Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval-Exterior Door
Florida Building Code Online \ c\0 Page 1 of 3 ass �€i R .?, ',s ATM .v.. r&.Asit,,:rii';. 4 ':.:L;erA. R rr . BCIS Home j Log In User Registration I Hot Topics I Submit Surcharge 3 Stats&Facts I Publications ' Contact Us BCIS Site Map i Links Search I F!Q,'iGd - krda tProduct Approval ti IntUSER.Public User x xM RECEIVED product Approval Menu>Product or Application Search>Application List>Application Detail FEB 0 5 2019 FL# FL22513-R2 Application Type Revision Permitting P8partment Code Version 2017 St.Lucie County Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived 0 Product Manufacturer Masonite International Address/Phone/Email 1955 Powis Road West Chicago,IL 60185 (800)663-3667 sschreiber@masonite.com Authorized Signature Steve Schreiber sschreiber@masonite.com Technical Representative Address/Phone/Email Quality Assurance Representative ao Address/Phone/Email Si 1 Category Exterior Doors C.) Subcategory Swinging Exterior Door Assemblies MI Compliance Method Certification Mark or Listingnzi � Certification Agency National Accreditation&Management Institute LL Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By i Product Approval Method Method 1 Option A Date Submitted 04/16/2018 Date Validated 04/18/2018 Date Pending FBC Approval Date Approved 04/24/2018 1 1 I . 1 https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtdytNblepz46QE0w0... 2/5/2019 I L ' Florida Building Code Online Page 2 of 3 Summary of Products FL# Model,Number or Name Description 22513.1 HPC Wood-edge Steel Side-Hinged 6'-8"Glazed I/S or 0/S Single or Double Door w/or w/o Door Unit Sidelites Limits of Use Certification Agency Certificate Approved,for use in HVHZ:Yes FL22513 R2 C CAC N1013747.01-R1.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 06/30/2021 Design Pressure: +50/-50 Installation Instructions Other:Evaluated for use in locations adhering to the Florida FL22513 R2 II FL0212.pdf Building Code,including the High Velocity Hurricane Zone, Verified By: National Accreditation&Management Institute' and where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 6'-8"max nominal size.When Evaluation Reports impact resistance is required,hurricane protective system Is FL22513 R2 AE 514008.pdf required.Door top rails stamped"HPC".See DWG-MA-FL0212 Created by Independent Third Party:Yes for details. 22513.2 Wood-edge Steel Side-Hinged Door 8'-0"Opaque I/S or 0/S Single Door Unit Unit Limits of Use Certification Agency Certificate Approved for use In HVHZ:Yes FL22513 R2 C CAC NI013747.04.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2021 Design Pressure: +70/-70 Installation Instructions Other:Evaluated for use in locations adhering to the Florida FL22513 R2 II FL0215.pdf Building Code,including the High Velocity Hurricane Zone, Verified By: National Accreditation&Management Institute' and where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed.3'-0"x 8'-0"max nominal size.When impact Evaluation Reports resistance is required,hurricane protective system not FL22513 R2 AE 514009.pdf required.See DWG-MA-FL0215 for details. Created by Independent Third Party:Yes 22513.3 Wood-edge Steel Side-Hinged Door 8'-0"Opaque I/S Single or Double Door w/or w/o Sidelites 1 Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R2 C CAC NI013747.04.