Rule 61G20-3 F.A.C. ) Project No.418-0102 1 1/8/18 ) Page 1 of 2
Product Manufacturer Product Name,Model and/or Description
Maxim Industries,Inc. Dade Curb Mount Skylight Polycarbonate Glazed Aluminum Skylight
1630 Terre Colony Court Dade Self Flashing Skylight Pol c r onate Glazed Aluminum Skylight
Dallas;TX 75212 FJAAN
D
Florida Product Approval No.: FL2418 019
Code: 61h Edition(2017)Florida Building Codei�nrrnli'tln0
�.___
Compliance Method:
• Product Approval Rule 61G20-3.007(1)(f)–Self-Affirmation
• Product Approval Rule 61G20-3.005(1)(d)–Product Evaluation Report by a Licensed Professional Engineer
• Product Approval Rule 61G20-3.015(4)(d)–Equivalency of Standards
• Product Approval Rule 61G20-3.005(1)(e)–project specific approval by the local authorities having jurisdiction in
accordance with alternate methods and materials authorized in the Code(Section 104.11)
Code Conformance Review:The undersigned has reviewed the above referenced Florida Product Approval and associated
documents and found all drawings,reports,referenced test standards,and testing as noted in the approved documents to be
in compliance with the 6th Edition(2017)Florida Building Code.
It has been concluded that no revisions,or changes to the referenced standards have occurred between the following(where
applicable)that affect the results of design,testing or engineering of the approved product(s).
• Chapter 35 of the 51h Edition(2014)Florida Building Code compared to Chapter 35 of the 61h Edition(2017)Florida
Building Code
,. • Chapter 46 of the 5th Edition(2014)Florida Residential Code compared to Chapter 46 of the 6th Edition(2017)Florida
' Residential Code
yti
,, • Test Protocols for HVHZ/51 Edition(2014)Florida Building Code compared to Test Protocols for HVHZ/6th Edition
(2017) Florida Building Code,specifically the following where applicable.
o TAS 201=94,TAS 202-94 and TAS 203-94
Conformance Review of skylight glazing material Manufacturer(s)and Component Approval per Miami-Dade NCA:
• The currently issued Miami-Dade NOA for component approval to the Florida Building Code for Covestro,LLC
LUMakrolon Polycarbonate Sheets was reviewed and found to be in compliance with the 6th Edition(2017)Florida
Building Code.Covestro,LLC Miami-Dade NOAs can be found here.
1—I
Therefore,all test standards used in testing and.all design standards used in design and engineering of the currently approved
product(s)remain valid for compliance to the 61 Edition(2017)of the Florida Building Code.
Certification Agency Certificate(attached)
• -. N1009198-115,Expiration-12/31/21 for-Dade Self-Flashing Skylight
• N1009198.01-115,Expiration 12/31/21 for Dade Curb Mount Skylight
Installation Instructions(available from Product Manufacturer)
• Drawing No.DSF1507,Dated 7/10/15,signed&sealed by T.Berman,P.E.
• Drawing No.DCM1507,Dated 7/10/15,signed&sealed by T.Berman,P.E.
PTC Product Design Group, LLC ( PO Box 520775 1 Longwood, FL 32752-0775
r/L 321-690-1788 1 FBPE Certification of Authorization No. 25935
Product Conformance to 6th Edition (2017) Florida Building Code
Rule 61G20-3 F.A.C. I Project No. 418-0102 1 1/8/18 1 Page 2 of 2
Certificate of Indepenence per Product Approval
Rule 6d1 G20-3.009Digitally signed
E IV 1t
4;b
by Robert J
PTC Product Design Group,LLC and Robert J.Amoruso,P.E. Z N 49752 0
does not have,nor will acquire,any financial interest in the
company manufacturing or distributing product(s)covered Amoruso
by this Product Evaluation Report. ST E OF .:,W
z -Date:*,2018.01.08
PTC Product esign Group,LLC and Robert J.Amoruso,P.E.
do not haveD,nor will acquire any financial interest in any 16:55:50 -05'00'
other entity involved in the approval process or testing of
the product(s)covered by this Product Evaluation Report. Evaluated by:
Robert J.Amorusoj P.E.
Fl.P.E.License No.49752
PTC Product Design Group, LLC I PO Box 520775 1 Longwood, FL 32752-0775
JowAVA, 321-690-1788 1 FBPE Certification of Authorization No. 25935
NOTICE OF PRODUCT CERTIFICATION �■
CERTIFICATION NO: NI009198.01-R5
DATE: 12/30/2007
CERTIFICATION PROGRAM: Structural
COMPANY: Maxim
CODE: M-1256-1
REVISION DATE: 08/21/2017
To verify that the"Notice of Product Certification"is valid,please visit www.NAMICertification.com to assure that
the product is active and currently listed.This certification represents product conformity to the applicable
specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied
to the product to claim certification status. Please review and advise NAMI if any corrections are required to this
document.
COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION
Maxim Industries,Inc. Series"Dade Curbmount"
1630 Terre Colony Court Polycarbonate Glazed Aluminum Skylight
Dallas,Texas 75212
Configuration: O
Glazing:Exterior Dome-0.118"Hyzod Polycarbonate
w/8"rise/Interior Dome-0.118"Hyzod Polycarbonate
w/4"rise
Overall: W-414" DLO: W-4'0"
H-814" H-810"
SPECIFICATION PRODUCT RATING
TAS 201/202/203-94 Design Pressure:+60/-60 psf
Large Missile Impact Rated
Product Tested By: Architectural Testing,Inc.
Report No: ATI-01-43381.01
Expiration Date: December 31,2021
Administrator's Signature:
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Highway
Hayes,VA 23072
Tel:(804)684-5124
Fax: (804)684-5122
NOTICE OF PRODUCT CERTIFICATION
CERTIFICATION NO: NI009198-R5
DATE: 12/30/2007
CERTIFICATION PROGRAM: Structural
COMPANY: Maxim
CODE: M-1256-1
_. REVISION DATE: 08/21/2017
To verify that the"Notice of Product Certification"is valid,please visit www.NAMICertification.com to assure that
the product is active and currently listed.This certification represents product conformity to the applicable
specification and that certification criteria has been satisfied. A NAM approved certification label must be applied
to the product to claim certification status. Please review and advise NAMI if any convections are required to this
document.
COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION
Maxim Industries,Inc. Series"Dade Self-Flashing"
1630 Terre Colony Court P_olycarbouate Glazed Aluminum Skylight.
Dallas,Texas 75212
Configuration:O
Glazing:Exterior Dome-0.118"Hyzod Polycarbonate
w/8"rise/Interior Dome-0.118"Hyzod Polycarbonate
w/4"rise
Overall: W-4'6" DLO: W-39"
H-816" H-719"
SPECIFICATION PRODUCT RATING
TAS 201/202/203-94 Design Pressure: +60/-60 psf
Large Missile Impact Rated
Product Tested By: Architectural Testing,Inc.
Report No: _ ATI-01-43381.01
--.:-Expiration Date: December 31 -2021
Administrator's Signature:
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE,INC.
4794 George Washington Memorial Highway
Hayes,VA 23072
Tel: (804)684-5124
Fax:(804)684-5122