Loading...
HomeMy WebLinkAboutProduct Approval-Modified Bitumen Roof Systems / 90 °1 -541 RECEIVZO JAAI 1 4.101 EXTERIOR RESEARCH&DESIGN,LLC. 14 _ per 9 Certificate of Authorization#9503 mllrting o 353 Christian Street TRINITY ERDr Lucie t'„rt enr Oxford,CT 0648 (203) 262-9245 • EVALUATION REPORT TRI-BUILT Materials Group,LLC - Evaluation Report A42970.10.12-R2 PO Box 70 FL16027-R2 Rutherford, NJ 07070 - Date of Issuance:10/23/2012 (800)516-1485 Revision 2:09/25/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6th Edition(2017)Florida Building Code sections noted herein. • DESCRIPTION: TRI-BUILT Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. I CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity'ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available far inspection at the job site at the request of the Building Official. • This Evaluation Report consists of pages 1 through 4,plus a 26-page Appendix. Prepared by: • • r5V:% -sires- .▪? •i: Robert J.M. Nieminen, P.E. �•.�, ,•''+fit`s'•:=°t • The facsimile seal appearing was authorized by Robert Nieminen, Florida Registration No.59166,Florida DCA ANE1983 ',ns'; s4=• P.E.on 09/25/2017.This does not serve as an electronicallysigned ..l�11n"sarts document. si g CERTIFICATION OF INDEPENDENCE: 1. Exterior Research&Design,LLC.d/b/a Trinity I ERD does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or . distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process bf the product. 5. This is a building code evaluation. Neither Trinity'ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. QTRINITY ERD . F r iL Yai rcpr'• �,. .+ ....0"tY« M l ! . "4 6 , .. ..a �'' ,r iii. ;i;:APpENDI a1 AfncHMENREQUIREMENTS,FORWIN�<UPiIFi�RESISTANE.•.t i�`,tnw;%�+..e.s��?.�tl,���vt'¢� r..Q��E:�r�j' ,.,aiw� �y s�'y' ,�y�,rl� '���'.�� r,0410...4*,,.. • �h; � 'it �'����,_"W �,+ Table Deck Application Type Description Page lA-1 Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 4 1A-2 Wood New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 5 1B Wood New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 5 — 1C Wood New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 6 1D Wood New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 6 1E-1 Wood New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 7 1E-2 Wood New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 8 1F Wood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 8 • 2A Steel or Structural concrete New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 9 2B Steel or Structural concrete New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover g 2C Steel or Structural concrete New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 10 3A Structural concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 11-14 3B Structural concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover • 14 4A LWIC New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 15-16 4B LWIC New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 16 . 