 0 a
28 8 - 15 15 Q 8 15
15 8 9 9 \ G1 3 e,
G1 0 0
Z J�
~ 9 w
F EXTERIOR C'1 EXTERIOR INTERIOR EXTERIOR INTERIOR
INTERIOR � wy
N >o
15 9 15 9 0 < U
15 15 G1 o
8 8 15 9
B 8 a
D <a
8 15
28 28 Q 8 m
s 28 19 28 19 °
2 - 12 2 11 U — 12 28 28 19
SEE lQ SEE 10 — — J
NOTE 1 1 NOTE 1 1 2 12 z
Z5 16 SILICONE SEALANT 16 SEE 1Q 0
�– — SIUCONESEALANT NOTEI 1 z �
3 F Z 3 16 SILICONE SEALANT
C
C A G 3 — H V)
B �W C El- z
8 E p E E nLU z
o
m
Za — O o
5 1 VERflCAI CROSS SECTION 2 VERTICAL CROSS SECTION m DATE: 4/26/17
3 VERflCAL CROSS SECTION m D
E3 2X Buck Construction 3 Shown w/1X Buck w 3 Shown Direct to Masonry N.T.S.
DING.BT: JK m
NOTE: anc BY. LFS 3
r 1.Item#J located 41/8",17 3/8".29-1/4" DRAWING NO.:
and 31-1/4"from Jamb stye end(4 total. FL-15781.11 0
N
V SHEET 3 OF E �
d
Y)
.Z'N4Q m
u)
ed
T(TYP.) ...... J w
SASH 4� :u,) o.
G,(TYP-) 11ti, zo no lo
4"(TYP.) a Noc,�(TYP.J 6-fryp.) 1 z
3E K .w6
L 9 c
V t i ti, E .m
M
11 c o
E o z
1. v Li
11 D 2X BUCK F A R
2X IX BUCK u
I I TYP. BUCK G z
BUCK
FRAME—� DIRECTTO H
II MASONRY
MASONRY 11 MASONRY II (TYP-)
OPENING
OPENING 11
ii i 11 a
o co
Ls
C5 E2
BUCK ANCHORING FRAME ANCHORING
z
& o 9
Ln
;2 CONCRETEANCHOR NOTES: w
1.Concrete anchor locations at the comers maybe adjusted to maintain the min.
edge distance to mortar joints. w
9 Z Concrete anchor locations noted as MAX.ON CENTER"must be adjusted to w
2
maintain the min.edge distance to mortar joints,additional concrete anchors
may be required to ensure the"MAX ON CENTER"dimension are not exceeded.
3. Concrete anchor table. w -z
ANC
.TW.. ...... ANCHOR
. ..............
CLEARANCE '1141N,J:,fEA
N
C
70 zfoo4gnIs
LL ........................ " ..AN OR
I ........... ..............
wh 4126117
114- 1-1/4-
2"
TAPCON6 SCAM N.T.S.
�Lco DWG.BY: JK m
ATRACON' 1/,c 1-114- 4" CHK fff.- LFS
WOODSCREW DMMNG No.:
I.Maintain a minimum 5/8"edge distance,I"end distance,&I"o.c.spacing of FL-15787.11
-1 wood screws to prevent the splitting of wood.
SHEEr
_�4 OF 6
R:\Clients\SoR-Lite Permanent\A-Florida Product Approvals\FL-15781 Horizontal Sliders\C-Drawings\FL-157816TH ED(2017)\FL-15781.9-1l.dwg,53
1.5"
o To
� o 0
w a y �3AZI
z
b O
n ffp� a
p 0.062" y T
>e
+Zi 2.25'
n
m
0.57'
a
121" c
V
{ 0.5'
O I I p
V
z T h oo 2.87'
0.84"
y1.96, o N
0.86" _ o
= a �
o x
� 0.067'
W oi. O A { iZ
S i% 0.091" V p
L
�^ y 0.735'
O 1.23"
0.627'
O
P
N
O
0.386"
rn
s �
A Oo � pC
Z O N p A
p
aO�0.087' 1�''�y � � � o
= L
1.05' 0.124"
A I
,0 0.41"
0.627' a 0
a T
OO
' z � ^?
