Property Information Building Information ,
Owner: ROB&ERICA SCHAAL Wind Zone: 170 MPH.
Address: 7913 PLANTATION LAKES Exposure Category: C
PORT ST LUCIE,FL 34986 Minimum Building Dimension: 25 ft.
Mean Roof Height: 15 ft. 1
Risk Category: II
I
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 72.75 61.75 7 35.0 -38.2
2 Int 72.75 61.75 7 35.0 -38.2
3 Int 72.75 61.75 7 35.0 -38.2
4 - Int 72.75 61.75 7 35.0 -38.2
5 Int 35.75 61.75 7 36.7 -39.9
6 Int 72.75 61.75 7 35.0 -38.2
7 Int 35.75 36.25 7 37.8 -41.0
• 8 Int 35.75 61.75 7 36.7 -39.9
9 hit 25.50 _ 49.50 7 37.8 -41.0
'a
t .
0
"Zzlo
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.