4C LWIC New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 17-19 5A CWF New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 20 SB CWF New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 21 5C CWF New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 22 SD CWF New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 22 5E CWF New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover . .22 6A Gypsum New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 23 6B Gypsum New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover • 24 • 6C Gypsum New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 24 6D Gypsum New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 24 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover • 25-26 7B Various Recover F Non-Insulated,Bonded Base Sheet,Bonded Roof Cover - 26 The following notes apply to the systems outlined herein: 1.. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation/base sheet fasteners shall be of sufficient length for the following deck engagement: .•Wood: Minimum 0.75-inch penetration. 'e Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. , i=Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum-based roof board or mineral-wool roof board that meets the QA requirements of F.A.C.Rule 61G20-3 and is documented as meeting FBC 1505.1 and;for foam plastic,FBC Chapter 26,when installed with the roof cover. — — — - -- Exterior Research and Design,LLC.d/b/a Trinity)ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization 119503 61H EDITION(2017)FBC NON-HVHZ EVALUATION Revision 2:09/25/2017 Prepared by: Robert Nieminen,PE-59166 TRI-BUILT Modified Bitumen Roof Systems;(800)516-1485 Appendix 1,Page 1 of 26 ,t- ,•_ QTRINITY I ERD 4. Minimum 200 psi,minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D(mechanically attached base sheet,bonded roof cover),whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5. Preliminary insulation attachment for System Type D:Unless otherwise noted,refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29(January 2016). 6. Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published Instructions. _ > HA(HA): Full coverage at 25-30 lbs/square. Y Dow INSTA STIK Quik Set Insulation Adhesive(D-15): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c. Y Millennium One Step Foamable Adhesive(M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c. Y OMG OlyBond 500(OB500): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c.(PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced. > OlyBond Classic(OB Classic): Full coverage at 1 gal/square. ICP Adhesive&Sealants CR-20: Continuous 2.5-3.5-inch wide ribbons,12-inch o.c. >Note: When multiple layers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,adhesive ribbons shall be staggered from layer-to-layer a distance of one-half the ribbon spacing. > Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted,all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table: > Millennium One Step Foamable Adhesive(M-OSFA): MDP -157.5 psf (Min.0.5-inch thick) >OMG OlyBond 500(0B500): MDP -45.0 psf (Min.0.5-inch thick Multi-Max FA-3) > OMG OlyBond 500(OB500): MDP -187.5 psf (Min.0.5-inch thick ISO 95+GL) ➢OMG OlyBond 500(08500): MDP -315.0 psf (IVIln.0.5-inch thick ENRGY 3) >OMG OlyBond 500(08500): MDP -487.5 psf (Min.0.5-inch thick ACFoam II) Y ICP Adhesive&Sealants CR-20: MDP -117.5 psf (Min.1.0-inch thick) 8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or partially bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29,Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisks carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 10. For fully bonded assemblies,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16,and no rational analysis is permitted. 