HomeMy WebLinkAboutProduct Approval (2) 4/26/2018 Florida Building Code Online
SIR`.
:4�4,� i taI f I �:ii . ia1E
1 ' GQ _
BCIS Home Log In User Registration i Hot Topics i Submit Surcharge 1 Stats;&Facts Publications ! FBC Staff BCIS Site Map Links Search
Florida
p� y4 Product Approval
p_e USER:Public User
d,
Product Approval Menu>Product or Application Search>Applicatlon List>Application Detail
I FL# FL10674-R13
d.e`1y 9
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscorning.com
I
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com .
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo,OH 43659
(419)376-8360
mel.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M.Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/16/2020
Validated By John W. Knezevich, PE
Y Validation Checklist-Hardcopy Received
Certificate of Independence FL10674 R13 COI 2017 01 COI Nieminen.Ddf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2016
ASTM D3462 2010
ASTM D7158 2011
Equivalence of Product Standards
Certified By
Sections from the Code
Florida Building Code Online
,f
Product Approval Method Method 1 Option D
Date Submitted 10/10/2017
Date Validated 10/11/2017
>f
Date Pending FBC Approval 10/15/2017
1
1' ,Date Approved 12/12/2017
i
Summary of Products
FL# Model,Number or Name Description
10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge shingles
Shingles and Starters `
Limits of Use ((II Installation Instructions
Approved for use in HVHZ:No I FL10674 R13 II 2017 10 FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes III SHINGLES FL10674-R13.pd�
Impact Resistant: N/A I Verified By: Robert J. M. Nieminen PE-59166
Design Pressure: N/A I Created by Independent Third Party: Yes
Other: Refer to ER,Section 5. Evaluation Reports
FL10674 R13 AE 2017 10 FINAL ER OC ASPHALT
SHINGLES FL10674-R13.pdf
Created by Independent Third Party: Yes
"lcxk
! Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal
address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,
please dick here.
Product Approval Accepts:
Credit Card
Safe
W4..,.i/A.,.....,i1...:d..L...:1.�:....
-
�
`
' EXTERIOR RESEARCH&DESIGN, LLC.
o,tifimte Ofxumumnmm#9503
/
353CHRISTIAN STREET,UNIT#13
( � �N� D0�� ����
' 0 ��VV ~�� � @ "�"~�� _ OXFORD,CTO647B
' (203)262-9245
/
EVALUATION REPORT
�
Owens Corning Evaluation Report O379u0'O2.Il-R8
One OYvensCorning Parkway � � FL10674-R13
| To|ed6`OH43GS9 Date ofbsuanme'02/06/2012
� . ~
(740)404-7829 � � ` � Revision 8: 10/09/2017
� `
/
SCOPE-'
This Evaluation is issued under Rule 61G20'3 and the applicable rules and regulations governing the use of
construction mateha/sinthe State ofFlorida.The documentation submittedhas been reviewed byRnb�tNieminen,
P.E. for use of the product under the Florida Building Code and Florida
Building [ode, Residential Volume. The
products descriSed herein have been eva|uated,fnrcompUmnce with the 6th Edition (2017) Florida Building Code
sections noted herein.
/ .
� DssCn|pnOm: Omens Corning Asphalt Roof Shingles
/
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FSC 15Q7'2.7.1yR9D5.2.8.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the .
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referencedQuality Assurance documentation changes. 7iinitylEKD requires a comp!et'
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
�
ADVERTISEMENT: The Evaluation Report number preceded bythe words"'Trinity|ERU Eva|uated^ may bedisplayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
|msPEcT|Om: Uponroguest, acopyofthiyentineEva|uadonReportshaUbepnovdedtotheuuerbythemanufacturernr
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1throuBh&
Prepared by:
.
' |
Robert 1K8.Nieminen P.E. The facsimile seat appearing was authorized»vRobert
mmm,megisavmmNo.eoaaFlorida DCA Awmam . �_°~"^"' mie=men.cc"o1mo9/20z7.This does not serve asm
electronically signed document.
CERTIFICATION oFINDEPENDENCE:
1, nmitv|snodoes not have, nor does it intend »uacquire o, will it acquire, v financial interest ioany company manufacturing o,
distributing products itevaluates.
