Loading...
HomeMy WebLinkAboutBuilding Permit ApplicationALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: /"'�/ Permit Number: Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential x PERMIT APPLICATION FOR: Roof PROPOSED IMPROVEMENT LOCATION: Address: 3200 South 7th Street Fort Pierce, FI. 34982 Lot 64 Legal Description: Maravilla Gardens S/D-Unit Three Property Tax ID #: 2427-602-0060-000-0 Lot No. Site Plan Name: Block No. Project Name: Kathy Dourney Setbacks Front Back: Right Side: _ Left Side: DETAILED DESCRIPTION OF WORK: Tear off existing shingle roof. Renail sheathing to code. Install Tribult Sand SA underlayment FL16048-R-6 Install OC Tru Def. Shingles FL10674-R13 CONSTRUCTION INFORMATION: Additional work to b rformed under this permit –check all that appy: HVAC Gas Tank E]Gas Piping _ Shutters L Windows/Doors Electric I—! Plumbing Sprinklers Generator Roof Roof pitch Total Sq. Ft of Construction: S. of First Floor: Cost of Construction: $ 5200 Utilities:n Sewer E]Septic Building Height: OWNER/LESSEE: CONTRACTOR: Name Kathy Dourney Name: Christopher A. Long Address: 3200 S. 7th St. Lot 64 Company: The Roof Authority, Inc. City: Fort Pierce State: FIL Address: 6771 N. Old Dixie Hwy Zip Code: 34982 Fax: City: Fort Pierce State: FL Phone No. 772-203-3256 Zip Code: 34946 Fax: 772-468-2247 E -Mail: Phone No. 772-468-7870 Fill in fee simple Title Holder on next page ( if different E -Mail: tral993@gmail.com from the Owner listed above) State or County License: CCC056933 If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: Not Applicable Name:_ Address: City: Zip: Phone State FEE SIMPLE TITLE HOLDER: Not Applicable Name:_ Address: City: Zip: Phone: MORTGAGE COMPANY: Name: Address: City: Zip: Phone:_ BONDING COMPANY: Name: Address: City: Zip: Phone: Not Applicable State: Not Applicable OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before commencing work or recordiniz Vour Notice of Commencement. _ I LAW" � o Sign ture & Owner/ Lessee/CoUtractor as Agent for Owner Signature o Contrac r/License Holder STATE OF FLORIDA // STATE OF FLORIDA COUNTY OF COUNTYOF tlGl� The forgoing instrument was acknowledged before me this day of_ 20 (? by Namb of person making statement Personally Known OR Produced Identification_ Type of identification Produced ,) / -L�) d . The far Ding instrument was acknowledged before me this day of „�.� 20� by C it �_t Name of person making statement' Personally Known OR Produced Identification Type of Identification Produced CJ rue- "f1..Sw`ia (Signature of Notary Public- State of Florida) II (Signatur of Notary Public- State of Florida ) Commission No. C � ISS REVIEWS FRONT ZONING COUNTER REVIEW DATE RECEIVED DATE COMPLETED Rev. 8/2/17 I11imothy W. Sutton OTARY PUBLIC Commission No. STATE OF FLORID 4 r'r,mm# GG 185982 Timoth utton NOTA � LIC STATE OF FLORIDA )fres wzuV Ex'res 3/ 20/2022 UPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE REVIEW REVIEW REVIEW REVIEW REVIEW Drawing Report Dourney Kathy 3200 S 7th Lot 64 Ft Pierce - Multi System Template 2016 Section: Reroof 30 Year Dimensionals Page: SA/ 30 Year Dimensional "Lifetime" shingles Eagleview 1/22/2019 6771 N. Old Dixie Highway Fort Pierce, FL 34946 Phone: (772) 468-7870 Fax: (772) 468-2247 Drawing Report Dourney Kathy 3200 S 7th Lot 64 Ft Pierce - Multi System Template 2016 Section: Reroof 30 Year Dimensionals Page: SA/ 30 Year Dimensional "Lifetime" shingles Eagleview Legend Pitch Description SF LF EA Shingle Field 795.00 136.00 6.00 Measurable General Conditions 795.00 136.00 6.00 Shingle Tear Off 795.00 136.00 6.00 Eave 106.00 2.00 Gable 30.00 2.00 Ridge 53.00 1.00 40 2" Lead Stack Flashing 2.00 • 8" J Vent Flashing 1.00 0 12" J Vent Flashing 3.00 0 14" J Vent Flashing 1.00 1/22/2019 Page 2 6771 N. Old Dixie Highway Fort Pierce, FL 34946 Phone: (772) 468-7870 Fax: (772) 468-2247 TRINITY ERD EVALUATION REPORT TRI -BUILT Materials Group, LLC PO Box 70 Rutherford, NJ 07070 (800)516-1485 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 (203)262-9245 Evaluation Report A42960.30.12 -R6 FL16048-R6 Date of Issuance: 10/25/2012 Revision 6: 09/25/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: TRI -BUILT Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCAANE1983 at0 .34 T?7� a _ r,.,��,a,-,��, roti;•; "IL .. The facsimile seal appearing was authorized by Robert Nieminen, PE on 09/25/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinity lERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: TRI -BUILT Roof Underlayments, as produced by TRI -BUILT Materials Group, LLC, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Resistance FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1504.6 Accelerated Weathering ASTM G155 2005 1507.2.4 / 1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 (04-12) 2012 3. REFERENCES: Entity Examination Reference Date ERD (TST6049) Physical Properties 540540.02.13-1 02/19/2013 ERD (TST6049) Physical Properties S40540.11.13 11/19/2013 ERD (TST6049) Physical Properties 540540.03.14 03/26/2014 ERD (TST6049) Physical Properties 544870,04.14-2 04/02/2014 ERD (TST6049) Physical Properties 544870.04.14-3 04/02/2014 ERD (TST6049) Physical Properties 544870.04.14-1 04/10/2014 ERD (TST6049) Physical Properties 544870.04.14-4 04/10/2014 ERD (TST6049) Physical Properties 543530.02.14-1-R1 05/14/2014 ERD (TST6049) Physical Properties 543530.05.14 05/28/2014 ERD (TST6049) Physical Properties 540540.10.14 10/31/2014 ERD (TST6049) Physical Properties SC7645.02.15 02/13/2015 ERD (TST6049) Accelerated Weathering SC8520.04.15 05/27/2015 ERD (TST6049) Wind Resistance SC14045.05.17-R1 06/07/2017 UL, LLC. (QUA9625) Quality Control Multiple -Listing R16814 12/10/2015 UL, LLC, (QUA9625) Quality Control Service Confirmation Exp. 07/18/2020 4. PRODUCT DESCRIPTION: 4.1 Tri -Built Sand -R SA Shingle Underlayment is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment, with a 36 -inch sheet width; meets ASTM D1970. 4.2 Tri -Built S/A HT TU Underlayment is a self -adhering, non -woven polyester fabric surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012. 4.3 Tri -Built Smooth HT S/A Underlayment is a self -adhering, glass -mat reinforced, film -surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, I.I.C. Evaluation Report A42960.10.12 -R6 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6 TRI -BUILT Roof Underlayments; (800) 516-1485 Revision 6:09/25/2017 Page 2 of 6 TRINITY ERD 5.4 TRI -BUILT Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS Underlayment Asphalt Nail -On Tile Foam -On Tile Metal Wood Shakes Slate Shingles & Shingles No No No Yes Yes Tri -Built Sand -R SA Shingle Yes Underlayment Yes Tri -Built S/A HT TU Underlayment Yes Yes See 5.5.1 Yes Yes Yes Yes Tri -Built Smooth HT S/A Yes Underlayment No No Yes Yes 5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations. TABLE 1A: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS) Adhesive Florida Product Approval Underlayments ICP Adhesives Polyset® AH -160 FL6332 Tri -Built S/A HT TU Underlayment Dow TileBond'" FL22525 Tri -Built S/A HT TU Underlayment 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Tri -Built Sand -R SA Shingle Underlayment, Tri -Built S/A HT TU Underlayment or Tri -Built Smooth HT S/A Underlayment applied to: ➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete. While not required over plywood, OSB or Southern Yellow Pine substrates, TRI -BUILT Materials Group, LLC recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note: TRI -BUILT Materials Group, LLC requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self -adhering underlayment. 5.6.2 Bond -to -Insulation: Tri -Built Sand -R SA Shingle Underlayment, Tri -Built S/A HT TU Underlayment or Tri -Built Smooth HT S/A Underlayment applied to: ➢ Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems (Tri -Built S/A HT TU Underlayment only), insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474, Appendix D or TAS 114, Appendix J. ' Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. Exterior Research and Design, LLC. Evaluation Report A42960.10.12 -R6 Certificate of Authorization 119503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6 TRI -BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017 Page 3 of 6 I TRINrry ERD 5.6.3 Bond to Mechanically Attached Base Laver: Tri -Built Sand -R SA Shingle Underlayment, Tri -Built S/A HT TU Underlayment or Tri -Built Smooth HT S/A Underlayment applied to: ➢ ASTM D226, Type I or II felt. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems (Tri -Built S/A HT TU Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04- 12). 5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to direct -deck underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind pressures. #1 Maxi mu_m_De_sign Pressure = -45.0 psf: Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 or RESISTO EXTERIOR PRIMER Underlayment: Tri -Built S/A HT TU Underlayment, self -adhered. #2 Maximum Design Pressure = -67.