Loading...
HomeMy WebLinkAboutProduct Approval (2) Florida Building Code Online Page 1 of 2 Z 12, I yr /!v BCIS Home i Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications j FBC,Staff,i BCIS Site Map ( Links 'Search Fonda a Product Approval��� USER:Public User Product ADoroval Menu>Product or ADDIIcation Search>ADDlicatlon Ust>Application Detail A, 'k FL# FL1617 -112 Application Type Revision Code Version 2017 Application Status Approved Comments Archived El Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenue Ocala,FL 34474 (352)368-6922 Ext 245 kpine@cws.cc Authorized Signature Kevin Pine kpine@cws.cc Technical Representative ]ay Lathrop Address/Phone/Email 1900 SW 44th Ave Ocala,FL 34474 (352)368-6922 Ext 291 jlathrop@cws.cc Quality Assurance Representative Arturo Monteverde Address/Phone/Email 1900 SW 44th Ave Ocala,FL 34474 (352)368-6922 Ext 221 amonteverde@cws.cc Category Windows Subcategory k14Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lucas A.Turner the Evaluation Report Florida License PE-58201 Quality Assurance Entity KeystoneCertifications,Inc. Quality Assurance Contract Expiration Date 07/21/2020 Validated By Steven M.Urich,PE R Validation Checklist-Hardcopy Received Certificate of Independence FL16177 R2 COI EvalReport812C.Ddf Referenced Standard and Year(of Standard) Standard Year AAMA/W D MA/CSA/101/I.S.2/A440-08 2008 ASTM E1886-05 2005 ASTM E1996-09 2009 PA TAS 201/202/203 1994 Equivalence of Product Standards Certified By https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvyf4ngAXhlOy... 1/3/2018 r Florida Building Code Online Page 2 of 2 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/28/2017 Date Validated 09/29/2017 Date Pending FBC Approval 10/03/2017 Date Approved 12/12/2017 .Summary of Products FL# Model,Number or Name Description 16177.1 SH-8100 PVC Single Hung SH-8100 PVC Single Hung Impact Resistant window. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16177 R2 rI CWS-812C.Ddf Approved for use outside HVHZ:Yes Verified By:Lucas A.Turner 58201 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:+70/-70 Evaluation Reports Other:SH-8100 PVC Impact,no sill anchors required. FL16177 R2 AE EvaIReDOrt812C.Ddf Safety glazing required on outer lite above 30 ft.in HVHZ. Created by Independent Third Party:Yes Glass complies to ASTM E1300-04. Back Next Contact Us::2601 Blair Stone Road Tallahassee Fl,32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvyf4ngAXh l 0y... 1/3/2018 i URNER1239 Jabara Ave. North Port, FL 34288 ENGINEERING & Ph. 941-380-1574 TCONSULTING, INC. FBPE C.O.A. #29779 Evaluation Report 812C August 29,2017 Product Description: Series 8100 PVC Single Hung,Large Missile Impact, 517/8"x 613/4"unit size, +/-70 PSF,no anchors in sill Manufacturer: Custom Window Systems, Inc. 1900 SW 44`h Ave, Ocala,FL 34474 Statement of Compliance: This report evaluates the above-listed product per the