Z. Trinity I 9RD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nipm\nen' P.E.does not have nor will acquire,a financial interest inany company manufacturing o,distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have-,nor will acquire,a financial interest in any other entity involved in the approval process of the
product. `
( 5. This is a building code evaluation. Neithe'Tnnny|ExD no/Robert mieminen' P.E. are, in any way, the Designer ofRecord for any
i
project onwhich this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
�
.
/
b:
TRINITY ERD �.
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated
compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
2— STANDARDS:
Section Property Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6,1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
3. REFERENCES:
Entity Examination Reference Date
UL LLC(CER9626) Physicals'&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-132453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic an upre are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshire'""are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration', TruDefinition' Duration I 11D9ra ' In Premium Cool, TruDefinition Duration Designer Color
Collection, TruDefinition Oakridge` Oakridge and WeatherGuard HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip&Ridge Shingles:
4.2.1 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidge" Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 Accessory Starter Strips-
4.3.Z . Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
5. LIMITATIONS:
5.1 ' This is a building code evaluation. ,Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate ofAuthorization#9503 6" EDITION 120171 FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 2 of 8
i
TRINITY--ERD
5_4 Wind Classification:
5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable
for use in all wind zones up to Vasd = '150 mph (Vt,it = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
:5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plu's noted herein are
I Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for use in all wind,zones up to VaSd=150 mph (V„It=194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC'1609.4.3, and a mean
roof height of 60 feet or•less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3.
{
6. INSTALLATION:
6.1 Underlavrnent:
i 6.1.1 Undedayment shall be acceptable to Owens Corning and shall hold.current Florida Statewide Product
i
Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3.
6.22 Asphalt Shingles:'
6.2.1 Installation of asphalt shingles shall comply with,the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or 11905.2.6, with the following
Ili exceptions:
Berkshire!shingles require minimum five(5)nails per shingle.
WeatherGuarde HP shingles require minimum six(6)nails per shingle.
Devonshire""shingles require minimum six(6)nails per shingle.
I , Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
irequired. See figures below for details.
I 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
i
Feltunderlayment ' Deck Fettundertiymest Deck Self-adhered
Self-adhered i ?i unde tsy gem
.......Lock' �; r
f(;:- underlayment 4 f
D f co
Drip_ Drip edge Drp— P
ede
Nails located Mads located
2"-3"from save y --2'-3from cave
Sts rt i first y' Self-sealing adhesive SzN seaBng adt estvn
Starter Strip positioned along eave Instal first Starter Strip Plus
shingle with g with 8-removed- ` positioned along eave
6"remover!
Starter Strip shingle overhangs eaves and rakes:i=s." StartarStrip Flus overhangs eaves and rakes 1/4'-3/4"
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
i Certificate of Authorization#9503 6'"EDITION(2017)FSC NON-HVHz EVALUATION FL10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 3 of 8
RD
TRINITY E
6.2.6 Minimum Nailing—Classic°&Supreme: `
Normal• Mansard or Area pare- Normal •Mansard or Area para
Wind Areas Nigh Wend dosvenes y Wind Areas High Wind cleave y
Aram,perm,vlentos normafes Areas viontos fuerres Area para vientoz normales Areas viontos fx=
•�4• (A) t11 "�' �.—'•IB!~., • s Uzi •• is.yz� I•" "1• 2'
2- 11-
t
S'Exposure i 5 Sib'Exposure
Exposieldn
ExposleMn
6.2.7 Minimum Nailing—Berkshire®.:
Saabig strip Sealant strip
J,a tira de sr Wer [a tka de sellador
9 vt 9 W A ve # "Stt.
8
?2" 9 TV
r
t
t
•rrrr
Standard Fastening Pattern 6-Nail Fastening Pattern
Srahiil sirq.
La Pira tie beria(An ,
re~�- aof ayf e'f
�-
r
r
2" /' Aspharoofing avmnt
Cenanto de tachode astaho
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate of Authorization#9503 6' EDITION{2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8;10/09/2017
Page 4 of 8
l
t
TRINITY ERCP
6.2.8 Minimum Nailing—Devonshire':
8n 7"
Nails.
