FL# FL12328-118
Application Type Revision
Code Version 2017
Application Status Approved
LM
Comments
Archived
Product Manufacturer TAMKO Building Products,Inc,
Address/Phone/Email PO Box 1404 MW M
Joplin,MO 64802
(417)624-6644 Ext 23FILL
kerri—eden@tamko.com L;
Authorized Signature Kerri Eden
kern eden@tamlco.com
Technical Representative Kerri Eden
Address/Phone/Email PO Box 1404
Joplin,MO 64802
(417)624-6644 Ext 2305
kerTLeden@tamko.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a licensed
Florida Professional Engineer
-7 Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/18/2021
Validated By Locke Bowden P.E.
W Validation Checklist-Hardcopy Received
Certificate of Independence FLz12328 R8 COI TBP14001.4 2017 FBC Eval Report TAMKO
Underlavments final.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D226 2009
ASTM D4869 2016
ASTM D6380 2003
TAS 103 1995
Equivalence of Product Standards
Certified By
Sections from the Code
http://www.floridabuilding.org/nr/pr_app dtl.aspx?param=wGEVXQwtDgtF2Aezuar cr ... 12/11/2018
Florida Building Code Online Page 2 of 3
Product Approval Method Method 1 Option D
Date Submitted 10/05/2017
Date Validated 10/19/2017
Date Pending FBC Approval 10/20/2017
Date Approved 12/12/2017
Summary of Products
FL# Model,Number or Name Description
12328.1 ASTM Slate Surfaced Roll Roofing Roll roofing surfaced with mineral granules
Limits of Use Installation Instructions
Approved for use in HVHZ:YesF�12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ:Yes Underlayments final.pdf
Impact Resistant:N/A Verified By:Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments finalpdf
Created by Independent Third Party:Yes
12328.2 ASTM Tile Underlayment Coated organic undedayment
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328_R8 II TBP14001.4 2017 FBC Eva]Report TAMKO
Approved for use outside HVHZ:Yes Underlayments final.odf
Impact Resistant:N/A Verified By:Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underiavments final. df
Created by Independent Third Party:Yes
12328.3 Master Smooth Asphalt saturated organic underlayment.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ:Yes Underlayments finalpdf
Impact Resistant:N/A Verified By:Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328L RS AE TBP14001.4 2017 FBC Eval Report TAM KO
Underlayments finalpdf
Created by Independent Third Party:Yes
12328.4 Moisture Guard A self-adhering modified bitumen underlayment.
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 RS II TBP14001.4 2017 FBC Eva[Report TAMKO
Approved for use outside HVHZ:Yes Underlayments finalpdf
Impact Resistant:N/A Verified By:Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pd
Created by Independent Third Party:Yes
12328.5 No. 15 ASTM Asphalt saturated organic felt
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 11 TBP14001-4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ:Yes Underlayments final.pd
Impact Resistant:N/A Verified By:Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eva[Report TAMKO
Underlayments finai.pdf
Created by Independent Third Party:Yes
12328.6 No.15 UL Asphalt saturated organic felt
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 11 TBP14001.4 2017 FBC Eva[Report TAMKO
Approved for use outside HVHZ:Yes Underlayments final.pddf
Impact Resistant:N/A Verified By:Zachary R.Priest 74021
Design Pressure:N/A- Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
http://www.floridabuilding.orL-/pr/ ii app_dtl.aspx?param=wGEVXQwtDgtF2AezuarjgO... 12/11/2018
Florida Building Code Online Page 3 of 3
Underlayments final.pdf
Created by Independent Third Party:Yes
12328.7 No.30 ASTM Asphalt saturated organic felt
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 IT TBP14001.4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ:Yes Underly nts final. df
Impact Resistant:N/A Verified By:Zachary R. Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Resort TAMKO
Underlavments final.pdf
Created by Independent Third Party:Yes
12328.8 No.30 UL Asphalt saturated organic felt
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ:Yes Underly ments final.pdf
Impact Resistant:N/A Verified By:Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Un rlgyments final.pdf
Created by Independent Third Party:Yes
12328.9 TAM-FELT Alternate to ASTM D 226,Type II underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 II TBP14001.4 2017 FBC Eva[Report TAMKO
Approved for use outside HVHZ:Yes Underlavments final.pdf
Impact Resistant:N/A Verified By:Zachary R.Priest PE-74021
Design Pressure: N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlavments final.pdf
Created by Independent Third Party:Yes
12328.10 TW Metal and Tile Underlayment self-adhering modified bitumen underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 It TBP14001 4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ:Yes Underlavments final.pdf
Impact Resistant:N/A Verified By:Zachary R.Priest 74021
Design Pressure: N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlavments ffnai.odf
Created by Independent Third Party:Yes
12328.11 TW Underlayment self-adhering modified bitumen underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328_R8 II TBP14001.4 2017 FBC Eval Resort TAMKO
Approved for use outside HVHZ:Yes Under[aymeno final.pdf
Impact Resistant:N/A Verified By:Zachary R. Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328 RS AE TBP14001.4 2017 FBC Eval ReportTAMKO
Underlaymgnts final.ydf
Created by Independent Third Party:Yes
Back .---I
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an ANEW employer.copyright 2007-201.3 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
click here.