requirements of FAC Product Approval Rule Chapter 61G20-3.005 (4). This product complies with the requirements of the 6th Edition(2017)Florida Building Code including the High Velocity Hurricane Zone. The product testing standards performed are outlined below. Technical Documentation: 4) This report, prepared by Lucas A. Turner,P.E.,at 1239 Jabara Ave.,North Port,FL 2) Approval drawing CWS-812C, signed and sealed by Lucas A.Turner,P.E. 3) Test Report NCTL-210-3815-IA,-2,and-2A, by National Certified Testing Laboratories, Orlando, FL,signed and sealed by Gerard J.Ferrara,with testing performed: TAS 201/202/203- 94,ASTM E 1886-02/04/05, 1996-02/04/06/09,and AAMA/WDMA/CSA 101/I.S.2/A440-08 4) Supplemental Calculations to support CWS-812C, signed and sealed by Lucas A.Turner, P.E. Installation: Units must be installed according to approval document CWS-812C. Limitations of Use: This product: • May be used in O/X configuration in sizes and with max. glass DLO heights as shown in CWS- 812C • Is impact resistant and does not require the use of shutters • May be used in the High Velocity Hurricane Zone • Requires 7/8"Insulating Glass consisting of 1/8 Annealed or Tempered outboard lite(Tempered required above 30 ft in HVHZ) —Air—5/16 Laminated(1/8Ann-.090PVB-1/8Ann)inboard lite • Requires Kuraray(Dupont)PVB Interlayer per Miami-Dade N.O.A. 16-1117.021 • Requires Quanex(Mikron)white rigid PVC framing per Miami-Dade N.O.A. 17-0206.101 1 I have evaluated the materials in these NOAs and find that they comply with the requirements of the 6`''Ed. (2017)Florida Building Code for use in this product. Certification of Independence: I do not have,nor do I intend to acquire, nor will I acquire, a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. `i,���ltl�►rr'�f `�`►���,�iC7 REE�V 9e * : = z� �•� STATE OF t 4U 8/29/2017 .��Qfi•r•����1���4`��'`� Lucas A. Turner P.E. FL PE#58201 /y SINGLE HUNG - LARGE MISSILE IMPACT GENERAL NOTES:1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED �(TNIll/N(�1 TO COMPLY WITH THE FLORIDA BUILDING CODE(FBC),CURRENT WINDOW SYSTEMS EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVHZ)AND 1900 SW 44TH AVE. IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED OCALA,FLORIDA 34474 IN ASTM E 1996 PER THE FBC. WWW.CWS.CC 2.GLAZING OPTIONS:(SEE SHEET 2) 53 1/8"MAX P3T.BALLEL614GE WIDTH 8100 PVC 3.CONFIGURATIONS:"O/X". 517/8"MAX UNIT WIDTH SINGLE HUNG 4711/16"GLASS DLO 4.DESIGN PRESSURE RATING: IMPACT -NEGATIVE DESIGN LOADS BASED ON,TESTED PRESSURE AND GLASS TABLES ASTM E-1300-04e01/09. A -POSITIVE DESIGN LOADS BASED ON,TESTED PRESSURE,WATER ¢ z Q z -- -- - INFILTRATION TEST PRESSURE AND GLASS TABLES ASTM E-1300-04e01/09. Z W�OO a W-W w zOz ���� 63' _ __ I 5.ANCHORAGE:THE 331/3%STRESS INCREASE HAS NOT BEEN USED 0 F W�Z 0 3 MAX. IN THE DESIGN OF THIS PRODUCT.SEE SHEET 6 FOR ANCHOR z z 2 z�W mO O OVERALL I I DETAILS.WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD O O�0 cj¢x r m HEIGHT GE ANCHOR CALCULATIONS. 