Loading...
HomeMy WebLinkAboutdoc0722292019012215101955oo Series NUff- 140.17-0630.0.5 NFRC Report 5570 Selrit5 E579 7777 TI7IIIIIIIIIIIII h0ft ►JO. 1`7- OLFAO. 040 Quote # 5543897 PO Number: Job Name: Dennis Ryan www.pgtindustries.com Job Address: Line # Item Description Quantity Location 0001 SH5500 VINYL SINGLE HUNG 5500 Ordered: (1.00) 51.875X49.375X.,STD,5/8" FL,W,EQUAL,7/8 LIG,CL,ES Max, 2.00 2.00 GRID,DBL,SWEEP,1816K-INSTALLED,CMFRT LFT HNDL PUN umber: Certification Type: AAMAA440 Frame Type:.625FLANGE Vent Configuration: EQUAL Window Style: STD Size Selection: CUSTOM Size Ref: ACTUAL Width: 51 7/8 Height: 49 3/8 Actual Size: 51 7/8 X 49 3/8 Rough Masonry: 53 5/8 X 50 3/8 Wood Frame Opening: 52 1/8 X 49 5/8 Egress Opening: 47 5/8 X 20 1/16 (6.6253 SQFT) Frame Color: W -White Balance Type: CONSTANT Glass Family: LI - Laminated Insulating Interlayer Type: PVB090 Glass Makeup: LIA207AA5 Glass: 7/8" LIG (1/8 AN - 7/16 AIR -5/16 AN/AN Does unit need to meet Turtle Code: NO Glass Color: CL -CLEAR 51.7/8" Low E: ENERGY SHIELD MAX Argon Gas: NONE Privacy Glass: NONE - NONE Grid Type: NONE - NO Grid Reinf. Upgrade: NONE - None Screen Type: 1816K - 1816 Charcoal Screen Frame Type: ROLLFORM Vent Latch: N WOCD: N Lock Type: SWEEP - Sweep Latch Upgrade Hardware Finish: N Comfort Lift: Y Lift Rail: N Lock Quantity: 2.0000 Boxing Options: N - None Acc Glass Breakage: N Vent Ht: 24.3305 CAR#: 190-285/1028 PositiveDesignPress ure: 50.0000 Negative Design Pressure: 50.0000 PANumber: FL 1435 EnergyStar: 1.0000 Condensation Resistance: 55.0000 UF: 0.3200 SolarHeatGainCoeff: 0.2200 VT: 0.4800 VTCOG: 0.6300 0002 SH5500 VINYL SINGLE HUNG 5500 Ordered: (2.00) 25.25X37.25X.,STD,5/8" FL,W,EQUAL,7/8 LIG,CL,ES Max,NO 1.00 GRID, DBL,SWEEP,1816K-INSTALLED,CMFRT LFT HNDL Print Date 1/17/2019 Page 1 of 6 Certification Type: AAMAA440 Frame Type:.625FLANGE Vent Configuration: EQUAL Window Style: STD Size Selection: CUSTOM Size Ref: ACTUAL -------= Width: 251/4 Height: 371/4 Actual Size: 25 1/4 X 37 1/4 Rough Masonry: 27 X 38 1/4 Wood Frame Opening: 25 1/2 X 37 1/2 Egress Opening: 21 X 14 (2.0372 SQFT) W Frame Color: W -White Balance Type: CONSTANT ;+ Glass Family: LI - Laminated Insulating Interlayer Type: PVB090 sp Glass Makeup: LIA207AA5 Glass: 7/8" LIG (1/8 AN - 7/16 AIR -5/16 AN/AN Does unit need to meet Turtle Code: NO Glass Color: CL -CLEAR > Low E: ENERGY SHIELD MAX Argon Gas: NONE Privacy Glass: NONE - NONE Grid Type: NONE - NO Grid =�y Reinf. Upgrade: NONE - None Screen Type: 1816K - 1816 Charcoal = 