11. For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12. For existing substrates in a bonded recover or re-roof installation,the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive,and the existing roof system(for recover)shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction,as documented through field uplift testing in accordance with ANSI/SPRI IA-1,ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. For Recover Applications using System Type D,the insulation is optional;however,the existing roof system shall be suitable for a recover application. 14. Lightweight Insulating Concrete(LWC)shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced,refer to current LWC Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top-coat thickness is 2-inches. For LWC over structural concrete,reference is made to FBC Section 1917.4.1,Point 1. Exterior Research and Design,LLC.d/b/a Trinity)ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 2:09/25/2017 Prepared by: Robert Nieminen,PE-59166 TRI-BUILT Modified Bitumen Roof Systems;(800)516-1485 Appendix 1,Page 2 of 26-_ • QTRINITY I ERD 15. Unless otherwise noted,refer to the following references for bonded base,ply or cap sheet applications. � ;:.':'184404.," 14.44�? ome3A � k:Y �$ a�gq�?n� i � ?" d .�,� rI �d .Q � =;• 1, Reference Layer Material Application BP-AA Base Ply FBC Approved ASTM 04601,Type II (Base and Ply sheets,Asphalt-Applied) Ply FBC Approved ASTM D2178,Type IV or VI HA at 20-40 lbs/square SBS-AA — (SBS,Asphalt-Applied) Cap Ply TriBuilt SBS Granular HA at 20-40 lbs/square SBS-TA (SBS,Torch-Applied) Cap Ply TriBuilt SBS Granular Torch-Applied SBS-SA Base Ply TriBuilt SA.SBS Base 585,Self-Adherin Self-Adhering ( g) Cap Ply TriBuilt SA SBS Cap APP-TA Base Ply or Ply TriBuilt APP Smooth (APP,Torch-Applied) Cap Ply TriBuilt APP Smooth,TriBuilt APP Granular Torch-Applied APP-SA (APP,Self-Adhering) Cap Ply TriBuilt SA APP Cap Self-Adhering 16. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure(MDP)limitations. The lesser of the MDP listings below vs.those in Table 3A applies: V'4ad&.BAR 0.01.&ISIS+iiOt°Pt. a�„�'Co1gCREtE' t10`. (RED,l r9 W a` ' gT, �.• -, Z _. „ _,..�._...... .... ., . .�_.., ..r�,...,. .. �. ......,�� .tt�A•f~�1�,.. °� � .. ...,. rv,,;,.� �r" �' " �+.. +.:"� �. "� �:r ,e. �,ak a �� y.,�� w.�'tc a ,Y '.r, , Vapor Barrier Option# Primer Insulation Adhesive MDP(psf) Type Attach VB-1. ASTM D41 TriBuilt SA SBS Base Self-Adhering Inta-Stik or CR-20,12-inch o.c. -60.0 VB-2. ASTM D41 TriBuilt SA SBS Cap Self-Adhering Insta-Stik,12-inch o.c. -75.0 VB-3. ASTM D41 TriBuilt SA SBS Cap Self-Adhering Millennium One Step Foamable Adhesive,12-inch o.c. -157.5 VB-4. ASTM D41 TriBuilt SA SBS Cap Self-Adhering CR-20,12-inch o.c. -270.0 VB 5. ASTM 041 TriBuilt SA SBS Base Self-Adhering Millennium One Step Foamable Adhesive,Millennium PG-1 Pump Grade -290.0 Adhesive,OlyBond 500 or CR-20,12-inch o.c. 17. Dens Deck shall be field-primed with PG100 prior to self-adhering membrane application. Refer to tables herein for other priming requirements. 18. "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design,LLC.d/b/a Trinity(ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization#9503 6TH EDITION(2017)FBC NON-HVHZ EVALUATION Revision 2:09/25/2017 Prepared by: Robert Nieminen,PE-59166 TRI-BUILT Modified Bitumen Roof Systems;(800)516-1485 Appendix 1,Page 3 of 26 QTRINITY ERD �.. ,AB .k ,R rei� ,,,oi ' ,*{,s s G,,s .,,,Ar T. . uffai v ::*gip y-� two cat -.