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2021 Design Pressure: +45/-50 Installation Instructions Other:Evaluated for use in locations adhering to the Florida FL22513 R2 II FL0215.pdf Building Code,including the High Velocity Hurricane Zone, Verified By: National Accreditation&Management Institute and where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 8'-0"max nominal size.When Evaluation Reports impact resistance is required,hurricane protective system not FL22513 R2 AE 514007.pdf required on opaque panels,but is required on glazed Created by Independent Third Party:Yes sidelites.See DWG-MA-FL0215 for details. 22513.4 Wood-edge Steel Side-Hinged Door 8'-0"Opaque 0/S Single or Double Door w/or w/o Sidelites Unit Limits of Use Certification Agency Certificate Approved for use In HVHZ:Yes FL22513 R2 C CAC NI013747.04.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2021 Design Pressure:+50/-45 Installation Instructions Other:Evaluated for use in locations adhering to the Florida FL22513 R2 II FL0215.pdf Building Code,including the High Velocity Hurricane Zone, Verified By: National Accreditation&Management Institute and where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 8'-0"max nominal size.When Evaluation Reports impact resistance is required,hurricane protective system not FL22513 R2 AE 514007.pdf required on opaque panels,but is required on glazed Created by Independent Third Party:Yes sidelites.See DWG-MA-FL0215 for details. 22513.5 Wood-edge Steel Side-Hinged Door 8'-0"3/4-Lite Glazed I/S or 0/S Single or Double Door w/or Unit w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R2 C CAC NI013747.06.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 06/30/2021 Design Pressure:+40/-40 Installation Instructions Other:Evaluated for use in locations adhering to the Florida FL22513 R2 II FLO217.pdf Building Code,including the High Velocity Hurricane Zone, Verified By: National Accreditation&Management Institute and where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 8'-0"max nominal size.When Evaluation Reports Impact resistance is required,hurricane protective system is FL22513 R2 AE 514007.pdf required.See DWG-MA-FL0217 for details. Created by Independent Third Party:Yes 22513.6 Wood-edge Steel Side-Hinged Door 6'-8"Opaque I/S or 0/S Single Door Unit https://floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtdytNblepz46QE0w0... 2/5/2019 Florida Building Code Online Page 3 of 3 Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R2 C CAC NI013747-R1.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2021 Design Pressure:+70/-70 Installation Instructions Other:Evaluated for use in locations adhering to the Florida FL22513 R2 II FLO211.pdf Building Code,including the High Velocity Hurricane Zone, Verified By: National Accreditation&Management Institute and where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed.3'-0"x 6'-8"max nominal size.When impact Evaluation Reports resistance is required,hurricane protective system not FL22513 R2 AE 514010.pdf required.See DWG-MA-FLO211 for details. Created by Independent Third Party:Yes 22513.7 Wood-edge Steel Side-Hinged Door 6'-8"Opaque I/S or 0/S Single or Double Door w/or w/o Unit Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R2 C CAC N1013747-R1.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2021 Design Pressure:+55/-55 Installation Instructions Other:Evaluated for use in locations adhering to the Florida FL22513 R2 II FLO211.pdf Building Code,including the High Velocity Hurricane Zone, Verified By: National Accreditation&Management Institute and where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 6'-8"max nominal size.When Evaluation Reports Impact resistance is required,hurricane protective system not FL22513 R2 AE 514008.ndf required on opaque panels,but is required on glazed Created by Independent Third Party:Yes sidelites.See DWG-MA-FLO211 for details. 