Loading...
HomeMy WebLinkAboutBuilding Permit Application (2) 0rowarcl Teh 954.79Z�4415 Florida Ho.CGC061890/ t/4141118 es ` Miami Dade:3055454469 Licence No.CGC 061890/4844819 ILrlr� ( + Fax:954-792.2170 30a45w42"'SG.ft.latrdordalc,ft31112 FLORIDA Web;www. COM — HOME [mail:Info@ I. uc,e /-� T r IMPROVEMENT l.E1VE� Job: �1 D U L� ASSOCIATES Replacement Windows Contract B 01 2019 r� r Ot4ner. G?,j G� ev ,.cl.Cl_;. _- .---llonYcph:I. �e7Q r (T All.Ph: —) / County, Permitting Co•Owncr -� @mall: Url/ La/t^ Ur�� Addro�s City County State Zip r r- This Conjtact is made and enlored Into tills (_day of fl ttvG 7.0Ir by and between Florida Home Improvement Associates,Inc,a Florida Cot potation known as("(011tOctor"or"FMA"j,and OwnerIs) lamed above of the properly located at the address listed above known as ('Owner'):The Contractor onloes to perform the work described below at the property listed above: Ilk DIV, a�•� "ter t) t cmove ewtinf;unfit to be teplaccd INotr:Removed penis tilt hlely to be damaged.) .u• Prr yr o onto•as nr c�stiar to rrtciverrnwccmenl units •coca a,a•d.v. �- 3) tvindowst ^(' fNb1 Energy Storm Saver Atuminuni Insulated Aluminum Non-lnsulmed ono.�+..n..nwnwn.. 4) noors; ` fllA%Energy yStotni Saver Alunilnum lrsuLited Aluminum Non tniuiated uu..dw•i+w ur:! Glass: [bi,-Atae (14pact jNon-Ittipact'l'FrameCoior:Whiter_Bronze:_0/W Tan:_,Grey:�Mill: DoutifeHune Sinrle�NunQ Z to. Casement Ektdrrurndnw Yes i 40 Qty:— Qtyi:"L QtyQty:_ Qty: AFA Standard ' Custom Active Fixed FA AF LH RH 1/4.1/2.1/4 Active' Active m ❑. Qty: 1/3.1/3-1/3 Sliding Glass Door Single French M Geome nc1-'- 5) City: AA AF FA FAAF Door Qty:_ QIRH .( ) LH ,( ') Work to be completed as stated on the accompanying worksheet.Work NOT to be completed: initial Here- G) Ifapplitable,removing shutter panels, d/or Security bars.KeepwithOwn r Discard flat He 7) Special instructions, �a �:•>ti �t'gia Writl •vf y tf41t. 7 8) Cleanup job debris and provide necessary permits and insurance.If applicable,in the event that Contractor is unable for whatever reason to obtain proper' permits prior to commencement of any work Contractor shall refund any previous payment and this transaction shall be automatically c ncelled. 9) tional Work: No(ini h wo I I er than n @alai l anatio is to be done unle jed below). ��� YZ .� �„✓. wv t�tk fir. , Warranty!Contractor will provide warranty informationjo Owner`within 30 days after completion and final payment., the I :"Contractor shall commence th work within /f� days after execution of the Contract(Thea"Commencement Date)and shall endeavor 'to.complete all work Hereunder within days after the Commencement Date. jj By selectingthe finance option for the partial or Wit payment of this project.The Owner agrees to sign all finance completion forms the final day of installation.The scheduling and.completic n of the final Inspection will be scheduled for the next available-day and M checklist items,parts, ,replacement or damaged product reorders will be completed in a timely manner as part of our service'policy. -Initial Here Notice to the owner,if financing is being obtained by Owner: a) Do not sign this Contract or any financing document in blank,You are entitled to a copy.of the contract at the time you sign. b) `The financial docurtients provided by the lender to this home improvement contract(hay(teate a lien on your property. c) Be sure you understand all provisions of the Contract and financial documents before you sign. ,TOTAL PRICE 15—o-'1_5D an Deposit to order: S Yd Ol7 Ao Sales tax: 5� 1 .00 Payment Day lob:Starts- $ 00 Total Project: 5 ��r D :00 installation Completion: $ `ko • 0 miscelianeous This Contract and the accompanying worksheet contain the entire agreement between the parties.By signing this Contract;Owner agrees and.acknowiedges that it has received theaccompanyin8 worksheet.This Contract may not be changed orally but only by aChange'Order or other written amendment signed by both parties.The waiver by any party of a breach of any provisions of this Contract shall not operate or Ire construed as a waiver of any written amendment or waiver of any subsequent breach by any party.You the buyer may cancel this Contract at any time prior-tomidnightthe third business day after the date of this Contract. In witness whereof,the parties hereto have read,understand and agree to both sides of this Contract.Se mea explicado el contrato en su totalidad y entlendotodas las condiclones de'este contrato.Bath parties execute this Contract and the owners)agree to pay the balance due under this Contract under seal as of the day and"ear first above written: (faxv_�a lam ' Owner Print Co-owner Print Contractor Representative Print- OwnerSignature Co-Owner Signature Contractor Representatives,. nn••r n•u�.rn ••-,•nom.•+.nu. .._�._. G.._...L.—a Zi,6 .r .,�___. —.7�..�_3Iq yy']y 1/17/2019 142189_147372_1.jpg(800x800) RECEIVED FEB O 12019 I r ` ST. Lucie County, Permitting �NVPD :. 35 (2940} 3A fq v :a - ;� 5LOW . . .. 15 445: • ;;E�S`C=CA 3 -3 �jGAA hftps://www.ppslc.org/imageSketches/sketch/1421142189-147372-1 jpg CS ' n Specialty Engineering Consultants,Inc. ,�ticlxEFp� Wind Veloches in South Florida n 5 1599 SW 30 Avenue,Suite#20 Boynton Beach,FL 334326 ,�` s Dada Broward Palm Bmolt n a FL.CA#009217 �, Risk Cat.I 165 156 156 Low risk to humans farms sheds 5 J, Risk CaL2 175 170 170 Sin Ic Famil Residmus rui S\\� Risk Cal.3&4 186 180 1 180 Eso,dal Facilides P:=q h'(GCP- GCp i� Intstuctions and limitations of Use 1 Charts provide wind pressures based on the mean roof height.And shall not exceed 60'•0'. 2 Des'n ressures are for an enclosed builindin shutters or other impact resistance protection required). V(mph) 170 1620 FBC for HVHZ,or Fig.26.5-1a 3 User shall determine the mean roof height, Eave height+Roof Peak)12. Risk Category 11 Table 1.5-1,page2 4 End zone distance is the lessor of 10%of length,10%of width,or 40%of the mean roof height and not less than 3'-0• Exposure C Section 26.7 5 If 50%of a component Is in a particular zone then that component Is considered to be In zone with the majority of the area.If questionable then place in Zone 5 Kd 0.85 Tabic 26.6-1,page 250 6 Each component,window,door,mullion has a tributary area that is area to be used.Area of components to rounded down but shall not be less than 10 at. KrA I Figure 26.8-1,page 252 7 For NDA's that require a Kd=1.0 then multiply the values listed herein by 1.18. GCpi 0.18 -0.18 0.55 8 Wind ressures are based on Allowable stress design. pitch ofroof 3/12 14.0 degrees 9 Design pressures listed herein are valid for Exposures B and C and exposure D. max reef height 30' theta 14.0 degrees 10 Charts and values listed herein are only valid when signed,dated and sealed by Gary McDou le,PE#58214 or Mark LeBlanc PE#35683 or Adam D.LeBlanc,PE#77012 011 Wind design ressures are calculated in accordance with ASCE 7-10,Method 2.This calculation is vaild for FBC 2014 5th edition and 2017 6th edition 12 No reduction is taken for slopes less than 10 degrees. Arcs orconaponcra Arca 0i'mrapaUcaL Arca ofcomponan Arc ofoam wt Arca orcomponent Arm orweepence, Arca ofwm onml Arca ofwm mt Armofwm ma Ares ofwm twt Arcofcom nun 10.Osf 15.0sf 20.0 s1' 25.0 sf 30.M 35.0sr 40.0 sf 45.0 sf 50.Os'f 55.0 sf 6U.M Mean Roof Hci i Zone Zone Zone Zones Zone4 Zones Zone Zone Zone Zones Zone Zone Zone Zone Zone4 Zone Zone Zone Zone Zones Zone Zones 37.8 37.8 36.6 36.6 36.2 36.2 35.8 35.8 35.4 35.4 35.0 35.0 34.6 34.6 34.2 34.2 33.8 33.8 33.4 33.4 33.0 33.0 15 -41.0 -50.6 •39.8 -48.4 -39.5 -47.7 -39.1 -47.0 -38.7 -46.3 -38.3 45.6 -37.9 -44.8 -37.5 -44.1 -37.2 -43.4 -36.8 42.7 -36.4 42.0 38.3 38.3 37.1 37.1 36.7 36.7 36.3 36.3 35.9 35.9 35.5 35.5 35.1 35.1 34.7 34.7 34.3 34.3 33.8 33.8 33.4 33.4 16 41.6 -51.3 -40.4 49.1 40.0 -48.4 -39.6 -47.6 -39.2 46.9 -38.8 -46.2 -38.4 45.5 -38.1 -44.7 -37.7 -44.0 -37.3 43.3 -36.9 -425 38.8 38.8 37.6 37.6 37.2 37.2 36.7 36.7 36.3 36.3 35.9 35.9 35.5 35.5 35.1 35.1 34.7 34.7 34.3 34.3 33.9 33.9 17 -42.1 -52.0 -40.9 -49.7 40.5 -49.0 -40.1 -48.3 •39.7 -47.5 -39.3 -46.8 -38.9 -46.0 -38.5 -45.3 -38.1 •44.6 -37.8 -43.8 -37.4 43.1 39.3 39.3 38.0 38.0 37.6 37.6 37.2 37.2 36.8 36.8 36.4 36.4 35.9 35.9 35.5 35.5 35.1 35.1 34.7 34.7 34.3 34.3 18 -42.6 -52.6 41.4 -50.3 41.0 49.6 40.6 48.8 -40.2 48.1 -39.8 47.3 -39.4 46.6 -39.0 1 45.8 -38.6 45.1 -38.2 44.3 -37.8 -43.6 39.7 39.7 38.5 38.5 38.0 38.0 37.6 37.6 37.2 37.2 36.8 36.8 36.4 36.4 35.9 35.9 35.5 35.5 35.1 35.1 34.7 34.7 19 43.1 -53.2 -41.9 -50.9 •41.5 -50.2 41.1 49.4 -40.7 -48.6 40.3 -47.9 -39.9 47.1 -39.5 -46.4 -39.1 -45.6 -38.6 44.9 -38.2 44.1 40.2 40.2 38.9 38.9 38.5 38.5 38.0 38.0 37.6 37.6 37.2 37.2 36.8 36.8 36.3 36.3 35.9 35.9 35.5 35.5 35.1 35.1 20 1 43.6 -53.8 42.3 -51.5 41.9 -50.7 41.5 -49.9 41.1 49.2 -40.7 -48.4 -40.3 47.6 -39.9 46.9 -39.5 46.1 -39.1 -45.3 -38.7 44.6 40.6 40.6 39.3 39.3 38.9 38.9 38A 38.4 38.0 38.0 37.6 37.6 37.1 37.1 36.7 36.7 36.3 36.3 35.8 35.8 35A 35.4 21 •44.0 -54.3 1 •42.8 -52.0 42.4 -51.2 -41.9 -50.5 41.5 49.7 -41.1 48.9 40.7 -48.1 40.3 •47.4 -39.9 -46.6 -39.5 -45.8 -39.1 -45.0 41.0 41.0 39.7 39.7 39.2 39.2 38.8 38.8 38.4 38.4 37.9 37.9 37.5 37.5 37.1 37.1 36.6 36.6 36.2 36.2 35.8 35.8 22 -44.4 -54.9 43.2 -52.5 42.8 -51.7 -42.4 -51.0 41.9 -50.2 41.5 49.4 41.1 48.6 40.7 47.8 40.3 47.0' -39.9 46.3 -39.4 45.5 41.4 41.4 40.0 40.0 39.6 39.6 39.2 39.2 38.7 38.7 38.3 38.3 37.8 37.8 37.4 37.4 37.0 37.0 36.5 36.5 36.1 36.1 23 44.9 -55.4 43.6 -53.0 43.2 -52.2 -42.8 -51.4 -42.3 -50.6 -41.9 -49.9 -41.5 49.1 41.1 -48.3 40.7 47.5 40.2 -46.7 -39.8 45.9 41.7 41.7 40.4 40.4. 