Loading...
HomeMy WebLinkAboutDrawing 1CIO 1-007,5 I---I--I f--.....- l 1--I 1--1 I ! ) ' f . I /� RFCFjl'o I �� Peri,. D42819 3t•`4C. e drtm 93" X 80" I �� ty ent ri I ._ I--1--1 1 66"DOUBLE DOOR WITH (2)13 1/2"SIDELIGHTS I Ia. REPLACE DOORS AND SIDELIGHTS IN 1 OPENING ONLY. j 4 y OPENING HAS EXISTING HURRICANE PROTECTION INSTALLED UNDER PERMIT#SLC 1305-0383 PER HOMEOWNER. LU N OPENING PRODUCT DESIGN OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS NO. WDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG. 1 I 93 I 80 51.67 4 33.8 I -37.0 FL14569.6 57.0 I -57.0 FRONT ENTRY-LSMI 1 REPLACE EXISTING DOOR&SIDELIGHTS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS&SIDELIGHTS. . NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS. ALL DOOR&SIDELIGHT FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 3/16"TAPCON SCREWS INTO CONCRETE WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURERS PRODUCT APPROVAL DOCUMENTS. LESS THAN 30%OF STRUCTURES VALUE. NOTA RENOVATED BUILDING. EXEMPT FROM 2017 ENERGY CONSERVATION CODE. SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES MEAN ROOF HEIGHT= 11 FT 7 IN SMITH RESIDENCE 179 S.E. PLACITA COURT DOOR REPLACEMENT PLAN i PORT ST. LUCIE, FLORIDA