Product Approval Accepts:
"= � Eery;
Credit Card —
Safe
H. ri4�1 ti 1&7
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGE VXQwtDgtF2Aezuad gO... 12/11/2018
-- E'K
Certificate of Authorization No. 29824
CE
17520 Edinburgh Drive
Tampa, FL 33647
f.. TF-cH ICAL SF-RvicEs, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,6T"EDITION(2017)
Manufacturer: TAMKO BUILDING PRODUCTS, INC. Issued October 19, 2017
P.O. Box 1404
Joplin, MO 64802
(417)624-6644
hftp:/Iwww.tamko.com
Quality Assurance: UL LLC(QUA9625)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507.1.1
Properties: Physical properties
PRODUCT DESCRIPTION
TAMKO®ASTM Slate ASTM D 6380, Class M,Type II underlayment constructed from organic felt saturated
Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules.
TAMKO®ASTM Tile ASTM D 6380, Class M,Type I I underlayment constructed from an organic felt saturated
Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules.
TAMKO®Master ASTM D 6380, Class S,Type IV underlayment constructed from an organic feltsaturated
smooth with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For
use in non-HVHZ only.
TAMKO®Moisture Self-adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane
Guard® with a mineral surfacing and a removable release film on the adhesive side and
removable selvedge release tape.
TAMKO®No.15 ASTM ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt
Organic Felt
TAMKOO No. 15 UL ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt
Organic Felt
TAMKOO No.30 ASTM ASTM D 226,Type II underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKO®No.30 UL ASTM D 226,Type 11 underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt
Organic Felt
TAMKO®TW Metal and Self-adhered,flexible,ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane
Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side. i
TAMKOO TW Self-adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a
Underlayment polymerfilm on the surface and a removable release film on the adhesive side.
TBP14001.4 FL12328-R8 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation,recommended use, or other product attributes that are not
specifically addressed herein.
TAMKO BUILDING PRODCUTS,INC.
TAMKO Underlayments
TECHNICAL SERVICES. LLC
TAMKO®TAM-FELT Alternate to ASTM D 226,Type I and Type II underlayment constructed from a non-
perforated organic felt that is saturated with asphalt.
APPLICATION METHOD
Installation shall be in accordance with the published manufacturers installation instructions, the FBC, and the
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be
checked for protrusion and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting
joints.
The minimum application temperature shall be 50°F except as follows:
a) The minimum application temperature of TAMKO®TW Metal and Tile Underlayment and TAMKOOTW
Underlayment shall be 40°F.
b) The minimum application temperature of TAMKOO Moisture Guard®shall be 35°F.
The minimum roof slope shall be in accordance with FBC requirements except as follows:
a) The minimum slope of TAMKOO ASTM Slate Surfaced Roll Roofing shall be 2:12.
Underlayments shall be exposed in accordance with the manufacturer's recommendations, but in no case shall
exposure exceed 30 days.
Exception: TAMKOO TW Metal and Tile Underlayment may be exposed for a maximum 90 days.
Self-adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ.
All roof coverings shall be mechanically fastened through the underlayment to the roof deck.
Allowable Roof Coverings:
Metal Roof Mineral -Wood
Asphalt Panels and Surfaced Roll Shingles and Slate Clay and
Underlayment Shingles Shingles Roofing Shakes Shingles Concrete Tile
TAMKOO ASTM Slate Y1 N N N N Y
Surfaced Roll Roofing
TAMKOO ASTM Tile N N N N N Y
Underlayment
TAMKOO Master Smooth Y1 N N N N N
TAMKOO Moisture GuardO Y N N N N N
TAMKOO No.15 ASTM
Asphalt Saturated Organic Y Y Y Y2 N N
Felt
TAMKOO No. 15 UL Asphalt Y Y Y YZ Y N
Saturated Organic Felt
TAMKOO No.30 ASTM
Asphalt Saturated Organic Y Y Y Y Y Y
Felt
TAMKOO No.30 UL Asphalt Y Y Y N Y N
Saturated Organic Felt
TAMKOO TW Metal and Tile Y Y N N N Y
Underlayment
TAMKOO TW Underlayment Y Y N N N N
TAMKOO TAM-FELT Y N N N N N
Notes: 1)Open valley applications per 1507.2.9.2
2)Wood shingles only
TBP14001.4 FL12328-R8 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation,recommended use, or other product attributes that are not
specifically addressed herein.