40.0 40.0 39.5 39.5 39.1 39.1 38.6 38.6 38.2 38.2 37.7 37.7 37.3 37.3 36.9 36.9 36.4 36.4 24 -45.3 •55.9 44.0 -53.5 -43.6 -52.7 -43.1 -51.9 42.7 -51.1 42.3 -50.3 41.9 49.5 48.7 •41.0 -47.9 -40.6 -47.1 40.2 -46.3 42.1 42.1 40.7 40.7 40.3 40.3 39.9 39.9 39.4 39.4 39.0 39.0 38.5 38.5 38. 38.1 37.6 37.6 37.2 37.2 36.7 36.7 25 1 •45.7 •56.4 -44.4 -53.9 •43.9 1 -53.1 -43.5 -52.3 43.1 -51.5 42.7 -50.7 42.2 -49.9 41. 49.1 -41.4 1 48.3 40.9 47.5 40.5 -46.7 42.4 42.4 41.1 41.1 40.6 40.6 40.2 40.2 39.7 39.7 39.3 39.3 38.8 38.8 EN 38.4 37.9 37.9 37.5 37.5 37.0 37.0 26 46.0 -56.8 -44.7 -54.4 -44.3 -53.6 43.9 •52.8 43.4 -52.0 -43.0 -51.2 -42.6 -50.3 - -49.5 41.7 48.7 41.3 -47.9 40.9 47.1 42.8 42.8 41.4 41.4 41.0 41.0 40.5 40.5 40.1 40.1 39.6 39.6 39.1 39.1 38.7 38.7 38.2 38.2 37.8 37.8 37.3 37.3 27 -46.4 -57.3 -45.1 -54.8 -44.7 -54.0 -44.2 -53.2 -43.8 -52.4 -43.4 -51.6 42.9 -50.7 42.5 49.9 42.0 -49.1 41.6 -48.3 -41.2 -47.5 43.1 43.1 41.7 41.7 41.3 41.3 40.8 40.8 40.4 40.4 39.9 39.9 39.4 39.4 39.0 38.5 38.5 38.1 38.1 6 `11�� 28 46.8 -57.7 45.4 -55.2 45.0 -54.4 44.6 -53.6 44.1 -52.8 43.7 -52.0 43.2 •51.1 2. p,1 I„}76,i 7 -50.3 42.4 -09.5 41.9 48.7 5 A R -4-.41Y 43.4 43.4 42.0 42.0 41.6 41.6 41.1 41.1 40.7 40.7 40.2 40.2 39.7 39.7 1 89.3139.3 38.8 38.8 38.4 29 47.1 -58.1 45.8 -55.7 1 -45.3 -54.8 44.9 -54.0 -44.5 -53.2 44.0 -52.3 43.6 -51.5 -43.1 - -49 -42.2 ��� .� -4}.B'• ••-4$.2• Ll��i, 43.7 43.7 42.3 42.3 41.9 41.9 41.4 41.4 41.0 41.0 40.5 40.5 40.0 40.0 .�- 39.1 39. 38.6 gy.' 30 -47.4 -58.6 -06.1 -56.1 -45.7 -55.2 45.2 -54.4 -44.8 -53.6 44.3 -52.7 -43.9 -51.9 4. - lrl{ -43.0 -50 42.5, .,4•• -4. `^ -n No. 77012 C) o _* • I ® M' -a '• STAT OF � . 3 co GF. SS• •....... ��� FHA, DtA'fRAM.'SHEET NO CHANGE IN ���� rrioeid FENESSIZE FOR SROEPOSED. 3'Ir,; :.a rz mac ooQ wasesTw►set MEASURINGTick 11REASUREDA7E, FRANCISCO 01-23-2019 CUSTOMEfi'S'NAME. ;FHA LEAU:.NUflIlBEFt. . TNPE OF PROPERTY•: ROOF HElGHt; _FLOOR NUMBER,` 7oTAL L'#-OF FLQOR5 LEONARD 814004 HOUSE 14 1 1 FEB 01 2019 10101 CROSBY PL SAINT LUCIE COUNTY, FL 34986 ST. Lucie County, Permitting FILE UkUPY 3.0 ....................... ZDo 51-7/8 X 72-3/4 (+67.5/-70)Z5823.1 ONE 4 SHGC=0.21 U-FACTOR=0.3 5N d V'0 2 M O 5� r% VT Ko EGRESS 51-7/8 X 72-3/4 �- (+67.5/-70)FL 5823.1 ZONE 4 �3AT� SHGC=0.21 U-FACTOR=0.3 o x4'tj -91 N OFF M SN 25-1/4 X37-1/8 EGRESS OAV 16177 51-7/8 X 72-3/4 �.� 3.r ZONE 4 SHGC=0.21 (+67.5/-70)FL 5823.1 U-FACTOR=0.3 ZONE 4 {�.Q SHGC=0.21 U-FACTOR=0.3 72 X 36 (+/-67.5)FL 13010.4 ZONE 4 GaQ.vs�� SHGC 0 24 U-FACTOR=0.28 2' OPEN# 1 ELEVATION DETAIL 'ILE COPY PRODUCT APPROVAL NUMBER: 13010.4 OPENING IDENTIFICATIONS: 1 6/13/2018 Florida Building Code Online TV, 'yrs' U+filY s. FLORIDA,ORPAPTIVIONT OF. BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts Publications I FBC Staff I BCIS Site Map I Links I Search I Florida pr Product Approval M USER:Public User Product Aw2roval Menu>Product or ARolication Search>eRplWApplicationFL# I Lt: u%.0 PyApplication Type Code Version Application Status *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments RECEIVED Archived Product Manufacturer Custom Window Systems Inc. FEB m 12019 Address/Phone/Email 1900 SW 44th Avenue ST. Lucie County, Permitting Ocala, FL 34474 (352)368-6922 Ext 245 kpine@cws.cc Authorized Signature Kevin Pine kpine@cws.cc Technical Representative Jay Lathrop Address/Phone/Email 1900 SW 44th Ave Ocala,FL 34474 (352)368-6922 Ext 291 jlathrop@cws.cc Quality Assurance Representative Jay Lathrop Address/Phone/Email 1900 SW 44th Ave. Ocala,FL 34474 (352)368-6922 Ext 291 jlathrop@cws.cc Category Windows Subcategory Fixed Compliance Method Certification Mark or Listing Certification Agency Keystone Certifications,Inc. Validated By Steven M. Urich,PE O✓ Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440-05 2005 AAMA/WDMA/CSA 101/I.S.2/A440-08 2008 ASTM E1886-05 2005 ASTM E1996-05 2005 PA TAS 201/202/203 1994 Equivalence of Product Standards Certified By hftps://www.flor dabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgvQEb8FEH60Vrs5wFsWUkbaazonS2SDienp6keeguGfEA%3d%3d 1/3 6/13/2018 Florida Building Code Online Product Approval Method Method 1 Option A Date Submitted 05/30/2018 Date Validated 05/31/2018 Date Pending FBC Approval Date Approved 06/10/2018 Summary of Products FL# Model,Number or Name Description 13010.1 PW-8150 PVC Fixed Window PW-8150 PVC Fig/Fin Fixed Window Limits of Use Certification Agency Certificate Approved for use In HVHZ:Yes FL13010 R6 C CAC CAR 1 8-1357.odf Approved for use outside HVHZ:Yes FL13010 R6 C CACAR 138-16 .pjff Impact Resistant:Yes FL13010 R6 C CACCAR 1 8-562 RL[f Design Pressure: N/A Quality Assurance Contract Expiration Date Other:PW-8150,36"x 72"and 72"x 76"see installation 09/14/2019 detail for DPs. Large Missile Impact.In HVHZ may only be used Installation Instructions up to 30ft above grade. Glass complies to ASTM E1300-04. FL13010 R6 II CWS-433D.p Verified By: Lucas A.Turner 58201 Created by Independent Third Party: No Evaluation Reports FL13010 R6 AF EvalikepD11431D_W Created by Independent Third Party:Yes 13010.2 PW-8150 PVC Fixed Window PW-8150 PVC Fig/Fin Fixed Window,Continuous Head&Sill. Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL13010 R6 C GAG CAR 138-261e2.pdf Approved for use outside HVHZ:Yes FL13010 R6 C CAC CAR 138-705e2.& Impact Resistant:Yes FL13010 R6 C GAG CAR 138-706 2.fL Design Pressure: +67.5/-67.5 Quality Assurance Contract Expiration Date Other: Large Missile,Dp= +/-67.5 psf,Max.size 74 1/8"x 08/12/2019 72".Outer lite must be safety glass above 30 ft. in HVHZ. Installation Instructions Glass complies to ASTM E1300-04. FL13010 R6 II CWS-510C.pd Verified By: Lucas A.Turner 58201 Created by Independent Third Party: No Evaluation Reports FL13010 R6 AE Eva1RepDj510C.Pdf Created by Independent Third Party: Yes 13010.3 PW-8300 PVC Fixed Window PW-8300 PVC Fig/Fin Fixed Window, 120"x 48" Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL13010 R6 C GAG CAR 138-258e2.pdf Approved for use outside HVHZ:Yes FL13010 R6 C CAC CAR 138-481e2.W Impact Resistant:Yes FL13010 R6 C CAC CAR 138-482e2.pdf Design Pressure:+70/-70 Quality Assurance Contract Expiration Date Other: PW-8300, 120"x 48",DP= +/-70 psf. Large Missile 0.4/09/2019 Impact.Glass complies to ASTM E1300-04. Installation Instructions FL13010 R6 II CWS-373C.Pdf Verified By: Lucas A.Turner,P.E. FL PE#58201 Created by Independent Third Party: No Evaluation Reports FL13010 R6 AE EvalReoort373C.pdf Created by Independent Third Party:Yes 13010.4 PW-8300 PVC Fixed Window PW-8300 PVC Fig/Fin Fixed Window,120"x 48" Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL13010 R6 C GAG CAR 138-1093.E Approved for use outside HVHZ:Yes FL13010 R6 C CAC CAR 138-1320 e2.pd Impact Resistant:Yes FL13010 R6 C CAC CAR 138-250.pdf Design Pressure:+70/-70 FL13010 R6 C CAC CAR 138-274e2.odf Other: PW-8300, 120"x 48", DP= +/-70 psf.Large Missile FL13010 R6 C CAC CAR 138-457.pjff Impact. Glass complies to ASTM E1300-04. FL13010 R6 C GAC CAR 138-465.Wff FL13010 R6 C GAC CAR 138-534.Pdf FL13010 R6 C CAC CAR 138-730e2.pd FL13010 R6 C CAC CAR 138-739e2.pdf Quality Assurance Contract Expiration Date 03/16/2020 Installation Instructions FL13010 R6 II CWS-159E.pjff Verified By: Lucas A.Turner,P.E. FL PE#58201 Created by Independent Third Party: No Evaluation Reports FL13010 R6 AE EvalRenortIS9E.pd Created by Independent Third Party:Yes https://www.floddabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgvQEbBFEH6OVrs5wFsWUkbaazoriS2SDienp6keeguGfEA%3d%3d 2/3 6/13/2018 Florida Building Code Online B..kFriext a Contact Us::2501 Blair Stone Road,TaIlahassee F!32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Co right 2007-2013 State of Florida.::privacy Statement•:AccessihIM Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click here. Product Approval Accepts: M ® eGve`ck Ma Credit Card Safe https://www.floddabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgvQEb8FEH6OVrS5wFsWUkbaazonS2SDienp6kee9uGfEA%3d%3d 3/3 URNER 1239 Jabara Ave. North Port,FL 34288 ENGINEERING & Ph. 941-380-1574 CONSULTING, INC. FBPE C.O.A. #29779 Evaluation Report 159E September 7,2017 Product Description: Series 8300 PVC Fixed Window,Large Missile Impact,48"x 72"unit size DP55 or 72"x 76"unit size DP67.5 (DP65 outside HVHZ) Manufacturer: Custom Window Systems,Inc. 1900 SW 44h Ave, Ocala,FL 34474 Statement of Compliance: This report evaluates the above-listed product per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the requirements of the 6h Edition(2017)Florida Building Code including the HVHZ. The product testing standards performed are outlined below. Technical Documentation: 1) This report,prepared by Lucas A. Turner,P.E.,at 