25-114" Screen Frame Type: ROLLFORM Vent Latch: N WOCD: N Lock Type: SWEEP - Sweep Latch Upgrade Hardware Finish: N Comfort Lift: Y Lift Rail: N Lock Quantity: 2.0000 Boxing Options: N - None Acc Glass Breakage: N Vent Ht: 18.2679 CAR#: 190-285/1028 PositiveDesignPressure: 50.0000 NegativeDesignPressure: 50.0000 PANumber: FL 1435 EnergyStar: 1.0000 CondensationResistance: 55.0000 UF: 0.3200 SolarHeatGainCoeff: 0.2200 VT: 0.4800 VTCOG: 0.6300 0003 SH5500 VINYL SINGLE HUNG 5500 Ordered: (3.00) 25.25X49.375X.,STD,5/8" FL,W,EQUAL,7/8 LIG,CL,ES Max,W 1.00 ILYR,NO GRID,DBL,SWEEP,1816K-INSTALLED,CMFRT LFT HNDL Certification Type: AAMAA440 Frame Type:.625FLANGE Vent Configuration: EQUAL Window Style: STD Size Selection: CUSTOM Size Ref: ACTUAL Width: 25 1/4 Height: 49 3/8 Actual Size: 25 1/4 X 49 3/8 Rough Masonry: 27 X 50 3/8 Wood Frame Opening: 25 1/2 X 49 5/8 Egress Opening: 21 X 20 1/16 (2.9214 SQFT) Frame Color: W - White Balance Type: CONSTANT Glass Family: LI - Laminated Insulating Interlayer Type: PVB090 > Glass Makeup: LIA207AA5 Glass: 7/8" LIG (1/8 AN - 7/16 AIR -5/16 AN/AN Does unit need to meet Turtle Code: NO Glass Color: CL -CLEAR Low E: ENERGY SHIELD MAX Argon Gas: NONE Privacy Glass: WH - WHITE Privacy Glass Location: UNIT a Grid Type: NONE - NO Grid Reinf. Upgrade: NONE - None Screen Type: 1816K - 1816 Charcoal Screen Frame Type: ROLLFORM Vent Latch: N WOCD: N - 11Lock Type: SWEEP - Sweep Latch Upgrade Hardware Finish: N Comfort Lift: Y Lift Rail: N Lock Quantity: 2.0000 Boxing Options: N - None Acc Glass Breakage: N Vent Ht: 24.3305 CAR#: 190-285/1028 PositiveDesignPressure: 50.0000 NegativeDesignPressure: 50.0000 PANumber: FL 1435 EnergyStar: 1.0000 Condensation Resistance: 55.0000 UF: 0.3200 SolarHeatGainCoeff: 0.2200 VT: 0.4800 VTCOG: 0.6300 0004 SH5500 VINYL SINGLE HUNG 5500 Ordered: (4.00) 35.75X49.375X.,STD,5/8" FL,W,EQUAL,7/8 LIG,CL,ES Max,NO 1.00 GRID, DBL,SWEEP,1816K-INSTALLED,CMFRT LFT HNDL Print Date 1/17/2019 Page 2 of 6 Certification Type: AAMAA440 Frame Type:.625FLANGE Vent Configuration: EQUAL Window Style: STD r Size Selection: CUSTOM Size Ref: ACTUAL Width: 35 3/4 Height: 49 3/8 Actual Size: 35 3/4 X 49 3/8 Rough Masonry: 37 1/2 X 50 3/8 Wood Frame Opening: 36 X 49 5/8 Egress Opening: 31 1/2 X 20 1/16 (4.3821 SQFT) Frame Color: W - White Balance Type: CONSTANT o ------:; , Glass Family: LI - Laminated Insulating Interlayer Type: PVB090 Glass Makeup: LIA207AA5 Glass: 7/8" LIG (1/8 AN - 7/16 AIR -5/16 AN/AN Does unit need to meet Turtle Code: NO Glass Color: CL -CLEAR - = Low E: ENERGY SHIELD MAX Argon Gas: NONE Privacy Glass: NONE - NONE Grid Type: NONE - NO Grid Reinf. Upgrade: NONE - None Screen Type: 1816K - 1816 Charcoal r 35-X4" Screen Frame Type: ROLLFORM Vent Latch: N WOCD: N Lock Type: SWEEP - Sweep Latch Upgrade Hardware Finish: N Comfort Lift: Y Lift Rail: N Lock Quantity: 2.0000 Boxing Options: N -None Acc Glass Breakage: N Vent Ht: 24.3305 CAR#: 190-285/1028 PositiveDesignPressure: 50.0000 NegativeDesignPressure: 50.0000 PANumber: FL 1435 EnergyStar: 1.0000 Condensation Resistance: 55.0000 UF: 0.3200 SolarHeatGainCoeff: 0.2200 VT: 0.4800 VTCOG: 0.6300 0005 SH5500 VINYL SINGLE HUNG 5500 Ordered: (5.00) 38.5X24.75X.,STD,5/8" FL,W,EQUAL,7/8 LIG,CL,ES Max,W 1.00 ILYR,NO GRID,DBL,SWEEP,1816K-INSTALLED,CMFRT LFT HNDL Certification Type: AAMAA440 Frame Type:.625FLANGE Vent Configuration: EQUAL Window Style: STD ` Size Selection: CUSTOM Size Ref: ACTUAL Width: 38 1/2 Height: 24 3/4 Actual Size: 38 1/2 X 24 3/4 Rough Masonry: 40 1/4 X 25 3/4 +' Wood Frame Opening: 38 3/4 X 25 Egress Opening: 34 1/4 X 7 3/4 (1.8361 SQFT) --- - - 1 Frame Color: W - White Balance Type: CONSTANT as-vz^ 1 Glass Family: LI - Laminated Insulating Interlayer Type: PVB090 Glass Makeup: LIA207AA5 Glass: 7/8" LIG (1/8 AN - 7/16 AIR -5/16 AN/AN Does unit need to meet Turtle Code: NO Glass Color: CL -CLEAR Low E: ENERGY SHIELD MAX Argon Gas: NONE Privacy Glass: WH - WHITE Privacy Glass Location: UNIT Grid Type: NONE - NO Grid Reinf. Upgrade: NONE - None Screen Type: 1816K - 1816 Charcoal Screen Frame Type: ROLLFORM Vent Latch: N WOCD: N Lock Type: SWEEP - Sweep Latch Upgrade Hardware Finish: N Comfort Lift: Y Lift Rail: N Lock Quantity: 2.0000 Boxing Options: N -None Acc Glass Breakage: N Vent Ht: 12.0179 CAR#: 190-285/1028 Positive Design Pressure: 50.0000 NegativeDesignPressure: 50.0000 PANumber: FL 1435 EnergyStar: 1.0000 CondensationResistance: 55.0000 UF: 0.3200 SolarHeatGainCoeff: 0.2200 VT: 0.4800 VTCOG: 0.6300 0006 SH5500 VINYL SINGLE HUNG 5500 Ordered: (6.00) 35.75X37.375X.,STD,5/8" FL,W,EQUAL,7/8 LIG,CL,ES Max,NO 1.00 GRID,DBL,SWEEP,1816K-INSTALLED,CMFRT LFT HNDL Print Date 1/17/2019 Page 3 of 6 Certification Type: AAMAA440 Vent Configuration: EQUAL Size Selection: CUSTOM Width: 35 3/4 Actual Size: 35 3/4 X 37 3/8 Wood Frame Opening: 36 X 37 5/8 Frame Color: W - White Glass Family: LI - Laminated Insulating Glass Makeup: LIA207AA5 Does unit need to meet Turtle Code: NO Low E: ENERGY SHIELD MAX Privacy Glass: NONE - NONE Reinf. Upgrade: NONE - None Screen