-:ro. mow. a�Tilt: 6 �,T> ,r�, -;.«-yfirf� ri", .i' `.; r,` ),."`i ^+`x fi.',; s!,r •a� � d �, ! 4 .vs,ca .r0r " 'V � �J" , ` � 1 �D� S1 �Tw6Cfy tG -.o � t' 4e :,' � .`�des 4�.r r�` fr' ,- � E � s�� H.� si�� t _. � . � � ��t�v t4SY� �.MA.y.� A Mg A� M4Y fHDA lQ QR T � od _ 4 „ f. - �, .. . �. � � , ,,;. . ,� System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15) MDP No. (Note 1) Type Fasteners Attach Type Attach Type Attach I Base Ply Ply Cap Ply (psf) Min.0.25-inch Dens Polyglass G2 Base, 8-inch o.c.in 4- Deck,Dens Deck Prime, Min.19/32- CertainTeed Glasbase, 32 ga.,1-5/8- inch lap and 8- (Optional)FBC SECUROCK Gypsum- inch plywood Firestone MB Base,JM inch diameter inch o.c.in Approved, Fiber Roof Board,Min. SBS-AA, p yw (Optional) W-1 tin caps with 11 three,equally ASTM C1289, HA 0.75-inch FescoBoard HA BP-AA SBS-TA, -60.0 at max.24- Perma-Ply 28,TamkoBP-AA inch spans Glass Base or ga.annular ring spaced, type II polyiso- (homogeneous)or min. APP-TA GAFGLAS#75 shank nails staggered cyanurate 0.5-inch Structodek center rows High Density Fiberboard Roof Insulation Polyglass G2 Base, 8-inch o.c.in 4- 32 ga.,1-5/8- inch lap and 8- (Optional)FBC (Optional) Min.19/32- CertainTeed Glasbase, Min.0.25-inch Dens SBS-SA, inch plywood Firestone MB Base,JM inch diameter inch o.c.in Approved, Deck,Dens Deck Prime, One or APP-SA, W-2 at max.24- Perma-Ply 28,Tamko tin caps with 11 three,equally ASTM C1289, HA SECUROCK Gypsum- HA SBS-SA more SBS- SBS-TA or -60.0 inch spans Glass Base or ga.annular ring spaced, type II polyiso- Fiber Roof Board SA or APP-TA GAFGLAS#75 shank nails staggered cyanurate APP-TA center rows 6-inch o.c.in 4- 32 ga.,1-5/8- inch lap and 6- Min.2-inch D-IS,OB500, Min.19/32- ACFoam II,III, CR-20 or M- Min.0.25-inch Dens D-IS, Polyglass Elastobase inch diameter Inch o.c.in SBS-AA, inch plywood H-Shield,H- OSFA,atop Deck,Dens Deck Prime OB500, (Optional) W-3 or Polyglass tin caps with 12 four,equally BP-AA SBS-TA, -60.0* at max.24- Shield CG, fastener or SECUROCK Gypsum- CR-20 or BP-AA inch spans Elastobase Poly ga,annular ring spaced, Multi-Max FA3 rows,7-inch Fiber Roof Board M-OSFA APP-TA shank nails staggered center rows or ENRGY-3 oc 6-inch o.c.in 4- Min.2-inch D-IS,OB500, 32 ga.,1-5/8- inch lap and 6- (Optional) Min.19/32- ACFoam II,III, CR-20 or M- D-IS, SBS-SA, Polyglass Elastobase inch diameter inch o.c.in One or inch plywood H-Shield,H- OSFA,atop (Optional)Additional OB500 APP-SA W-4 or Polyglass tin caps with 12 four,equally SBS-SA more SBS- -60.0* at max.24- Shield CG, fastener layers of base insulation CR-20 or SBS-TA or Elastobase Poly ga.annular ring spaced, SA or inch spans shank nails staggered Multi-Max FA3 rows,7-inch M-OSFA APP TA APP-TA center rows or ENRGY-3 oc Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization#9503 6T”EDITION(2017)FBC NON-HVHZ EVALUATION Revision 2:09/25/2017 Prepared by: Robert Nieminen,PE-59166 TRI-BUILT Modified Bitumen Roof Systems;(800)516-1485 Appendix 1,Page 4 of 26 . • Q TRINITY ERD t,- 6 , s o ,S . ti BEAu Z,WOODC�it S N.EVNCdVTtGI0REO .,• 0A R�RCOVE � � x:�; ;!;:'.':,,;',,:::.;',,:-.ti.. ``� i'� -�a'b : •y * i . 1r� r.;v11f'4:'""'4114'''''''7'447'4 §.,,,;k14''''''''7Ea .IaA C *-. 1.T4'14� Y .T ��O �►SL�TC IV BIN�E �0 -tGr '' RSt''',d ;�.r,• �7,� 'R b• s c d�.,�:50 w ;z.i..a:r.: s „,,4 _'.24 A< ST VXPEMFA4 ' TA�CDIANRtea�..