1239 Jabara Ave.,North Port,FL 2) Approval drawing CWS-159E,signed and sealed by Lucas A.Turner,P.E. 3) Test Reports NCTL-210-3954-01 and-lA, and NCTL-210-3955-01 and-lA,from National Certified Testing Laboratories, Orlando, FL,with Testing Performed: AAMA/WDMA/CSA 101/I.S.2/A440-08,ASTM E1886-05,ASTM E1996-05/09 and TAS 201,202,203 1994(TAS reports 3954-1A and 3955-1A signed and sealedby Gerard J.Ferrara,P.E.) 4) Supplemental Calculations to support CWS-159E, signed and sealed by Lucas A. Turner,P.E. Installation: Units must be installed according to approval document CWS-159E. Limitations of Use: This product: • May be used in O configuration in sizes up to 48"x 72"unit size at design pressures of+/-55 psf, or in sizes up to 72"x 76"unit size at design pressures of+/-67.5 psf in HVHZ or+/-65 psf outside the HVHZ,with max. glass daylight sizes as shown in CWS-159E • Is large missile impact resistant and does not require the use of shutters • May be used in the High Velocity Hurricane Zone • Requires outer lite in I.G.to be safety glass when used in HVHZ above 30 ft of grade • Requires glazing as shown in CWS-159E,with Kuraray(Dupont) SentryGlas Interlayer per Miami-Dade NOA 14-0916.1 It in DP65 or 67.5 units or Kuraray(Dupont)PVB Interlayer per Miami-Dade NOA 16-1117.021 in DP55 units • Requires Quanex(Mikron)white rigid PVC framing per Miami-Dade NOA 17-0206.1 Ot t I have evaluated the interlayer and framing materials in these Dupont and Quanex NOAs and find that they comply with the requirements of the 6t'Ed. (2017)Florida Building Code for use in this product. Certification of Independence: I do not have,nor do I intend to acquire,nor will I acquire, a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have,nor do I intend to acquire,nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. �y#i�t�iir► ��:�y`t! 1V�5' �.noter! �I— Lucas Turner -. : 582014017-09-1-6 W.—F— ro; •�: 07;24+20:00 13•; STATE OF 14um Lucas A. Turner, P.E. r►rO,�•,.,s� �,�e`�'�+�� FL PE#58201 Rk di YOAlA1-������ PICTURE WINDOW - LARGE MISSILE IMPACT GENERAL NOTES: 1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED WINDOW SYSTEMS TO COMPLY WITH THE FLORIDA BUILDING CODE(FBC),CURRENT EDITION INCLUDING THE HIGH VELOCITY HURRINCANE ZONE(HVHZ) 1900 SW 44TH AVE. AND IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS OCALA,FLORIDA 34474 DEFINED IN ASTM E 1996 PER THE FBC. WWWCW .CC 491/4° 731/4• 2.GLAZING OPTIONS:(SEE SHEET 3) MAX.OVERALL FLANGE WIDTH MAX.OVERALL FLANGE WIDTH 8100 PVC 48' 72• 3.CONFIGURATIONS:'0".ARCHITECTURAL SHAPES INCLUDE,BUTARE MAX UNITWIDTH MAX.UNIT WIDTH NOT LIMITED TO,THOSE SHOWN ON SHEET 2. PICTURE WINDOW 451/8" ITPACT GLASS DLO 691/8• 4.DESIGN PRESSURE RATING: GLASS DLO -NEGATIVE DESIGN LOADS BASED ON,TESTED PRESSURE AND ---- --A 4e ---------------- GLASS TABLES ASTM E-1300-001/09. -i -POSITIVE DESIGN LOADS BASED ON,TESTED PRESSURE,WATER F o p N w O O INFILTRATION TEST PRESSURE AND GLASS TABLES z w 0❑ ¢ Z w I I ASTM E-1300-04e01/09. w <p z}O=_o- 771/4° I I 5.ANCHORAGE:THE 33 1/3%STRESS INCREASE HAS NOT BEEN USED z z xU. 2¢~Lu 0_ 731/4• I I OVEMAY-RALL I I ETAILSIN THE EWNDLSIGN OOAD DURATION FACTOR CdF THIS PRODUCT.SEE =1.6 WAS 8 FOR USEDOFOR WOOD O U rR 0 z OC3D- p m O�RALL I I FLANGE i i ANCHOR CALCULATIONS. E 00:1 w Z O V HEIGHT F"-'m O Z HE B I I B I I 6.PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT O F f=I=-z- I I 76• REQUIRED. a tr }j p Op m I uNIxT I O I 7.ALL FRAMES ARE FULLY W ELDED. z a O_j 0)H 72• O a 2 tr0-v� UNITMAX I I HEIGHT I I 8.SERIES/MODEL DESIGNATION PW-8300. _~D: W w rn HEIGHT I I I I 4. F I O- 0: a. I I I 731/8• I I 9.THE DESIGNATION RAND O STAND FOR THE FOLLOWING: puurir 'r 691/8• I I GLASS 0=FDO=D SASH. `,`ol kjOREW GLASS g DLO I I ��py.•''CEN•• G•Q�i DLO I e I I 10.SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR ��V:v� SF'•.,y�. O I I LOCATION. t• No 58201 :�11 .9; STATE OF .14'ae ———— —— —— — 0 P R ;ate O 10 G A q •,,ss,,o 2212017 LucasTurner LUCAS TURNER,P.E. FL I#58201 2017-09-22 1239 ABARA AVE. NORTH ORT,FL 34288 11:45-04:00 PH. 1-380-1574 SHEET DESCIPTION: TABLE OF CONTENTS GENERAL NOTES AND ELEVATIONS GENERAL NOTES&ELEVATIONS.......I LOCATION MAX. UNIT SIZE DESIGN PRESSURE RATING IMPACT RATING DRAWN Sr. DATE: ARCHITECTURAL SHAPES...................2 GLAZING DETAILS.................................3 ANY 48" 72" +/-55 PSF ADE 05/05/07 SECTION VIEWS....................................4DWG#: REV.: EXTRUSIONS&B.O.M...........................6 NON- HZ „ „ +- LARGE MISSILE IMPACT CWS-159 E ANCHOR SCHEDULE&NOTES.........6-7 HVA 72 X 76 +/-67.5 PSF INSTALLATION DETAILS.......................8 SCALE: SHEET 1:20 1 OF 8 i CCS®tom• WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA,FLORIDA 34474 W W W.CWS.CC ' I 8300 PVC PICTURE WINDOW IMPACT L"1 FULL ELLIPSE P'OVA ? 3 <z3 FULL CIRCLEz w o <w Lu i w TOMBSTONE w z O z O F g Z >0w 0 0� 0��WpO F l a Z ZO Q W Z O < F?wmOz -z z 00v}iowmw W►/J W 0 p w O IL m WOU D. � a Ix a ,olI11t►u s",I 1/2 CIRCLE ,Os .OREl..0 vt No 58201 •�9 OCTAGON _ i TRAPEZOID 9Q; STATE OF :4` T NOTES: 1.SEE SHEETS 6&7 FOR DETAILED ANCHOR INSTALLATION REQUIREMENTS. 2.THRU FRAME-MASONRY,WOOD OR METAL OPENING. 9/22/2017 THRU FIN-WOOD OPENING. LUCAS#.TURNER,P.E. 58201 3.OVERALL SIZE MUST NOT EXCEED THE MAX.WIDTH AND HEIGHT OF FL A#RAA RECTANGULAR WINDOWS ON SHEET 1. 123H PORT,FL 34 NORTH ORT,FL 34288 4.ANCHOR SPACING FOR ARCHITECTUAL FLANGE AND FIN WINDOWS PH. 41-380-1574 MUST FOLLOW THE LAYOUTS SHOWN ON SHEETS 6&7,WITH ANCHOR SHEET DES11P ION: SPACING MEASURED ALONG THE LENGTH OF THE PRODUCT. 1/4 CIRCLE TRIANGLE ARCHITE TURAL SHAPES DRAWN BY: DATE: ADE 05/05/07 DWG#: REV.: CWS-159 E SCALE: SHEET 1:1 2 OF 8 i I WINDWINIDOW SYSTEMS 1900 SW 44TH AVE. OCALA,FLORIDA 34474 W W W.CW S.CC 4 8300 PVC PICTURE WINDOW IMPACT F pW0 wwod z WJ❑ W zOz Q:=?F o FUJ3}0-�= uj zZ � O Z.M;m WOO 1.OVERALL 1"OVERALL 0 O N OF U d=I-d 3/16'ANNEALED or TEMPERED 3/16"HEAT STRENGTH or TEMPERED z in 00:3?–I.- 6– 1/2"AIRSPACE Q F-?LL g O O LL Z 3/8°AIRSPACE <�-p}O}H–:x 0– 5/16"LAMINATED 7/16'LAM[GLASS H Ix F- ui }7 3:0 W 4LL'(nOW–z 1/8'ANNEALED Z S2 W O J H 3/16'HEAT STRENGTH d .090 DUPONT PVB INTERLAYER O W d (L�W rn .090 SENTRY GLASS IONOPLAST INTERLAYER 2 1/8"ANNEALED a ~ LL 3/16"HEAT STRENGTH U RASEAL GPACER 6 PURFECT GLAZE'H' � ;.......... SIKAFLEX 552 IGUANEX DRURASEAL g PURFECT GLAZE"H" ;Gp�?-"C E NF SPACSIKAFLEX 552 7 No 58201 '�-A 10 1/2"GLASS BITE 10 1/2"GLASS BITE *' 77 90; STATE OF ;W 1 Elj oVED GLASS TYPE AT GLASS TYPE B 9/22/2017 LUCAS A TURNER,P.E. FL PE#58201 1239 4ABARA AVE. NORTH PORT,FL 34288 PH.�41-380-1574 SHEET DESCI tIPTION: GLAZ NG DETAILS GLASS MAXSIZE DR.S, DATE: SETTING BLOCKS PER FBC 2411.3.3.1 TYPE W X H ADE 05/05/07 DP +/-55 A 48 X72 DWG#: REV.:. CWS-169 E DP +/-67.5 B 72 X76 —E: SHEET 1:1 3 OF 8 -M WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA,FLORIDA 34474 W W W.CW S.CC INTERIOR 7 6 6 9 9 6 8300 PVC PICTURE WINDOW o S 6 IMPACT 7 7 1 ;� z l3 Qz� w WW o 10 w zoz wrzW 0 f!�3>.Ozi.m z HBj ZI-wo= Z Z=2QO_'Wpp 11 HdU uw- a- u) 8 9 bn-ZUw ojSECTION VIEW B-B zzO F- wpaZ LLJ 10 11 11 10 Q �apU) o Zd1W OJfAF- p wF=ISO a=�M Zt W a ~ D. wIt w- a INTERIOR `,, p96118111"1 ��PS"•" S G,Q�i Plo 58201 t q3 :13% STATE OF :IJJ �oF•eL0RIOPG���`� 11 B 9 fONA i 10 ❑ y�_ f 2 J�� �Q 9/.TUR17 U u LUCAS A.TURNER,P.E. FL QE#58201 1239 JABARA AVE. NORTH PORT,FL 34288 7 6 PH.941-380-1574 SHEET DESCIIPTION: SECTION VIEW A-A SECTION VIEWS ALTERNATE FIN FRAME DRAWN BY: DATE:ADE 05/05/07 DWG#: REV,: CWS-159 E SCALE: SHEET 1:1.33 4 OF 8 PARTS LIST FRAME CORNER CONSTRUCTION ITEM PART# DESCRIPTION VENDOR MATERIAL ` WINDOW SYSTEMS /(✓I�J�� 1 H-6006B FRAME, PW, MAIN, HEAD MIKRON PVC 1900 SW4TH AVE. OCALA,FLORIDA 34474 H-6006B FRAME, PW, MAIN, SILL MIKRON PVC WWW.Cws.Cc H-6006B FRAME, PW, MAIN, L. JAMB MIKRON PVC 4 H-6006B FRAME, PW, MAIN, R. JAMB MIKRON PVC CORNERWELD(ALL SIDES) 8300 PVC 5 H-6006A FRAME, PW, MAIN, FIN MIKRON PVC SCALE I:8 PICTURE WINDOW 6 P-3113 SCREW SUPPORT FOR PVC TEAM PLASTIC RUBBER IMPACT 7 P-3352 SET. BLK., 85 DUR., 1/8"x 5/8"x 2" LG. FRANK LOWE RUBBER 1 8 PURFECT GLAZE "H", SIKAFLEX 552 HENKEL/SIKA SILICONE a z I a Z 9 P-3752 CAP PLUG, 1/2" HOLE M&M SILICONE z w'w 00 ¢k Z w w zoz D:_—t= 10 S-6064 GLZ BE., FXO. (1"O.A. I.G.) MIKRON PVC o �w�z°w� 11 GLASS ISEE SHEET z zxm¢wwoo v 0 za��a Z O --g 31/8' 31/8° } Q?LLWO=LLOZ o �~~LZ o on w0WU)W LL Cd Wa 0-10E- 1 2 3 4 5 0 re 0 Lu a.m ml- �I Lu as � a ��a. 21/16' 1/18° 1/16° ,,`pouts"', Q ..........W t•.,. 2 7/8° o 58201 '�13 Z9 S 8, ATE OF ,4U 1 1/2' �O,ri•,A%L O �� PVC FRAME FLANGE-H-60068 �1' '•,��c�`ss.°,••a: I'll PVC E: F9F'�' 7 PVC FRAME FIN-H-6006A Z� 1/a° 9/22/2017 LUCAS A.TURNER,P.E. 1/16" 1/2' 3' FL PE#58201 718' 10 L 123JABARA AVE. .11 33/16" s NORTH PORT,FL.34288 T— PH.941-380-1574 SHEET DESCRIPTION: PVC GLAZEBEAD-S-6064 SCREW SUPPORT-P-3113 EXTRUSIONS&B.O.M. DRAWN Sr. DATE: ADE 05/05/07 DWG#: REV.: CWS-159 E SCALE: SHEET 1:1 5 OF 8 14'MAX O.C.(TYP.) ® •Il l II/i1 6°MAX(TYP.) SEE NOTE 2 4"MAX(TYP.) 8°MAX O.C.