Loading...
HomeMy WebLinkAboutWind Load Calculation ,PAR., -A- E-, T,,-E-W-,;, "Building Our Quality Reputation One Customer At A Time" SCC131150472 Property Information Building Information Owner: GEORGE&JUDY LANDRY Wind Zone: 170 MPH. Address: 6305 S HEADER CANAL RD Exposure Category: C FORT PIERCE,FL 34987 Minimum Building Dimension: 62 ft. Mean Roof Height: 12 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number I Zone I Width(in)_IL Height(in) [Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 36 61 7 36.8 -40.0 ...... ___..-- - -_ .. .... .-._. ......... -----... ......._......._---- - 2 Int 51 34 7 37.3 -40.5 ...... ._ _ _..__-._ _ .......- .._...._ _._.--- ---....__ -..--.__. . ...................---- 3 Int 51 35 7 37.3 -40.5 4 Int 51 34 7 37.3 -40.5 .................. _.-._... - -._....--- 5 Int 36 37 7 37.8 -41.0 6 End 36 36 7 37.8 -50.6 7 End 35 61 7 36.8 -48.7 -._....._. -...................-' - -- --'- --- - -- 8 End 35 61 7 36.8 -48.7 9 Int 36 61 7 36.8 -40.0 10 Int 73 49 7 35.6 -38.8 11 Int 73 49 7 35.6 -38.8 '--.......................... --- - - - 12 Int 73 49 7 35.6 -38.8 -------- - --- --................. -- -- --.... ----- 13 Int 73 37 7 36.3 -39.5 14 End 73 37 7 36.3 -47.5 15 Int 18 24 7 37.8 -41.0 16 Int 18 24 7 37.8 -41.0 17 Int 18 24 7 37.8 -41.0 RECEIVED JAN 10 2019 ST. Lucie County, Permitting hi Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1 � e goo - e - o - • A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Comer Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE LOCATION Corner Zone WINDOW GLAZING ACCEPTANCE APPROVED PRESSURE RATING DESIGN PRESSURE M OPENING WINDOW SHUTTERS NUMBER or Interior OR DOOR TYPE NUMBER (+)PSF (-)PSF (+)PSF (-)PSF TESTED DIMENSIONS MULLION REQ Y/N SIZE REQ Y/NINA 1 Int Window 7/8"LamiIG FL15780.8 55 65 36.8 -40.0 54x76.5 36x61 No No 2 Int Window 7/8"Lami IG FL15780.8 55 65 37.3 -40.5 54x76.5 51x34 No No 3 Int Window 7/8"Lami lG FL15780.8 55 65 37.3 -40.5 54x76.5 51x35 No No 4 Int Window 7/8"Lami IG FL15780.8 55 65 37.3 -40.5 54x76.5 51x34 No No 5 Int Window 7/9Lami IG FL15780.8 55 65 37.8 -41.0 54x76.5 36x37 No No 6 End Window 7/8"LamiIG FL15780.8 55 65 37.8 -50.6 54x76.5 36x36 No No 7 End Window 718"Lami IG FL15780.8 55 65 36.8 -48.7 54 x 76.5 3 5x61 No No 8 End Window 7`81, L'iIG FL15780.8 55 65 36.8 -48.7 54x76.5 35x61 No No 9 Int Window 7/8"Lami lG FL15780.8 55 65 36.8 -40.0 54x76.5 36x61 No No 10 Int Window 7/8"LamilG FL15781.11 55 60 35.6 -38.8 73x63 73x49 No No 11 Int Window 718"LamiIG FL15781.11 55 60 35.6 -38.8 73 x 63 73x49 No No 12 Int Window lis"LamiIG FL15781.11 55 60 35.6 -38.8 73 x 63 73x49 No No 13 Int Window 7/8"LmiIG FL15781.11 55 60 36.3 -39.5 73 x 63 7307 No No 14 End Window lis"Lam,IG FL15781.11 55 60 36.3 -47.5 73 x 63 7307 No No 15 Int Window 7/8"Lam' FL16177.1 70 70 37.8 -41.0 52x62 18x24 No No 16 Int Window 7/8"Lami FL16177.1 70 70 37.8 -41.0 52x62 18x24 No No 17 Int Window 7/8"Lam' FL16177.1 70 70 37.8 -41.0 52x62 18x24 No No RECEIVED—` qrr u e oun erm ng