Loading...
HomeMy WebLinkAboutProduct Approval (2) Y P4UA OF SOSHomea Log In i User Registration Hot Topics submit surcnarge stats&Fads Puwications [ PSG Staff{ 40S Site Map Units{ Seaich. Florida Product Approval RECEIVED r 0 USER:Public User , fi ae:'c�arrc Product Annrovai Menu>product or AnnlfWHon Search>Aoolicatlon lest>AppliceNon Detail FEB 14 2019 FL# FL12328-R8 ST. Lucie County,Permitting Application Type Revision Code Version 2017 Application Status Approved Comments Archiver! 0 IOl'�OPYL Product Manufacturer TAMKO Building du Address/Phone/Emall PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri_eden@tamko.com Authorized Signature Kerri Eden kerrt_eden@tamko.com Technical Representative Kerri Eden Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri_eden@tamko.com Quality.Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Zachary R.Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 01/07/2019 Validated By Locke Bowden P.E. 2 Validation Checklist—Hardcopy Received Certificate of Independence EL12328 R8 COI TBP14001 4 2-017 FBC Eval Benoit TAMKO Underlavments finaLodf Referenced Standard and Year(of Standard) ftandard Year ASTM D1970 2015 ASTM D226 2009 ASTM D4869 2016 ASTM D6380 2003 TAS 103 1995 Equivalence of Product Standards Certified By AMA" . al Hill G r Sections from the Cade Product Approval Method Method 1 Option D Date Submitted 10/05/2017 Date Validated 10/19/2017 Date Pending FBC Approval 10/20/2017 Date Approved 12/12/2017 Summary of Products FL* Model,Number or Name Descriptlon 12328.1 ASTM Slate Surfaced Rall Roofing Roil roofing surfaced-with mineral granules Limits of Use Installation Instructions Approved for use in HVHZ:Yes F11_23?8 R8 II TBP14001 X2017 FBC Eval Report TAMKO Approved for use outside HVHZ:Yes Underlavments fina{pdf Impact Resistant-N/A Verified By:Zachary R.Priest 74021 Design Pressure:NIA Created by Independent Third Party:Yes Other:See evaluation report for limits of use.. Evaluation Reports FL12328 R8 AE TBP14001 4 2017 FBC Eval Report TAMKO Underlayments final.pri Created by Independent Third Party:Yes 12328.2 ASTM Tile underlayment Coated organic underlayment Limits of Use InstailaEion Instructions Approved for use in HVHZ:Yes F 12328 AS IT TBp14001 4 2017 FBC Eval Report TAMKQ Approved-for use`outslde HVHZ:Yes Underlay ents fihal.pcif Impact Resistant:N/A Verified By:Zachary R.Priest 74021 Design Pressure:N/A Created by Independent third Party:Yes Other:See evaluation report for limits of use: Evaluation Reports FI 12328 128 AE TBP14001 4 2017 FBC Eval Report TAMKO Underlavments final.pdf Created by Independent Third Party:Yes 12328.3 Master.Smooth Asphalt saturated organic underlayment. Limits of UseInstallation Instructions Approved for use in HVHZ:No F 12378 R8 lI TB,P14001 4 2017 FBC Eval Report TAMKO Approved for use outside HVHZ:Yes Underlavments final.odf Impact Resistant:N/A Verified By:Zachary R.Priest 74021 Design Pressure:N/A Created by Independent Third Party.Yes Other:See evaluation report for limits of use. Evaluation.Reports FII 378 R8 AE TBP14001 4 2017 FBC Eval Report TAMKO Underiayments innal.pdf Created by independent Third Party:Yes 12328.4 Moisture Guard A self adhering modified bitumen underlayment. Limits of Use Installation Instructions Approved for use in HVHZ:Yes Fi 12328 R8 11 TBP14001 4 2017 FBC Eval RgOrt TAMKO Approved for use outside HVHZ:Yes UIn erlpyments final.ndf Impact-Resistant:N/A Verified By:Zachary R.Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports' EL12328 R8 AE TSP14003 4 2017 FBC Eva[Report TAMKO UnderlaymenU final.odf Created by Independent Third Party:'Yes 12328.5 No.15 ASTM Asphalt saturated organic felt Limits of Use Installation Instructions Approved for use in HVHZ:Yes rt-j7326 08 II TBP14001 4 2017 FBC Eval Report TAMKO. Approved for use outside HVHZ:Yes Underlavinents final_pdf Impact Resistant:N/A Verified 8y:Zachary R.Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FW328 R8 AE TBP14001 4 2017 FBC Eval Report TAMKO Underi'ayments Final adf Created:by Independent Third Party:Yes 12328.6 No.15 UL Asphalt saturated organic felt Limits of Use Installation Instructions Approved for use in HVHZ:Yes FFL12328 R8 IT TBP 14001.4 2017 FBC Eva[Report TAMKO Approved for use outside HVHZ:Yes Underlavments final.pd Impact Resistant:N/A Verified By:Zachary R.Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001 4 2017 FBC Eval Report TAMKO Underlayments final.pdf Created by Independent Third Party:Yes 12328.7 No.30 ASTM Asphalt saturated organic felt Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL12328 R8 Ii TBP24001 4 2017 FBC Eval Report TAMKO Approved for use outside HVHZ:Yes Underlayments final.pdf Impact Resistant:N/A Verified"By:Zachary R.Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report far limits of use. Evaluation Reports FL123 8 R8 AE TSP14001 4 2017 FBC Eval Report TAMKO Un eriavments finai.odF Created by Independent Third Party:Yes 12328.8 No.30 UL Asphalt saturated organic felt Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL12328 R8 II TBP14001 4 2017 FBC Eval Report TAMKO Approved for use outside HVHZ:Yes Underlayments final.odF Imgact:Resistant:N/A Verified By,Zachary R Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R6 AE TBP24001 4 2017 FBC Eval Report TAMKO Un erlayments final:odf Created by independent Third Party:Yes 12328.9 TAM-FELT Alternate to ASTM D 226,Type II underlayment Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL12326 R8 II TBP140014 2017 FBC Eval Report TAMKQ Approved for use outside,HVHZ:YesUnderlay em nts final.ndf Impact Resistant:N/A Verified By:Zachary R.Priest PE-74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FI-12328 R8 AE TBP14001 4 2017 FBC Eval Report TAMKO Underlayments final.adf Created by Independent Third Party:Yes 12328.10 TW Metal and Tile Underiayment self-adhering modified bitumen underlayment Limits of use Installation Instructions r Approved for use in HVHZ:Yes FL12US R8 II T13P14001 4 2017 FBC Eva[Report TAMKO Approved for use outside HVHZ:Yes Underlaymentsfinai.odf Impact Resistant:N/A Verified By:Zachary R.Priest 74021 Design Pressure:NIA Created,by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FLi 232$ R8 AE TBP14001 4 2017 FBC Eval Report TAMKO Undertayments'final.ndf Created by Independent Third Party:Yes 12328.11 TW Underlayment self-adhering modified bitumen underlayment Limits of Use Installation Instructions Approved for use In HVHZ:Yes F_L12M R8 11 TBP14001 4 2017 FBC Eval Report TAMKO Approved for use outside HVHZ:Yes Underlayments finai.odf Impact Resistant:N%A Verified.By:Zachary.R.,Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports. FL12328 R8 AE TBP14041 4 2017 FBC Eval Report TAMKO Underlayments final.fadf Created'by Independent Third Party:Yes Back Nex Contactds:;26o1 Blair stone Road.Tallahassee R 32399 Phone:850.487-1824 The State of Florida Is an AA/EEO employer.Copydeht,MZ!2013 State of Red tla.::Privacy Statement;:Actgssti igtv statement::Refund Statement Under Florida taw,email addresses are public records.If you donotwant your a-mall address released in response to apublic-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to section 455.275 (1),Florida Statutes,effective October 1,2012,rlicensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The omailsprovided may.be used for official communication with the licensee:However email addresses are public record.If you do not wish to supply a.personal address, please provide the Department with an email address which con be made available to the public.To determine ff you are a licensee under Chapter 455,F.S.,please dick Lme. Proiiaet Approval�Accepts: C + Certicate of Authorization No. 29824 CREEK17520 Edinburgh Drive Tampa,FL 33647 TECHNICAL SERVICES, ILC (813)480-3421 ., EVALUATION REPORT FLowDA Buu.DING CODE,C EDITION(2017) Manufacturer: TAMKO BUILDING PRODUCTS, INC. Issued October 19,2017 P.O.Box 1404 Joplin,MO 64802 (417)624-6644 httto:t/www.tamko.com Quality Assurance: UL