1`1 a Do
A Zi � A
n y
� I � �ttttttlll/r/
o II o 0.75'
-�I 0.133" No.43409
0.95°
T PRODUCT: Doaamanta Pmpamd By.- `+
a r'I i SOFT-LITE WINDOWS Lyndon F. Schmidt 11i�`''.!20RlDR•'bC��
P.E. No. 43409
jLn
o Co y PART OR ASSEMBLY: Kn,,BUILDING CONSULTANTSf INC.
I 7 12 17 REVISE GLAZING DETAIL LFS d li_I/1/ P.O. Box 230, ValNco, FL 33595
Z NO DATE BY COMPONENTS [Y�YYY Phone No': 813.1359.9197
REVISIONS FBPE C.A. No. 9813
0 2017 R.W.BUILDING CONBUI-Nt8 INC.
BILL OF MATERIALS
ITEM @ MATERIAL V.•• °i
A LX BUCK SG>=0.55 =Sed S �:
WOOD
_�: A7! h
ril
B 2X BUCK SG>=0.55 WOOD
C 1/4"MAX.SHIM SPACE Z F O�
o 6m
D 1/4'X 2-3/4"PFH ELCO OR RW CONCRETE SCREW STEEL �i��''••.,, y� o m m
E MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI CONCRETE ''�����/II �������``` to
o n`G z°
301 OR HOLLOW BLOCK CONFORMING TO ASTM C90
UN •.
F #8-15 X 2-1/2"TRUSS HEAD SMS(1-3/8"MIN.EMBEDMENT) STEEL b o c, x Z
G 114'X 3-1/4"HWH ELCO OR ITW CONCRETE SCREW STEEL E E m 3.0
a°
H 1/4!'X 2-3/4"HWH ELCO OR ITW CONCRETE SCREW STEEL
J #1016X2-1/2'PFHTEKSS $$ N aNn m°tm
U.
mdaa
1 FRAME' PVC eZ
2 HS FIXED PANEL SPACER* PVC 9 •
cW
3 WEEP HOLE COVER' PVC
4 DSL FRAME FILLER' PVC
5 DSL HANDLE SASH* PVC
6 KEEPER RAIL* PVC 3
7 LOCK RAIL' PVC 518'„GLASSBffE 7/8"THICK oo
8 DSL MAIN SASH* PVC z
"
1/9-ANNEALED
3 ¢Z
F 9 GLAZING BEAD* PVC 0 m
10 DSL COVER' PVC gg —�0.090”SAFLEX PVB INTERLAYER w 40
W 11 ANTIUFTTRACK* PVC
12 ROLLERSILLTRACK ALUM. N o m<
13 REINFORCEMENT(6065-T5 ALUM) ALUM. 1/e"ANNEALED o
14 REINFORCEMENT(6065-T5 ALUM) ALUM. AIR SPACE a a
15 REINFORCEMENT(6065-T5 ALUM) ALUM.
16 REINFORCEMENT(6065-T5 ALUM) ALUM. �� 1/8"ANNEALED OR TEMPERED* �m
0 17 REINFORCEMENT 16065-T5 ALUM) ALUM.
18 SPACER DOW 2400 SAS
19 ROLLER ASSM. - Gl GLAZING DETAIL STEEL INTERCEPT SPACER
= 20 LOCK
21 LOCK KEEPER - z
22 #7 X 3/4"PFH TEK(LOCK) SS
=o 23 PVC COVER FOR HS REINFORCING BAR(item#17) PVC *NOTE TEMPERED GLASS IS REQUIRED IN THE"HVHZ"FOR EXTERIOR GLASS GREATER THAN 30 FEET ABOVE GROUND. Ln
G 26 #8 X 1"PPH TEK(KEEPER) SS N
3 �
27 #10-16X1-1/2'PFHTEKSS SS
28 WEATHERSTRIP(187-270TRI-FIN) - En
R *THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY z
a EXTRUDERS LICENSEES IN"AAMA CERTIFICATIONS PROGRAMS FOR RIGID PVC EXTRUSIONS".
•-w z
N Q j
N
v_ O o
a wtE 4 26 17 z
a
SCUE: N.T.S. °
E
z� � M6OLIF
m
NO.:
SHEET3nmN
e �
4