"�" TAMKO BUILDING PRODCUTS,INC.
TAMKO Underlayments
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance in not within scope of this evaluation.
3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Contact the manufacturer when installing attemperatures below the minimum application temperature.
5) Unless otherwise stated,the minimum roof slope shall be in accordance with FBC requirements.
6) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped
in successive courses installed up the deck in a manner that effectively sheds water from the deck End
laps shall be staggered between courses in accordance with the manufacturer's application instructions.
7) The underlayment may be used as described in other current FBC product approval documents.
8) The underlayment shall not be installed over existing roof coverings.
9) Contact the manufacturer regarding specific exposure limits for each underlayment.
10) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
REFERENCES
Entity Report No. Standard Year
PRI Construction Materials Technologies(TST6049) TAP-192-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-193-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-214-02-01 ASTM D 4869 2016
PRI Construction Materials Technologies(TST6049) TAP-215-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-216-02-03 ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-217-02-01 REV ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-218-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-219-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-220-02-01 ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-222-02-01 ASTM D 4869 2016
PRI Construction Materials Technologies(TST6049) TAP-245-02-01 TAS 103 1995
ASTM D 4798 2011
PRI Construction Materials Technologies(TST6049) TAP-311-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-319-02-01.1 ACC 188 2012
PRI Construction Materials Technologies(TST6049) TAP-387-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-388-02-01 ASTM D 1970 2015a
UL LLC(fST9628) 13CA12269 ASTM D 226 2009
TBP14001.4 FI-12328-R8 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation,recommended use, or other product attributes that are not
specifically addressed herein.
C
"'°" " TAMKO BUILDING PRODCUTS,INC.
ate_- TAMKO Underlayments
TECHNICAL.SERVICES, LLC
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 6t'Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer.
Rp.
G 2017 10019
� •E N SF/�s oo�
No 74021 • '� �� 12:15:58
- 4 '041001
o13'. STATE OF :•4/:
A`•'•'°< O Q:����: Zachary R.Priest, P.E.
R 1 G %� Florida Registration No.74021
,lit
OnJq;Eeo Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product
END OF DEPORT
TBP14001.4 FL12328-R8 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
Florida Building Code Online Page 1 of 2
3i � � 4
��
k �a
L.,..S, w__,..�.-...,✓r...`v-'..s.x � ...,s..-.,......�,ti_.:>,.�. �-...__._r....�.._.,...�`'",� .="l; x V l .,.�'.� ,.,`� a r '.:7
SCIS Home i Log In i User Registration = Hot Topics ? Submit Surcharge i Stats&Facts i Publications 1 FBC Staff 'BCIS Site Map Links Search i
Product Approval
! i�• USER:Public User RECEIVED
F
Product Approval Menu>Product or Application Search>Application List>Application Detail
^z ^max FL# FL10674-R13 JAN 16 2019
Application Type Revision ST. Lucie County, Permitting
Code Version 2017
Application Status Approved
Comments - ff 1DV
Archived FILL
MR W
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscoming.com
Authorized Signature Greg Keeler
greg.keeler@owenscoming.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo,OH 43659
(419)376-8360
mel.sancrant@owenscomig.com
Quality Assurance Representative
Address/Phone/Email
Category Rooting
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M. Nleminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/16/2020
Validated By John W. Knezevich,PE
,./ Validation Checklist- Hardcopy Received
Certificate of Independence FL10674 R13 COI 2017 01 COI Niemin-e
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2016
ASTM D3462 2010
ASTM D7158 2011
Equivalence of Product Standards
Certified By
Sections from the Code
http://www.floridabuilding.org/pr/pr app_dtl.aspx?pararn=wGEVXQwtDgtBNbEY5V%2... 1/15/2018
Florida Building Code Online _ Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 10/10/2017
Date Validated 10/11/2017
Date Pending FBC Approval 10/15/2017
Date Approved 12/12/2017
Summary of Products
FL# Model,Number or Name Description
10674.1 Owens Coming Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge
Shingles and Starters shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL10674 R13 II 2017 10 FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-R13.pdf
Impact Resistant:N/A Verified By: Robert J.M. Nleminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other: Refer to ER,Section S. Evaluation Reports
FL10674 R13 AE 2017 10 FINAL ER OC ASPHALT
SHINGLES FL10674-P,13.pdf
Created by Independent Third Party:Yes
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emalis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
F-71 Ej 7i7 Ej
Credit CaFd
Sate
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wOEVXQwtDgtBNbEY5V%2... 1/15/2018
EXTERIOR RESEARCH&DESIGN, LLC.