LLC(QUA9625) SCOPE Category:. Roofing Subcategory: Underiayments Code Sections: 1507.1.1 Properties: Physical properties PRODUCT DESCRIPTION TAMKOO ASTM Slate ASTM D 6380;Class M,Type 11 underlayment constructed from organic felt saturated Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules. TAMKO@ ASTM Tile ASTM D 6380,Class M,Type 11 underlayment constructed from an organic felt saturated Undertayment with asphalt then coated on both sides with asphalt and surfaced with granules. TAMKO@)Master ASTM D 6380,Class S,Type IV underlayment constructed from'an organic felt saturated Smooth with.asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For use in non-HN/HZ only. TAMKO®Moisture Self adhered, ASTM D 1970 fiberglass teiriforced itt-d�ec! bitumen sheet'nn6rn rane Guar¢@' with a mineral suriacrng:;.and a. emovable release film on-th&.4..,esive side :and removable selvedge telease'tape. TAMKOO No.15 ASTM ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt TAMKO@)No.I S UL ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt Organic Felt` TAMKOV No.30 ASTM ASTM D 226,Type 11 underlayment constructed from a nan-perforated organic felt that is Asphalt Saturated saturated with asphalt Organic'Felt TAMKOV No.30 UL ASTM D 226;Type Il underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt Organic Felt TAMKOV TW Metal and Self-adhered,flexible,ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane Tile Underlayment Mth.a polymer film on the surface and a removable release film on the adhesive side. TAMKOV TW Self-adhered,,, flexible, ASTM D 1970, rubberized asphalt sheet' membrane with a Underlayment polymer film on the surface and a removable release film on the adhesive side. TBP14001.4 FL12328-118 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule til G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughoutihe duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use, or other product attributes that are not specifically addressed herein. TAMKO BUILDING PRODCUTS,INC. CREEK TAMKO Underlayments TECHNICAL SitiRvicr:.s,LLC TAMKO&TAM-FELT Alternate to ASTM D 226,Type I and Type 11 underlayment constructed from a non- perforated organic felt that is Saturated with asphalt. APPLicAmoN METHOD Installation shall be in accordance with the published manufacturer's installation instructions; the FBC, and the requirements below. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked forprotruslon and corrected prior to underlayment application. The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck shall be installed in accordance With FBC requirements. Roof decks shall have no more than 1/8"gap at abutting. joints. The minimum application temperature shall be 50°F except as follows: a) The minimum application temperature of TAMKOO TW Metal and Tile Underlayment and TAMK0@)TW Undedgymehit shall be 40°F. b) The minimum application temperature of TAMK0@ Moisture Guard®shall be 35'17. The minimum roof Slope shall be in accordance with FBC requirements except as follows: - a) The minimum slope of TAMK0@ ASTM Slate Surfaced Roll Roofing shall be 2:12. Undertayments shall be exposed in accordance with the manuftctuirer's recommendations, but In no case shall exposure exceed 80 days. Exception: TAMK0@ TW Metal and Tile Undedayment may be exposed for a maximum 90 days. Self-adh.pritig undedayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ. All roof Coverings shall be mechanically fastened through,the underlayment to the roof deck. Allowable Roof Coverings: Metal Roof Mineral Wood Asphalt Panple and Surfaced Roll Shingles and Slate Clay,and Underlayment Shin les Shingles Roofirig Shakes Shingles concivto Tile TAMKO0 ASTM State Y1 N N N N Y Surfaced Roll Roofing, TAMKO@ ASTM Tile N N N N N Y Underlayment TAMKOV Master Smooth Y1 N N N N N TA Isiureb tia:r-d0 Y N N N N N TAMKOOD No.IS ASTM Asphalt Saturated Organic Y Y Y y2 N N Felt TAMKO@).No.15 ULAsphalt Y Y Y y2 Y N Saturated.Organic Felt TAMKOO No.30.ASTM Asphalt Saturated