(TYP.) SEE NOTE 2 WIN900 SSW TSV ESS 4°MAX(TYP.) 6'MAX(TYP.) OCALA,FLORIDA 34474 ---------- ---------- WWW.CWS.CC I I I I I I I 8300 PVC 8• I I PICTURE WINDOW MAX O.C. I I "P.) INSTALLATION INSTALLATION I I ANCHOR(TYP.) MAX .C. IMPACT 1 I I ANCHOR(TYP.) I I I I I P: ❑to Nw0d Z wJ❑ I I I o Q°3>.0 3: I I I I w F-W z1-3m2 Z zx�<QrwpO O OF-OUQ=F (Y U UyF- al...ma I I I I I I I I } 0z6,:zoc )aW°° ?Ox0 W O0lY.0)0w fnw rn I I I I R Zw O_jv)F- I I I I p wiE0 'HS ---------- ---- a la w3nw �un,u+p ANCHORLAYOUT- FLANGE) ANCHOR DP+LA (FIN) ,V^c DIP 55 PSF5 PSF lo REW�•°582016°:41 9 .!3 ATE OF NOTES: 1.INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION.ANCHOR SPACING APPLIES TO ALL SHAPES(SEE SHEET 2)ALONG ALL FRAME EDGES. SILL ANCHOR SPACING SAME AS HEAD. 2.SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX ALLOWABLE SHIM STACK TO BE 1/4•. USE SHIMS WHERE SPACE GREATER THAN 1/16°IS PRESENT. LOAD BEARING SHIMS SHALL BE �Z CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED. 3.ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 8. 9/22/2017 4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST LUCAS A.TURNER,P.E. FL PE#58201 BE PROTECTED TO PREVENT REACTION. 1239 JABARA AVE. 5.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM NORTH PORT,FL 34288 SPECIFIED IN TABLE 1,SHEET 8. ' PH.941-380-1574 SHEET DESCRIPTION: 6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE. INSTALLATIONS TO SOLID CONCRETE OR GROUT-FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. ANCHOR SCHEDULE& INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. MOTES 7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:3"FOR MASONRY,1"FOR WOOD AND METAL. DRAWN Sr. DATE:ADE 05/05/07 8.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BYTHE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. DWG a: REV.: SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 8. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. CWS-159 E 9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: SCALE: SHEET FMA/AAMA 100(FIN WINDOWS),FMA/AAMA 200(FLANGE WINDOWS), FMAANDMA 250(BOX WINDOWS),FMA/AAMANVDMA 300(EXTERIOR DOORS) 1:20 6 OF 8 ®�. WIINDO SYSTEW9S 4°MAX(TYP.) 8•MAX O.C.('YP.) 6•MAX(TYP.) 7 5/8•MAX.O.C.(TYP.) SEE NOTE 2 4•MAX,(TYR)� SEE NOTE 2 WWW.OCALAW cc 34474 1900 SW 4-TH AVE. 6•MAX(TYP.) WWW.CW .CC -- -------————————— ———————————————— I j 8300 PVC 6• I I PICTURE WINDOW OW 5/e• I I MAX O.C. I I I PACT (cryp.)MAX .c. I I (TYP.> I I IyI I I I a z 3 azo I I I z w-io <�Zw O I I INSTALLATION II O II ( LLI QOANCHOR(TYP.) ANCHOR(TYP.) 32Z Z= a- O OF7OzPaUUU,F y I I I z 0(29:3 E)O- I I I a F-?,_2oou -Z }O}AF=�_�- H 00E-yD'y92 I W OLL ia 0D:m0 WCaW I I I a iw0`"ai I I I °r =' jw W=, CO I I I D. F- a X (L ---------------- ———————————————— suujorl" �10REW (FLANGE) ANCHOR '�G EN g ANCHOR LAYOUT-(F ANCHOR LAYOUT-(FIN) M o 58201 :�1) DP+/-65PSF DP+/-65PSF • ° 9; STIATE OF °•(u: iO •C .�uC OR NOTES: '���SS�0NP� . o,` 1.INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION.ANCHOR SPACING APPLIES TO ALL SHAPES(SEE SHEET 2)ALONG ALL FRAME EDGES. SILL ANCHOR SPACING SAME AS HEAD. 2.SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX ALLOWABLE SHIM STACK TO BE 1/4°. USE SHIMS WHERE SPACE GREATER THAN 1/16°IS PRESENT. LOAD BEARING SHIMS SHALL BE a� CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED. 3.ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 8. 22/2017 4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST LUCAS A.TURNER,P.E. FL rE#58201 BE PROTECTED TO PREVENT REACTION. 1239 JABARA AVE. 5.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM NORTH PORT,FL 34288 SPECIFIED IN TABLE 1,SHEET 8. PH.941-380-1574 6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR COSHEET DESCRIPTION: NCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE. INSTALLATIONS TO SOLID CONCRETE OR GROUT-FILLED CMU MAY INCLUDE BUT DO NOT REQURE 1X WOOD BUCKS BETWEEN THE PRODUCTAND SUBSTRATE. ANCHOR SCHEDULE 8 INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. NOTES 7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:3•FOR MASONRY,1"FOR WOOD AND METAL. DRAWN BY: DATE:ADE 05/05/07 8.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. DWG a: REV.: SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 8. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. CWS-159 E 9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: SCALE: SHEET FMA/AAMA 100(FIN WINDOWS),FMA/AAMA 200(FLANGE WINDOWS), FMA/WDMA 250(BOX WINDOWS),FMA/AAMA/WDMA 300(EXTERIOR DOORS) 1:20 7 OF 8 MIN.EMBEDMENT QWINDO&YSEE TABLE 1 SUBSTRATE EYWS TYPICAL HEAD ANCHORAGE BY OTHERS i 1/4"MAX.SHIM SEE TABLE 1 MIN.EDGE DIST. SUBSTRATE 1900 SW 44TH AVE. `� SEE TABLE 1 BY OTHERS OCALA,FLORIDA 34474 MIN.EDGE DIST. I SEE TABLE I WWW.CW .Cc SEE TABLE 1 1/4'MAX SHIM MIN,EDGE DIST. SUBSTRATE BY OTHERS SEE TABLE 1 SEE TABLE 1 S OO PVC MIN.EMBEDMENT SEEMIN.EM LE i INSTALLATION ANCHOR PICTURE WINDOW PERIMETER SEALANT SEE TABLE 1 INSIDE ANDER ❑� SEE A INSIDE AND OUT SEE TABLE 1SEALANT BEHIND I I,i+PMCT n o4 I FLANGE BY INSTALLER �p �0 "= z Q z O 1/4".MAX.SHIM H O d to w a s ❑ �u PERIMETER SEALANT z W90 ¢r Z w PERIMETER SEALANT BY INSTALLER w z O z 0:_-t BY INSTALLER INSIDE AND OUT n F W?�z O'S 2 S INSIDE AND OUT INSTALLATION ANCHOR z z y 2 Q SEE TABLE I d O F-O(3 s�w SEALANTR GEBYENSTALLER SEALANT BEHIND p BHIND Z z t-�co FIN BY INSTALLERZ z O U t/J z U U INSTALLATION ANCHOR g HORIZONTAL SECTION C HORIZONTAL SECTION } ¢-LL d S LLO z SEE TABLE i 8 TYPICAL JAMB ANCHORAGE 8 TYPHEAD ICALAND ILL SIMILAR FOR FIN INSTALLATION I,FIN ANCHORAGE 2 d H F z SO }� O W LL Krn Owcow - ZUi1w OJVJh CL 50- �U-ur X ra� w 3:w� F ID- It n ❑ purrrrrr �"'� 1/4'MAX.SHIM ++ SEALANT BEHIND .♦'G�•':.�G E k S�•;,ply FLANGE BY INSTALLER J ter; No 58201 :aI PERIMETER SEALANT 'tt� BYINSTALLER MIN.EMBEDMENT INSIDE AND OUT SEE TABLE 1 r,0 ;•S AOTEI OF .4v SUBSTRATE BY OTHERS ry InurH��� SEE TABLE 1 MIN.EDGE DIST. SEE TABLE 1 SEALANT UNDER SCREW A VERTICAL SECTION _ HEAD BY INSTALLER 8 TYPICAL SILL ANCHORAGE �(1 22(2417 TABLE 1:APPROVED INSTALLATION FASTENERS LUCAS Q.TURNER,P.E. FRA FL PE#58201 LANGE CONCRETE(2.0 KSI MIN.) 3116"ITW TAPCON 1-1/2" 1-118" PERIMETER SEALANT 1239 ABA,Fl.34 FLANG 6Y INSTALLER NORTH ORT,-1 34288 INSIDE AND OUT PH.941-3601574 FLANGE CONCRETE(2.85 KSI MIN.) 3/16"ELCO ULTRACON 1" 1" D HORIZONTAL SECTION!_ SHEET DESC IPTION: FLANGE GROUT-FILLED CMU(ASTM C-90) 3/16"ELCO ULTRACON 1-1/4" 2-1/2" 8 BOX FRAME INSTALLATION FLANGE 2X MIN,SOUTHERN PINE(G=0.55) 1-318" 3/16"ITW TAPCON 718" i HEAD AND SILL SIMILAR FOR BOX INSTALLATION INSTALLf TION DETAILS OR ELCO ULTRACON FLANGE 2X MIN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1-3l8" 7/8" FLANGE REMOVAL NOTE:PARTIALLY OR FULLY REMOVING THE FLANGE, DRAWN Sr. DATE: 16 GAUGE(0.060")MIN.STEEL STUD #10-16 HILTI KWIK-FLEXOR fTVV FULL THREADUP TO AND INCLUDING A BOX-FRAME APPLICATION IS ACCEPTABLE PROVIDED: ADE 05/05/07 FLANGE 7/16" DWctt: REV.: (33 KSI YIELD MIN} TEKS SELF-DRILLING SCREW THRU 0.460" -MIN.1/4"FILLET OF CONSTRUCTION-GRADE ADHESIVE CAULK IS APPLIED I FLANGE V8"ALUM.(6063-T5 MIN.)OR #10 GRADE 5 SELF TAPPING! FULL THREAD 7116" INSIDE AND OUT,FULL PERIMETER,BY INSTALLER. GWS-159 E 1/8"STEEL(33 KSI MIN.) DRILLING SCREW THRU 0.125" PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS SCALE: SHEET FIN 2X MIN.SOUTHERN PINE(G=0.55) #8 WOOD SCREW 1-1/2' 7116" SHOWN FOR FLANGE WINDOWS. 1:2 I $dF 8 I RLE CO PRODUCT APPROVAL NUMBER: 5823.1 OPENING IDENTIFICATIONS: 2,3,4 1/4/2018 Florida Building Code Online �o h? r Iii BCIS Home I Log In I User Registration Hot Topics I Submit Surcharge I Stats&Facts Publications I FBC Staff BCIS Site Map Unks Search jd Florida -. Product Approval USER:Public User r p Product Approval Menu>Product or Application Search>Application List>Application Detail • FL# FL5823-R8 FILE- Application Type Revision Code Version 2017 Application Status Approved RECEIVED Comments FEB 01 2019 Archived ST. Lucie County, Permitting Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenue Ocala,FL 34474 (352)368-6922 Ext 245 kpine@cws.cc Authorized Signature Kevin Pine kpine@cws.cc Technical Representative ]ay Lathrop Address/Phone/Email 1900 SW 44th Ave Ocala, FL 34474 (352)368-6922 Ext 291 jlathrop@cws.cc Quality Assurance Representative Arturo Monteverde Address/Phone/Email 1900 SW 44th Ave Ocala,FL 34474 (352)368-6922 Ext 221 amonteverde@cws.cc Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Lucas A.Turner Evaluation Report Florida License PE-58201 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 07/21/2020 Validated By Steven M. Urich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL5823 R8 COI Evallkeport155D.pdf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA/101/I.S.2/A440-05 2005 ASTM E1886-02 - 2002 ASTM E1886-05 2005 ASTM-E1996--02 2002 ASTM E1996-05 2005 PA/TAS 201/202/203 1994 hfps://www.floddabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgvMdF6zR4iHLrSiEW2m3mv6FSF7061cmWE%3d 1/3 1/4/2018 Florida Building Code Online Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/28/2017 Date Validated 09/29/2017 Date Pending FBC Approval 10/02/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 5823.1 8100 Vinyl Single Hung 8100 Vinyl Single Hung(Impact) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL5823 R8 II W -15 D.