Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 3 'srt �' a f SCIS Home Log In�i User Registration I Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map i Links Search i riDli(1� I Product Approval - USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL12328-118 Application Type Revision Code Version 2017 Application Status Approved LM Comments Archived Product Manufacturer TAMKO Building Products,Inc, Address/Phone/Email PO Box 1404 MW M Joplin,MO 64802 (417)624-6644 Ext 23FILL kerri—eden@tamko.com L; Authorized Signature Kerri Eden kern eden@tamlco.com Technical Representative Kerri Eden Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerTLeden@tamko.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a licensed Florida Professional Engineer -7 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/18/2021 Validated By Locke Bowden P.E. W Validation Checklist-Hardcopy Received Certificate of Independence FLz12328 R8 COI TBP14001.4 2017 FBC Eval Report TAMKO Underlavments final.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D226 2009 ASTM D4869 2016 ASTM D6380 2003 TAS 103 1995 Equivalence of Product Standards Certified By Sections from the Code http://www.floridabuilding.org/nr/pr_app dtl.aspx?param=wGEVXQwtDgtF2Aezuar cr ... 12/11/2018 Florida Building Code Online Page 2 of 3 Product Approval Method Method 1 Option D Date Submitted 10/05/2017 Date Validated 10/19/2017 Date Pending FBC Approval 10/20/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 12328.1 ASTM Slate Surfaced Roll Roofing Roll roofing surfaced with mineral granules Limits of Use Installation Instructions Approved for use in HVHZ:YesF�12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO Approved for use outside HVHZ:Yes Underlayments final.pdf Impact Resistant:N/A Verified By:Zachary R.Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO Underlayments finalpdf Created by Independent Third Party:Yes 12328.2 ASTM Tile Underlayment Coated organic undedayment Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL12328_R8 II TBP14001.4 2017 FBC Eva]Report TAMKO Approved for use outside HVHZ:Yes Underlayments final.odf Impact Resistant:N/A Verified By:Zachary R.Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO Underiavments final. df Created by Independent Third Party:Yes 12328.3 Master Smooth Asphalt saturated organic underlayment. Limits of Use Installation Instructions Approved for use in HVHZ:No FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO Approved for use outside HVHZ:Yes Underlayments finalpdf Impact Resistant:N/A Verified By:Zachary R.Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328L RS AE TBP14001.4 2017 FBC Eval Report TAM KO Underlayments finalpdf Created by Independent Third Party:Yes 12328.4 Moisture Guard A self-adhering modified bitumen underlayment. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL12328 RS II TBP14001.4 2017 FBC Eva[Report TAMKO Approved for use outside HVHZ:Yes Underlayments finalpdf Impact Resistant:N/A Verified By:Zachary R.Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO Underlayments final.pd Created by Independent Third Party:Yes 12328.5 No. 15 ASTM Asphalt saturated organic felt Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL12328 R8 11 TBP14001-4 2017 FBC Eval Report TAMKO Approved for use outside HVHZ:Yes Underlayments final.pd Impact Resistant:N/A Verified By:Zachary R.Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eva[Report TAMKO Underlayments finai.pdf Created by Independent Third Party:Yes 12328.6 No.15 UL Asphalt saturated organic felt Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL12328 R8 11 TBP14001.4 2017 FBC Eva[Report TAMKO Approved for use outside HVHZ:Yes Underlayments final.pddf Impact Resistant:N/A Verified By:Zachary R.Priest 74021 Design Pressure:N/A- Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO http://www.floridabuilding.orL-/pr/ ii app_dtl.aspx?param=wGEVXQwtDgtF2AezuarjgO... 12/11/2018 Florida Building Code Online Page 3 of 3 Underlayments final.pdf Created by Independent Third Party:Yes 12328.7 No.30 ASTM Asphalt saturated organic felt Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL12328 R8 IT TBP14001.4 2017 FBC Eval Report TAMKO Approved for use outside HVHZ:Yes Underly nts final. df Impact Resistant:N/A Verified By:Zachary R. Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Resort TAMKO Underlavments final.pdf Created by Independent Third Party:Yes 12328.8 No.30 UL Asphalt saturated organic felt Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO Approved for use outside HVHZ:Yes Underly ments final.pdf Impact Resistant:N/A Verified By:Zachary R.Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO Un rlgyments final.pdf Created by Independent Third Party:Yes 12328.9 TAM-FELT Alternate to ASTM D 226,Type II underlayment Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL12328 R8 II TBP14001.4 2017 FBC Eva[Report TAMKO Approved for use outside HVHZ:Yes Underlavments final.pdf Impact Resistant:N/A Verified By:Zachary R.Priest PE-74021 Design Pressure: N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO Underlavments final.pdf Created by Independent Third Party:Yes 12328.10 TW Metal and Tile Underlayment self-adhering modified bitumen underlayment Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL12328 R8 It TBP14001 4 2017 FBC Eval Report TAMKO Approved for use outside HVHZ:Yes Underlavments final.pdf Impact Resistant:N/A Verified By:Zachary R.Priest 74021 Design Pressure: N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO Underlavments ffnai.odf Created by Independent Third Party:Yes 12328.11 TW Underlayment self-adhering modified bitumen underlayment Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL12328_R8 II TBP14001.4 2017 FBC Eval Resort TAMKO Approved for use outside HVHZ:Yes Under[aymeno final.pdf Impact Resistant:N/A Verified By:Zachary R. Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 RS AE TBP14001.4 2017 FBC Eval ReportTAMKO Underlaymgnts final.ydf Created by Independent Third Party:Yes Back .---I Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an ANEW employer.copyright 2007-201.3 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: "= � Eery; Credit Card — Safe H. ri4�1 ti 1&7 http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGE VXQwtDgtF2Aezuad gO... 12/11/2018 -- E'K Certificate of Authorization No. 29824 CE 17520 Edinburgh Drive Tampa, FL 33647 f.. TF-cH ICAL SF-RvicEs, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,6T"EDITION(2017) Manufacturer: TAMKO BUILDING PRODUCTS, INC. Issued October 19, 2017 P.O. Box 1404 Joplin, MO 64802 (417)624-6644 hftp:/Iwww.tamko.com Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.1.1 Properties: Physical properties PRODUCT DESCRIPTION TAMKO®ASTM Slate ASTM D 6380, Class M,Type II underlayment constructed from organic felt saturated Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules. TAMKO®ASTM Tile ASTM D 6380, Class M,Type I I underlayment constructed from an organic felt saturated Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules. TAMKO®Master ASTM D 6380, Class S,Type IV underlayment constructed from an organic feltsaturated smooth with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For use in non-HVHZ only. TAMKO®Moisture Self-adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane Guard® with a mineral surfacing and a removable release film on the adhesive side and removable selvedge release tape. TAMKO®No.15 ASTM ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt Organic Felt TAMKOO No. 15 UL ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt Organic Felt TAMKOO No.30 ASTM ASTM D 226,Type II underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt TAMKO®No.30 UL ASTM D 226,Type 11 underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt Organic Felt TAMKO®TW Metal and Self-adhered,flexible,ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side. i TAMKOO TW Self-adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a Underlayment polymerfilm on the surface and a removable release film on the adhesive side. TBP14001.4 FL12328-R8 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use, or other product attributes that are not specifically addressed herein. TAMKO BUILDING PRODCUTS,INC. TAMKO Underlayments TECHNICAL SERVICES. LLC TAMKO®TAM-FELT Alternate to ASTM D 226,Type I and Type II underlayment constructed from a non- perforated organic felt that is saturated with asphalt. APPLICATION METHOD Installation shall be in accordance with the published manufacturers installation instructions, the FBC, and the requirements below. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting joints. The minimum application temperature shall be 50°F except as follows: a) The minimum application temperature of TAMKO®TW Metal and Tile Underlayment and TAMKOOTW Underlayment shall be 40°F. b) The minimum application temperature of TAMKOO Moisture Guard®shall be 35°F. The minimum roof slope shall be in accordance with FBC requirements except as follows: a) The minimum slope of TAMKOO ASTM Slate Surfaced Roll Roofing shall be 2:12. Underlayments shall be exposed in accordance with the manufacturer's recommendations, but in no case shall exposure exceed 30 days. Exception: TAMKOO TW Metal and Tile Underlayment may be exposed for a maximum 90 days. Self-adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ. All roof coverings shall be mechanically