Frame Type: ROLLFORM WOCD: N Upgrade Hardware Finish: N Lift Rail: N Boxing Options: N -None Vent Ht: 18.3304 Positive Design Press u re: 50.0000 PANumber: FL 1435 Co ndensatio n Resistan ce: 55.0000 SolarHeatGainCoeff: 0.2200 VTCOG: 0.6300 0007 SH5500 VINYL SINGLE HUNG 5500 (7.00) 25.5X25.X.,STD,5/8" FL,W,EQUAL,7/8 LIG,CL,ES Max,NO GRID, DBL,SWEEP,1816K-INSTALLED,CMFRT LFT HNDL 0008 SH5500 VINYL SINGLE HUNG 5500 (8.00) 42.5X37.X.,STD,5/8" FL,W,EQUAL,7/8 LIG,CL,ES Max,NO GRID,DBL,SWEEP,1816K-INSTALLED,CMFRT LFT HNDL Ordered: 1.00 Ordered: 1.00 Frame Type:.625FLANGE Window Style: STD Size Ref: ACTUAL Height: 37 3/8 Rough Masonry: 37 1/2 X 38 3/8 Egress Opening: 31 1/2 X 14 1/16 (3.0696 SQFT) Balance Type: CONSTANT Interlayer Type: PVB090 Glass: 7/8" LIG (1/8 AN - 7/16 AIR -5/16 AN/AN Glass Color: CL -CLEAR Argon Gas: NONE Grid Type: NONE - NO Grid Screen Type: 1816K - 1816 Charcoal Vent Latch: N Lock Type: SWEEP - Sweep Latch Comfort Lift: Y Lock Quantity: 2.0000 Acc Glass Breakage: N CAR#: 190-285/1028 NegativeDesignPressure: 50.0000 EnergyStar: 1.0000 UF: 0.3200 VT: 0.4800 Frame Type:.625FLANGE Window Style: STD Size Ref: ACTUAL Height: 25.0000 Rough Masonry: 27 1/4 X 26 Egress Opening: 21 1/4 X 7 7/8 (1.1576 SQFT) Balance Type: CONSTANT Interlayer Type: PVB090 Glass: 7/8" LIG (1/8 AN - 7/16 AIR -5/16 AN/AN Glass Color: CL -CLEAR Argon Gas: NONE Grid Type: NONE - NO Grid Screen Type: 1816K - 1816 Charcoal Vent Latch: N Lock Type: SWEEP - Sweep Latch Comfort Lift: Y Lock Quantity: 2.0000 Acc Glass Breakage: N CAR#: 190-285/1028 N eg ative Design Pressure: 50.0000 EnergyStar: 1.0000 UF: 0.3200 VT: 0.4800 Print Date 1/17/2019 Page 4 of 6 Certification Type: AAMAA440 Vent Configuration: EQUAL Size Selection: CUSTOM -' Width: 251/2 Actual Size: 25 1/2 X 25 Wood Frame Opening: 25 3/4 X 25 1/4 ro Nom' Frame Color: W -White Glass Family: LI - Laminated Insulating _T1 1 Glass Makeup: LIA207AA5 -_ r- 25-1/2" Does unit need to meet Turtle Code: NO Low E: ENERGY SHIELD MAX Privacy Glass: NONE -NONE Reinf. Upgrade: NONE - None Screen Frame Type: ROLLFORM WOCD: N Upgrade Hardware Finish: N Lift Rail: N Boxing Options: N - None Vent Ht: 12.1429 Positive Design Pressure: 50.0000 PANumber: FL 1435 Condensation Resistance: 55.0000 SolarHeatGainCoeff: 0.2200 VTCOG: 0.6300 0008 SH5500 VINYL SINGLE HUNG 5500 (8.00) 42.5X37.X.,STD,5/8" FL,W,EQUAL,7/8 LIG,CL,ES Max,NO GRID,DBL,SWEEP,1816K-INSTALLED,CMFRT LFT HNDL Ordered: 1.00 Ordered: 1.00 Frame Type:.625FLANGE Window Style: STD Size Ref: ACTUAL Height: 