Property InformationBuilding Information
Owner: Steen I Wind Zone: 160 MPH.
Address: 1708 Angle Rd - 1 Exposure Category: B
Ft Pierce,Fl 34947 Minimum Building Dimension: 24 ft.
Mean Roof Height: 15 ft.
Risk Category: II I
I
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 53 50 7 31.2 -33.9
2 Int 53 50 7 31.2 -33.9
3............ Int 37 50 7 32.0 -34.7
4 Int 37 50 7 32.0 -34.7 •
5 Int 37 50 7 32.0 -34.7
.
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.