Loading...
HomeMy WebLinkAboutProduct Approval y go >• TEAM HORNER l m Unit spew Rcataons PY FICLE 50125 S®145 S0225 S0120R S0166R 143-000 126,000 <: BTUs ;:80/80!.8:0 101x000 = 119,Oa0 _ ... ._ (water temp/ambient air/ 80/80/63 95,000 112,000 134,000 103,000 120,000 relative humidity) 80!50/03Woo-_ 751000 90;000 72,000 82,000 C.O.P. 80/80/80 6.5 6.8 6.5 5.5 5.6 Coefficient of Performance (water temp/ambient air/ 80/50/63 4.0 4.2 4.0 4.0 4.0 relativeum di h i tY Refrigerant 4.0 R41.OA R41A f3410A :R41lyR Electrical Heat or Heat&Cool H H H H &C H &C i�W 1nAvt .. 4 A-208-230/60/1 Voltage/Hz/Phase A A, B&G A B,E&G A& B A, B-200-230/60/3 MaX Er a S)ze' A 60` A 60 A 60 A 50 A 6Q' E-380-415/60/3 B 50 B ;50 8: 50 B 56 6-460/60/3 20 E �0 Min.Circuit Ampacity A-40. A-42.1 A-42.1 A-38.5 A-42.1 B-31.0 B-33.3 B-31.0 B-33.3 G-14.2 E-18.4 E-18.4 G-16.2 G -16.2 Water Flow 0170 30rf0 30170 3000 30170: .. A Heater Bypass Kit is required when flow rates exceed the maximum Physical `Wetght((bs} 268 32$ 328 26$ 32$; Length x Width x Height(in) 34"x 34"X 4" 34"x 34"x 44" 34°x 34"x 44" 34"x 34°x 44" 34°x 34"x 44° Shipping :Weight dies? 329 . uf ,� 3?30 : 320 390 Length x Width x Height(in) 38"x 36"x 49" 38"x 36"x 49" 38"x 36"x 49" 38"x 36"x 49" with ARf stanbfant arrJretatve hutr7itit4eci6ce I .l r Z MAGE IN WA SWIM1t W NG PODlISPA HFR PUNAS HeatWave SuperQuiet®SQ145 HomeProducts HeatWave SuperQuiet®SQ145 ***5.0(1 review) 17'p tt I. y'1? ° C `v t t .. F,+ ;iw `:'mace�rasa:a� The NEWLY redesigned HeatWave SuperQuiet®SQ145 comes t equipped with all standard features.The Patented Thermol-ink Titanium Heat Exchanger at its core makes this unit a power-house that's built to last. Corrosion proof cabinet with AquaTop Scroll Compressor-for quiet operation `) Microprocessor Controls Off-Set Plumbing Contact AquaCal°for your Free heat cost and sizing estimation. F Y � r s�® CE ON. t♦Y ,On AHRI's globally recognized and Industry respected heat pump pool heaters certification program provides outstanding value to equipment and component manufacturers,customers, and government regulators.AHRI Certified®products are subject to rigorous and continuous testing by a third-party laboratory under contract to AHRI.Only products certified by AHRI are \\\\` ' listed in AHRI's Directory of Certified Product Performance,a real-time database at web page. • More information can be found online on the heat pump pool heaters certification Program 1' (web page),and the heat pump pool heaters contractors(web page). 0 Categories:HeatWave SuperQuiet,Pool Heat Pumps Specs Features Brochures&Manuals Specs 60Hz 360°View Specs 50Hz Warranty Reviews(1) Specs 60 Hz SQ145 BTUs (water temp/ambient air/relative humidity) 80/80/80 119,000 80/80/63 112,000 80/50/63 75,000 A Overhead Clearance Qverhangwith gutterZAL I OVERHEAD 5 feet Rain run-off and i1 52 tm1 sprinkletsshouldbe directed away from heater HeatWave SuperWe&and TropiCal®(Top View) BACK 6 inches [15 Cm] r SIDES SIDES 1 foot 1 foot [30 CM] MOM [30 cm] FRONT 3 feet [91 cm] 3.3.b Water Flow Rates Maintain water flow rates as indicated.Please note,these specifications relate to the heat pump only. Code- specified whole system turnover rates must be satisfied. K CAUTION-Failure to heed the following may result in equipment damage. • Water flow exceeding maximum flow rate may damage heat exchanger,such damage will not be covered under the equipment warranty i Page-6 4 S ou1<rollmg��r�rigalaton end Ramwater�tunoff - - - a . Irrigation water may damage hest pump components.Have irrigation water directed away from the heat pump. . The heat pump will withstand normal rainfall.Do not allow a roof slope to direct rainwater onto the heat pump. Have a gutter installed on the roof edge to direct this water away from the heat pump. Or install the heat pump in another location. The heat pump can produce a large amount of water in the form of condensation.The amount of water depends on air temperature and humidity. . Install the heat pump with enough height to allow for water drainage. . Plan for water drainage disposal as needed. otuiitm 'Pad R. wremtents'.'' 7, . Build the heat pump pad out of concrete or another code-approved material. • Confirm the pad can support the weight of the heat pump. See"Weights"on page 40 . Elevate the pad enough to allow for drainage. • Make sure the pad is flat and level. . Have the pad extend at least 6 inches from the heat pump base in all directions. . Do not install the heat pump on soil or grass. . Do not allow the heat pump base to touch the buildings foundation. . Do not place the heat pump directly on a concrete floor inside a building. This can cause noisy equipment vibration.Install vibration dampeners between the heat pump base and floor. . Equipment pad must meet all requirements of authorities having code-related jurisdiction. . Follow all applicable local, state, and national requirements regarding wind load anchoring. . The shipping brackets used to tie the heat pump to the pallet are approved mounting(hurricane)brackets.They can be used to anchor the heat pump to the pad • If needed,contact AquaCar'Customer Support to obtain the correct anchoring kit information.Please have the heat pump model number and serial number when requesting support. See"Identifying Model Specifications"on page 39. 3.3.atlear ances . Proper air circulation is required for the heat pump to operate efficiently.Avoid placing objects near or on top of the heat pump.This includes shrubbery and lawn furniture.These objects will also hinder maintenance access. . Avoid storing chemical containers near the heat pump.The chemicals can cause equipment damage. Page-5