22513.8 Wood-edge Steel Side-Hinged Door 6'-8"3/4-Lite Glazed I/S or 0/S Single or Double Door w/o Unit w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 R2 C CAC N1013747.03-R1.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 06/30/2021 Design Pressure:+50/-50 Installation Instructions Other:Evaluated for use in locations adhering to the Florida FL22513 R2 II FL0214.pdf Building Code,including the High Velocity Hurricane Zone, Verified By: National Accreditation&Management Institute and where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 6'-8"max nominal size.When Evaluation Reports impact resistance is required,hurricane protective system is FL22513 R2 AE 514008.pdf required.See DWG-MA-FL0214 for details. Created by Independent Third Party:Yes CEO Ell1 Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Coovrlaht 2007-2013 State of Florida ::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click ere. Product Approval Accepts: MiCHMIEli Credit Card Safe secur tymETRIcs- https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtdytNblepz46QE0w0... 2/5/2019 I.- NOTICE OF PRODUCT CERTIFICATION >x • Company: Masonite International Corporation Certification No.: NI013747-R1 )1t- , ' ,, 1955 Powis Road Certification Date: 06/08/2017 _ West Chicago, IL 60185 Expiration Date: 06/30/2021 t ' Revision Date: 04/13/2018 ; - Product: Wood-Edge Steel Opaque Inswing or Outswing Door w/Non-Impact Rated Sidelites = - _,. '. (w/Wood Frame unless noted) '` Specification: TAS 201/202/203-94 Impact: Large Missile Impact Rated Non-Impact Glazing: Insulating Glass(Tempered) - —The"Notice of-Product Certification"is only valid if the NAMI Certification Label has been applied to the product as described within this document.—The certification label represents product conformity to the applicable specification and that all certification criteria has been satisfied. This product has been approved for listing within NAMI's Certified Product Listing at www.Narnicertification.com. NAMI's Certification Program is accredited by The American National Standards Institute(ANSI). Inswing Glazed Structural Water Missile Test Report Number Configuration or or Maximum Design Test Impact Drawing Number& Outswing Opaque Size Pressure Pressure Rated Comments X 1/S Opaque 3'0"x 6'8" +70/-70 0.0 psf Yes ATLNC 1001.01-13 Single Maximum Panel Size:3'0"x 6'8" Anchor Details-DWG-MA-F.1_0211-17 X 0/S Opaque 3'0"x 6'8" +70/-70 3.0 psf' Yes ATLNC 1001.01-13/W-1857 Single 4.5 psf' Maximum Panel Size:3'0"x 6'8" 7.50 psf'"` Anchor Details-DWG-MA-FLO211-17 XX 1/S Opaque 6'0"x 6'8" +55/-55 0 psf Yes NCTL-210-2930-1 Double Maximum Panel Size:3'0"x 6'8" Anchor Delai ls-DWG-M A-F LO211-17 XX 0/S Opaque 6'0"x 6'8" +55/-55 3.0 psf' Yes NCTL-210-2930-1 Double 4.5 psf' Maximum Panel Size:3'0"x 6'8" 7.50 psf Anchor Details-DWG-MA-FLO211-17 XO/OX 1/S Opaque Door 6'0"x 6'8" +55/-55 0 psf Door-Yes NCTL-210-2930-1 Single w/Sidelite Glazed Sidelite Sidelite-No Maximum Panel Size:3'0"x 6'8"/Sidelite:3'0"x 6'8" Anchor Details-DWG-MA-FLO211-17 XO/OX 0/S Opaque Door 6'0"x 6'8" +55/-55 3.0 psf' Door-Yes NCTL-210-2930-1 Single w/Sidelite Glazed Sidelite 4.5 psf' Sidelite-No Maximum Panel Size:3'0"x 6'8"/Sidelite:3'0"x 6'8" 7.50 psf' Anchor Details-DWG-MA-FLO211-17 OXO I/S Opaque Door 9'0"x 6'8" +55/-55 0 psf Door-Yes NCTL-210-2930-1 Single w/Sidelites Glazed Sidelite Sidelites-No Maximum Panel Size:3'0-x 6'8"!Sidelite:3'0"x 6'8" Anchor Details-DWG-MA-FLO211-17 OXO 0/S Opaque Door 9'0"x 6'8" +55/-55 3.0 psf' Door-Yes NCTL..