HomeMy WebLinkAboutMisc Letters A 'E E
"8u ldin' 'Qur Quality �teputa o
One,. ustomer At A Timex;
SCC131150472
Property InformationBuildin Information
Owner: HARRY&KIMBERLY MAXWELL Wind Zone: 170 MPH.
Address: 600 SNEED RD Exposure Category: C
FT PIERCE,FL 34945 Minimum Building Dimension: 68 ft.
Mean Roof Height: 12 ft.
Risk Category: II
'I
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number f Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 70 58 7 35.2 -38.5
2 Int 35 58 7 37.0 -40.2
3 Int 70 58 7 35.2 -38.5
4 End 34 58 7 37.0 =49.1
5 End 16 58 7 37.8 -50.6
6 Int 16 58 7 37.8 -41.0
7 End 50 58 7 36.1 -47.2
8 Int 70 58 7 35.2 -38.5
9 Int 70 58 7 35.2 -38.5
10 End 34 58 7 37.0 -49.1
�11 End 34 58 7 37.0 -49.1
12 Int 35 58 7 37.0 -40.2
T-13 End 70 58 7 35.2 _ -45.5
14 Int 34 58 7 37.0 -40.2
15 Int 70 58 7 35.2 -38.5
16 Int 35 58 7 37.0 -40.2
Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.
Page 1 of 1
WINDOW& DOOR OPFNING INFORMATION
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Comer Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS
NUMBER or Interior OR DOOR TYPE NUMBER + PSF TESTED MULLION
( ) (-)PSF (+)PSF (-)PSF SIZE DIMENSIONS REQ YIN/NA REQ Y/N
1 Int Window 7/8"Land IG FL16736.1 60 60 35.2 -38.5 1
74 x 63 70x58 No No
2 Int Window 7/8°Lami FL16177.1 70 70 37.0 -40.2 52x62 35x58 No No
3 Int Window 718"Lami IG FL16736.1 60 60 35.2 -38.5 74x63 70x58 No No
4 End Window 7/8°Lami FL16177.1 70 70 37.0 -49.1 52x62 34x58 No No
5 End Window 7/8°Lami FL16177.1 70 70 37.8 -50.6 52x62 16x58 No No
6 Int Window 7/8°Lami FL16177.1 70 70 37.8 -41.0 52x62 16x58 No No
7 End window 7/8°Lami FL16177.1 70 70 36.1 -47.2 52x62 50x58 No No
8 Int Window 7/6"Lami IG FL16736.1 60 60 35.2 -38.5 74x63 70x58 No No
9 Int Window 7/8"Lami IG FL16736.1 60 60 35.2 -38.5 74x63 70x58 No No
10 End Window 7/8°Lami FL16177.1 70 70 37.0 .49.1 52x62 34x58 No No
11 End Window 7/8a Lami FL16177.1 70 70 37.0 -49.1 52x62 34x58 No No
12 Int Window 7/s Lami FL16177.1 70 70 37.0 -40.2 52x62 35x58 No No
13 End Window 7"'Lam"G FL16736.1 60 60 35.2 -45.5 74x63 70x58 No No
14 Int Window 7/8^Lami FL16177.1 70 70 37.0 -40.2 52x62 34x58 No No
15 Int Window 7/8"L-1IG FL16736.1 60 60 35.2 -38.5 74 x 63 70x58 No No
16 Int Window 7/8°Lami FL16177.1 70 70 37.0 1 -40.2 52x62 35x58 No No