HomeMy WebLinkAboutWind Load Calculation =EE ,. -MWINDOWSOLUTIONS NewS0 2526 Okeechobee Blvd,West Palm Beach,FL 33409•561-712-9000•CRC 1330822 Property Information Building Information Owner: JOHN&KAREN BARNES Wind Zone: 170 MPH. Address: 105 QUEENS ROAD Exposure Category: C HUTCHINSON ISLAND,FL 34949 Minimum Building Dimension: 25 ft. Mean Roof Height: 15 ft. K ilk Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) IL Pressure(psf) 1 Int 35.75 70.75 7 36.4 -39.6 2 Int 72.25 31.75 7 36.7 -39.9 3 Int 36 70.75 7 36.4 -39.6 4 Int 36 70.75 7 36.4 -39.6 5 Int 72.75 22.75 7 37.3 -40.5 6 Int 17 28.75 7 37.8 -41.0 7 Int 51.75 61.75 7 35.8 -39.0 8 Int 24.75 37 7 37.8 -41.0 9 Int 24.75 37 7 37.8 -41.0 10 Int 51.75 61.75 7 35.8 -39.0 11 Int 51.75 61.75 7 35.8 -39.0 12 Int 51.75 61.75 7 35.8 -39.0 13 Int 52 22.75 7 37.8 -41.0 14 Int 52 22.75 7 37.8 -41.0 15 Int 95.25 95.50 7 33.3 -36.5 16 Int 47.25 22.50 7 37.8 -41.0 17 Int 47.25 22.50 7 37.8 -41.0 18 Int 141.25 95.50 7 32.3 -35.5 19 Int 70.50 95.50 7 34.0 -37.2 20 Int 70.50 22.75 7 37.5 -40.7 21 Int 35.75 70.75 7 36.4 -39.6 22 Int 71.50 95.50 7 34.0 -37.2 23 Int 35.75 70.75 7 36.4 -39.6 24 Int 25.25 49.25 7 37.8 -41.0 FILEUI%ao Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1