-210-2930-1 Single w/Sidelites Glazed Sidelite 4.5 psf' Sidelites-No Maximum Panel Size:3'0"x 6'8"/Sidelite:3'0"x 6'8" 7.50 psf' Anchor Details-DWG-MA-FLO211-17 OXXO I/S Opaque Door 12'4"x 6'8" +55/-55 0 psf Door-Yes NCTL-210-2930-1 Double w/Sidelites Glazed Sidelite Sidelites-No Maximum Panel Size:3'0"x 6'8"iSidelite:3'0"x 6'8" Anchor Details-DWG-MA-FLO211-17 OXXO 0/S Opaque Door 12'4"x 6'8" +55/-55 3.0 psf' Door-Yes NCTL-210-2930-1 Double w/Sidelites Glazed Sidelite 4.5 psf' Sidelites-No Maximum Panel Size:3'0"x 6'8"/Sidelite:3'0"x 6'8" 7.50 psf' Anchor Details-DWG-MA-FLO211-17 1-Denotes Bumper Outswing Threshold 2-Denotes 7 Series Outswing Threshold 3-Hi-Dam Outswing Threshold 4-Pro T4 Threshold 5-HP Outswing Threshold National Accreditation & Management Institute,Inc./4794 George Washington Memorial Highway/Hayes,VA 23072 Tel: (804)684-5124/Fax:-(804)-684-5122— ---- _ - - NAMI AUTHORIZED SIGNATURE: ->edia 10 hI MASONITE. 149"MAX. OVERALL FRAME WIDTH O { WOOD-EDGE STEEL DOOR UNIT 21 MAX 36.375" Max. V Q O D.L.O.-- PANEL WIDTH-1 r 37.5" MAX rt Q O 6'-8"DOUBLE DOOR WITH/WITHOUT SIDELITES , W/ASTRAGAL FRAME WIDTH 0 O LL t ti Q.ENERaL NOTES CO> I •1. EVALUATED FOR USE IN LOCATIONS ADHERING TO 1' , D s.--..., l - W Q r THE FLORIDA BUILDING CODE AND WHERE PRESSURE J CLO REQUIREMENTS-AS-DETERMINED BY ASCE 7, MINIMUM _ DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, -- DOES NOT EXCEED THE DESIGN PRESSURES LISTED. r, P ... 0)f- 2. HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS NOT REQUIRED ON 10 N.''' w OPAQUE PANELS, BUT IS REQUIRED ON GLAZED SIDELITES. - - a; .3. WHEN INSTALLED IN THE WIND-BORNE DEBRIS REGION, N ¢x¢ EXCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ), g HURRICANE PROTECTIVE SYSTEM IS NOT REQUIRED ON OPAQUE x M" G PANELS OR PANELS WITH IMPACT GLASS, BUT IS REQUIRED . . ,. ON PANELS WITH NON-IMPACT GLASS. g 0 ? 4. POLYURETHANE CORE FLAME SPREAD OF 50 . � ,. . , a INDEX AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84. L x 5. PLASTICS TESTING: TEST DESCRIPTION DESIGNATION UTE FRAME k 1 g§r ' SELF...IGNITION TEMP ASTM D1929 842 .> 650 'F.. t J 'F RATE OF BURNING .ASTM D635.. 1.28 IN/MIN r e „ g SMOKE DENSITY.. .. A59,4 D2843 .70.2% m m g , TENSILE STRENGTH* ASTM 0638 1.8%DIFF .. 2,1," c"3 ' COMPARATIVE TENSILE STRENGTH AFTER WEATHERING .DOUBLE DOOR UNIT.-W,SIDELITES o g§g 4500 HOURS XENON ARC METHOD 1 E 0. ® ® ® ® Q2 ® , - ® ® 1 ---T ® ® ' -- D ® ® ® ® 9 � fl :flfl _ o� e.�, r+0 O : u : u� � • • LL oma+ I f J0 0 0 0 o - a w INGLE_DOORU „NIT DOUBLE DOOR UNIT SINGLE DOOR UNIT SINGLE DOOR UNIT .51ti,..... !0•Z A T VT's S. •t !!o.... of -, 1__ WITH SIDELITE WITH.SIDELITE m • IDa �C) WHERE WATER INFILTRATION PERFORMANCE IS DESIGN PRESSURE RATING REQUIRED TO BE 15% OF DESIGN PRESSURE CONFIG MAX WIDTH INSWING OUTSWING INSWING BUMPER 0/S Z-SERIES 0/SHIGH DAM.0/S- T4 0/S HP BUMP 0/S X 37.5". +70.0 / -70.0 +70.0 -70.0 N/A +20.0/ -20.0 +30.0 7-30.0'+50.0 / -50.0 +50.0 / -50.0 +50.0 / -50.0 a XX 74" +55.0 7 -55.0 +55.0 7-55.0 N A ' +20.0 / -20.0 +30.0 -30.0 .+50.0 50.0. N/A N/A OX or XO 75" +55.0 / -55.0 +55.0 / -55.0 N A +20.0 '-20.0 +30.0 -30.0 +50.0-7 -50.0 N/A. N/A. Z & OX0 112.5": +55.0 / -55.0 +55.0 / -55.0 N A +20.0 •-20.0 +30.0/ -30.0 +50.0 / -50.0 N/A N/A ' 3t OXXO I 149" +55.0 / -55.0 +55.0J -55.0 N/A . +20.0_ -20.0 +30.0 / -30.0 +50.0 / -50.0 N/A N/A DAM: 5/26/17 �E: N.T.S. , -. _. AddlndmtoNN!! DWG.MI SWS TABLE OF CONTENTS %f'/� MK. - SHEET DESCRIPTION CsNlmtloA1 . 