37 3/8 Rough Masonry: 37 1/2 X 38 3/8 Egress Opening: 31 1/2 X 14 1/16 (3.0696 SQFT) Balance Type: CONSTANT Interlayer Type: PVB090 Glass: 7/8" LIG (1/8 AN - 7/16 AIR -5/16 AN/AN Glass Color: CL -CLEAR Argon Gas: NONE Grid Type: NONE - NO Grid Screen Type: 1816K - 1816 Charcoal Vent Latch: N Lock Type: SWEEP - Sweep Latch Comfort Lift: Y Lock Quantity: 2.0000 Acc Glass Breakage: N CAR#: 190-285/1028 NegativeDesignPressure: 50.0000 EnergyStar: 1.0000 UF: 0.3200 VT: 0.4800 Frame Type:.625FLANGE Window Style: STD Size Ref: ACTUAL Height: 25.0000 Rough Masonry: 27 1/4 X 26 Egress Opening: 21 1/4 X 7 7/8 (1.1576 SQFT) Balance Type: CONSTANT Interlayer Type: PVB090 Glass: 7/8" LIG (1/8 AN - 7/16 AIR -5/16 AN/AN Glass Color: CL -CLEAR Argon Gas: NONE Grid Type: NONE - NO Grid Screen Type: 1816K - 1816 Charcoal Vent Latch: N Lock Type: SWEEP - Sweep Latch Comfort Lift: Y Lock Quantity: 2.0000 Acc Glass Breakage: N CAR#: 190-285/1028 N eg ative Design Pressure: 50.0000 EnergyStar: 1.0000 UF: 0.3200 VT: 0.4800 Print Date 1/17/2019 Page 4 of 6 Certification Type: AAMAA440 Frame Type:.625FLANGE Vent Configuration: EQUAL Window Style: STD Size Selection: CUSTOM Size Ref: ACTUAL Width: 42 1/2 Height: 37.0000 Actual Size: 42 1/2 X 37 Rough Masonry: 44 1/4 X 38 – Wood Frame Opening: 42 3/4 X 37 1/4 Egress Opening: 38 1/4 X 13 7/8 (3.6775 SQFT) ji Frame Color: W -White Balance Type: CONSTANT Glass Family: LI - Laminated Insulating Interlayer Type: PVB090 Glass Makeup: LIA207AA5 Glass: 7/8" LIG (1/8 AN - 7/16 AIR -5/16 AN/AN k e:=err— Does unit need to meet Turtle Code: NO Glass Color: CL -CLEAR Low E: ENERGY SHIELD MAX Argon Gas: NONE Privacy Glass: NONE - NONE Grid Type: NONE - NO Grid Reinf. Upgrade: NONE - None Screen Type: 1816K - 1816 Charcoal Screen Frame Type: ROLLFORM Vent Latch: N WOCD: N Lock Type: SWEEP - Sweep Latch Upgrade Hardware Finish: N Comfort Lift: Y Lift Rail: N Lock Quantity: 2.0000 Boxing Options: N -None Ace Glass Breakage: N Vent Ht: 18.1429 CAR#: 190-285/1028 PositiveDesignPressure: 50.0000 NegativeDesignPressure: 50.0000 PANumber: FL 1435 EnergyStar: 1.0000 Conde nsationResistance: 55.0000 UF: 0.3200 SolarHeatGainCoeff: 0.2200 VT: 0.4800 VTCOG: 0.6300 0009 SGD770 SLIDING GLASS DOOR 770 Ordered: (9.00) 104.X79.75,BYPASS,3P3T,OXX,REV,2.5,NARROW,W,1 1.00 TLIG,CLEAR,ARG,ES Max,NO GRID,ALL Send Unit: COMPLETE Certification Type: MIAMI —- NOA Selection: 17-0420.12 Door Configuration: BYPASS PnIfTrk: 3 Panel / 3 Track Panel Configuration: OXX j Panel Stack: REV Size Selection: CUSTOM