HomeMy WebLinkAboutProduct Approval (2) Y
P4UA OF
SOSHomea Log In i User Registration Hot Topics submit surcnarge stats&Fads Puwications [ PSG Staff{ 40S Site Map Units{ Seaich.
Florida
Product Approval RECEIVED
r 0 USER:Public User ,
fi ae:'c�arrc
Product Annrovai Menu>product or AnnlfWHon Search>Aoolicatlon lest>AppliceNon Detail FEB 14 2019
FL# FL12328-R8 ST. Lucie County,Permitting
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archiver! 0 IOl'�OPYL Product Manufacturer TAMKO Building du
Address/Phone/Emall PO Box 1404
Joplin,MO 64802
(417)624-6644 Ext 2305
kerri_eden@tamko.com
Authorized Signature Kerri Eden
kerrt_eden@tamko.com
Technical Representative Kerri Eden
Address/Phone/Email PO Box 1404
Joplin,MO 64802
(417)624-6644 Ext 2305
kerri_eden@tamko.com
Quality.Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R.Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 01/07/2019
Validated By Locke Bowden P.E.
2 Validation Checklist—Hardcopy Received
Certificate of Independence EL12328 R8 COI TBP14001 4 2-017 FBC Eval Benoit TAMKO
Underlavments finaLodf
Referenced Standard and Year(of Standard) ftandard Year
ASTM D1970 2015
ASTM D226 2009
ASTM D4869 2016
ASTM D6380 2003
TAS 103 1995
Equivalence of Product Standards
Certified By
AMA"
. al Hill
G
r Sections from the Cade
Product Approval Method Method 1 Option D
Date Submitted 10/05/2017
Date Validated 10/19/2017
Date Pending FBC Approval 10/20/2017
Date Approved 12/12/2017
Summary of Products
FL* Model,Number or Name Descriptlon
12328.1 ASTM Slate Surfaced Rall Roofing Roil roofing surfaced-with mineral granules
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes F11_23?8 R8 II TBP14001 X2017 FBC Eval Report TAMKO
Approved for use outside HVHZ:Yes Underlavments fina{pdf
Impact Resistant-N/A Verified By:Zachary R.Priest 74021
Design Pressure:NIA Created by Independent Third Party:Yes
Other:See evaluation report for limits of use.. Evaluation Reports
FL12328 R8 AE TBP14001 4 2017 FBC Eval Report TAMKO
Underlayments final.pri
Created by Independent Third Party:Yes
12328.2 ASTM Tile underlayment Coated organic underlayment
Limits of Use InstailaEion Instructions
Approved for use in HVHZ:Yes F 12328 AS IT TBp14001 4 2017 FBC Eval Report TAMKQ
Approved-for use`outslde HVHZ:Yes Underlay ents fihal.pcif
Impact Resistant:N/A Verified By:Zachary R.Priest 74021
Design Pressure:N/A Created by Independent third Party:Yes
Other:See evaluation report for limits of use: Evaluation Reports
FI 12328 128 AE TBP14001 4 2017 FBC Eval Report TAMKO
Underlavments final.pdf
Created by Independent Third Party:Yes
12328.3 Master.Smooth Asphalt saturated organic underlayment.
Limits of UseInstallation Instructions
Approved for use in HVHZ:No F 12378 R8 lI TB,P14001 4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ:Yes Underlavments final.odf
Impact Resistant:N/A Verified By:Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party.Yes
Other:See evaluation report for limits of use. Evaluation.Reports
FII 378 R8 AE TBP14001 4 2017 FBC Eval Report TAMKO
Underiayments innal.pdf
Created by independent Third Party:Yes
12328.4 Moisture Guard A self adhering modified bitumen underlayment.
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes Fi 12328 R8 11 TBP14001 4 2017 FBC Eval RgOrt TAMKO
Approved for use outside HVHZ:Yes UIn erlpyments final.ndf
Impact-Resistant:N/A Verified By:Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports'
EL12328 R8 AE TSP14003 4 2017 FBC Eva[Report TAMKO
UnderlaymenU final.odf
Created by Independent Third Party:'Yes
12328.5 No.15 ASTM Asphalt saturated organic felt
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes rt-j7326 08 II TBP14001 4 2017 FBC Eval Report TAMKO.
