HomeMy WebLinkAboutProduct Approval "Building Our Quality Reputation
One Customer At A Time
SCC131150472
{ Property Information Building Information
1 Owner: AUDREY GREENSLADE Wind Zone: 170 MPH.
Address: 3900 AVENUE I Exposure Category: C
FORT PIERCE,FL 34947 I Minimum Building Dimension: 43 ft.
Mean Roof Height: 12 ft.
Risk Category: II
I
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf') Pressure(psf)
1 End 52 73 7 35.4 -45.8
2-- - Int 36 __--- 49 ---- -----7 37.3 -40.5
_ 3 Int 25 49 7 37.8 -41.0
4 Int 36 49 7 37.3 -40.5
5 Int _36 49 7 37.3 -40.5
1 6 Int — 52 49 7 36.4 -39.6
7 Int 25 24 -- 7 37.8 -41.0
8 Int 52 24 7 37.8 -41.0
9 Int 52 61 7 35.9 -39.1
I
'Prepared in accordance with:ASCE 7-10,Chapter.30. Wind Loads-Components and Cladding.61h Edition(1017)Florida Building Code.
Page 1 of 1
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Comer Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW TYPE ACCEPTANCE
NUMBER or Interior OR DOOR NUMBER + PSF TESTED OPENING SHUTTERS
( ) (-)PSF (+)PSF (-)PSF DIMENSIONS MULLION REQ Y/N
SIZE REQ Y/NINA
1 End Window 7/8"Lami FL5823.1 67.5 67.5 35.4 -45.8 5306 5203 No No
2 Int Window 7/8 Lami FL4091.2 67.5 67.5 37.3 -40.5 52x71 36x49 No No
3 Int Window 7/8"Lami FL4091.2 67.5 67.5 37.8 -41.0 52x71 25x49 No No
4 Int Window 7/8"Lami FL4091.2 67.5 67.5 37.3 -40.5 52x71 36x49 No No
5 Int Window 7/8 Lami FL4091.2 67.5 67.5 37.3 -40.5 52x71 36x49 No No
6 Int Window 7/8"Lam' FL409 L2 67.5 67.5 36.4 -39.6 1 5201 52x49 No No
7 Int Window 7/8"Lami FL4091.2 67.5 67.5 37.8 -41.0 5201 25x24 No No
8 Int Window 7/8"Lami FL4091.2 67.5 67.5 37.8 -41.0 52x71 52x24 No No
9 Int Window 7/8"Lami FL4091.2 67.5 67.5 35.9 -39.1 52x71 52x61 No No