(L Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:Large Missile,see installation dwgs.for Max.size and FL5823 R8 AE EvalReport155D.ndf DP. Outer lite in I.G. must be safety glazed when used above Created by Independent Third Party: Yes 30 ft. in HVHZ.Glass complies to ASTM E1300-04. 5823.2 SH-8100 Cont. Hd. &Sill SH-8100 Cont. Hd.&Sill(double Single Hung),Impact,74 1/8"x 63". Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL5823 R8 II CWS-440C.1df Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other: Max. unit size 72-7/8"x 61-3/4". Outer lite in I.G. FL5823 R8 AE EvalRenort440C.pdf must be safety glazed when used above 30 ft. in HVHZ. Glass Created by Independent Third Party: Yes complies to ASTM E1300-04. 5823.3 SH-8100 Cont. Hd. &Sill SH-8100 Cont. Hd. &Sill(double SIngle Hung),Impact,74 1/8"x 72". Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL5823 R8 II CWS-491C.12df Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: +67.5/-67.5 Evaluation Reports Other:Large Missile,DP= +/-67.5 psf, Max.size 74-1/8"x FL5823 R8 AE EvalReoort491C.ndf 72". Outer lite in I.G. must be safety glazed when used above Created by Independent Third Party:Yes 30 ft. in HVHZ.Glass complies to ASTM E1300-04. 5823.4 SH-8100 Vinyl Single Hung Oriel SH-8100 Vinyl Single Hung Oriel Window w. HD FMR, 5 HI sash. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL5823 R8 II CWS-295E.PDF Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:+70/-70 Evaluation Reports Other: Large Missile,52"x 96"w/5 HI sash, +/-70 psf. FL5823 R8 AE EvalReport295E.pdf FLANGE ONLY.Outer lite In I.G. must be safety glazed when Created by Independent Third Party:Yes used above 30 ft. in HVHZ. Glass complies to ASTM E1300-04. Batik P1ext Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic malLto_this entity.lnstead,.contact the office.by_phone or-by_tradltlonalmall.lf-ynu haveany-questions,please contact 850.487.1395.-�Pursuent to_Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click here_. Product Approval Accepts: hftps://www.floddabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgvMdF6zR4iHLrSiEW2m3mv6FSF7061cmWEg/o3d 2/3 1/4/2018 Florida Building Code Online • IMM 01 ® RE • Credit Card Safe https://www.floddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvMdF6zR4iHLrSiEW2m3mv6FSF7O61cmWE%3d 3/3 URNER 1239 Jabara Ave. North Port, FL 34288 ENGINEERING & Ph. 941-380-1574 TCONSULTING, INC. FBPE C.O.A. #29779 Evaluation Report 155D August 28,2017 Product Description: Series 8100 PVC Single Hung,Large Missile Impact, 53 1/8"x 76"unit size at up to+/-67.5 PSF,36"x 62"unit size at up to+67.5/-75 PSF, 7/8"Insulating Glass consisting of 1/8 Annealed or Tempered outboard lite —Air—5/16 Laminated(1/8Ann-.090PVB-1/8Ann)inboard lite Manufacturer: Custom Window Systems,Inc. 1900 SW 44e Ave, Ocala,FL 34474 Statement of Compliance: This report evaluates the above-listed'product per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the requirements of the 6a' Edition(2017)Florida Building Code including the High Velocity Hurricane Zone. The product testing standards performed are outlined below. Technical Documentation: 1) This report,prepared by Lucas A. Turner,P.E.,at 1239 Jabara Ave.,North Port,FL 2) Approval drawing CWS-155D,signed and sealed by Lucas A. Turner,P.E. 3) Test Report NCTL-210-3668-1,4A, -2,-2A, 3669-1,4A,-2, and-2A,by National Certified Testing Laboratories, Orlando,FL, signed and sealed by Gerard J.Ferrara,with testing performed: TAS 201,202,203 1994,ASTM E 1886, 1996 2002/2005,and AAMA A440 2005 4) Supplemental Calcs. to support CWS-1551), signed and sealed by Lucas A. Turner,P.E. Installation: Units must be installed according to approval document CWS-155D. Limitations of Use: This product: • May be used in O/X configuration in sizes, design pressures,and with max. glass DLO heights as shown in CWS-155D • Is impact resistant and does not require the use of shutters • May be used in the High Velocity Hurricane Zone • Requires 7/8"Insulating Glass consisting of 1/8 Annealed or Tempered outboard lite(Tempered required above 30 ft in HVHZ) —Air—5/16 Laminated'(1/8Ann-.090PVB-1/8Ann)inboard lite • Requires Kuraray(Dupont)PVB Interlayer per Miami-Dade N.O.A. 16-11117.021 • Requires Quanex(Mikron)white rigid PVC framing per Miami-Dade N.O.A. 17-0206.101 1 I have evaluated the materials in these NOAs and find that they comply with the requirements of the 6`h Ed. (2017)Florida Building Code for use in this product. Certification of Independence: I do not have,nor do I intend to acquire,nor will I acquire, a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have,nor do I intend to acquire,nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. **lt�ttt�lrr�*# ►� _ , +i �1 RE LUCKS "*��• '• � Turner � � • ° 582 1 8/28/2017 2017=08=3 *-=--Lucas A—T-umer�'�. w^� ' FL PE#58201 15:59+20:00 10STATE of *QJ SINGLE HUNG - LARGE MISSILE IMPACT GENERAL NOTES: (SHOWN w/DIFFERENT OPTIONS) 1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED y�lp�®O'-yy'�SYST-EPNS• TO COMPLY WITH THE FLORIDA BUILDING CODE(FBC),CURRENT I EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVHZ)AND 1900 SW 4TH AVE. IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED OCALA,FLORIDA 34474 IN ASTM E 1996 PER THE FBC. WWWCW .CC AN 2.GLAZING OPTIONS:(SEE SHEET 2) OVERALL FLANGE WIDTH 8100 PVC 531/8'MAX.UNIT WIDTH - 3.CONFIGURATIONS:°O/X°. SINGLE HUNG OVERALL FLANGE WIDTH 4815/16" 4.DESIGN PRESSURE RATING: I�PA� GLASS DLO -NEGATIVE DESIGN LOADS BASED ON,TESTED PRESSURE AND . ' GLASS TABLES ASTM E-1300-04e01/09. FF AX UNIT WIDTH POSITIVE DESIGN LOADS BASED ON,TESTED PRESSURE,WATER 31 13/16• INFILTRATION TEST PRESSURE AND GLASS TABLES 0 I 0 a)W O 0 MAX ASTM E-1300-04e01/09. z w_j 0 a O w GLASS OLO Z OVERALL I I A 5.ANCHORAGE:THE 33 1/3%STRESS INCREASE HAS NOT BEEN USED O Q y�}O 2�m FLANGE LL I-w Z F-3 g= HEIGHT I - - IN THE DESIGN OF THIS PRODUCT.SEE SHEET 6 FOR ANCHOR O O I=-O 4�w O 0 O I DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD Li :1_w 3315116" L4" -�- ANCHOR CALCULATIONS. 0 Z y co Z Z~D D- GLASS I I I Z O o --:30- DLO OVERALL I 6.PRODUCT APPROVED FOR IMPACT RESISTANCE. THE IMPACT SWEEP Q H Z LL�p O IL O MAX I HEIGHT LOCKS ARE INTENDED TO BE LEFT UNLATCHED DURING NORMAL ¢�0 w-H OUNIT �g ? I HEIGHT B O B GLASS OPERATION BUT MUST BE ENGAGED PRIOR TO EXPOSURE TO ¢ } ?�p 62° DLO HURRICANE WINDS AND FLYING DEBRIS. 4'W 0 w 0)w d1 w MAX It Z_ O�tnF- UNIT 7.ALL FRAMES AND VENTS FULLY WELDED.SMALL JOINT SEAM SEALANT p w O aa.0 T 37 5/16 I I 6 HEIGHT i I USED AT FIXED MEETING RAIL AND JAMB. a r- I D- Lu a�a 8.SERIES/MODEL DESIGNATION SH-8100. MAX. I C 34° ,�Vttunptt SASH " I g GLASS 305116" 9.THE DESIGNATION XAND 0 STAND FOR THE FOLLOWING: J``,5 t ....... TREW `���� HEIGHT J� D DLO MAX SASHx X=OPERABLE SASH,O=FIXED SASH GP:��C EN ., 6 HEIGHT '` GLASS =�' 0 58201 ..�'Ar 10.SECTION CALLOUTS APPLY TO ALL ELEVATIONS INA SIMILAR 2 DLO * * i C I I I LOCATION. 11.EXTERNAL WEEP SLOT=1/4"x 1-1/4"LOCATED 4"FROM BOTH ENDS. Qom,• ^� ATE OR :ski` C eLL, Jr- A 12.SWEEP LOCKS INSTALLED ON WINDOWS OVER 36'x 62". 46 3/8• L 28! p tnur�H��� GLASS DLO GLASS DLO 4911/16. 31 5116" LucasTurne MAX.SASH WIDTH MAX SASH WIDTH r 9z 2017-09-22 9/22/2017 11:38-04:00 LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. NORTH,PORT,FL 34288 PH.941-380-1574 SHEET DESCR6TTION: DESIGN PRESSURE GENERAL NOTES AND A LOCATION MAX. UNIT SIZE RATING IMPACT RATING ELEVATIONS TABLE OF CONTENTS NO _ DRAWN BY: DATE: GENERAL NOTES..ELEVATIONS.....1 ADE 06/10/08 GLAZING DETAILS...LT............E.......3 I IVI IZ +/-67.5 PSF DWG 0: I REV.: SECTION VIEWS. ALT.FRAME........3 LARGE MISSILE IMPACT EXTRUSIONS$B.O.M.........................4 NO _ � + _ F CWS-155 D ANCHOR SCHEDULE 8:NOTES..........5 SCALE: SHEET INSTALLATION DETAILS.....................6 36"X 62"I"IVH7 +67.5/-75 PSF 1:1 1 OF 6 7/8'OVERALL INSULATED GLASS 7/8'OVERALL INSULATED GLASS , bm. 1/8'ANNEALED 1/8'ANNEALED WINDOM SYSTEMS 1900 SW 441 TH AVE. 7/16'AIRSPACE 7/16'AIRSPACE OCALA,FLORIDA 34474 5/16°LAMINATED GLASS 5/16°LAMINATED GLASS WWW.CW .CC 1/8"ANNEALED 1/8'ANNEALED .090"PVB INTERLAYER BY DUPONT .090°PVB 8100 PVC INTERLAYER BY SINGLE HUNG 1/8'ANNEALED 1/8"ANNEALED QUANEXDURASEAL QUANEXDURASEAL II PACT IG SPACER IG SPACER 18 PURFECT GLAZE'H'OR SIKAFLEX 552 18 PURFECT GLAZE'H"OR SIKAFLEX 552 Z I Q Z � O COWo 1 1/2'GLASS BITE 1/2"GLASS BRE WO Q W Z}0-IME � LL F-W�Zh� 2 Ni 38 7-0� ZC U�OUaF�a Zo Z ri)ZZF-nV) OZOv1Z�U- OOWZ 4 } < OWF=FO- F� yU-,Zvi W ��f�OW(nW w ZCod O-jv)F- fL = 2 W �fn GLASS TYPE A GLASS TYPE A CL F a W a. SASHFIXED LITE SASH LITE Py��11 RE Sa 9te �' t�o 58201 -:A% 7/8°OVERALL INSULATED GLASS 7/8"OVERALL INSULATED GLASS ?* 1/8'TEMPERED 1/8"TEMPERED ' '9: F TATE OF •&I 7/16"AIRSPACE 7/16"AIRSPACE 10.p'., C��i 5/16"LAMINATED GLASS 5/16"LAMINATED GLASS 1/8"ANNEALED 1/8'ANNEALED .090"PVB INTERLAYER BY DUPONT .090"PVB INTERLAYER BY DUPONT 1/8'ANNEALED 1/8"ANNEALED QUANEX DURASEAL QUANEX DURASEAL Z� IG SPACER IG SPACER 18 PURFECT GLAZE*H"OR SIKAFLEX 552 18 PURFECT GLAZE W OR SIKAFLEX 552 9/22/2017 LUCAS A.TURNER,P.E. 1 1/2"GLASS BRE 1/2'GLASS BITE 123FL 9 PE#5 201 • 38 . 