Approved for use outside HVHZ:Yes Underlavinents final_pdf
Impact Resistant:N/A Verified 8y:Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FW328 R8 AE TBP14001 4 2017 FBC Eval Report TAMKO
Underi'ayments Final adf
Created:by Independent Third Party:Yes
12328.6 No.15 UL Asphalt saturated organic felt
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FFL12328 R8 IT TBP 14001.4 2017 FBC Eva[Report TAMKO
Approved for use outside HVHZ:Yes Underlavments final.pd
Impact Resistant:N/A Verified By:Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001 4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Created by Independent Third Party:Yes
12328.7 No.30 ASTM Asphalt saturated organic felt
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 Ii TBP24001 4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ:Yes Underlayments final.pdf
Impact Resistant:N/A Verified"By:Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report far limits of use. Evaluation Reports
FL123 8 R8 AE TSP14001 4 2017 FBC Eval Report TAMKO
Un eriavments finai.odF
Created by Independent Third Party:Yes
12328.8 No.30 UL Asphalt saturated organic felt
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 II TBP14001 4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ:Yes Underlayments final.odF
Imgact:Resistant:N/A Verified By,Zachary R Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328 R6 AE TBP24001 4 2017 FBC Eval Report TAMKO
Un erlayments final:odf
Created by independent Third Party:Yes
12328.9 TAM-FELT Alternate to ASTM D 226,Type II underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12326 R8 II TBP140014 2017 FBC Eval Report TAMKQ
Approved for use outside,HVHZ:YesUnderlay em nts final.ndf
Impact Resistant:N/A Verified By:Zachary R.Priest PE-74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FI-12328 R8 AE TBP14001 4 2017 FBC Eval Report TAMKO
Underlayments final.adf
Created by Independent Third Party:Yes
12328.10 TW Metal and Tile Underiayment self-adhering modified bitumen underlayment
Limits of use Installation Instructions
r Approved for use in HVHZ:Yes FL12US R8 II T13P14001 4 2017 FBC Eva[Report TAMKO
Approved for use outside HVHZ:Yes Underlaymentsfinai.odf
Impact Resistant:N/A Verified By:Zachary R.Priest 74021
Design Pressure:NIA Created,by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FLi 232$ R8 AE TBP14001 4 2017 FBC Eval Report TAMKO
Undertayments'final.ndf
Created by Independent Third Party:Yes
12328.11 TW Underlayment self-adhering modified bitumen underlayment
Limits of Use Installation Instructions
Approved for use In HVHZ:Yes F_L12M R8 11 TBP14001 4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ:Yes Underlayments finai.odf
Impact Resistant:N%A Verified.By:Zachary.R.,Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports.
FL12328 R8 AE TBP14041 4 2017 FBC Eval Report TAMKO
Underlayments final.fadf
Created'by Independent Third Party:Yes
Back Nex
Contactds:;26o1 Blair stone Road.Tallahassee R 32399 Phone:850.487-1824
The State of Florida Is an AA/EEO employer.Copydeht,MZ!2013 State of Red tla.::Privacy Statement;:Actgssti igtv statement::Refund Statement
Under Florida taw,email addresses are public records.If you donotwant your a-mall address released in response to apublic-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to section 455.275
(1),Florida Statutes,effective October 1,2012,rlicensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
omailsprovided may.be used for official communication with the licensee:However email addresses are public record.If you do not wish to supply a.personal address,
please provide the Department with an email address which con be made available to the public.To determine ff you are a licensee under Chapter 455,F.S.,please
dick Lme.
Proiiaet Approval�Accepts:
C +
Certicate of Authorization No. 29824
CREEK17520 Edinburgh Drive
Tampa,FL 33647
TECHNICAL SERVICES, ILC (813)480-3421
.,
EVALUATION REPORT FLowDA Buu.DING CODE,C EDITION(2017)
Manufacturer: TAMKO BUILDING PRODUCTS, INC. Issued October 19,2017
P.O.Box 1404
Joplin,MO 64802
(417)624-6644
httto:t/www.tamko.com
Quality Assurance: UL LLC(QUA9625)
SCOPE
Category:. Roofing
Subcategory: Underiayments
Code Sections: 1507.1.1
Properties: Physical properties
PRODUCT DESCRIPTION
TAMKOO ASTM Slate ASTM D 6380;Class M,Type 11 underlayment constructed from organic felt saturated
Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules.
TAMKO@ ASTM Tile ASTM D 6380,Class M,Type 11 underlayment constructed from an organic felt saturated
Undertayment with asphalt then coated on both sides with asphalt and surfaced with granules.