1, _
5518"....._
exposure Sealant location
Expo iclon de 5.5/8 pulp ttbicacion del setlador 1 t
Ten t"Spots of Asphalt Roof.Cement
Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum- Nailing — Duration°, TruDefinition@ Duration, DurationO Premium Cool & TruDefinition
Duration' Designer Color Collection:
(
4-Nail Fastening Pattern 6-Nail Fastening Pattern
' SuteNallEtasttNeg ares rnatn t SureNmtatasterxng aeea w�Cm
,z �Havel ryr�ral II t1mi,Typcu
tr r r 12- � � - u-
ii � _--�._.- ._.._.- .��.�, 4. T—�G-- w.,-�.s:,�i • c....,c a..,>:s...� •c....;r�..vs.....:< Q{
T r-�
Standard Fastening Pattern 6-Nail Fastening Pattern
` Fastening tot Slopes Greater Than 21:12
3 '
ryB . 1
.. 4
�:7 _
tFair i•arou otR.pn.rt aoonng"Cemaat
Mansard or Steep Slope Fastening.Pattern
l
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate ofAuthorirotion#9503 6"EDITION(2017{FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
i
Page 5 of 8
RT INI Eft
.2.1 Minimum Nailing—TruDefinitioWOakridge°,Oakrid o:
4 Nall Pattern 5 Nail Pattern
Esquema con 4 clavos Esquema con 6 clavos
r r
r r
WT Exposure 5 5!8'Exposure Nails
Ex cidnde55/B ui Flaw Er aoade66/B Ld. 5518'Expaure 55/8'Ez sute
Pei P 4 Claws P�� P g Clava Po
Expaiclon de 55,'6 puig. Expoccidn de 66/6 pufg.
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Slopes Greater Than 21:12
F-swaNen?tasf—g.r..—
6.1.E' S•S'H"I � i .� .
Four tSpob of A.pW Roofing C-2
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuard°HP:
I single Glib VbW
14— 2' Y� T �i
via"hirtand
�RsmeTt�rt�rNiliJJr�
a lF�i} din
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-118
Certificate of Authorizotion#9503 6'' EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 6 of 8
i u
I'
TRINITY ERD
6_3 . Hip&Ridge Shingles:
6.3.1 Installation of Berkshire Hip and Ridge.Shingles, High Ridge, WeatherGuardE HP Hip and_Ridge Shingles
and ProEdge Hip &-Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of DuraRidge'°' Hip & Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistance and installation limitations, including the use of hand-sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or 8905,2.5. Staples are not permitted.
i
6.3.3 Minimum Nailing–Berkshire"Hip&Ridge and High Ridge:
Fig.2
. "Dreawn Top Vfen swlemi
Neils__.__.__.,__....—.� ;•�, '-�\'.:=— —� Nbis ii^� !1� aIs�: }:.
����. �— �[-'-,�.z• Toptanmatei t 2^��_T ::.
# `� �`�•' i 3' I ! Place
—r w v • I'
Expo
6.3.4 Minimum Nailing–WeatherGuard°HP Hip and Ridge:
Fig.A 4 A — Fig.C Hip&Ridge Shingle Fastening
PIQ -M
Nobs
Nails
r
i
i
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8
Cerci/icate ofAuthorization#9503 6"_EDITION(2017)FBC NON•HVH2 EVALUATION FL10674•R13
Owens Corning Asphalt Roof Shingles Revision 5:10/09/2017
iiPage 7 of 8
I
TRINITY ERD
C:�"'•r- nlm -ProEdge Hip&Ridge Shingles: .
Prevailing Standard
Wind Direction Fastening 11 '1
Sealant Strip Pattern T
A-7 6'Exposure I II r
r'� i•� ~k-I f-r
12' Sealant
Fasten 7'h' 7'b' 6'Exposure
CoverExpoaed I
Fasteners with �-
Roof Cement
6.3.6 Minimum Nailing—DuraRidgeT' Hip& Ridge Shingles:
Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
Proraitng Wird Dirocccn Top Ve-
'—Dimaiun domimte du wmII. na en Plan
I-.M,
Dimcdon&I ricnto prodcmiranro
4
Nc�ih �� Ov'tnr Coni 9umrlail
1 I �a`ia
rfiF 1 UIe4
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2- Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(631)546-2458; Kanchi.Agrawala-Dokania@ul.com
END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate of Authorization#9503 b7"'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017