Loading...
HomeMy WebLinkAboutBuilding Permit Application All APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED �Q Date: Permit Number: IT • - Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue,Fort Pierce FL 34982 Phone: (772)462-1553 Fax: (772)462-1578 Commercial Residential X PERMIT TYPE:Residential remodel PROPOSED INPROVEMENT LOCATION Address: 789 Traub Ave, Fort Pierce, FI 34982 PropertyTax ID#: 3403-501-0323-000-4 Lot No.15-20 Site Plan Name: Changani Block No. 12 -Project Name: DETAILED DESCRIPTION OF WORK: Remove and replace existing windows, Repair rotten facia CONSTRUCTION INFORMATION: Additional work to be performed under this permit–check all that apply: _Mechanical _Gas Tank _Gas Piping Shutters Windows/Doors _Electric _Plumbing _Sprinklers _Generator _Roof Pitch Total Sq. Ft of Construction: 1280 Sq. Ft. of First Floor: Cost of Construction:$ 1200 Utilities: —Sewer —Septic Building Height: OWNER/LESSEE: CONTRACTOR: Name Feroz Changani Name:Kenneth 1. Lippard ,Address:2442 SW Louat Rd Company:Lippard Cosntruction Inc. City: Port Saint Lucie State:_ Address:1200 Driftwood Lane Zip Code: 34953 Fax: City: Fort Pierce State:FL Phone No. Zip Code: 34982 Fax: E-Mail: Phone No 772-370-7548 Fill in fee simple Title Holder on next page(if different E-Mail from the Owner listed above) State or County License If value of construction is$2500 or more,a RECORDED Notice of Commencement is required. If value of HVAC is$7,500 or more,a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: _Not Applicable MORTGAGE COMPANY: _Not Applicable Name: Name: Address: Address: City: State: City: State: Zip: Phone Zip: Phone: FEE SIMPLE TITLE HOLDER: _Not Applicable BONDING COMPANY: Not Applicable Name: Name: Address: Address: City: City: Zip: Phone: Zip: Phone: OWNER/CONTRACTOR AFFIDVIT:Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules,bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit,I do hereby agree that I will,in all respects,perform the work in accordance with the approved plans,the Florida Building Codes and St.Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review:room additions, accessory structures,swimming pools,fences,walls,signs,screen rooms and accessory uses to another non-residential use WARNING TO OWNER:Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before commencing ork or recording our Wtice of C ncement, T Sign ture of Owner/ a Cont ctor nt for Owner ignat r ontraZ/,LxenLAol er STATE OF FLORIDA o , } STATE OF FLORIDA ^ , ;COUNTY OF � � COUNTY OF �` .Llr,2 .The f rgoing instr ment was acknowledged before me The forgoing instru ent was acknowledged before me this day of L 2Qby this J—day of4L- ,20a by Pon m+L KAL 4-4r,,4 6:�t'L'aL &W=nel Name of person makiiTg'gtaferfient. Name of person making st6fement. Personally Known OR Produced Identification Personally Known OR Produced Identification Type of Identification Type of Identification 'Produced Produced (Si nature of Notary P lic-State of Flor ) ign ture of Notary Publ -State of Florida) 'Commission No. (Seal) Commission No. (Seal) REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED Rev. 9/26/18 r 2019-02-05 13:02 0 9 >> P 6/9 ` 398 East Dania Beach Blvd. BUILDING DROPS Suite 338 Dania Beach, Fl.33004 A Perfect Solution in Every Drop 954.399.8478 PH Certificate of Authorization;29578 954.744.4738 FX contact@buildingdrops.com Product 14"valuation Report Of JELD-WEN, inc. Builders Vinyl Single Hung CHS 3 Wide Window for Florida product Approval Report No. 3077 Current Florida Building Code Method: 1 —A (Certification) Category: Windows Sub —Category: Single Hung Product: Builders Vinyl Single Hung CHS 3 Wide Window Material: PVC I Product Dimensions: 109"x 74" Prepared For: JELD-MIEN. inc. 3737 Lakeport Blvd. Klamath Falls, 01.1. 97601 ',tlititttr//// F. Prepared by: •»` Q-,.••• �. Hermes F. Narerti, P.E. ��,� 1 •• �0 Florida Professional Engineer#'73778 7 Date:08/08/2014 1 W � Contents: ; 0T•`•.,l ��.