10EOlFig4*7. � ! / KURT BALTHAZOR DRAWING NO.: 1 TYPICAL ELEVATIONS & GENERAL NOTES HeAtialBy. ,',,,f -_ siprim - FLORIDA P.E. DWG-MA-R0211-17 -- 2 ANCHORING LOCATIONS.& DETAILS p X56533 3 ANCHORING LOCATIONS & DETAILS _ • SHEET I of 3 i IC � pp o ? 6"— --- SEE DETAIL 6" U Q " 3 — 3 Q —i 3" r — 3' 30. " �I Ji b 3• J 7 I i r I I I 't1 1-- — in I, 6 6" 6 3 � � W _,_g- ID ^� I ma I W o Q M in O co a B,SEE DETAIL In — N }.D• — — `� SEE DETAIL oIN •C• — © — m w (ti 1 —I SEE DETAIL , A CY 4;1 fl oce ui - _ I _� � _ v I �liP w C,� 3" 6" 3• 3' 3" Si�". 3" j13.6• 1_3-16"� 1—6" R SEE DETAIL ' r s lik .F. #8 x 2" u, a I � ASTRAGAL RETAINER BOLT HOLE #8 x 2" #10 x 5/8" MUSTBEDRILLEDTHROUGH cnoTHETHRESHOLD & INTOTHE -+ 0 x 1112111111 #8 x 2' #10 x 5/8' � FORA 1.375" THROWw�1 ; Irv�b. #10 x 1- #10 " 111111, DETAIL "E" ASTRAGAL DETAIL "F" ASTRAGAL. 10 x 2-1 2 ' � o �Ji lir, # / ATTACH ASTRAGAL RETAINER BOLT o #10 x 1" STRIKE PLATE TO FRAME o #10 x 5/8 ®�� AS SHOWN. DETAIL "C" DETAIL 'b" m 1- 1 0.9621 HOT MELT 1,375" '`): 7.437"Ft r ELASTOMER'''•••*,... st )7,15t... FI "1 A 11 6 X 1-1/2'PHS INSWING THRESHOLD BUMPER 0/S THRESHOLD 14 0/S THRESHOLD "• a z HOT MELT 1/2"BITE Ito UM ELASTOMER .!%..- 1 I�W7lIIQ3TpIPk1.:_ 1C .:44'N'•:. .13741 I 1 DATE 5/zs/7 z .16/111—A`'.....-..- / -_1n ....•, 1,482"•l/t �. 1.75" 1.047" MEMOS 1t0E8I4B SF n IS" N.T.S. 1.437 DWG.Br: SWS �llJ9l+� TYPICAL GLAZING DETAIL T T T NON-IMPACT GLASS "'R•B: DRAWING NO.: Z-SERIES_0/S THRESHOLD HIGH DAM 0/S THRESHOLD HP 0/S THRESHOLD DWG-MA-F10211-n - ------ - --- ----- - SHEET 2 OF 3 SEE DETAIL 6"— — —6" C CO E" S . 2 N — " o— .rr " L — 3"• --3" O I .1 r . h ' ..__ •-.1 Q 7 i 1--6" I I L - - IT — I 1 i • r 1 J 6" 6" — —6" 6" I } 0 CC In bn 6. f Iw o z Sv)O MN N -. - O U o a a SEE DETAIL ¢ LIU U q. 4.. } "D" SHT. 2 — I — Ln (Il r SEE DETAIL a �1 •"C.. SHT. 2 0 w (ii '1 —II w a L A /� G ® 7 2 a 6^ 6J 1- F ip n 6" I &� 1 l, : H6., eO i� rt. I HUH I Igi W,o . s• .1 d -r 3" 3" 3"6. 6" 3 3 � �i SEE DETAIL o=d "F" SHT. 2 6" — ill •o HARDWARE SCHEDULE 1. KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND g m SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED AATTACHMENT DETAIL; 1 2 o' • e. 2. 4T X 4/ CENTERLINE.FULLMORTISE BUTT HINGES. o 1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, 0.25" .25 1"x1 2 CORRUGATED #10X2" WOOD SCREW SIGNED AND SEALED BY ROBERTO LOMAS, PE " SHIM 3" FROM EACH END 6" FROM EACH END (FLORIDA #62514) WITH THE LOWEST (LEAST) f4: AND 7" OC AND 12" OC r z CL FASTENER RATING FROM THE DIFFERENT FASTENERS � 1 o 0 BEING CONSIDERED FOR USE. JAMB, HEAD, AND . RyLX THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE CAULK #10 WOOD SCREWS OR 1/4" TAPCONS. A PHYSICAL TYPICAL MASONRY ACRYLIC SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR ANCHOR INSTALLATION CAULK CL �� LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2". _ -4- 1111111g1111111 a WOOD SCREW EDGE DISTANCE MIN 3/4". I �� COMBINATION WOOD COMBINATION WOOD 2. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM 1.50" ir+�� MULLION (BOXED) MULLION (BOXED) ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT MIN , �;_0.25" MAX (3) 10X2-1/2" ¢z OF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE ( SHIM OOD SCRBYS MINIMUM EMBEDMENT OF 1-1/4". CL—I I I EACH END „ „6,,,0 „ r.^ OW DATE 5/26/17 .. 3. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO G # Nat - ��� • . x ate:sN.T.S. TRANSFER LOADS TO STRUCTURE. : . RovitmedeM . iiv DWG.BY: SWS 4. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 155 LBS. . TYPICAL WOOD BUCK WK. ANCHOR INSTALLATION G NO.: ,3, INTEGRAL WOODDWG- __ —_ DWG-Mn-F.o2/1-17 , MULLION (CHS) SKEET 3 of 3