—,� 1�!.,, ,,,,a, . A6',,,,,—°...L., te" :;��•,8��a. � t� . '. { S.aG ; jSystem Deck Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15) MDP �,. No. (Note 1) Type Fasteners Attach Type Attach Type Attach Base Ply Ply Cap Ply (psf) 12-inch o.c.in 4- Min.0.25-Inch Dens Deck, Polyglass (Optional)FBC Dens Deck Prime,SECUROCK Min.19/32- OMG Flat inch lap and 12- Elastobase or Approved, Gypsum-Fiber Roof Board, inch plywood Bottom Plates inch o.c.in two, (Optional) SBS-AA,SBS- W-5 Polyglass ASTM C1289, , HA Min.0,75-inch FescoBoard HA BP-AA -60.0 at max.24- Elastobase (square)with equally spaced, BP-AA TA,APP-TA inch spans Roofgrip#12 staggered center type II polyiso- (homogeneous)or min.0.5- Poly cyanurate inch Structodek High Density rows Fiberboard Roof Insulation Polyglass 12-inch o.c.In 4- yg (Optional)FBC (Optional) Min.19/32- OMG Flat inch lap and 12- Elastobase or Approved, Min.0.25-inch Dens Deck, One or SBS-SA,APP- inch plywood • Bottom Plates inch o.c.in two, W-6 Polyglass ASTM C1289, HA Dens Deck Prime,SECUROCK HA SBS-SA more SBS- SA,SBS-TA -60.0 at max.24- Elastobase (square)with equally spaced, type II polyiso- Gypsum-Fiber Roof Board SA or APP- or APP-TA inch spans Poly Roofgrip#12 staggered center cyanurate TA rows f xF�e::r ,� 3 :`� .° t�"+�• 4'''',.;N':x4' �x� .: r "F-7 .,:«� �: -•a .,;..... ; �- wa.�:s,«,.y.:; �, w�•v...«..�-,.- .:.:..:a. ..w:. ,� • -f.-',1.,:e; � .s..:e±.c r,s 2 ,A,, ..n O i't .,; f� ,..-s1 ,xt µ fa e e c a rr.:0 "w`. .h..t� ...a. iy r:.f. .y ,;z41%.,-v-,1'.- .', ,:e; �a:. r< �. ,'��" �.'ea,$ 7� .'i?',. 9�. �� �.t 3,'�t�,d � v.. �,..�It fLL8 _Q DEC�(S. NEt"IV G[2NST 10 :�,( � `Gi; 0 Fp t�E. 41.:,i147'"'� .Ir ;c;.*9 x c .�. 'f�i.r}�.,}� :1+y fie+, .',? 4 i t „5�q�.`"., ^r 'uf.d, i0 : _ .. w � !.:Q � s.,. ' s.', .0 n�:y '`e °y, ;.:•...fid ,T.x. �.�.t.''.,y,y���:���rt 4��vf'i,r+y' �h v� `,��'{� ��v. ,�, ,.,7...G.!�.. .+ailt� ,��:' {.. ( # )7� .3 'E, you' T ,V+ 'm5. o r ea e `t .fof a �'*3` so=,':. r >t, p.:-t x. 14.,s.., .wq „�:.,� r: . .yN,_YSTFtiM�CE ,MECH1 CAk Y�AT4CAC ED SE,I !!_N 60 pED 70 NSCJLAT NiN, O DED R 0 R. r F , ,;�.•..1 ..«. �a� ......,a.�..rM..�,-..�.,M..,.....w,a.,.�+.,.,aw .c...4.• u,�...� ,e.,a:.w.es..w :-�Prt.. ,.a ...�.a..d,...�,.:�..+� .a..,...�re,,..�,r:,..h1,,. lr.-. .+�w`-„ , , System Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) MDP No. Deck(Note 1) Type Fasteners Attach Type Attach Base Ply Ply Cap Ply (psf) Min.0.75-inch FescoBoard (Optional If using Min.19/32-inch Min.1.5-inch Dekfast Hex with (Optional if W-7 plywood at max.24-inch ENRGY 3,H-Shield Dekfast#12 or TruFast 1 per (homogeneous)or min.0.5-inch AA Base)One or SBS-AA,SBS-TA, 1.33 ft2 Structodek High Density Fiberboard HA using AA Ply) more BP-AA or APP-TA -60.0 spans or Polytherm MP-3 with TruFast DP Roof Insulation BP AA APP-TA Exterior Research and Design,LLC.d/b/a Trinity)ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization#9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 2:09/25/2017 Prepared by: Robert Nieminen,PE-59166 TRI-BUILT Modified Bitumen Roof Systems;(800)516-1485 Appendix 1,Page 5 of 26 TRINITY I ERD t,.‘,0i«,, U.,1,,,,i v•�t,•;q�st.r ,r; t F ir i6.r, TWBBB��E2e �WGOpi«: S^ x,,..VIrCO ..S''''''.717."."4514 �RUiO� RSOF teAit O` oa w4 ER "` �'-t }l,:.: t •., t ,�T � • ,`� ... '�' 3r2L „ik4 , �0 , ft M "4 .. . ' ,, x;D�. GAH,DtNyj�� S' "'� •'?F rw. ,. "�. ' t� ' <1 a : ' kn. tALltt' rt,ng,57E l P:� �Q N ATLE. !.s? Asw � Gka. S.m.nEETBsQe E •0e0•CC .�� M. �, f", . t � ;�";:a+, ^•.