38 NORTH,PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: 4 GLAZING DETAILS 0 I DRAWN BY: DATE: ADE 06/10/08 DWG#: REV.: GLASS TYPE B SETTING BLOCKS PER FBC 2411.3.3.1 CWS-155 D GLASS TYPE B SASH LITE SCALE: FIXED LITE SHEET 1:1 2 OF 6 INTERIOR ��+'�!s'��•p�L� WINDOV�SYSYEWIS 3 21 19 10 39 11 21 15 3 1900 SW 44TH AVE. OCALA,FLORIDA 34474 WWW.CW .CC 41 �0 41 8 00,PVC SINGLE HUNG 46 O II PACT z I 3 12 21 00 a QWow 20 12 20 26 w ZOZ D-'N~ 0 auk§}Ow3:m SECTION VIEW 13-13Z Z I:tc M a m w O O U UwA-z a-=-ya NOTE:LEFT SIDE SHOWS FIXED R RIGHT SIDE SHOWS AS SECTION SECTION EW.VIEW, zO 00=1 U to Z v a I--LL 00u.O moz 12 30 1 3:�pwo-5 3: w 38 0aWaiowV)w 31 29 a0 wF0 a.It m G: = 12' w�W� IL 5 -� d d d 7 INTERIOR 2 s �OREW 48 Al Ci is No 58201 x:'A � O (TATE OF .:'U� p.SS.• 'C1 12 13 14 U U u I 1s z2 25 O 22/2017 40 LUCAS .BA TURNER,P.E. FL E#58201 �o o is 1239 ARAAVE. 2 NORTH PORT,FL 34288 41 PH.?41-380-1574 SHEET DESCRIPTION:I SECTION VIEW C-C SECTION VIEW A-A SECTION VIEWS ALTERNATE FIN FRAME SWEEP LOCK REQUIRED NO SWEEP LOCKS ALLOWED FOR SIZES OVER 36"x 62". DRAWN BY: DATE: FOR UNITS 36"x 62"AND UNDER. ADE 06/10/08 DWG#: REV.: ITEMS NOT SHOWN FOR CLARITY: CWS-155 D 22,27-28,33-37,43-45 SCALE: SHEET 1:2 I 3OF6 I FRAME CORNER I PART# DESCRIPTION PARTS LIST MATERIAL VENDOR 31/8" CONSTRUCTION I H-6031 Frame Head,Fig,Single Flung PVC MIKRON WINDOW SYSTEMS 2 1-1-6031 Frame Sill,Fig,Single Hung PVC MIKRON 1 15116" 2 3116'— 1 goo SW 4TH AVE. OCALA,FLORIDA 34474 3 H-6031 Frame Jamb,Fig,Single Hung PVC MIKRON vVWW.CWS.CC 4 H-1836 Alum.Fixed Meet Rail ALUMINUM 13 8 5 S-6063 Fixed Rail Cover PVC MIKRON 6 1 H-6027 lSash Top Rail PVC MIKRON 9 11/16' We* CORNER WELD 81 1 00 PVC 7 1 H-1497 lReinforcement for STIR ALUMINUM KEYMARK L--j 10 IF2 (ALL SIDES) SINGLE HUNG 1:8 1 8 11+6028 ISash Bottom Rail PVC MIKRON IMPACT 9 1 H-1699 lReinforcement for SBR -ALUMINUM KEYMARK PVC FRAME FLANGE-6031 PVC SASH STM.RAIL-6028 PVC;SASH TOP RAIL-6027 I 10 H-6004 Sash Side Rail PVC MIKRON za <.9 11 S-1498 Reinforcement for SSR ALUMINUM KEYMARK j3 0 CQW00 PVC MIKRON W-10 <Lzw 12 S-60634 Glazing Bead W Z0Z W -t 13 P-3118 Keeper,Sweep Lock ZINC SULLIVAN 3 1/8" g :k 2§j>.0 X 3r.5 IL 1-- z�-3:m!E 14 P-3541 #8 x 112",Pan Head,Tek STEEL FASTENAL Z Z=2<wwoo 1 112" C 0 0 6<=I-X 16 P-4632 Sweep Look ZINC SULLIVAN 13116" C 0 �-Z a-P(0 a. 16 P-4633 Barrel Fastener STEEL FASTENAL FIXED MEETING RAIL 0 Z (0-Z I-=)(n 4 SCREWED TOGETHER WITH 00:1 --50- L-2 Z0,4ZOLL0 17 Block&Tackle Balance STEEL CALDWELL IIIS_ OUTERFRAME �--U.�o 0Z Purfect Glaze"Fr or Sikaflex 652 SILICONE HENKEUSIKA 1:8 <':0 W;=� 18 15/8. 2 �r- 1/16' 241-0 ze GLASS 1 CARDINAL 19116* a� U) 19 Sash SEE SHEET 2 00 >-5 U.(0 W 0 W CO LU 20 Fixed SEE SHEET 2 GLASS CARDINAL a. a:0 0) L Z 0-j Ln�- 21 P-3429 Wstp.,0.270 x 0.187 back FinSeal NYLON ULTRAFAB 0 W >- FASTENAL W 2: w3rww 22 P-4638 #8 x 2-1/2 PH Mod.Truss,Type A,TEK 2 STEEL PVC SASH SIDE RAIL-6004 FIXED RAIL-1836 0: IL 23 #10 x 11/2"Panhead SMS STEEL FASTENAL 24 Flat Washer STEEL FASTENAL PVC F IS Hun RAME FIN-6048 I Hun F2 n I 3 H 4 r F 1112. 18 25 IS-6014 Screen Catch PVC MIKRON j 26 IS-6013 Screen Support PVC MIKRON 27 P-4051 #8 x 1 1/4"Ph Fh TEK No 58201 Wht ZINC FASTENAL 15/16- 9/16' 1/8"1 ZINC FASTENAL 28 P-3748 #6 x 0.625"Quad Fh TEK,Wht 1/2' 5116' 04 29 P-3783 Impact Lock STEEL INTERLOCK STATE OF 30 P-4069 Impact Keeper STEEL INTERLOCK 71W 6 15116' 31 P-4264 #8 x 3/4 FH PH w/#6 Head,TEK Wht STEEL FASTENAL iLi-. 1116* 1/16' 32 P-3218 Screen Frame ALUMINUM ALLMETAL Ills" 33 P-3321 Screen Comer Key _ PLASTIC M&M— PVC SASH STOP-6025 PVC SCREEN CATCH-6013 PVC FIXED RAIL COVER-6063 PVC SCREEN SUPPORT-6014 34 P-3228 Screen Spine RUBBER DAPA 36 P-3581 IScreen Cloth VINYL WIER 36 P-3033[Screen Spring - STEEL HURLEY 37 1 P-3029 iScreen Pull Tab STEEL HILIFU-EY 3/4' 3/4' 1 1/4'---1 22/2017 38 1 P-3352 ISet Bk 85 Dur,I/Br x 5/8"x 27 RUBBER FRANK LOW 3116 39 1 P-3768 1#8 x 5/8 Phil Pan Zinc ZINC FASTENAL - 7181: LUCAS�.TURNER,P.E. 4 P-4479 Wee cover PLASTIC M&M 1510(r Fl-PE#58201 0 pill, 12391 ABARA AVE. 41 P-3113 Screw Support RUBBER TEAM NORTH�ORT.Fl-34288 42 P-6025 Sash Stop PVC MIKRON REINF.S.B.P-/S.S.P.-1498 REINF. BTM RAIL-1699 REINF.TOP RAIL-1497 PVC GLAZING BEAD-6064 PH.IA41-380-1574 43 P-3059 Sash Cam PLASTIC M&M SHEET—DESCRPTION: 44 P-3295 Take Out Clip STEEL SUMMIT 46 P-3342 Seam Sealer SILICONE SCHNEE BOMANEXTRUSIONS 4 P-3762 Hole Plug F, M&M 1/2' �c 16 DRAWN BY. DATE: Hung PVC MIKRON 3/16. EXTRUSIONS 2 1 T ADE 06110/08 47 H-6D48 Frame Head,FIN,Single RE 48 1 P-4959 lWstp..0.420 x 0.187 back NYLON ULTRAFAB DWG#: REV.: SCREW SUPPORT-3113 CWS-155 D SCALE: SHEET NOTE:ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. 1:2 40F6 15•MAX.O.C.(TYp.) V""�""" •€,�. 6•MAX."P.) 4•MAX.(TYP.) 8•MAX O.C.(TYP.) WINDOW SYSTEMS 1900 SW 446°MAX.(TYP.)� 4'MAX(TYP.) OCALA,F OTRIDA 34474 - -- -- ANCHOR ATMIDSPAN 4•MAX'(TYP.) 8'MAX.O.C.(TYP.) WWW.CWS.CC (TYP.) 4°MAX(TYP.) 8'MAX(TYP.) I , , 6"MAX(TYP.)- I FF 8100 PVC 8" I I -- -- SINGLE HUNG 14" O MAX O.C. O MAX D.C. (TYP-) II PACT (TYP.) I I - i ; -rZ Mrc Rn� I II 7♦' I I 8- 0 " Om O.C. I� OII � o 1°13 W o�uiO.C. O <w FOZZ(TYP.) O Wr Ri a _ °34"(TYP, LL I- zM=--- MTGRAL 0 Z z= Q fe W O C 4'(TYP.) I X I X O Uy�Za-I=-v~ia 4"(1YP.) I I I y I 0 z _ZHDtn X I I I O X zUt6z:3U— I I OW02OZ Q I a Oo�>-btz LL 2'fn�W(AW W _1 EL _~of W3w> ANCHOR LAYOUT-(FLANGE) ANCHOR LAYOUT-(FIN) ANCHOR LAYOUT-(FLANGE) ANCHOR LAYOUT-(FIN) ix CL F I D- D- SIZES OVER 36•x 62' SIZES OVER 36"x 62' SIZES 36'x 62'AND UNDER SIZES 36"x 62"AND UNDER �JGPy BNSFGpy��. No 58201 t 15 Qt STATE OF ;�4r NOTES: 1.INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION.SILL ANCHOR SPACING SAME AS HEAD. 2.SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX.ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16"IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED. 3.ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 6. 9/22/2017 4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST LUCAS A.TURNER,P.E. BE PROTECTED TO PREVENT REACTION. FL,E#58201 1239 IIABARA AVE. 5.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM NORTH,PORT,FL 34288 SPECIFIED IN TABLE 1,SHEET 6. PH.1941-380-1674 6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE. SHEET DESCRIPTION: INSTALLATIONS TO SOLID CONCRETE OR GROUT-FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND THE SUBSTRATE. ANCHOF�SCHEDULE AND INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. NOTES 7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:3"FOR MASONRY,1"FOR WOOD AND METAL. DRAWN BY: DATE: 8.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. ADE 06/10/08 SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. DWcs: REV.: CWS-115 D 9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: SCALE: FMA/AAMA 100(FIN WINDOWS),FMA/AAMA200(FLANGE WINDOWS), FMAANDMA250(BOX WINDOWS),FMA/AAMANVDMA 300(E)(TERIOR DOORS) SHEET 1:25 5 OF 6 MIN.EMBEDMENT 11 TI/7R9 //n •�/e�/� TYPICAL HEAD ANCHORAGE SEE TABLE 1 SUBSTRATE ��-/(9(f4�U•W/ ,'/�/�I BY OTHERS WINDOW SYSTEMS MIN.EDGE DIST. 1/4'MAX.SHIM SEE TABLE 1 MIN.EDGE DIST. SUBSTRATE SEE TABLE 1 SEE TABLE 1 BY OTHERS 1900 SW 44TH AVE. SEE TABLE 1 OCALA,FLORIDA 34474 1/4'MAX SHIM WWW.CWS.CC SUBSTRATE BY OTHERS I SEE TABLE 1 MIN.EMBEDMENT o MIN.EDGE DIST. PERIMETER SEALANT SEE TABLE 1 SEE TABLE 1 81 UO PVC BY INSTALLER INSTALLATION ANCHOR INSIDEANDOUT SEETBLE1 SINGLE HUNG SEALANT BEHIND SEE TABLE EMBEDMENT IMPACT FLANGE BY INSTALLER 1/4•MAX.SHIM 0 Z � QZ� PERIMETER SEALANT Z W LU O Q W 0 W PERIMETER SEALANT n BY INSTALLER W z O z 0_�Z F- BY INSTALLER Lim INSIDE AND OUT a ;Q LL � Z O 3�2 INSIDE AND OUT INSTALLATION ANCHOR Z z Q INSTALLATION ANCHOR SEALANT BEHIND SEE TABLE 1 0 O N O rj FI-d SEE TABLE 1 FLANGE BY INSTALLER SEALANT BEHIND to z O ZT —Z55— FIN BY INSTALLERo(!):"�Z ` B� ' HORQONTAL SECTION �� HORIZONTAL SECTION —LLM p O LLO �/ TYPICAL JAMB ANCHORAGE 6 TYPICAL FIN ANCHORAGE Q Q O N F-F Z Z HEAD AND SILL SIMILAR FOR FIN INSTALLATION Q 2�00 }j 3 O'6 LL w(A0 W(AW M zJ IL O-rD O WF �"OLL W=0� 1/4°MAX.SHIM d F- I O- W_ IL SEALANT BEHIND FLANGE BY INSTALLER O ,NNituurrr// I , PERIMETER SEALANT BY INSTALLER MIN.EMBEDMENT �C:• V o 58201•••y�� INSIDE AND OUT SEE TABLE 1 SUBSTRATE BY OTHERS--/ 590 •••�iTATE OF :k/� SEE TABLE 1 MIN.EDGE DIST. ���ccs• O Rk�p'•��:� SEE TABLE 1 A VERTICAL SECTION 6 TYPICAL SILL ANCHORAGE TABLE 1:APPROVED INSTALLATION FASTENERS 0 9/22/2017 F ANCHOR TYPE T. LUCAS A.TURNER,P.E. FLANGE CONCRETE(2.0 KSI MIN.) 3/16"ITW TAPCON 1-1/2" 1-1/8° FL PE#58201 PERIMETER SEALANT 1239 JABARA AVE. OR GROUT-FILLED CMU(117 PCF MIN.) 3/16"ITVII TAPCON 1" BY INSTALLER NORTH PORT,FL 34288 FLANGE CONCRETE(2.85 KSI MW.) 6"ELCO ULTRACON 1" 1° INSIDE AND OUT PH.941-380-1574 HORIZONTAL SECTION i FLANGE GROUT-FILLED CMU(ASTM C-90) 3/16"ELCO ULTRACON 1-1/4" 2-11T 6 BOX FRAME INSTALLATION SHEET DESCRIPTION: 3/16"ITW TAPCONHEAD AND SILL SIMILAR FOR BOX INSTALLATION FLANGE 2XMIN.SOUTHERN PINE(G=0.55) OR ELCO ULTRACON 1.3/8" 7/8" INSTAL TION DETAILS FLANGE 2X MIN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1-3/8" 7/8" FLANGE REMOVAL NOTE:PARTIALLY OR FULLY REMOVING THE FLANGE, DRAWN BY: DATE: 16 GAUGE(0.060")MIN.STEEL STUD #10-16 HILTI KWIK-FLEXOR ITW FULL THREAD UP TO AND INCLUDING A BOX-FRAME APPLICATION IS ACCEPTABLE PROVIDED: FLANGE (33 KSI YIELD MW) TEKS SELF-DRILLWG SCREW THRU 0.060" 7/16" ADE 06/10/08 1/8"ALUM.