Loading...
HomeMy WebLinkAboutMisc Letters A 'E E "8u ldin' 'Qur Quality �teputa o One,. ustomer At A Timex; SCC131150472 Property InformationBuildin Information Owner: HARRY&KIMBERLY MAXWELL Wind Zone: 170 MPH. Address: 600 SNEED RD Exposure Category: C FT PIERCE,FL 34945 Minimum Building Dimension: 68 ft. Mean Roof Height: 12 ft. Risk Category: II 'I Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number f Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 70 58 7 35.2 -38.5 2 Int 35 58 7 37.0 -40.2 3 Int 70 58 7 35.2 -38.5 4 End 34 58 7 37.0 =49.1 5 End 16 58 7 37.8 -50.6 6 Int 16 58 7 37.8 -41.0 7 End 50 58 7 36.1 -47.2 8 Int 70 58 7 35.2 -38.5 9 Int 70 58 7 35.2 -38.5 10 End 34 58 7 37.0 -49.1 �11 End 34 58 7 37.0 -49.1 12 Int 35 58 7 37.0 -40.2 T-13 End 70 58 7 35.2 _ -45.5 14 Int 34 58 7 37.0 -40.2 15 Int 70 58 7 35.2 -38.5 16 Int 35 58 7 37.0 -40.2 Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1 WINDOW& DOOR OPFNING INFORMATION A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Comer Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS NUMBER or Interior OR DOOR TYPE NUMBER + PSF TESTED MULLION ( ) (-)PSF (+)PSF (-)PSF SIZE DIMENSIONS REQ YIN/NA REQ Y/N 1 Int Window 7/8"Land IG FL16736.1 60 60 35.2 -38.5 1 74 x 63 70x58 No No 2 Int Window 7/8°Lami FL16177.1 70 70 37.0 -40.2 52x62 35x58 No No 3 Int Window 718"Lami IG FL16736.1 60 60 35.2 -38.5 74x63 70x58 No No 4 End Window 7/8°Lami FL16177.1 70 70 37.0 -49.1 52x62 34x58 No No 5 End Window 7/8°Lami FL16177.1 70 70 37.8 -50.6 52x62 16x58 No No 6 Int Window 7/8°Lami FL16177.1 70 70 37.8 -41.0 52x62 16x58 No No 7 End window 7/8°Lami FL16177.1 70 70 36.1 -47.2 52x62 50x58 No No 8 Int Window 7/6"Lami IG FL16736.1 60 60 35.2 -38.5 74x63 70x58 No No 9 Int Window 7/8"Lami IG FL16736.1 60 60 35.2 -38.5 74x63 70x58 No No 10 End Window 7/8°Lami FL16177.1 70 70 37.0 .49.1 52x62 34x58 No No 11 End Window 7/8a Lami FL16177.1 70 70 37.0 -49.1 52x62 34x58 No No 12 Int Window 7/s Lami FL16177.1 70 70 37.0 -40.2 52x62 35x58 No No 13 End Window 7"'Lam"G FL16736.1 60 60 35.2 -45.5 74x63 70x58 No No 14 Int Window 7/8^Lami FL16177.1 70 70 37.0 -40.2 52x62 34x58 No No 15 Int Window 7/8"L-1IG FL16736.1 60 60 35.2 -38.5 74 x 63 70x58 No No 16 Int Window 7/8°Lami FL16177.1 70 70 37.0 1 -40.2 52x62 35x58 No No