fastened through the underlayment to the roof deck. Allowable Roof Coverings: Metal Roof Mineral -Wood Asphalt Panels and Surfaced Roll Shingles and Slate Clay and Underlayment Shingles Shingles Roofing Shakes Shingles Concrete Tile TAMKOO ASTM Slate Y1 N N N N Y Surfaced Roll Roofing TAMKOO ASTM Tile N N N N N Y Underlayment TAMKOO Master Smooth Y1 N N N N N TAMKOO Moisture GuardO Y N N N N N TAMKOO No.15 ASTM Asphalt Saturated Organic Y Y Y Y2 N N Felt TAMKOO No. 15 UL Asphalt Y Y Y YZ Y N Saturated Organic Felt TAMKOO No.30 ASTM Asphalt Saturated Organic Y Y Y Y Y Y Felt TAMKOO No.30 UL Asphalt Y Y Y N Y N Saturated Organic Felt TAMKOO TW Metal and Tile Y Y N N N Y Underlayment TAMKOO TW Underlayment Y Y N N N N TAMKOO TAM-FELT Y N N N N N Notes: 1)Open valley applications per 1507.2.9.2 2)Wood shingles only TBP14001.4 FL12328-R8 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use, or other product attributes that are not specifically addressed herein. "�" TAMKO BUILDING PRODCUTS,INC. TAMKO Underlayments TECHNICAL SERVICES, LLC LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Wind uplift resistance in not within scope of this evaluation. 3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Contact the manufacturer when installing attemperatures below the minimum application temperature. 5) Unless otherwise stated,the minimum roof slope shall be in accordance with FBC requirements. 6) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped in successive courses installed up the deck in a manner that effectively sheds water from the deck End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 7) The underlayment may be used as described in other current FBC product approval documents. 8) The underlayment shall not be installed over existing roof coverings. 9) Contact the manufacturer regarding specific exposure limits for each underlayment. 10) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies(TST6049) TAP-192-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) TAP-193-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) TAP-214-02-01 ASTM D 4869 2016 PRI Construction Materials Technologies(TST6049) TAP-215-02-01 ASTM D 226 2009 PRI Construction Materials Technologies(TST6049) TAP-216-02-03 ASTM D 6380 2003(2013) PRI Construction Materials Technologies(TST6049) TAP-217-02-01 REV ASTM D 6380 2003(2013) PRI Construction Materials Technologies(TST6049) TAP-218-02-01 ASTM D 226 2009 PRI Construction Materials Technologies(TST6049) TAP-219-02-01 ASTM D 226 2009 PRI Construction Materials Technologies(TST6049) TAP-220-02-01 ASTM D 6380 2003(2013) PRI Construction Materials Technologies(TST6049) TAP-222-02-01 ASTM D 4869 2016 PRI Construction Materials Technologies(TST6049) TAP-245-02-01 TAS 103 1995 ASTM D 4798 2011 PRI Construction Materials Technologies(TST6049) TAP-311-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) TAP-319-02-01.1 ACC 188 2012 PRI Construction Materials Technologies(TST6049) TAP-387-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) TAP-388-02-01 ASTM D 1970 2015a UL LLC(fST9628) 13CA12269 ASTM D 226 2009 TBP14001.4 FI-12328-R8 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use, or other product attributes that are not specifically addressed herein. C "'°" " TAMKO BUILDING PRODCUTS,INC. ate_- TAMKO Underlayments TECHNICAL.SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6t'Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. Rp. G 2017 10019 � •E N SF/�s oo� No 74021 • '� �� 12:15:58 - 4 '041001 o13'. STATE OF :•4/: A`•'•'°< O Q:����: Zachary R.Priest, P.E. R 1 G %� Florida Registration No.74021 ,lit OnJq;Eeo Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product END OF DEPORT TBP14001.4 FL12328-R8 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. Florida Building Code Online Page 1 of 2 3i � � 4 �� k �a L.,..S, w__,..�.-...,✓r...`v-'..s.x � ...,s..-.,......�,ti_.:>,.�. �-...__._r....�.._.,...�`'",� .="l; x V l .,.�'.� ,.,`� a r '.:7 SCIS Home i Log In i User Registration = Hot Topics ? Submit Surcharge i Stats&Facts i Publications 1 FBC Staff 'BCIS Site Map Links Search i Product Approval ! i�• USER:Public User RECEIVED F Product Approval Menu>Product or Application Search>Application List>Application Detail ^z ^max FL# FL10674-R13 JAN 16 2019 Application Type Revision ST. Lucie County, Permitting Code Version 2017 Application Status Approved Comments - ff 1DV Archived FILL MR W Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscoming.com Authorized Signature Greg Keeler greg.keeler@owenscoming.