(6063-T5 MIN.) G)OR #10 GRADE 5 SELF-TAPPING/ FULL THREAD -MIN.1/4"FILLET OF CONSTRUCTION-GRADE ADHESIVE CAULK IS APPLIED DW #: REV.: 1/8° FLANGE STEEL(33 KSI MW.) DRILLING SCREW THRU 0.125" 7/16" INSIDE AND OUT,FULL PERIMETER,BY INSTALLER. CWS-1 5 D -PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS FW 2XMW.SOUTHERN PINE(G=0.55) #8 WOOD SCREW 1-1/2" 7/16" SHOWN FOR FLANGE WINDOWS. SSE' SHEET 1:2 6 OF 6 PRODUCT APPROVAL NUMBER: 16177.1 OPENING IDENTIFICATIONS: 5 1/4/2018 Florida Building Code Online rti'r •• 0 . o ' O r 1 BCIS Home Log In I User Registration I Hot Topics Submit Surcharge Stats&Facts Publications �, FBC Staff I BCIS Site Map I Links Search Florida aQProduct Approval p r USER:Public User PEcrrvl— J & 1 V Product Approval Menu>Product.or Anolication Search>Annikation List>Application Detail FEB 01 2019 • �' FL# FL16177-R2 Application Type Revision ST. Lucie County, Permitting Code.Version 2017 Application'Status Approved Comments Archived r mOOD1 m Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenue Ocala, FL 34474 (352)368-6922 Ext 245 kpine@cws.cc Authorized Signature Kevin Pine kpine@cws.cc Technical Representative Jay Lathrop Address/Phone/Email 1900 SW 44th Ave Ocala, FL 34474 (352)368-6922 Ext 291 jlathrop@cws.cc Quality Assurance Representative Arturo Monteverde Address/Phone/Email 1900 SW 44th Ave Ocala,FL 34474 (352)368-6922 Ext 221 amonteverde@cws.cc Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 13 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Lucas A.Turner Evaluation Report Florida License PE-58201 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 07/21/2020 Validated By Steven M. Urich,PE O Validation Checklist-Hardcopy Received Certificate of Independence FL16177 R2 COI EvalReport812C.Rdf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA/101/I.S.2/A440-08 2008 -ASTM E1886-05 2005 ASTM E1996-09 2009 D-A-TAS-201/202/203— 1994 Equivalence of-Product Standards Certified By https://www.floddabuilding.org/pr/pr app dtl.aspx?param=wG,EVXQwtDgvyf4ngAXh10y8QtjDbmBIPrafAGHlxlsggUObEAbzoQ%3da/o3d 1/2 1/4/2018 Florida Building Code Online Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/28/2017 Date Validated 09/29/2017 Date Pending FBC Approval 10/03/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 16177.1 SH-8100 PVC Single Hung SH-8100 PVC Single Hung Impact Resistant window. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16177 R2 II CWS-812C.pdf Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: +70/-70 Evaluation Reports Other:SH-8100 PVC Impact,no sill anchors required.Safety FL16177 R2 AE EvalRenort81217.pdf glazing required on outer lite above 30 ft. in HVHZ. Glass Created by Independent Third Party:Yes complies to ASTM E1300-04. Back Ptext o - Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click here. Product Approval Accepts: �rsr 5w--,i ® eChKk M Credit Card` I Safe i https://www.floddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvyf4ngAXh10y8QtjDbmB[PrafAGHlxlsgtjUObEAbzoQ%3d`/*3d 212 URNER1239 Jabara Ave. North Port,FL 34288 ENGINEERING & Ph. 941-380-1574 TCONSULTING, INC. FBPE C.O.A. #29779 Evaluation Report 812C August 29,2017 Product Description: Series 8100 PVC Single Hung,Large Missile Impact, 517/8"x 613/4"unit size, +/-70 PSF,no anchors in sill Manufacturer: Custom Window Systems, Inc. 1900 SW 44 h Ave, Ocala,FL 34474 Statement of Compliance: This report evaluates the above-listed product per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the requirements of the 6`h Edition(2017)Florida Building Code including the High Velocity Hurricane Zone. The product testing standards performed are outlined below. Technical Documentation: 1) This report,prepared by Lucas A.Turner,P.E.,at 1239 Jabara Ave.,North Port,FL 2) Approval drawing CWS-812C, signed and sealed by Lucas A. Turner, P.E. 3) Test Report NCTL-210-3815-1A, -2, and-2A,by National Certified Testing Laboratories, Orlando, FL, signed and sealed by Gerard J.Ferrara,with testing performed: TAS 201/202/203- 94,ASTM E 1886-02/04/05, 1996-02/04/06/09,and AAMA/WDMA/CSA 101/I.S.2/A440-08 4) Supplemental Calculations to support CWS-812C, signed and sealed by Lucas A. Turner, P.E. Installation: Units must be installed according to approval document CWS-812C. Limitations of Use: This product: • May be used in O/X configuration in sizes and with max. glass DLO heights as shown in CWS- 812C • Is impact resistant and does not require the use of shutters • May be used in the High Velocity Hurricane Zone • Requires 7/8"Insulating Glass consisting of 1/8 Annealed or Tempered outboard lite(Tempered required above 30 ft in HVHZ) —Air—5/16 Laminated(1/8Ann-.090PVB-1/8Ann)inboard lite • Requires Kuraray(Dupont)PVB Interlayer per Miami-Dade N.O.A. 16-1117.021 • Requires Quanex(Mikron)white rigid PVC framing per Miami-Dade N.O.A. 17-0206.101 1 I have evaluated the materials in these NOAs and find that they comply with the requirements of the Oh Ed. (2017)Florida Building Code for use in this product. Certification of Independence: I do not have,nor do I intend to acquire,nor will I acquire, a financial . interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have,nor do I intend to acquire,nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. Lucas = No 58201 *� *� Turner .. �+ *- � Z� 2017-08-30 STATE of r.4u 16:11+20:00 '►,, •.,fi �,,:`��= 8/29/2017 �'•w:;,R �•'`C��.`�—L-ucas-A�' er—P—E. ON 1.z FL PE#58201 irr1R[ri�I SINGLE HUNG - LARGE MISSILE IMPACT GENERAL NOTES: 1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED WIND�Oy SYSTEMS TO COMPLY WITH THE FLORIDA BUILDING CODE(FBC),CURRENT EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVHZ)AND 1900 SW 44TH AVE. IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED OCALA,FLORIDA 34474 IN ASTM E 1996 PER THE FBC. WWW.CW .CC 2.GLAZING OPTIONS:(SEE SHEET 2) 53 1/8°MAX OVERALL FLANGE WIDTH 3.CONFIGURATIONS:°ODC. 81100 PVC 517/8"MAX UNIT WIDTH SINGLE HUNG 4.DESIGN PRESSURE RATING: 4711/16°GLASS DLO -NEGATIVE DESIGN LOADS BASED ON,TESTED PRESSURE AND ITPA'CT GLASS TABLES ASTM E-1300-04e01/09. A -POSITIVE DESIGN LOADS BASED ON,TESTED PRESSURE,WATER INFILTRATION TEST PRESSURE AND GLASS TABLES ;� z _O <W p -- -- -- ASTM E-1300-04e01/09. Z W ❑ ¢ o w w zOz 63° _ __ I 5.ANCHORAGE:THE 331/3%STRESS INCREASE HAS NOT BEEN USED � F W Z}O 3= MAX IN THE DESIGN OF THIS PRODUCT.SEE SHEET 6 FOR ANCHOR Z Z x 2¢K OVERALL I I DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD O O F;O�j¢F�w FLANGE ANCHOR CALCULATIONS. U O 4�Z ajL HEIGHT O z 0 0D --m U- B I B 2613/16" 6.PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE ¢ -z o v)zz O u Z I DLO NOT REQUIRED. -ow-mo- 9 -I I 7.ALL FRAMES AND VENTS FULLY WELDED.SMALL JOINT SEAM SEALANT 00 y O w y w 613/4. I I USED AT FIXED MEETING RAIL AND JAMB. Z y a OUNIT1 to I- MAX D x a. >_ G HE HT S.SERIES/MODEL DESIGNATION SH-8100. ix 2 i k%w CL CC 9.THE DESIGNATION XAND O STAND FOR THE FOLLOWING: X=OPERABLE SASH,O=FIXED SASH 303/16' I I � �CEIV$'•G��� MAX 26 7/8• 10.SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR '�G:�, F•.•Z�' SASH I GLASS LOCATION. t� No 58201 -A r HEIGHT X I DLO S* .* B 11.EXTERNAL W EEP SLOT=1/4"x 1-1/4'LOCATED 4'FROM BOTH ENDS. C O' $TATE OF :mow I 4 I 6 i�iTl •F� R1�A•�a�� LI I 'l,�SS70NALEN���. LucasTurne s A r 451/16' 2017-09-22 Z� GLASS DLO 13:36-04:00 48 3/8" 9/22/2017 MAX SASH WIDTH LLICASk TURNER,P.E. FL pE#58201 123911ABARA AVE. NORTH PORT,FL 34288 PH."1-380-1574 SHEET DESCRPTION: GENERAL NOTES AND TABLE OF CONTENTS EL NATIONS DRAWN BY: I DATE: GENERAL NOTES&ELEVATIONS.....1 DESIGN PRESSURE BAT 06/18/12 GLAZING DETAIL.................................2 MAX. UNIT SIZE IMPACT RATING SECTION VIEWS.................................3 RATING Dwcn: REV.: EXTRUSIONS&B.O.M........................4 CWS-812 C ANCHOR SCHEDULE&NOTES.........5 51-7/8"x61-3/4" +/-70 PSF LARGE MISSILE IMPACT INSTALLATION DETAILS....................6 SCALE: SHEET 1:15 1 OF 6 C� ®rte' WINDOVI SYSTEMS 1900 SW 44TH AVE. OCALA,FLORIDA 34474 W W W.CWS.CC 8100 PVC SINGLE HUNG ITPACT 0w0 mwoo w z0z mk t aa?�.73 0Xm 7/8.OVERALL INSULATED GLASS 7/8.OVERALL INSULATED GLASS z z z 2 4w W 0 O 1/8•ANNEALED OR TEMPERED 1/8°ANNEALED OR TEMPERED 0 0 4 r z iL z cn jL �UW 7/16'AIRSPACE 7/16°AIRSPACE Q O Z LLM O O LL Z 5/16°LAMINATED GLASS 5/16'LAMINATED GLASS 9 0 H U I_z uj 1/8'ANNEALED 1/8'ANNEALED W 00 ai a Lu(n w ir ZM,W OJlgh .090'PVB INTERLAYER BY DUPONT090°PVB INTERLAYER BY DUPONT a0 w X O W 0 1/8•ANNEALED 1/8'ANNEALED a ►_- a w�'a OUANEXDURASEALOUANEXDURASEAL IG SPACER p►nmr 47 PURFECT GLAZE W OR SIKAFLEX 552 4 URFECT GLAZE'H'OR SIKAFLEX 552 �0�,,,►►.D�w'T(����� +-' No 58201 14 1/2'GLASS BITE 14 1/2'GLASS BRE 48J 8 g3 16ot STATE OF •;cwt 1 1 ONA + , 0 FIXED LITE SASH LITE 9/22/2017 LUCAS A.TURNER,P.E. FL PE#58201 1239 ABARA AVE. NORTH PORT.FL 34288 1 PH. 1-380-1574 SHEET DESCI PTION: GLAZ NG DETAILS i DRAWN BY: DATE: BAT 06/18/12 DWG N: REV.: CWS-812 C SETTING BLOCKS PER FBC 2411.3.3.1 scALE: SHEET 1:1 2 OF 6 '' I INTERIOR WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA,FLORIDA 34474 W W W.CWS.CC 45 3 53 1 38 13 3 3 4 5 1 81,00 PVC 0 1 SINGLE HUNG o IMPACT as p p 3 `Z o �w o ' Z WWoO a�Zw 14 3 0 a HW�ZZO��= Z Z.3; WWOO 3 14 54 14 6 66 63 19 4 O 0 Ft 0 Q=F.X SECTION B-B p Z �ZZF�� NOTE:LEFT SIDE SHOWS FIXED SECTION VIEW, g Z O C Z O 0- RIGHT SIDE SHOWS SASH SECTION VIEW. ~ p w of Z >w a- w—€O- 03Zc w_ 0 (0awmw 14 39 a0 W=0 (L 4Ir 0 a H Dom. w�a0 6 1 3 INTERIOR P$`5 PO�w 48 Z—: No 58201 •.