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Soprema Elastocol 600c Underlayment: Tri -Built S/A HT TU Underlayment, self -adhered. #3 Maximum Design Pressure = -150.0 nsf: Deck: Min. 15/32 -inch APA -rated BCX plywood (may be installed C -side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion, All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional) RESISTO EXTERIOR PRIMER Underlayment: Tri -Built S/A HT TU Underlayment, self -adhered, shall be thoroughly roll using hand roller and/or weighted roller to ensure there are no voids, and ensure there are no voids/bridging at side and end -laps. #4 Maximum Desien Pressure = -60.0 Dsf: Deck: Min. 19/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6 -inch o.c. at the 4 -inch laps and 6 -inch o.c. in three, equally spaced rows in the center of the sheet. Underlayment: Tri -Built S/A HT TU Underlayment, self -adhered. Exterior Research and Design, I.I.C. Evaluation Report A42960.10.12 -R6 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-116 TRI -BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017 Page 4 of 6 I TRINITY! ERD 5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: Tri -Built Sand -R SA Shingle Underlayment or Tri -Built Smooth HT S/A Underlayment shall not be left exposed for longer than 30 -days after installation Tri -Built S/A HT TU Underlayment shall not be left exposed for longer than 180 -days after installation. 5.8 Tile Slippage Limitations (TAS 103 per FR5A/TRI April 2012 (04-12)1: When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Flat Max. 10 -tile stack 6:12 Lugged Max. 10 -tile stack 5:12 Max. 10 -tile stack (bottom 2 -tile stack shall be inverted, followed by 8 tiles high 6:12 on slope, as shown below) ._ { 4 t Tri -Built 5/A HT TU Underlayment Lugged Exterior Research and Design, I.I.C. Evaluation Report A42960.10.12 -R6 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6 TRI -BUILT Roof Underlayments; (800) 516-1485 Revision 6:09/25/2017 Page 5 of 6 TRINITY ERD 6. INSTALLATION: 6.1 TRI -BUILT Roof Underlayments shall be installed in accordance with TRI -BUILT Materials Group, LLC published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Tri -Built Sand -R SA Shingle Underlayment, Tri -Built S HT TU Underlayment or Tri -Built Smooth HTMA Underlayment: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.3.2 Non -Tile applications: While priming is optional, TRI -BUILT Materials Group, LLC recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel -off the release film diagonally while holding the membrane tight. Firmly roll, broom or hand -press the membrane into place to achieve a bond. Horizontal seams should be minimum 3 -inches, configured to shed water. Vertical seams should be 6 - inches and staggered not less than 2 -ft from vertical seams in the course below, sealed in accordance with TRI -BUILT Materials Group, LLC requirements. When installing at slopes above 8:12, TRI -BUILT Materials Group, LLC recommends back -nailing in the overlap area at the top of the sheet at 12 -inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys, apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications Tri -Built S A HT TU Underlayment and : Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam -on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012 (04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See Table 2 herein, and TRI -BUILT Materials Group, LLC published requirements for tile staging. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Gulfport, MS 9. QUALITY ASSURANCE ENTITY: UL, LLC —QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT - Exterior Research and Design, I.I.C. Evaluation Report A42960.10.12 -R6 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6 TRI -BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017 Page 6 of 6 1/2/2018 Florida Building Code Online In Business . Professional ( 1 e SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats 9 Facts Publications FBC Staff SCIS Site Map Links Search dor p PApproval USER:ER: Public User Product Approval Menu > VLpduCt or Application $gan;h > Appllcatlon List > Application Detail FL # FL10674-R13 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740) 404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo, OH 43659 (419)376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert I.M. Nleminen Evaluation Report Florida License PE -59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 05/16/2020 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code PLID674 R13 CO] 2017 01 COI Nlemingn.pof Standard ASTM D3161 ASTM D3462 ASTM D7158 Year 