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo,OH 43659 (419)376-8360 mel.sancrant@owenscomig.com Quality Assurance Representative Address/Phone/Email Category Rooting Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert J.M. Nleminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 05/16/2020 Validated By John W. Knezevich,PE ,./ Validation Checklist- Hardcopy Received Certificate of Independence FL10674 R13 COI 2017 01 COI Niemin-e Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2011 Equivalence of Product Standards Certified By Sections from the Code http://www.floridabuilding.org/pr/pr app_dtl.aspx?pararn=wGEVXQwtDgtBNbEY5V%2... 1/15/2018 Florida Building Code Online _ Page 2 of 2 Product Approval Method Method 1 Option D Date Submitted 10/10/2017 Date Validated 10/11/2017 Date Pending FBC Approval 10/15/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 10674.1 Owens Coming Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge Shingles and Starters shingles Limits of Use Installation Instructions Approved for use in HVHZ:No FL10674 R13 II 2017 10 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10674-R13.pdf Impact Resistant:N/A Verified By: Robert J.M. Nleminen PE-59166 Design Pressure:N/A Created by Independent Third Party:Yes Other: Refer to ER,Section S. Evaluation Reports FL10674 R13 AE 2017 10 FINAL ER OC ASPHALT SHINGLES FL10674-P,13.pdf Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: F-71 Ej 7i7 Ej Credit CaFd Sate http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wOEVXQwtDgtBNbEY5V%2... 1/15/2018 EXTERIOR RESEARCH&DESIGN, LLC. i - Certificate of Authorization#9503 i ! 353 CHRISTIAN STREET,UNIT#13 TRINITY.,•`. i ER OXFORD,CT 06478 (203)262-9245 EVALUATION REPORT Owens Corning Evaluation Report 03794b.02.12-R8 One Owens Corning Parkway FL10674-1113 Toledo,OH 43659 Date of Issuance:02/06/2012 (740)404-7829 Revision 8: 10/09/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6`h Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted. herein and FBC 1507.2.7.11 R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change, Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative'to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: „s«,rorrr", -- Vii..'•'�� Robert J.M.Nieminen,P.E. �1�, ThefaaimilesealappearingwasauthorizedbyRobert Florida Registration No.59166,Florida DCA ANE1983 ; •�hnnn�` Nieminen,P.E.on 10/09/2017.This does not serve as an electronically signed document CERTIFICATION OF INDEPENDENCE: 1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. ` 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. IR ED ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462. 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: gntpL Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04%18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties, Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance, Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: b b 4.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire'are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire'"'are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Durationb, TruDefinition® Durations, Duration' Premium Cool, TruDefinition® Duration Designer Color Collection, TruDefinition®Oakridge', Oakridge' and WeatherGuards HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Hp&Ridge Shingles: 4.2.1 Berkshireb Hip &Ridge Shingles, High Ridge, WeatherGuardD HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidgeTm Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Accessory Starter Strips: 4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 certificate of Authorization#9503 Gni EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 2 of 8 r _ 5.4 Wind Classification: 5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for use in all wind zones up to Vasd = 150 mph (V„lt = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasa=150 mph (Vult=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C,as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: Berkshireo shingles require minimum five(5)nails per shingle. ➢ WeatherGuard'HP shingles require minimum six(6)nails per shingle. ➢ Devonshire*"shingles require minimum six(6)nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not-less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Felt underlayment -. Deck Fettundedayment a_ Deck Self-adl+ered 4tieatherl ock7 Self-adhered Vic• undedaymerd '- WeatherLocka -r/ underlayment l! Drip— Drip edge Drip— -f Dnp edge edge i edge Nails located - located .ice `2'-3'from save 2=3"Irom save Install rust Self-sealing adhesive SeHae4ng adhesiva StarterSlrlp �. position, along eave mjg�firanrst 5avedrS�pPtx % PwAlonedabngeave shingle vdth '. G'removed Starter Strip f ingle overhangs eaves and rakes Starter Strip Plus overhangs eaves and rakes 114t-3/4' Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS Certificate of Authorization#9503 6EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 3 of 8 I -ry }CR 6.2.6 Minimum Nailing—Classic°&Supreme: Normal Mansard or Area porn Normal Mansard or Area porn Wind Areas High Wind desvanes y Wind Areas High Wind desysnes y Area pars vientoa normales Areas vientos fuerte9 Area pare vlentas normales Areas vientos fuertes r IAI r,.. z- (B) ,r ,r � .