-A 62 •FTATE OF ;�kr` s.<ORtOP����� 14 59 '";"10 riu 65 10 66 yy 6 3 F� 3 3 18 9/22/2017 6 LUCAS A.TURNER,P.E. 2 4 FL FE#58201 3 30 1239 4ABARAAVE. o NORTH PORT,FL 34288 PH. 1-380-1574 SHEET DESIPTION: SECTION A-A SECTION VIEWS DRAWN BY: DATE: BAT 06/18/12 DWG#: REV.: NOTE: ITEMS NOT SHOWN FOR CLARITY: CWS-812 C 20.25-26.36-37,44.51-52,55-56,64,67-68 SQALE: SHEET 1:2 30F6 U PARTS LIST FRAME CORNER //� DEM PARIDESCRIPTION VENDOR MATERIAL 31/g°� CONSTRUCTION (/ wg�®m' 1 H30311 Main Fr.,SH,w/Flg.,PVC,Head Mikron VinylV- 2 H-6031 Main Fr.,SH,w/Flg.,PVC,Sill Mikron Vinyl 1 15/16°--i WINDOW SYSTEMS 3 H-6031 Main Fr.,SH,w/Fig.,PVC,L.Jb. Mikron Vinyl 1 I �--2 3/16• 1900 SW 4TH AVE. 2 I OCALA,FLORIDA 34474 4 H3031 Main Fr.,SH,w/Flg.,PVC,R Jb. Mikron Vinyl � � 6 S-1577 Impact Hook Keymark Alum 3 10 a WWW.CWS.CC 8 H-6027 Sash Meet.Rail,PVC Mikron Vinyl 211/16• 4 1 5/a° q 1 5/8• 9 H-1497 Reinf.Sash Meet.Rail Keymark Alum 1/16" 1/16° 8100 PVC 10 H-6028 Sash Bottom Rail,PVC Mikron Vinyl 0 L (ALL SIDES) SINGLE HUNG 1/16• CORNER WELD 12 H3004 Sash Side/Top/Bot.Rail Mikron Vinyl 1;8 13 S-1498 Reinf.S.B.R./S.S.R IMPACT 14 S-6064 Glz.Bd.,7/8" Mikron Vinyl PVC FRAME FLANGE-6031 PVC SASH BTM.RAIL-6028 PVC SASH TOP RAIL-6027 18 53013 Scm.Adapt.,w/Nib,PVC,Horiz. Mikron Vinyl ¢ z ¢z 19 S-6014 Scm.Adapt.,PVC,Vert. Mikron Vinyl m O 20 S-6029 Sash Stop/Filler,PVC,Vert. Mikron Vinyl 1 1/2" 37 z w-j o ¢�z w 13/16" w zOz_ K--C Q� } �- 23 H-1699 Reinforcement,SBR Keymark Alum 7/8° ❑ O tr m 24 P-2190 Balance BSI 9/16. U.1 1 Z Z z a W O E 25 P-3059 Sash 26 P3046 Take Out I PVC BSI BSI PISSIc -06, 1 5/a° 21/8° 1/16• ❑ Z 111 11 0 ~O O a.a. ?a. FIXED MEETING RAIL t!1? 27 P-3783 Lock,Impact,PVC Interlock SCREWED TOGETHER WRH Z O Z U vj z U- 28 P-4069 Keeper,Impact,PVC Interlock Zamac 1/16° OUTERFRAME ¢ i---u_20 O tL Z REINF.,IMPACT HOOK-1112 1'a 3 O Fw-F- O- fi 30 P3215 Weep Cooerw/Flap Gaer Plastic 32 P3429 Wstp.,0.270 x.187 back FinSeal,Gray Ultrafab PVC SASH SIDE RAIL-6004 FIXED RAIL-1836 w Op 4 w O w rn w 37 P-4638 #8 x 2-1/2 PH Mod.Truss,Type A,TEK 2 Fastenal Steel of Z. wa O-1 m 1-38 P3768 #8 x 0.625 Ph PH SMS Hub City Steel 1 5/16° 9116• O w Fzr O a= > 39 P-4051W#8 x 1.250 Ph FH TEK,Wht. Hub City Steel 112" 1 1/8.1 T �'1 y a. � I UL of 3 wa� 40 P-4264W#8 x 3/4 FH PH w/#6 Head,TEK,Wht. Hub City Steel o 1 Sl16-111 44 P3342 Seam Sealer,SM-5504 Schnee 7/8" 18 1 5/16" 45 P3752 Cap Plug,1/2"Hole M&M Nylon 1/16• 045' 1/16• �•� 5••°CEN•. 47 P3438 Sikaflex 552 or Purfect Glaze°H" Sika/Henkel 1/16" A GP:vn S4$' 48 P3352 Set.Blk.,85 Dur.,1/8"x 5/8"x 2"Lg. F.Lowe Rubber PVC SASH STOP-6025 PVC SCREEN CATCH-6013 PVC FOXED RAIL COVER-6063 PVC SCREEN SUPPORT-6014 �; f�o 58201 •.�� 51 P3881 Temporary Lbl.(NFRC/DP) 52 P3613 CWS Lbl.(logo) Pro Label 3/4" 5/e° * 53 Sash SEE SHEET GLASS 314• 1l4•�1 I- ��: STATE OF .W� 54 Fixed SEE SHEET2 GLASS 3/16• —^ 3 14 %O,P'Q 56 P3281 Spacer Duraseal a 1/1 s• F' IpNq E ►� ` 13 15/16• 1' 9 7/8' i��SS'•....... CVOP� 62 P3218 Screen Frame,Horiz. Allmetal Alum � 1116 j— 1/16 63 P3218 Screen Frame,Vert. Allmetal Alum REINF.S.B.RJS.S.R.-1498 REINF. BTM RAIL-1699 REINF.TOP RAIL-1497 PVC GLAZING BEAD-6064 64 P3321 Screen Frame Comer Key Allmetal Plastic 65 P3581 Screen Cloth,18 x 16 Fiberglass Betterwe Fiberglass 66 P3228 Screen Spline,.155 Dia.,Blk. Dapa Vinyl i r 67 P3029 Screen Pull Tab Summit Alum 68 P3033 Screen Spring,SS FI.Screen SS 9,/22/2017 70 P3113 Screw Support for PVC T.Plastics I Nylon LUCAS A.TURNER,P.E. 71 H-1836 Alum.Fixed Rail Keymark Alum 0 3/16° FL rE#58201 72 S-6063 Coker,Fixed Rail Mikron Vinyl O 1239 UA13ARAAVE. 73 8-1112 Reinforcement,Impact Hook jaymark Alum NORTH PORT,FL 34288 74 P3541 #8 x 1/2",Pan Head,TEK astenal Steel PH.941-380-1574 1 5/16° 1/2• SHEET DESCRIPTION: LINE ITEMS NOT USED: 5" 3/167, 1- 1 5,7,11,15-17,21-22,29,31,33-36,41-43,46,49-50,55,57-61,69 6 -3• -1 BOM ANp EXTRUSIONS 7/8• 1116° o SCREW SUPPORT-3113 DRAWN BY: DATE: IMPACT HOOK BAT 06/18/12 S-1577 DWG#. REV.: CWS-812 C NOTE:ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. SCALE: SHEET 1:2 4 OF 6 ®M� WIN 6•MAX.(TYP.) 17°MAX.O.C.(fYP.) DO SYSYEWIS 1900 SW 44TH AVE. 6°MAX(TYP.) OCALA,FLORIDA 34474 -- -- -- WWW.CWS.CC I I I SEE NOTE 2 101/2• , , 81,00 PVC MAX O.C. SINGLE HUNG (TyP-) IMPACT �— O INSTALLATION ANCHOR(TYP.) _ 13 <zg I I F ❑WO p W z0? W-I= o ; rW�>-Ox3:m /` a I-ui zF��x __-LMTGRAL z U fx m< W O O 4° (1YP.)-J I ' O Z�VJ z Z�"N I I SOC Z 2 X MAX O.C. W LLd'(n�w w (TYP) I I Q WHO d0�w I I LL H d a0 puu�ggl (TYP.) `���` DREW 4° P. -- -- -- ;JGQ�?.•'C E fV SF Gptiyl' 4'(TYP•) NO ANCHORS REQUIRED IN SILL v' 0 58201 ANCHORLAYOUT-(FLANGE) '°O= cxe X90; ,$TATE OF •;k/k�� NOTES: 1.INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION.NO ANCHORS REQUIRED IN SILL. 2.SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX.ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16"IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED. �Z 3.ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 6. 9/22/2017 4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST LUCAS A.TURNER,P.E. BE PROTECTED TO PREVENT REACTION. FL PE#58201 1239 IIABARA AVE. 5.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM NORTH PORT,FL 34288 SPECIFIED IN TABLE 1,SHEET 6. PH.941-380-1574 6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE. SHEET DESC i PTION: INSTALLATIONS TO SOLID CONCRETE OR GROUT-FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND THE SUBSTRATE. ANCHOR SCHEDULE AND INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. ,VOTES 7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:3"FOR MASONRY,1"FOR WOOD AND METAL. DRAWN BY: DATE: 8.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. BAT 06/18/12 SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. DWG#: REV.: CWS-81 C 9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: SCALE: SHEET FMA/AAMA100(FINWINDOWS),FMA/AAMA200(FLANGEWINDOWS), FMANVDMA250(BOXWINDOWS),FMA/AAMANVDMA300(EXTERIORDOORS) 1:15 5OF6 • TYPICAL HEAD ANCHORAGE ® • MIN.EMBEDMENT WINDO SYSTEPIS MIN.EDGE DIST. SEE TABLE 1 SUBSTRATE SEE TABLE 1BY OTHERS 1900 SW 44TH AVE. 1/4"MAX SHIM SEE TABLE 1 OCALA,FLORIDA 34474 SUBSTRATE BY OTHERS WWW.CW .CC SEEEE TABLE 1 MIN.EMBEDMENT PERIMETER SEALANT SEE TABLE 1 MW.EDGE SEE TABLE 1 DIST. 81 OO PVC BY INSTALLER INSIDE AND OUT INSTALLATIOSINGLE HUNG SEALANT BEHIND SEETABLE1 ANCHOR IMPACT, FLANGE BY INSTALLER 1/4'MAX SHIM Z f3: 3 aZO H ❑ILO cowFpw W ZJOZ W=f::t= O Roq >-OIr3m PERIMETER SEALANT LL F-w Z F-�i g 2 BY INSTALLER Z Z 2 m a cew O O INSTALLATION ANCHOR INSIDE AND OUT U 0.2 1--Z a H U)D_ SEE TABLE 1 SEALANT BEHIND O Z Z H�y BY INSTALLER Q 0(-g--3 Z O Co Z­55— FLANGE U CONTINUOUS DOUBLE 3/16"BEADS OF / of HORIZONTAL SECTION Q V C Z cj TREMGLAZE U1600 SEALANT AROUND 6 TYPICAL JAMB ANCHORAGEW O O �=O W Q W PERIMETER AT ALL INDICATED POINTS Z N w BETWEEN FRAME AND BUCK BY INSTALLER p W F a.O d 2 >' d ww� 1/4'MAX SHIM a I a SEALANT BEHIND FLANGE BY INSTALLER µuu q PERIMETER SEALANT Ci-1 G E N S41 GQWG 11 BY INSTALLER MIN.EMBEDMENT ��'� 0 58201 °'%'. INSIDE AND OUT SEE TABLE 1 S-0. eCC SUBSTRATE BY OTHERS :0'� ATE OF :mak/' SEE i TABLE 1 MIN.EDGE DIST. TABLE I ����4ji ON / A� VERTICAL SECTION TAL-�p�` �hOuf\4t1 6 TYPICAL SILL ANCHORAGE 9/22/2017 TABLE 1:APPROVED INSIALLATION FASTENERS LUCAS A.TURNER,P.E. ANCHOR TYPE MIN.EMBEDME FL PE#58201 CONCRETE(2.0 KSI MW.) 3/16°ITW TAPCON 1-1/2" 1-1/8" BYRINSTTAL ERER CT NORTH PORT,FL 34 HOLLO INSIDE AND OUT NORTH PORT,-1 34288 ° PH.941-380-1574 C HORIZONTAL SECTION i CONCRETE(2.85 KSI MIN.) 3/16"ELCO ULTRACON 1" 1" 6 BOX FRAME INSTALLATION SHEET DESCRPTION: GROUT-FILLED CMU(ASTM C-90) 3/16"ELCO ULTRACON 1-1/4" 2-1/2" HEAD AND SILL SIMILAR FOR BOX INSTALLATION 2XMIN.SOUTHERN PINE(G=0.55) 13/8" 3/16"ITW TAPCON 7/8" INSTALLATION DETAILS OR ELCO ULTRACON FLANGE REMOVAL NOTE:PARTIALLY OR FULLY REMOVING THE FLANGE, 2X MIN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1-3/8" 7/8" UP TO AND INCLUDING A BOX-FRAME APPLICATION IS ACCEPTABLE PROVIDED: DRAWN BY: DATE: 16 GAUGE(0.060')MW.STEEL STUD #10-16 HILTI KWIC-FLEXOR ITW FULL THREAD BAT 06/18/12 (33 KSI YIELD MIN) TEKS SELF-DRILLING SCREW THRU 0.060" 7/16" MIN.1/4"FILLET OF CONSTRUCTION-GRADE ADHESIVE CAULK IS APPLIED DWG M REV.: INSIDE AND OUT,FULL PERIMETER,BY INSTALLER. CWS-81'2 C 1/8"ALUM.( T5 MIN.)OR #10 GRADE 5 SELF-TAPPING/ FULL THREAD 7/16" -PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS 1/8"STEEL(33 33 K KSI MIN.) DRILLING SCREW THRU 0.125" SHOWN FOR FLANGE WINDOWS. SCALE: SHEET 1:2 6 OF 6 •