2016 2010 2011 Ilttp://www.floridabuilding.org/pdpr_app_dtl.aspx?param=wGEVXC1wt0gtBNhEYSV%2boQT%2b6w7ahRegIC08U aR6ixESFl1s7lvJgZew%3d%aid 112 1/2/2018 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved of Products Florida Building Code Online Model, Number or Name Method 1 Option D 10/10/2017 10/11/2017 10/15/2017 12/12/2017 10674.1I Owens Corning Asphalt Roofing Shingles and Starters Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Refer to ER, Section 5, Description 3 -tab, 4 -tab, 5 -tab, laminated, starter and hip & ridge shingles Installation Instructions ��iQ,�,�4 R�II �D12.10 FLNAL ER OC ASPHALT SHiNGLCS FL10674-R13 odf Verified By: Robert ], M, Nleminen PE - 59166 Created by Independent Third Party: Yes Evaluation Reports FL10674 R13 AE 2017 10 FINAL ER OC ASPHALT Created by Independent Third Party: Yes Contact Us :: 280] Blair %qne Road. Tallaltassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Cooyrlaht 2007.2011 Statc of Flnrlda.:: Privacy Statement :: Accessibglty_ Statcmen�gt :: Refund Statement Under Florlda law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: FoiM P* _J Credit Card Safe htip://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgtBNbEY5V`/o2boQT%2b6w7ahRegICQ8ucR6!xEBFhs7tvJgZewa/o3d%3d 2/2 TTP,�'INITYIERD EVALUATION REPORT Owens Corning One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization 119503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 (203) 262-9245 Evaluation Report 037940.02.12-R8 FL10674-R13 Date of Issuance: 02/06/2012 Revision 8: 10/09/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 �6�IStlr lig, :a 01 The facsimile seal appearing was authorized b Robert °���f'JU�kt 5,a•. PP g Y Nieminen, P E on 10/09/2017 This does not serve as an electronically signed document CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. V TRINITY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Entity Examination Reference Date UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 UL LLC (TST9628) Physical Properties Classification letter 10/02/2015 Miami -Dade (CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation Exp. 05/16/2020 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic' and Supreme' are fiberglass reinforced, 3 -tab asphalt roof shingles. 4.1.2 Berkshire' are fiberglass reinforced, 4 -tab asphalt roof shingles. 4.1.3 DevonshireTm are fiberglass reinforced, 5 -tab asphalt roof shingles. 4.1.4 Duration', TruDefinition' Duration', Duration' Premium Cool, TruDefinition' Duration' Designer Color Collection, TruDefinition' Oakridge', Oakridge' and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Hip & Ridge Shingles: 4.2.1 Berkshire' Hip & Ridge Shingles, High Ridge, WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidge'" Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Accessory Starter Strips: 4.3.1 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, U.C. Evaluation Report 037940.02.12-R8 certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017 Page 2 of 8 TRINITY ERD 5.4 Wind Classification: 5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd = 150 mph (Vnit = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasd = 150 mph (Vtit = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations, 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 611320-3, per FBC 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Asphalt Shingles; 6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Berkshire' shingles require minimum five (5) nails per shingle. ➢ WeatherGuarde HP shingles require minimum six (6) nails per shingle. ➢ Devonshire'" shingles require minimum six (6) nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing — Starter Strip Shingle and Starter Strip Plus: Felt underlayment Deck Self -adhered Weatherlocka atrderlaymenl Daipe Dreg edge g 4 Nails located 2"-3" from save Install first Self-sealing ndhesive StarlerStripp _ positioned atong eave shingle with 6" removed Starter Strip shingle overhangs eaves and rakes'/ Fekunder4ymem Deck Selkdhered WeatherLock® undedayment Drip edge Grip — edge NsIR fouled -- 2'-3" hum eave Arst Starter Strip Pkts SffiInoal posidoaling adhesive Posidonsd akag leve vdlh V removed �—�- Starter Strip Plus overhangs eaves and rakes 1/4"-3/4" Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R8 Certificate of Authorization #9503 6" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017 Page 3 of 8 6.2.6 Minimum Nailing — Classic® & Supreme: Normal Mansard or Area pars Wind Areas High Wind desysnes y Aare pare vlenfos norraalaa Areas vientoe fuartes IAs F1 EA 6"Exposure Exposioidn 6.2.7 Minimum Nailing — Berkshire®: Standard Fastening Pattern VtR-INITY ERD Normal Mansard or Area pars Wind Areas High Wind deavanes y Area para vientos normalas Areas vienros fuarres 8 618" Exposure ExpOW06n Sealant strip La lira de sellador •�� •- a 0-0 4! 