•' Evaluation Report Pages 1 -4 i�r/d'."11111111'0%0NA �,��iti� Hermes F.Norero,P.E. Florida No.73778 2019-02-05 13:02 0 9 '> P 719 BUILDING DROPS (/ A A Perfect Solution in Eve Drop Date: 08/08/2014 Every Report Noo:: 3 30077 Certificate of Authorization:29578 Manufacturer: JELD-WEN,Inc. Product Category: Windows Product Sub-Category: Single Hung Compliance Method: State Product Approval Method (1)(a) Product Name: Builders Vinyl Single Hung CHS 3 Wide Window 109 x 74" i Scope: i This is a Product Evaluation Report issued by Hermes F.Norero,P.E.(FL#73778)for JELD-WEN inc. based on Method 1a of the State of Florida Product Approval,Department of Business and ! Professional Regulation -Florida Building Commission. Hermes F.Norero,P.E.does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of jthe product named herein. i This product has been evaluated for use in locations adhering to the current Florida Building Code. s See Installation Instructions SJW2013-011-FBC,signed and sealed by Hermes F. Norero,P.E.(FL It 73778)for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, j excludine the"High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shallbe as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the current Florida Building Code and does require an Impact resistant covering. 5. Site conditions that deviate from the details of drawing SJW2013-011-FBC require further engineering analysis by a licensed engineer or registered architect. 6. See Installation Instructions SJW2013-011-FBC for size and design pressure limitations. I Hermes F. Norero,P.E. Florida No. 73778 Page 2 of 4 2019-02-05 13:03 0 9 >' P 8/9 BUILDING DROP'S A Perfect Solution in Every Drop pate: 08/08/2014 Certificate of Authorization:29578 Report No: 3077 Certification Agency: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a Certification Agency through American Architectural Manufacturers Association(FBC Organization#CER1498). Performance Standards: The product described herein has been tested per: HAMA/WDMA/CSA 101/I.S.2/A440-08 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories (FBC Organization#TST9341) Report#; SJW2013-011 Report Date:02/21/2013 2. Certification Agency American Architectural Manufacturers Association (FBC Organization#CER1498) I i i Hermes F.Norero,P.E. Florida No,73778' Page 3of4 2014-02-05 13:03 0 9 " P 9/9 i � BUILDING DROPS Date: 0 A Perfect Solution in Every Drop o: 3b 014 Report No: 3077 Certificate of Authorization:29578 Installation: 1. Approved anchor types and substrates are as follows: Nailing Fin Installation: A. For two by(2X)wood frame substrate(Min.S.G.=0.42),use#8 Wood Screw type wood frame anchors of sufficient length to achieve minimum embedment of 1.50"into wood framing. i Through Frame Installation: i A. For two by(2X)wood buck substrate(Min.S.G.=0.42), use#10 Wood Screw type installation anchors of sufficient length to achieve a minimum embedment of 1,50"into the wood substrate. B. For concrete(Min.f'c=3000 psi)or masonry(Conforms to ASTM C90)substrate where one by(1X),non-structural,wood bucking is employed,use 3/16"diameter 179 Tapoon type concrete screw anchors of sufficient length to achieve minimum embedment of I 1.25"into concrete or masonry, C. For concrete(Min.f'c=3000 psi)or masonry(Conforms to ASTM C90)substrate where wood bucking is NOT employed, use 3/15" diameter ITO Tapoon type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25"into concrete or masonry. D. For steel stud substrate(Min 18 Ga., Fy=33 ksi),use#8 ITW TEK Screw type steel stud j anchors of sufficient length to achieve minimum 3 threads penetration beyond steel structure. i Refer to Installation Instructions(SfWZ013-01148C)for anchor spacing and more details of the installation requirements. Design Pressure: Design Pressure Rating Positive 50 PSF Negative 50 PSF Hermes F. Norero,P.E. Florida No.73778 Page 4 of 4