HomeMy WebLinkAboutWind Load Calculation PA-,
9FER"
RECEIVED
"Building our Q0ali 'ReP.utatlon JAN 10 2019
}CT1e, A f ' Time ST. Lucie County, Permitting
LE U0PYSSCC131150472
Property Information Building Information
Owner: RENATO&LORETTA MINNEI Wind Zone: 170 MPH.
Address: 8128 LINKS WAY Exposure Category: C
PSL,FL 34986 Minimum Building Dimension: 59 ft.
Mean Roof Height: 14 ft.
Jul Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 75 24 7. 37.1 -40.3
..----_.. ---- --- _......._. --- ---_.- ----- --
2 Int 52 71 7 35.5 38.7
3 End 47 23 7 37.8 -50.6
4 End 4947 7 36.6 -48.3
-----.....--- ---..-....._._ ..._..._.................... _...........---- -__...._.............----- ------- - ----..�--
5 End 36 22 7 37.8 -50.6
_....._... __ -- - --
6 Int 26 37 7 37.8 -41.0
_........... - . - .__._. ---- --_........ - .......... .......-- --.._.._. ..----- - - -._-... _.......----- - ......---- --...- -
7 End 95 94 7 33.3 -41.6
- ---- ......... .------._... -- -
8 Int 141 120 7 31.7 -34.9
---_ --...-- -- ...................... .........------ .. __ .._.. --........... _.-... -- .. ---- -..... ----- - - -----
9 Int 36 22 7 37.8 41.0
10 Int 36 72 7 36.4 -39.6
11 Int 36 22 7 37.8 -41.0
12 Int 36 72 7 36.4 -39.6
13 Int 36 22 7 37.8 -41.0
14 Int 36 72 7 36.4 -39.6
15 Int 33 97 7 35.8 -39.0
16 Int 30 21 7 37.8 -41.0
17 Int 110 63 7 33.9 - -37.1
18 Int 36 31 7 37.8 -41.0
...............
19 Int 36 31 7 37.8 -41.0
20 Int 36 - 31 7 37.8 -41.0
____------------------ -- ---- ------ _.....-......-- __.. --..._........._.. ----
21 End 31 81 7 36.4 -47.9
22 Int - 36 71 7 36.4 -39.6
23 Int 36 71 7 36.4 -39.6
24 Int26 37 7 37.8 -41.0
._.._..........._..._
25 Int 52 71 7 35.5 -38.7
Page 1 of 2
I[ORS
PARADISE_ : T k
"Building Our Quality Reputatio i RECEIVED
One Customer-At A Time" JAN 10 2019
SCC131150472 sr. Lucie County, Permitting
Property Information Building Information
Owner: RENATO&LORETTA MINNEI Wind Zone: 170 MPH.
Address: 8128 LINKS WAY Exposure Category: C
PSL,FL 34986 Minimum Building Dimension: 59 ft.
Mean Roof Height: 14 ft.
UL Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
26 Int 34 81 7 36.2 -39.4
27 Int 39 62 7 36.5 -39.7
28 Int 39 62 7 36.5 -39.7
29 Int 52 49 7 36.4 -39.6
30 Int 36 71 7 36.4 -39.6
31 Int 36 71 7 36.4 -39.6
_ -.-.........— --.................---
32 Int 74 96 7 33.9 -37.1
FILE %aupy
Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.
Page 2 of 2
Im
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Corner Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING SHUTTERS
( ) (-)
NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF + PSF PSF DIMENSIONS MULLION REQ Y/NSIZE REQ Y/N/NA
1 Int Window 1"Lami IG FL13010.4 67.5 67.5 37.1 -40.3 72 x 76 75x24 No No
2 Int Window 718"Lamm IG FL15780.8 55 65 35.5 -38.7 54 x 76.5 52x71 No No
3 End Window 1"Lami IG FL13010.4 55 55 37.8 -50.6 48X72 47x23 No No
4 End Window 1"Lami IG FL13010.4 55 55 36.6 -48.3 48X72 49x47 No No
5 End Window T'Lami IG FL13010.4 55 55 37.8 -50.6 48X72 36x22 No No
6 Int Window '"Lam" FL15780.8 55 65 37.8 -41.0 54x76.5 26x37 No No
7 End Door I"Lami IG FL11103.1 60 60 33.3 -41.6 96 x 96 95x94 No No
8 Int Door 1"Lami IG FL20838.3 65 65 31.7 -34.9 185.120 141x120 No No
9 Int Window 1"LamilG FL13010.4 55 55 37.8 -41.0 48X72 36x22 YES No
10 Int Window 718"L.amilG FL15780.8 55 65 36.4 -39.6 54x76.5 36x72 YES No
11 Int Window 1"LamiIG FL13010.4 55 55 37.8 -41.0 48X72 36x22 YES No
12 Int Window ��8"Lam�IG FL15780.8 55 65 36.4 -39.6 54x76.5 36x72 YES No
13 Int Window I"LmiIG FL13010.4 55 55 37.8 -41.0 48X72 36x22 YES No
14 Int Window 7/8"La-1 IG FL15780.8 55 65 36.4 -39.6 54x76.5 36x72 YES No
15 Int Door I"LamiIG FL15210.7 65 65 35.8 -39.0 37.5x97 33x97 YES No
16 Int Window 1"Lami IG FL13010.4 55 55 37.8 -41.0 4802 30x21 YES No
17 Int Window 718"L.amiIG FL16736.2 60 60 33.9 -37.1 111x63 110x63 YES No
18 Int Window 1"LamiIG FL13010.4 55 55 37.8 -41.0 4802 36x31 YES No
19 Int Window 1"Lami IG FL13010.4 55 55 37.8 -41.0 4802 3601 YES No
20 Int Window 1"Lami IG FL13010.4 55 55 37.8 -41.0 48X72 36x31 YES No
21 End Door I Lami IG FL15210.4 75 75 36.4 -47.9 37.5 x sI 31x81 No No
22 Int Window 78"Lami'G FL15780.8 55 IVE05 - 36.4 -39.6 54x76.5 36x71 No No
JAN 10 2019
ST. Lucie County, Permitting
NIL
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Comer Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS
SIZE REQ Y/N/NA
NUMBER or Interior OR DOOR TYPE NUMBER (+)PSF (-)PSF (+)PSF (-)PSF TESTED DIMENSIONS MULLION REQ YIN
23 Int Window 7/8"Lami 1G FL15780.8 55 65 36.4 -39.6 54.76.5 36x71 No No
24 Int Window 7/8"Lami IG FL15780.8 55 65 . 37.8 -41.0 54 x 76.5 26x37 No No
25 Int Window 7/8"Lam1IG FL15780.8 55 65 35.5 -38.7 54.76.5 5201 No No
26 Int Door Solid FL15210.1 75 75 36.2 -39.4 37.5x8[ 34x81 No No
27 Int Window 7/8"LanliIG FL15780.8 55 65 36.5 -39.7 54x76.5 39x62 YES No
28 Int Window 7/8"Lami IG FL15780.8 55 65 36.5 -39.7 54x76.5 39x62 YES No
29 Int Window 7/8"Lami IG FL15780.8 55 65 36.4 -39.6 54 x 76.5 52x49 No No
30 Int Window 7/8"Lami 10 FL15780.8 55 65 36.4 -39.6 54x76.5 3601 YES No
31 Int Window 7/8"Lam1IG FL15780.8 55 65 36.4 -39.6 54x76.5 36x71 YES No
32 Int Door V Lami IG FL15210.9 65 65 33.9 -37.1 74 x 97 74x96 No No
ECE VED
I !1�:--MlIty, g