-,2,s� —t2t � I• 5"Exposure 5 5/8'Exposure Exposition Exposition 6.2.7 Minimum Nailing—Berkshire®: Sealara strip Seaf ant strip La tlra da saliador La tlu de sellador 1' Fr,w 9 9 Vt 9 b't' �,.8 Vz" 8+h" 8;Y, 8+Y r Standard Fastening Pattern 6-Nail Fastening Pattern Sealam strip La tlra desJlatbr 04--30 C-->• e i---�Y D 4-�D D A A 2 e _MPI, cement Cemsnto do forho do asfaho Mansard or Steep Slope Fastening Pattern Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-RS Certiflcate ofAuthorizatlon#9503 6'EDITION(2017)FBC NOM-HVHZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 4 of 8 k�. 6.2.8 Minimum Nailing—Devonshire`": Na , Cla•+as Nails 1 5.5/8"exposure >1: 4-------1 �� �a `+•, _I:.. Exposieidn de 5-5/8 pulg Sealant location Ubieaeion del sellador Ten V Spots of Asphalt Roof Cement Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing — Duration®, TruDefinitionO Duration, Duration® Premium Cool & TruDefinition' e Duration Designer Color Collection: 4-Nail Fastening Pattern 6-Nall Fastening Pattern sun,N,10fastonmg ueae itlM suroNalFfllastenllg nreawidth hail.TyFlwl Noll rypleal t 127 12 1^ 5 12 12 t --� I�-----.I s-ua-I�ea � 6118Lt--F—1 F.'.,.- R Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Greater Than 21:12 SutaNanq fastening araa aimh WU,lypi. •j r ' FOR}V Spots n1 AspnaR Roota,g eemart Mansard or Steep Slope Fastening Pattern i Euterior Research and.Design,I.I.C. Evaluation Report 037940.02.12-RS Certificate of Authorization#9503 6'EDITION(2017)Fac NON-HVHZ EVALUATION FL10674-R13 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 5 of 8 t _ ERE$ RINI Y, ✓ 6.2.1 Minimum Nailing—Tru Definition40akridgell,Oakridge®: 4 Nail Pattern 6 Nail Pattern 6quema can d clavas Esquema con 6 Clavas 1• 1 r r I� 12' rr 12 6618"ExposureMRS6516"Expose Hails 5rpos/d6a do 6518padg. Clapos Exposleidn do 6618 pdg. 6 6i8"Exposure Clavas 5 6/8"Exposure Exponcfdn da 5618pulg. Fxposfavn de 5518putg. Standard Fastening Pattern 6-Nail Fastening Pattern FastenVng for Slopes Greater Than 21:12 S..N.Itn I.Wni"nlen width F H-`- ail w"' 1 12 I 1 12^ 7" e41s i•� �2 Four r"Spots of Mph&Roofing Centont Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing—WeatherGuard®HP: r 7• �� �� 4 �O"gia l�— 7`—� 12� WSW latww � Firftnw7hnru&lUsll Bli10 Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certiflcate oJAuthorization#9503 6m EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 6 of 8 TRI. x ER 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard6 HP Hip and Ridge Shingles and ProEdge Ilip & Ridge Shingles shall comply with the Owens Corning current published instructions, using four (4) nails per shingle. Installation of DuraRidgexa' Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—BerkshireO Hip&Ridge and High Ridge: Fig.1 Fig.2 Direction n Taprlil.5v SiJeYer trails ` \\'Q Nals1 Nails s TOP Piece z! 1 S' ti 1 1 1 1 I- 6—D1 p•• �I 14 6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge: A Fi Fig.C Hip&Ridge Shingle Fastening . g' 9¢_Pla^alNngvltntl � � TopVkw Dlrectbn p\ flails Nails- 2"2" R-P I 1. A I I i I ��T�-a • \ 1 1 I Is „II Y TY V I II I" Exposure �� Exposure la _ ,z" Exterior Research and Design,LLC. Evaluation Report 037940.02.12-118 Certificate of Authorization 119503 6'EDITION(2017)FBC NON-HVFIZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 7 of 8 6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard Wind DirectionFastoning Sco9ant Strip Pattern 27— 6°Exposure ! 1"-I 12° 1 Sealant YI Fasten 71' 7 it=' 6°Exposure Cover Exposed 1 1 _ Fastaners with Roof Cement t . 6.3.6 Minimum Nailing—DuraRidge'm Hip&Ridge Shingles: Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. Pro+aiEFiWird Qirccdm Tip View a—Diroaianddrnimnta.4.s sc+se Vue en plm Diracd6ndol rimtDpradcmirunta 11" Vista=u 'Z' NA clau :ti _ n 5a 'osY'rss Coshing Suret-0ail•--- caw, ti ty I a. L I I I I «lay rEg�sss V ILL 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in,order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for,information on which plants produce products covered by Florida Rule 9N-3 CW requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—CLUA9625;(631)546-2458;Kanchi.Agrawala-Dokania@ul.com - END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS Certificate of Authorization 119303 6'EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 8 of 8