8 Vi" 8 W. 8 rh" 8 Ik" r r 6 -Nail Fastening Pattern Sealant strip Le flea de sollador �.t--► 04 ---------- 0� e e 84 ---------- P- • t,. J a a t7t- 2" W Asphalt roofingoament Cemenlo do Who do asfalto Mansard or Steep Slope Fastening Pattern Exterior Research and Design, U.C. Evaluation Report 037940.02.12-R8 Certificate ojAuthorization 119503 6'" EDITION (2017) FBC NON-HVH2 EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017 Page 4 of 8 6.2.8 Minimum Nailing — Devonshire*^": I.J 711 811 8" 811 7" - clavas 5.518" exposure Sealant location Exposlel6n de 5.518 pull; Ubicad6n del sellador Standard 6 -Nail Fastening Pattern �l TRINITY ERD Nails - r r 6Y Ten 1" Spots of ASDhalt Roof Cement Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing — Duration®, TruDefinition° Duration, Duration® Premium Cool & TruDefinition® Duration® Designer Color Collection: 4 -Nell Fastening Pattern SrreNAlw PaaSanlnQ area YndIT Nail, Typical mow:"��i • a � ��—:ti.ni_.—_ �Is��i. 5.17x" e..pra" Standard Fastening Pattern 6 -Nall Fastening Pattern S■nNalla? Isomk9 e,r■ vAdlh Nall, Typical ll 12" 5.vB.•; .0-af 6 -Nail Fastening Pattern Fastening for Slopes Greater Than 21:12 SuraNeaA iaaWMil arae wldth 1T7ypiael 1` 12" 12^ 4 T' e.1re^ s•ve^ Four t- span ofAsphap Rnannp dmanP Mansard or Steep Slope Fastening Pattern Exterior Research and Design, U.C. Evaluation Report 037940.02.12-R8 Certificate of Authorization 1!9503 6" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017 Page 5 of 8 \J'TRINITY RINITY ERD 6.2.1 Minimum Nailing—TruDefinition Oakridge®, Oakridge®: 4 Nail Pattern Esquema con 4 clavos r r Is — 12" 5 618" Exposure Mails 6 518" Exposure Exposfcl6ndo66/9pulg, clavos Exposicl6ndo6618pulg. Standard Fastening Pattern 6 Nall Pattern Esquema con 6 clavos t• r F [4— 12" Mails 6 618" Exposure clavos 5 618" Exposure Exposfei6n de 6 618pulg. Exposld6n de 6 6/8 paig. Fastening for Slopes Greater Than 21:12 -_ "N+INDWOningm.—Idth NMI, ryplcM 1^I 7i" � f 17" e•+N" s.ya" ►out 1"ep"I. "r A•phee Ilbtlllnp C.- Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing — WeatherGuard° HP: 6 -Nail Fastening Pattern Single Ode View Pleb 1nEelrnl MrMenrtr7lrw� Ndl 1i�� C'L� en •rilar i }lFdf� Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R8 Certificate of Authorization #9503 6" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017 Page 6 of 8 '( TRINITY I ERD 6.3 Hip 1311 Ridge Shingles: 6.3.1 Installation of Berkshire® Hip and Ridge Shingles, High Ridge, WeatherGuard® HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using four (4) nails per shingle. Installation of DuraRidge'" Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand -sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing — Berkshire® Hip & Ridge and High Ridge: Fig. 1 �— PravAIIng Aina Dlredlon Nal a f � � A I I q I A I E111wauro Fig. 2 TopMew slNevlew Napa {k411s 1' � TopLMnlr651atl 4" Piece r' r I I u 1 a �17 6.3.4 Minimum Nailing — WeatherGuard® HP Hip and Ridge: Fig. A T v Pravaning Wind Direction Nails Nails I I A b I I I A I I I A I I I I I I Exp�s'— esuro "t Fig. C Hip & Ridge Shingle Fastening Top Vlaw Nails Nalis 11 Exposure 12 Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R8 Certificate of Authorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017 Page 7 of 8 6.3.5 Minimum Nailing - ProEdge Hip & Ridge Shingles: Prevailing Wind Direction Sealant Strip B' Exposure Fasten 7Il Cover Exposed Fasteners with Roof Cement �l TRINITY ERD Standard �1f■-. Fastening Pattern ca 2 j' �H pumm CatNn9 SumNaN• • r 12' $salient I 7110 ExpasuIre I dl� 6.3.6 Minimum Nailing — DuraRidgeT" Hip & Ridge Shingles: Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. Pranlins Wind Dir•elicn Dire ctiondo inant•duxent DlroadBn del rl" prodornimnte < Hdhl- Cluuo f 1 aaar� I e i I I I P !I• Top vlan vue en plan VbtaI 1-r"r I -y ca 2 j' • pumm CatNn9 SumNaN• • [O,.w I I dl� CIO iJJ �s I l� 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC— QUA9625 ; (631) 546-2458; Kanchi.Agrawala-Dokania@ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R8 Certificate ofAuthorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-1113 Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017 Page 8 of 8