i - Certificate of Authorization#9503
i ! 353 CHRISTIAN STREET,UNIT#13
TRINITY.,•`. i ER OXFORD,CT 06478
(203)262-9245
EVALUATION REPORT
Owens Corning Evaluation Report 03794b.02.12-R8
One Owens Corning Parkway FL10674-1113
Toledo,OH 43659 Date of Issuance:02/06/2012
(740)404-7829 Revision 8: 10/09/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6`h Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted.
herein and FBC 1507.2.7.11 R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change,
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete
review of this Evaluation Report relative'to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by: „s«,rorrr", --
Vii..'•'��
Robert J.M.Nieminen,P.E. �1�, ThefaaimilesealappearingwasauthorizedbyRobert
Florida Registration No.59166,Florida DCA ANE1983 ;
•�hnnn�` Nieminen,P.E.on 10/09/2017.This does not serve as an
electronically signed document
CERTIFICATION OF INDEPENDENCE:
1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product. `
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
IR ED
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated
compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462. 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
3. REFERENCES:
gntpL Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04%18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties, Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance, Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
b b
4.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire'are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshire'"'are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Durationb, TruDefinition® Durations, Duration' Premium Cool, TruDefinition® Duration Designer Color
Collection, TruDefinition®Oakridge', Oakridge' and WeatherGuards HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hp&Ridge Shingles:
4.2.1 Berkshireb Hip &Ridge Shingles, High Ridge, WeatherGuardD HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidgeTm Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 Accessory Starter Strips:
4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
certificate of Authorization#9503 Gni EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 2 of 8
r _
5.4 Wind Classification:
5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable
for use in all wind zones up to Vasd = 150 mph (V„lt = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for use in all wind zones up to Vasa=150 mph (Vult=194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C,as defined in FBC 1609.4.3, and a mean
roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following
exceptions:
Berkshireo shingles require minimum five(5)nails per shingle.
➢ WeatherGuard'HP shingles require minimum six(6)nails per shingle.
➢ Devonshire*"shingles require minimum six(6)nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not-less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
Felt underlayment -. Deck Fettundedayment a_ Deck Self-adl+ered
4tieatherl ock7
Self-adhered Vic• undedaymerd
'- WeatherLocka -r/
underlayment l!
Drip— Drip edge Drip— -f Dnp edge
edge i edge
Nails located - located
.ice `2'-3'from save
2=3"Irom save
Install rust Self-sealing adhesive SeHae4ng adhesiva
StarterSlrlp �. position, along eave mjg�firanrst 5avedrS�pPtx % PwAlonedabngeave
shingle vdth '.
G'removed
Starter Strip f ingle overhangs eaves and rakes Starter Strip Plus overhangs eaves and rakes 114t-3/4'
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS
Certificate of Authorization#9503 6EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 3 of 8
I -ry
}CR
6.2.6 Minimum Nailing—Classic°&Supreme:
Normal Mansard or Area porn Normal Mansard or Area porn
Wind Areas High Wind desvanes y Wind Areas High Wind desysnes y
Area pars vientoa normales Areas vientos fuerte9 Area pare vlentas normales Areas vientos fuertes
r IAI r,.. z- (B)
,r ,r � .-,2,s� —t2t � I•
5"Exposure 5 5/8'Exposure
Exposition Exposition
6.2.7 Minimum Nailing—Berkshire®:
Sealara strip Seaf ant strip
La tlra da saliador La tlu de sellador
1'
Fr,w
9 9 Vt 9 b't' �,.8 Vz" 8+h" 8;Y, 8+Y
r
Standard Fastening Pattern 6-Nail Fastening Pattern
Sealam strip
La tlra desJlatbr
04--30 C-->• e i---�Y D 4-�D D
A
A
2 e _MPI, cement
Cemsnto do forho do asfaho
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-RS
Certiflcate ofAuthorizatlon#9503 6'EDITION(2017)FBC NOM-HVHZ EVALUATION F1.10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 4 of 8
k�.
