HomeMy WebLinkAboutMisc Letters § ® St. • Ducie County
Pemtit:18116-06650 a click here to return to the main Permits page.
PermitStatus-Finaled
Job Description REPLACE EXISTING FASCIA.REPLACE EXISTING WOOD SOFFIT WITH STUCCO SOFRT.
To pay a reinspection fee,please click Pam link for each fee due.You may use Visa,Mastercard,Discover Card,
or echeck to pay,the fee using the Govteller gateway.
T6 schedule an inspection,please select Request for each inspection you would like to schedule.Inspections must be scheduled in the order of the Priority listed below.An inspection will
not schedule until all inspections with a lower Priority number show an"Approved"stars and ALL reinspection fees have been PAID.
To add a note for the Inspectorforseheduled Inspections,please select Add Note,enter note in Inspection Notes textbox below,and click Update fink for each inspection you would like
to add a notefor.
If you are unable to schedule an inspection or require any assistance,please contact the Building Division at(772)462-2171.
Type Cat 9 I Stan. (Pen itType I Name Company Mme I Fa Cell
CmhbaGor 26826 _ WIRELATH JON RJAOCSDN "SFAPOINFE BUILDERS } '(771)332-1996
Request I Add Note I Pay Fee Fee I Cade State. I Priority Date Scheduled I Date Inspected I Lap.W(Commehns I I n
GATE OJDE 12884
FC9 N=e Par Fc Disapproved 1 712.5/2018 7/25/1018 53 SPRAY FOAM,NO VE?0 CALLJONN 772377-0166
INSPECrIONWITH QUE5rMNS 43nal W be af"sturm
Aid z tete ay Fee BARRIERApprove 1 7/25/2018 7/25/2016 53
...,..,.. rz",F22 139-WIRE LATH; I 1 7/25/21118 7/15/2016 53 SPRAY FOAM,NOMWM
az;1111te ;Fee 999-FINAL
Ftp nal 1 8/9/2018 8/9/2018 237 REINSPELMOBL
INSPECrIGNAd,Ft;_=_ Pay Fe:- - 139-WIRE LATH Acopted mas 1 817/2018 819/1018 237 Previously trapeded by David Johnson
Another Permit
o
.I •
• —� � � frf V�� �a oc/�e
� l
a / � sow
,�• : = • Planning&Development Services
Building&Cade Regulation Department
2300 Virginia Ave
Fort Pierce,FL 39982
772.462-2105 Fax 462-6443
INSULAMON INSTALLATION CERTIFICATE
Name: aL
Permit : Address; "t
lots„ ,•••�lodr,`. Subdivision:
The undersignedhereby+Gertifes'that Insulation as been Installed at the above described property as follows:
L Exterior CBS walls have been insulated with........................... ()Spray on cellulose
which thickness,according to the manufacturer: , (}fiberglass blankets
(Densrtj%N/A)will yield an"R"value of `". (}Aluminum.Foil
(.}Other
Exterior France wall have been insulated with........................ (}Spray on cellulose
TO a thickness of, `lhches�which thidmess,accvrding to (}flberglass'biankets
the manufdcturer, '(DensrTy-N/A)will yield an ()Aluminum Fog
"R"value ch ()Other
2 Wiings—Level-have been Insulated with.,,,,:..;..._....»». ,.» ()Fiberglass blankets
to a thickness;-44.i tnChes�whiclftWftesS,aCcording to {)HbeMfass-loose fill
urer
the'manufact r= ` ' ,(Density IV/A)will yield an (}Aluminum Foil
and value of.. " �t g6ther Cellulose-SAB
Ceilings" Cathedral—have been Insulated whir:...»»...„. ., (}Fiberglass blankets
to a thidness of�. ;inches,which thickness,according tel ()Fil�tglass loose fill
the manufacturer, _ Density(N/A)will yield an (}Aturnihum fail
'R"value of.` ()Other 0211ulose$AB
Is>EeriDr kt►ee r►ratls iiaveh�eri insulate ta+dt.�,:»..»......„..,e.. . ()Fibergiass blankets
to a thickness of�lnches.which this ness,according to (JiFbWrethane
the rbanufae.4rie - .(Density NIA)will yield an ()Spray.on cellulase �.�
"RP value of. e3 'Other '
' /Gar��ci},g.�e��partition wafts of conditioned riving areas have been (}�F""llberglass blantcets
.7l7+lunRiN �.tws+:.«.+:w:;wi+.+wwe.aaawiiw»+r.�w..ae...i:..ww t}Spray on cellulose
to a thidcr3ess'ofirid ,which thickness;aomrding tv the ()Rblyurethane
manufacbmwr,-• ,(Density Wkwilt yield an (}Either
'R”value vF' .
MUM-FAMILY,RE5TDBYT14L C095MIXfION ONLY: The common(party)walls separaf#ng dfferej*}ants shall be insulated as
fl)"O ts—Frame/Meal stied wails R-11(Min);CBS Or Concrete watts R-3(Mln)by Energy Code requirements. See Energy Code
Ftev.2/87,.pa1a9MPh 9012(b),vis pages 947,latest edition. These"minimum levels of insulation"are not Inducted the Energy
Ca(ailations,but shaft be Installed in the field,
NOTE* Densitiesofsprayed.on,loose All,yrBny othertOmpvsed-on site Insulation chaff bathe PCF(lb/ft3)average of three(3)
"DRY SAMPLEVofactuai Installation.
_ MER Enterprises,LLC � ' �
PAirt PJasrse Crutaf�on�snb^acRur' Signature vflnsvlatro contraactnr
'26202'
Date of Ce kation
ft-
4NOt79bl7.
_�; k x°u.Yi;l�3un� „�..^� KELLYLYOtlkG
.-��`-� rtic:,.t,�F•.:.'`'rt Sa:anr=.o+t3a �a "%` wanryDubh[-StiteotRorida
,.��,:�' C:tc:rsi5•tcn��.i,'Si�dyt ��.• Commissnn�GG1932a2 '
a.y Cor-r�.Ea^.rtP;14«-.2C:: `'.ta+*_?.�`t MyCemm Eawrr�hci t.2822 '
•" 5prt'.<e tk:eab r,a.una:Acu t Ft-. 8r+tdttl slut u5n\sbeni►�cta,y aUsrt