0 Z��z Z F cn N B O I B 2613/16" 6.PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE 4 ��7 z O g z 0 LL U DLO GLASS NOT REQUIRED. > <Q O FW-F O F_=-0 Z zui Of 0 I I 7.ALL FRAMES AND VENTS FULLY WELDED.SMALL JOINT SEAM SEALANT ~ O o }O 3rO m 61 MAY," I 1 USED AT FIXED MEETING RAIL AND JAMB. a z=a 0 c HEIGHT 8.SERIES/MODEL DESIGNATION SH-8100.LINT � _~a w D D- 9.THE DESIGNATION X AND O STAND FOR THE FOLLOWING: �uuUi� X=OPERABLE SASH,0=FIXED SASH I V P..... X03/16' I /8" 10.SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR A.�VPyy......... G EtVS fi Gp2i�� SASH `, ISS LOCATION. t" No 58261 P HEIGHT X I =.. 11.EXTERNAL WEEP SLOT=1/4"x 1-1/4"LOCATED 4"FROM BOTH ENDS. 1) STATE OF �r���F•A-.......% A A s 451/16" �^L GLASS DLO 48 3/8" 9/22/2017 MAX SASH WIDTH LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: GENERAL NOTES AND TABLE OF CONTENTS ELEVATIONS DRAWN BY: DATE: GENERAL NOTES&ELEVATIONS.....1 DESIGN PRESSURE BAT 06/18/12 GLAZING DETAIL.................................2 MAX. UNITS IZE IMPACT RATING SECTION VIEWS.................................3 RATING - DWG tt: REV_ EXTRUSIONS&B.O.M.......................A � � CWS-812 C ANCHOR SCHEDULE&NOTES.........5 51-7/8 x 61-3/4 +/-70 PSF LARGE MISSILE IMPACT scALE: INSTALLATION DETAILS....................6 SHEET 1:15 1 OF 6 WINDOW SYSTEP95 1900 SW 44TH AVE. OCALA,FLORIDA 34474 WWW.CWS.CC 8100 PVC SINGLE HUNG IMPACT a Z aZ3: ZWwo cawoci w zOZ O LL F-W ZI-3:25! 7/8'OVERALL INSULATED GLASS 7/8"OVERALL INSULATED GLASS Z z=m Q K w O p O QF-06<<=�m 1/8'ANNEALED OR TEMPERED 1/8•ANNEALED OR TEMPERED O z U7 y z z F U)D. -':1 to 7/16"AIRSPACE 7/16'AIRSPACE Q -O Z W U)ZO=O LL Z 5/16"LAMINATED GLASS 5116'LAMINATED GLASS Of <fig^O W F f-z ui 1/8"ANNEALED 1/8"ANNEALED W OW W owW !n J .090"PVB INTERLAYER BY DUPONT .090'PVB INTERLAYER BY DUPONT a Z=°' Of O�co p wFw EL a: 1/8'ANNEALED 1!8'ANNEALED d F- d � d ul QUANEX DURASEAL QUANEX DURASEAL tt1 tpREtr` tti IG SPACER IG SPACER ttt wq 4 PURFECT GLAZE'H"OR SIKAFLEX 552 47 PURFECT GLAZE"H"OR SIKAFLEX 552 '��,ay��''C.....Pq!'�� 14 1/2 .GLASS BITE 112GLASS BITE v' No 58201 14 ' " 48 48 9� STATE OF 3 �ct� �O..1.. 1 12 0 ZZ FIXED LITE SASH LITE 9/22/2017 LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: GLAZING DETAILS DRAWN BY: DATE: BAT 06/18/12 DWG 0: REV.: CWS-812 C SETTING BLOCKS PER FBC 2411.3.3.11 scALE: SHEET 1:1 2OF6 INTERIOR QMtEM03 1900 SW 44TH AVE. OCALA,FLORIDA 34474 WWW.CWS.CC 45 3 53 1 38 13 3 3 4 45 8100 PVC D ® SINGLE HUNG IMPACT 0 4 Q z � QZ�: W�o Ill 0 0 ow0 Qwpo 14 I 3 Z Z=m Q K w O_ 3 14 54 14 6 66 63 19 4 0 OF-O0Q=F-� SECTION B-B 0 Z��z Z F z O Z O Z -0- 54 NOTE:LEFT SIDE SHOWS FIXED SECTION VIEW, ¢ �—tL 2 0 O LL Z RIGHT SIDE SHOWS SASH SECTION VIEW. re ¢ 0 w r=O_ �a � F=z W p0�ai 0w U)w LL W 0�(A F- of 0 14 LLI 0 39 D: =~dK�wy D. F- D. 40 e -.%0 ,P giOREW. 