HomeMy WebLinkAboutWind Load Calculation ALL WIND LOADS DESIGNED IN ACCORDANCE WITH ASCE 7-10 PER SECTION 1609 OF THE 2017 FLORIDA BUILDING CODE ROOF PITCH IS GREATER THAN 2712" OR >= 10 DEGREES PROJECT NAME: D NOA or FL# r . ADDRESS 3 d O fah e- wG• �z NOA or FL# CITY/STATE r r NOA or FL# CLADDING TYPE: �O bLr�i Cc � NOA or FL# COMPONENTS AND CLADDING OF WALLS ULTIMATE DESIGN WIND SPEED (Vult 160 D ;0 n z u1 NOMINAL DESIGN WIND SPEED Vasd 124 ROLL DOWNS, WINDOWS, MULLIONS, 3 EXPOSURE B HEADERS,STORM BARS etc. 0 MEAN ROOF HEIGHT 30 D 0 TOP OF WINDOW OR SHUTTER HEIGHT .25 EFFECTIVE WIND AR AS ° WIND DIRECTIONALITY FACTOR 0.85 Vu/t Vasd Vu/t Vasd Vu Vasd ENCLOSED BUILDING GCpI=+0.18 <=10SF 10SF><=20SF 20SF><=50SF POSITIVE PRESSURE (ZONE 4+5) 43.7 26.2 41.8 25.1 39.2 23.5 NEGATIVE PRESSURE (INTERIOR ZONE 4) -50.0 -30.0 -47.9 -28.7 -45.2 -271 NEGATIVE PRESSURE (END ZONE 5) -61.7 -37.0 57.5 -34.5 -52.0 -31.2 PARTIALLY ENCLOSED BUILDING GCpi=±0.55 <=10SF 10SF><=20SF 20S.F><=50SF POSITIVE PRESSURE ( ZONE 4+5) 57.4 34.5 55.5 33.3 52.9 31.7 NEGATIVE PRESSURE (INTERIOR ZONE 4) -64.4 -38.6 -62.3 -37.4 -59.6 -35.8 NEGATIVE PRESSURE (END ZONE 5) 1 -76.1 -45.7 -72.0 -43.2 -66.5 -39.9 LIGHT GREY AREAS ARE ALLOWABLE STRESS DESIGN PRESSURES 1/17/2018