IC Width: 104.0000 Height: 79.7500 Actual Size: 104 X 79 3/4 Calc Track Length: 104.0000 Frame Color: W -White Glass Makeup: LIT306SS7 j --- ! Glass: 1" LIG (3/16 Tmp - 3/8 ARG - 7/16 HS/HS Glass Family: LI - Laminated Insulating • Does unit need to meet Turtle Code: NO Glass Color: CL -CLEAR Low E: ENERGY SHIELD MAX Argon Gas: ARGON Privacy Glass: NONE - NONE Interlayer Type: PVB090 Grid Type: NONE - NO Grid Add HD Stile for DP Upgrade: N Stile: STD/STD Sill Riser Height: 2.5000 Sill Riser Type: NARROW Screen Panel Type: NONE Send Screen Frame with Unit: N Handle Type: RAISED/RAISED Handle Color: W -White Lock/Handle Location: STD Secondary Lock Type: NONE Key Lock: N Keyed Alike: N Panel Opr Rlr: STSTEELTM Stainless Steel Tandem Panel Fxd Rlr: STSTEELTM Stainless Steel Tandem Anchor Group: C.SGD770 Boxing Options: N - None CAR#: 17-0420.12 PositiveDesignPressure: 46.7000 NegativeDesignPressure: 60.0000 PANumber: FL -251 EnergyStar: NONE CondensationResistance: 17.0000 UF: 0.6500 SolarHeatGainCoeff: 0.2200 VT: 0.4400 VTCOG: 0.6200 0010 SGD770 SLIDING GLASS DOOR 770 Ordered: (10.00) 69.5X79.75,BYPASS,2P2T,X0,STD,2.5,NARROW,W,1 1.00 TLIG,CLEAR,ARG,ES Max,NO GRID,ALL Print Date 1/17/2019 Page 5 of 6 Send Unit: COMPLETE NOA Selection: 17-0420.12 Pnl/Trk: 2 Panel / 2 Track Panel Stack: STD Width: 69.5000 Actual Size: 69 1/2 X 79 3/4 Frame Color: W - White Glass: 1" LIG (3/16 Tmp - 3/8 ARG - 7/16 HS/HS Does unit need to meet Turtle Code: NO Low E: ENERGY SHIELD MAX Privacy Glass: NONE - NONE Grid Type: NONE - NO Grid Add HD Stile for DP Upgrade: N Sill Riser Height: 2.5000 Screen Panel Type: NONE Screen Rail Integrated: N Handle Color: W - White Secondary Lock Type: NONE Keyed Alike: N Panel Fxd Rlr: STSTEELTM Stainless Steel Tandem Boxing Options: N - None Positive Des ignPressure: 46.7000 PANumber: FL -251 CondensationResistance: 17.0000 SolarHeatGainCoeff: 0.2200 VTCOG: 0.6200 Certification Type: MIAMI Door Configuration: BYPASS Panel Configuration: XO Size Selection: CUSTOM Height: 79.7500 Calc Track Length: 69.5000 Glass Makeup: LIT306SS7 Glass Family: LI - Laminated Insulating Glass Color: CL - CLEAR Argon Gas: ARGON Interlayer Type: PVB090 Add Panel Reinf: N Stile: STD/STD Sill Riser Type: NARROW Send Screen Frame with Unit: N Handle Type: RAISED/RAISED Lock/Handle Location: STD Key Lock: N Panel Opr Rlr: STSTEELTM Stainless Steel Tandem Anchor Group: C.SGD770 CAR* 17-0420.12 Negative Design Pressure: 60.0000 EnergyStar: NONE UF: 0.6500 VT: 0.4400 Print Date 1/17/2019 Page 6 of 6