1 INTERIOR �6P ��C E til SF.,Qyii 48 �.' No 56201 '�P: 6 6 �90� STATE OF •:��!` 14 53 65 10 66 y 3 3 9/22/2017 18 6 LUCAS A.TURNER,P.E. 2 4 FL PE#58201 3 1239 JABARA AVE. 30 NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: SECTION VIEWS SECTION A-A DRAWN BY: DATE: BAT 06/18/12 DWG#: REV-- CWS-812 C NOTE: ITEMS NOT SHOWN FOR CLARITY: 20,25-26,36-37,44,5152,55-56,64,67-68 scr�E: SHEET 1:2 30176 PARTS LIST FRAME CORNER aMEMSffl REM PART# DESCRIPTIONVENDOR MATERIAL 31/6' CONSTRUCTION1 H-6031 Main Fr.,SH,w/Flg.,PVC,Head Mikron Vinyl 0 2 H-6031 Main Fr.,SH,w/Fig.,PVC,Sill Mikron Vinyl 1 23/16' 1900 SW 44TH AVE. 3 H-6031 Main Fr.,SH,w/Fig.,PVC,L.Jb. Mikron Vinyl 2 I OCALA,FLORIDA 34474 4 H-6031 Main Fr.,SH,w/Fig.,PVC,R.Jb. Mikron Vinyl 3 8 WWW.CWS.CC 6 S-1577 Impact Hook Keymark Alum 4 8 H-6027 Sash Meet.Rail,PVC Mikron Vinyl 21'/16' 1 EW '516'9 H-1497 Reinf.Sash Meet.Rail Keymark Alum 1/16 1/16• 8100 PVC CORNER W ELD10 H-6028 Sash Bottom Rail,PVC Mikron Vinyl (ALL SIDES) SINGLE HUNG 12 H-6004 Sash Side/Top/Bot.Rail Mikron Vinyl 1:8 13 S-1498 Reinf.S.B.R./S.S.R PVC FRAME FLANGE-6031 PVC SASH BTM.RAIL-6028 PVC SASH TOP RAIL-6027 IMPACT 14 S-6064 Glz.Bd.,7/8" Mikron Vinyl 18 S-6013 Scm.Adapt.,w/Nib,PVC,Horiz. Mikron Vinyl ¢ z ¢z� 19 S-6014 Scm.Adapt.,PVC,Vert. Mikron Vinyl Lu 1 1/2• ~ O W O ¢w o 20 S-6029 Sash Stop/Filler,PVC,Vert. Mikron Vinyl 13116'— 3 w z O z W-z t 23 H-1699 Reinforcement,SBR Keymark Alum 7/8^ o LL H W�z O of 24 P-2190 Balance BSI 9/16 t z z=M¢0_W O O O 0E-0d<=F.W 25 P3059 Sash Cam,PVC BSI Plastic 3 v v m U) a I— a 26 P3046 Take Out Clip BSI SS 1/16^ 2118' 1116 SCREWED TOGETH R WITH FIXED MEETING RA L U) z O(7 O Z z D U- 27 P3783 Lock,Impact,PVC Interlock 1116" OUTERFRAME ¢ z U 2 z O u-U 28 P4069 Keeper,Impact,PVC Interlock Zamac 1:6 < O w p F=-Z z Flap REINF.,IMPACT HOOK-1112 H O Q W 30 P3215 Weep'Co�erw/Fla Geer Plastic ¢ N U vi 32 P-3429 Wstp.,0.270 x.187 back FinSeal,Gray Ultrafab PVC SASH SIDE RAIL-6004 FIXED RAIL-1836 w u- W rn 0 W 0)Lu 37 P-4638 #8 x 2-1/2 PH Mod.Truss,Type A,TEK 2 Fastenal Steel a z=a. O O 38 P3768 #8 x 0.625 Ph PH SMS Hub City Steel 1 5/16" 9116' 1 /8. � =~ w W 39 P4051 W#8 x 1.250 Ph FH TEK,Wht. Hub City Steel 112° 't/s• 5118• a ~ a = a 40 P4264W#8 x 3/4 FH PH w/#6 Head,TEK,Wht. Hub City SteelTD 1116 ��puru+ 44 P3342 Seam Sealer,SM 5504 Schnee 7/LF 18 1 5116' 045• r 9 ''Pr1CREW TG����i' 45 P3752 Cap Plug,1/2"Hole M&M Nylon 1/16' 1/16" ��GPS•�� SF•.�Py 47 P3438 Sikaflex 552 or Purfect Glaze°H° Sika/Henkel 1 +`J 48 P3352 Set.Blk.,85 Dur.,1/8"x5/8"x 2"Lg. F.Lowe Rubber PVC sash STOP-6025 PVC SCREEN CATCH-6013 PVC FIXED RAIL COVER-6063 PVC SCREEN SUPPORT-6014 No 58201 51 P-3881 Temporary Lbl.(NFRC/DP) ' 52 P3613 CWS Lbl.(logo) Pro Label 3!4" 5!8" 114• I �9; STATE 53 Sash SEESHEET2 GLASS 3!4" 3 I O". 54 Fixed SEESHEET2 GLASS 3116'r L— ,— 2 t4 '��c •=clOpipP•`���` T 13 15/16' 1• I�(jll�l�il�` (_9) 718• /ON 56 56 P-3281 Spacer Duraseal 62 P3218 Screen Frame,Horiz. Allmetal Alum 1/16 63 P3218 Screen Frame,Vert. Allmetal Alum REINF.S.B.RJS.S.R.