-';'N 14- •+_".i.ri^ System Base Sheet Roof Cover(Note 15) MDP Deck(Note 1) No. Base Fasteners Attach Base Ply Cap Ply (psf) Polyglass Elastobase,Polyglass Elastobase Min.19/32-inch. OMG Flat Bottom Plates(square)with 12-inch o.c.in 4-inch lap and 12-inch (Optional)One or Poly,Polyglass G2 Base,CertainTeed SBS-AA,SBS- W-1 plywood at max. Glasbase,Firestone MB Base,JM Parma- Roofgrip#14,Dekfast Hex with Dekfast#14 o.c.in two,equally spaced,staggered more BP-AA or TA,APP-TA -52.5 24-inch spans Ply 28,Tamko Glass Base or GAFGLAS#75 or TruFast MP-3 with TruFast HD center rows APP-TA Min.19/32-Inch APP- Polyglass Elastobase or Polyglass Dekfast with Dekfast#14 or TruFast MP- 12-inch o.c.in 4-inch lap and 12-Inch One or more SBS- W-2 SBS-SA, plywood at max. * Elastobase Poly with poly top surface 3 with TruFast HD o.c.In two,equally spaced,staggered SA SA,SBS-TA or -52.5 24-inch spans center rows APP-TA Min.19/32-inch 12-inch o.c.in 4-inch lap and 12-Inch (Optional)One or W-3 plywood at max. Polyglass Elastobase or Polyglass OMG Flat Bottom Plates(square)with o.c.in two,equally spaced,staggered more BP-AA or SBS-AA,SBS- -60.0 24-inch spans Elastobase Poly Roofgrip#12 center rows APP-TA TA,APP-TA Min.19/32-inch 12-inch o.c.in 4-inch lap and 12-inch SBS-SA,W-4 plywood at max. APP- Polyglass Elastobase or Polyglass OMG Flat Bottom Plates(square)with o.c.in two,equally spaced,staggered One or more SBS- SA,SBS-TA or 60.0* 24-inch spans Elastobase Poly with poly top surface Roofgrip#12 center rows SA APP-TA �..Ia..i' � J ,..:u,�h Jluclk4*-.'.•11 ¢.t,��+,. „ro ,ki N„fa�„ c� ?:.,....i1,1.n441.d�., e..Y�'.F ,x .y. ax a,mm. �u1. ''i"+” � h- �«+u' �.d,.--.:,.,v,.-,� - k m 4 i"F;,..,r d t i ay #„ y 46,:E8 l _'v f" (h,jet;Ap`•S8ti� I' *€t 4; :4., a •tit a,a` `t.. ';,,,,i.> 7: ',Y .. I,°a�,P.tdr�>�'r>;r;?�,{ 4.�a >sa s+.t�, 1�,,,;y5 .�4 ,�.F .,.,tT?ABLE 1 .WO��D DEG�S NE�IUCO ST•�[�•1 T� 0 R OODD�'=(T At 0�'���5 •a ` t�', ��,.• �W;{r, ._r�•° - •� P„:41,aig5M 9 y:4:: d” 'f kai4� a ;T,..li4'' "+ ; .F.} 3�.a'+lt+ 14 y.a, ''' 'A.' `• 1,c�1' i` ,. iaac J.'F'. t r �.: 4 I;t,. { 5 ,M �` ,�.. _ '"&�" 1 „•3. .t ;{,°.t ' f•5 •.�� k3• y y .. S. f `i b,. r Rio}^e�' .a;, i�� r t y,!, w 1'�:th 7J r:. a� S ,,. • � � ,.,,a �!,t,, n.t, 1• r e 'N ,'•.. . k.x ,s.,t. a , �. , ,<, � s � + �' SVSTEM�TYP6�iF,iNQ�1 INS D B DkDpQOFC� ,ER "�� . �t •:�'.c.:, x ,, .a' � Ft,�t .c._e.'�':. �..,� �,�L ,...,.. ..,,�„a.....,d4,.i�.r k,.t f„i.,. ,,c:..,.,..54:.�k.L5.4:...,..fir .z r.... i,.'k,_..�...dnt,. 1.ui.y.n �.,, ,a,_,�,.. n.r.,r.wro E......�:z...._�e. ...'S '.u4.. ,..,.daw ,.++.»...,.a,:Arc.9,.,d+..a.,r.s&_.M..l..a......, :,r.,. . . •Y. �. . r d. System Deck Primer Roof Cover(Note 15) MDP No. Joint Treatment Base Ply Ply Cap Ply (Psf) W 5 Min.15/32-inch plywood (Optional)ASTM D41 None SBS-SA (Optional)SBS-SA or SBS-SA,APP-SA,SBS-TA•-•.•'\A''..--- -90.0 at max.24-Inch spans APP-TA or APP-TA W 6 Min.15/32-inch plywood (Optional)ASTM D41 Plywood joints are covered with 4-inch wide strips of TriBuilt SA TriBuilt SA SBS Base (Optional)SBS-SA or SBS-SA,APP-SA,SBS-TA -97.5 at max.24-Inch spans SBS Base,rolled into place to create continuous bond. APP-TA or APP-TA Exterior Research and Design,LLC.d/b/a Trinity)ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization#9503 6T”EDITION(2017)FBC NON-HVHZ EVALUATION Revision 2:09/25/2017 Prepared by: Robert Nieminen,PE-59166 TRI-BUILT Modified Bitumen Roof Systems;(800)516-1485 Appendix 1,Page 8 of 26