6.2.8 Minimum Nailing—Devonshire`":
Na ,
Cla•+as
Nails
1 5.5/8"exposure >1: 4-------1 �� �a `+•, _I:..
Exposieidn de 5-5/8 pulg Sealant location
Ubieaeion del sellador
Ten V Spots of Asphalt Roof Cement
Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing — Duration®, TruDefinitionO Duration, Duration® Premium Cool & TruDefinition'
e
Duration Designer Color Collection:
4-Nail Fastening Pattern 6-Nall Fastening Pattern
sun,N,10fastonmg ueae itlM suroNalFfllastenllg nreawidth
hail.TyFlwl Noll rypleal
t 127 12 1^ 5 12 12 t
--� I�-----.I
s-ua-I�ea � 6118Lt--F—1 F.'.,.- R
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Slopes Greater Than 21:12
SutaNanq fastening araa aimh
WU,lypi.
•j r
' FOR}V Spots n1 AspnaR Roota,g eemart
Mansard or Steep Slope Fastening Pattern
i
Euterior Research and.Design,I.I.C. Evaluation Report 037940.02.12-RS
Certificate of Authorization#9503 6'EDITION(2017)Fac NON-HVHZ EVALUATION FL10674-R13
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 5 of 8
t _ ERE$
RINI Y,
✓ 6.2.1 Minimum Nailing—Tru Definition40akridgell,Oakridge®:
4 Nail Pattern 6 Nail Pattern
6quema can d clavas Esquema con 6 Clavas
1• 1
r r
I� 12' rr 12
6618"ExposureMRS6516"Expose Hails
5rpos/d6a do 6518padg. Clapos Exposleidn do 6618 pdg. 6 6i8"Exposure Clavas 5 6/8"Exposure
Exponcfdn da 5618pulg. Fxposfavn de 5518putg.
Standard Fastening Pattern 6-Nail Fastening Pattern
FastenVng for Slopes Greater Than 21:12
S..N.Itn I.Wni"nlen width
F H-`-
ail w"'
1 12 I 1 12^ 7"
e41s
i•� �2
Four r"Spots of Mph&Roofing Centont
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuard®HP:
r 7• �� �� 4 �O"gia
l�— 7`—� 12�
WSW latww
� Firftnw7hnru&lUsll Bli10
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certiflcate oJAuthorization#9503 6m EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 6 of 8
TRI. x ER
6.3 Hip&Ridge Shingles:
6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard6 HP Hip and Ridge Shingles
and ProEdge Ilip & Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of DuraRidgexa' Hip & Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistance and installation limitations, including the use of hand-sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—BerkshireO Hip&Ridge and High Ridge:
Fig.1 Fig.2
Direction
n Taprlil.5v SiJeYer
trails ` \\'Q Nals1 Nails s
TOP Piece
z! 1
S' ti 1 1 1
1
I- 6—D1 p•• �I
14
6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge:
A
Fi
Fig.C Hip&Ridge Shingle Fastening
. g'
9¢_Pla^alNngvltntl � � TopVkw
Dlrectbn p\
flails Nails-
2"2"
R-P I 1.
A I I i I ��T�-a •
\ 1 1 I
Is „II Y TY V I II
I" Exposure ��
Exposure
la _ ,z"
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-118
Certificate of Authorization 119503 6'EDITION(2017)FBC NON-HVFIZ EVALUATION F1.10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 7 of 8
6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Prevailing Standard
Wind DirectionFastoning
Sco9ant Strip Pattern
27—
6°Exposure ! 1"-I
12° 1 Sealant
YI
Fasten 71' 7 it=' 6°Exposure
Cover Exposed 1 1
_ Fastaners with
Roof Cement
t .
6.3.6 Minimum Nailing—DuraRidge'm Hip&Ridge Shingles:
Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
Pro+aiEFiWird Qirccdm Tip View
a—Diroaianddrnimnta.4.s sc+se Vue en plm
Diracd6ndol rimtDpradcmirunta 11" Vista=u 'Z'
NA
clau
:ti _ n 5a 'osY'rss Coshing Suret-0ail•--- caw,
ti ty I a.
L I I I I «lay
rEg�sss V ILL
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in,order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for,information on which plants produce products covered by Florida Rule 9N-3 CW
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—CLUA9625;(631)546-2458;Kanchi.Agrawala-Dokania@ul.com
- END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS
Certificate of Authorization 119303 6'EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 8 of 8