-1498 REINF. BTM RAIL-1699 REINF.TOP RAIL-1497 PVC GLAZING BEAD-6064 64 P3321 Screen Frame Comer Key Allmetal Plastic 65 P3581 Screen Cloth,18 x 16 Fiberglass Betterwe Fiberglass yr� 66 P3228 Screen Spline,.155 Dia.,Blk. Dapa Vinyl 67 P3029 Screen Pull Tab Summit Alum 9/22/2017 68 P3033 Screen Spring,SS Fl.Screen SS 70 P3113 Screw Support for PVC T.Plastics Nylon LUCAS A.TURNER,P.E. 71 H-1836 Alum.Fixed Rail Keymark Alum 03/16' 1239 FL JA 58201 71 AA AVE. 72 S-6063 Co%er,Fixed Rail Mikron Vinyl p NORTH PORT,FIL 73 S-1112 Reinforceent,Impact Hook Keymark Alum -1 m 34288 PH.941-380-1574 T_ P3541 #8 x 1/2°,Pan Head,TEK Fastenal Steel 1 5116" 1/2SHEET DESCRIPTION: LINE ITEMS NOT USED: 5" 3116 5,7,11,15-17,21-22,29,31,33-36,4143,46,49-50,55,57-61,69 6 3' BOM BOM AND EXTRUSIONS 718" 1/16° j SCREW SUPPORT-3113 DRAWNBY: DATE: BAT 06!18/12 IMPACT HOOK S-1577 .. _ _ _ DWGii: REW CWS-812 C SCALE: SHEET NOTE:ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. 1:2 40176 WI�(lIU6v(4l(//EMS 6"MAX.(TYP.) 117"MAX.O.C.(TYP.) 1900 SW 44TH AVE. 6"MAX.(TYP.) OCALA,FLORIDA 34474 WWW.CWS.CC SEE NOTE 2 8100 PVC 10 MAX.O.C. I I SINGLE HUNG (TMP') IMPACT 0—INSTALLATION ANCHOR(T/P.) I Q QZO (/1 W ci O ZO�}? Q0O E3;ai LL F-w ---�hITG RAIL Z Z x M Q W W O O O 0 QxF O� v O(nZa F-(na "(TMP.) 0 Z-�-ZF-DW I I Z O0, --jO- I I Q F-- . 0OLLZ >- Q,�, OwF_mO— of 101/72' /\ W O"LU(na W(nW MAX O.C. of Z�W O-1OF- (TYP.) a x n. w O�co I O W F-O W Wr w ttttotubuo �ap t F....... TG�i�y 4"(TYP,) -- -- -- �^ �C E tV SF�.�gi,`i 4"(TYP.) NO ANCHORS REQUIRED IN SILL—i ' No 58201 ANCHOR LAYOUT-(FLANGE) :9 STATE DF '.��l NOTES: telli �0,`1 1.INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION.NO ANCHORS REQUIRED IN SILL. 2.SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX.ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16"IS PRESENT. LOAD BEARING SHIMS SHALL BE ;4zCONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED. 3.ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 6. 9/22/2017 4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST LUCAS A.TURNER,P.E. 8201 BE PROTECTED TO PREVENT REACTION. FL # A JA 1239BARA AVE.A 5.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM NORTH PORT,FL 34288 SPECIFIED IN TABLE 1,SHEET 6. "" PH.941-380-1574 6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE. SHEET DESCRIPTION: INSTALLATIONS TO SOLID CONCRETE OR GROUT-FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND THE SUBSTRATE. ANCHOR SCHEDULE AND INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. NOTES 7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:3"FOR MASONRY,1"FOR WOOD AND METAL. DRAWN BY: DATE: BAT 06/18/12 8.