Organic Y Y Y Y Y Y Felt TAMKOO No.30 UL Asphalt Y Y Y N Y N Saturated Organic Felt TAMKOO TW Metal and Tile Y N N N Y Underlayment TAM. KO@)TWUnderlayment Y Y N N N N TAMKO(D TAM--FELT Y N N N N N Notes: 1)Open valley applications per 1507;2.9.2 2)Wood shingles only TBP14001A 171-1232M8 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule,61 G20-3, The manufacturer shall notify CREEK Technical Services,LLC of any product chariges or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. TAMKO BUILDING PRODCUTS,INC. CREEK TAMKO Underlayments TECHNICAL SERVICES,LLC Limiurow 1) Fire Classification is not within the scope of this evaluation. 2) Wind uplift resistance in not within scope of this evaluation. 3)_ Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBG compliant installation detail shall prevail. 4) Contact the manufacturer when installing at temperatures below the minimum application temperature. 5) Unless otherwise stated,the minimum roof-slope shall be in accordance with FBC requirements. 6)' All underlayments,shall be installed with the roll length parallel to the eave,starting at the eave,and lapped in successive courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturers application instructions. 7) -The underlayment may be used as described in other current FBC product approval documents. 8) The underlayrnent shall not be installed over existing roof coverings. 9) Contact the manufacturer regarding specific exposure limits for each underlayment 10) All products listed in this report shall be manufactured under a quality assurance program in compliance With Rule 61G20-3. REFERENCES 9M Report No. Standard Year PRI Construction Materials Technologies(TST6049) TAP-192-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TSTqQ49) TAP-193-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) TAP-214-102-01 ASTM 0 4869 2016 PRI Construction Materials Technologies(TST6049) TAP-215-02-01 ASTM D 226 2009 PRI Construction Materials Technologies(17ST6049) TAP-216-02-03 ASTM D 6380 2003(2013) PRI Construction Materials Technologies(TST6049) TAP-217-02-OIRE\/ ASTM D 6380 2003(2013) PRI Construction Materials Technologies(TST6049) TAP-218-02-01 ASTM D 226 2009 PRI Construction Materials Technologies(TST6049) TAR-219-02-01 ASTM D 226 2009 PRI Construction Materials Technologies(TST6049) TAP-220-02-01 ASTM D 6380 2003(2013) PRI Construction Materials Technologies(TST6049) TAP-222-02-01 ASTM D 4860 2016 PRI Construction Materials Technologies(TST6049) TAP-245-02-01 TAS 103 1995 ASTM D 4798 2011 PRI Construction Materials Technologies(TST6049) TAP-311-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) TAP-319-02-01.1 ACC 188 2012 PRI Construction Materials Technologies(TST6049) TAP-387-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) TAP-388-02-01 ASTM D 1970 2015a UL Li-c(rst9628) 13CA12269 ASTM D 226 2009 TBP14001.4 FL12328-R8 Page 3 of 4 This evaluation report Is provided for State of Florida product approval under Rule 6IG20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODCUITS,INC. TAMKO Underlayments TECHNICAL SERVICES,LLC COMPLIANCE STATEMENT The products_evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code,6u`Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. 1�*��trltlrrrrrr�t � 2017.10.19- No nNo 74021 (� 12:15:58 � lRP4,y�HLmwaIM v. , 04'00' STATEOF . 41 �'rd�.'•,p� P••`���+ Zachary R.Priest,P.E. • , O R Florida Registration No.14021 �O N A� 0 Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any dompany manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,not will acquire,a financial interest In any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P:E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the producL END OF REPORT TBP14001.4 FL12328-R8 Page 4 of 4 This evaluation report is provided fol-State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify.CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use, or other product attributes that are not specifically addressed herein.