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. DWG n: REV.: SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLE1,SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. CWS 812 C 9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: scALe SHEET FMA/AAMA 100(FIN WINDOWS),FMA/AAMA 200(FLANGE WINDOWS), FMAfWDMA 250(BOX WINDOWS),FMA/AAMAWDMA 300(EXTERIOR DOORS) 1:15 5 OF 6 1 TYPICAL HEAD ANCHORAGE �""� MIN.EMBEDMENTUBSTVVINDObV SYSTEMS LL%J TE MIN.EDGE DIST. SEE TABLE 1 BY OTHERS SEE TABLE 1 114"MAX SHIM SEE TABLE 1 OCALAA, 44TH AVE, L CAFLORIDA 34474 UBSTRATE BY OTHERS W W W.CWS.CC SEE TABLE 1 MIN.EMBEDMENT MIN.EDGE DIST. 8�OO PVC PERIMETER SEALANT SEE TABLE 1 SEE TABLE 1 BY INSTALLER INSIDE AND OUT INSTALLATIONSINGLE HUNG SEALANT BEHIND C� SEETABLE1ANCHOR IMPACT FLANGE BY INSTALLER 1/4"MAX SHIM Q Z ¢Z� a H OWO Wwoci Z W. m W ZOZ 0__ZIW Q aU }Oof m PERIMETER SEALANT LL F-W BYINSTALLER Z Z 2 m¢ W O Q O OF-O �=Ffo� INSIDE AND OUT U U U F-V a F-(n D. INSTALLATION ANCHOR SEALANT BEHIND O Z 7 Z Z F- cn SEE TABLE 1 FLANGE BY INSTALLER Q O Z U U Z LL U } Q§LLQW020Z CONTINUOBEADS g HORIZONTAL SECTION of 2 Q F-~F-Z TREMGLAZE U11600 SEALUS DOUBLE ANT AROUND 6 TYPICAL JAMB ANCHORAGE W 0 of O co O W vl W PERIMETER AT ALL INDICATED POINTS 2, Z LL N'L O_j m I­- a-FRAME AND BUCK BY INSTALLER. LLO W F-Q a OS } a F a Wu�am 114"MAX.SHIM SEALANT BEHIND FLANGE BY INSTALLER fft��� PN�REW t tttr N5 PERIMETER SEALANT �Qp� fi.,�Qt�� BY INSTALLER MIN.EMBEDMENT v: No 58201 :�P INSIDE AND OUT SEETABLEI g*� * ;* ;%9o% STATE OF :amu- SUBSTRATE BYOTHERS r�'�fi•,p( QP:'�'�`� SEE TABLE 1 DGDIST. �rry3g+ •O R. r1Q�'`� q VERTICAL SECTION SEE TABLE 6 TYPICAL SILL ANCHORAGE 9/22/2017 TABLE 1:APPROVED INSTALLATION FASTENERS LUCAS A.TURNER,P.E. SUBSTRATE TYPE JANCHOR TYPE IN.EMBEDMENT Ml§EDGE DIST. FL PE#58201 PERIMETER SEALANT 1239 JABARA AVE. CONCRETE(2.0 KSI MIN.) 3/16"ITW TAPCON 1-112" -1/8" BY INSTALLER NORTH PORT,FL 34288 HOLLOW OR GROUT-FILLED CMU(117 PCF MIN.) 3/16'ITW TAPCON 1" 2" INSIDE AND OUT PH.941-380-1574 - C HORIZONTAL SECTION CONCRETE(2.85 KSI MIN.) 3116"ELCO ULTRACON 1" 1" 6 BOX FRAME INSTALLATION SHEET DESCRIPTION: GROUT-FILLED CMU(ASTM C-90) 3116"ELCO ULTRACON 1-1/4' 2-1/2" HEAD AND SILL SIMILAR FOR BOX INSTALLATION INSTALLATION DETAILS 2X MIN.SOUTHERN PINE(G=0.55) 3/16"ITW TAPCON 1-3/8" 718' OR ELCO ULTRACON FLANGE REMOVAL NOTE:PARTIALLY OR FULLY REMOVING THE FLANGE, 2X MIN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1-3/8" 7/8" UP TO AND INCLUDING A BOX-FRAME APPLICATION IS ACCEPTABLE PROVIDED: DRAWN BY: DATE: BAT 06/18/12 16 GAUGE(0.060")MIN.STEEL STUD #10-16 HILTI KWIK-FLEXOR ITW FULL THREAD 7/16' MIN.1/4"FILLET OF CONSTRUCTION-GRADE ADHESIVE CAULK IS APPLIED DWG REV.: (33 KSI YIELD MIN) - TEK$SELF-DRILLING,SCREW TRU 0.060" INSIDE AND OUT,FULL PERIMETER,BY INSTALLER. - 1/8"ALUM.(6063-T5 MIN.)OR #10 GRADE 5 SELF TAPPING/ FULL THREAD PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS CWS-812 C 1/8"STEEL(33 KSI MIN.) DRILLING SCREW THRU 0.125" 7/16" SHOWN FOR FLANGE WINDOWS. SCALE: SHEET 1.2 60F6