TAMKO@)Master ASTM D 6380,Class S,Type IV underlayment constructed from'an organic felt saturated
Smooth with.asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For
use in non-HN/HZ only.
TAMKO®Moisture Self adhered, ASTM D 1970 fiberglass teiriforced itt-d�ec! bitumen sheet'nn6rn rane
Guar¢@' with a mineral suriacrng:;.and a. emovable release film on-th&.4..,esive side :and
removable selvedge telease'tape.
TAMKOO No.15 ASTM ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKO@)No.I S UL ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt
Organic Felt`
TAMKOV No.30 ASTM ASTM D 226,Type 11 underlayment constructed from a nan-perforated organic felt that is
Asphalt Saturated saturated with asphalt
Organic'Felt
TAMKOV No.30 UL ASTM D 226;Type Il underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt
Organic Felt
TAMKOV TW Metal and Self-adhered,flexible,ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane
Tile Underlayment Mth.a polymer film on the surface and a removable release film on the adhesive side.
TAMKOV TW Self-adhered,,, flexible, ASTM D 1970, rubberized asphalt sheet' membrane with a
Underlayment polymer film on the surface and a removable release film on the adhesive side.
TBP14001.4 FL12328-118 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule til G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughoutihe duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use, or other product attributes that are not
specifically addressed herein.
TAMKO BUILDING PRODCUTS,INC.
CREEK TAMKO Underlayments
TECHNICAL SitiRvicr:.s,LLC
TAMKO&TAM-FELT Alternate to ASTM D 226,Type I and Type 11 underlayment constructed from a non-
perforated organic felt that is Saturated with asphalt.
APPLicAmoN METHOD
Installation shall be in accordance with the published manufacturer's installation instructions; the FBC, and the
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be
checked forprotruslon and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance With FBC requirements. Roof decks shall have no more than 1/8"gap at abutting.
joints.
The minimum application temperature shall be 50°F except as follows:
a) The minimum application temperature of TAMKOO TW Metal and Tile Underlayment and TAMK0@)TW
Undedgymehit shall be 40°F.
b) The minimum application temperature of TAMK0@ Moisture Guard®shall be 35'17.
The minimum roof Slope shall be in accordance with FBC requirements except as follows: -
a) The minimum slope of TAMK0@ ASTM Slate Surfaced Roll Roofing shall be 2:12.
Undertayments shall be exposed in accordance with the manuftctuirer's recommendations, but In no case shall
exposure exceed 80 days.
Exception: TAMK0@ TW Metal and Tile Undedayment may be exposed for a maximum 90 days.
Self-adh.pritig undedayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ.
All roof Coverings shall be mechanically fastened through,the underlayment to the roof deck.
Allowable Roof Coverings:
Metal Roof Mineral Wood
Asphalt Panple and Surfaced Roll Shingles and Slate Clay,and
Underlayment Shin les Shingles Roofirig Shakes Shingles concivto Tile
TAMKO0 ASTM State Y1 N N N N Y
Surfaced Roll Roofing,
TAMKO@ ASTM Tile
N N N N N Y
Underlayment
TAMKOV Master Smooth Y1 N N N N N
TA Isiureb tia:r-d0 Y N N N N N
TAMKOOD No.IS ASTM
Asphalt Saturated Organic Y Y Y y2 N N
Felt
TAMKO@).No.15 ULAsphalt Y Y Y y2 Y N
Saturated.Organic Felt
TAMKOO No.30.ASTM
Asphalt Saturated Organic Y Y Y Y Y Y
Felt
TAMKOO No.30 UL Asphalt Y Y Y N Y N
Saturated Organic Felt
TAMKOO TW Metal and Tile Y N N N Y
Underlayment
TAM. KO@)TWUnderlayment Y Y N N N N
TAMKO(D TAM--FELT Y N N N N N
Notes: 1)Open valley applications per 1507;2.9.2
2)Wood shingles only
TBP14001A 171-1232M8 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule,61 G20-3, The manufacturer shall notify CREEK
Technical Services,LLC of any product chariges or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
TAMKO BUILDING PRODCUTS,INC.
CREEK TAMKO Underlayments
TECHNICAL SERVICES,LLC
Limiurow
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance in not within scope of this evaluation.
3)_ Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBG
compliant installation detail shall prevail.
4) Contact the manufacturer when installing at temperatures below the minimum application temperature.
5) Unless otherwise stated,the minimum roof-slope shall be in accordance with FBC requirements.
6)' All underlayments,shall be installed with the roll length parallel to the eave,starting at the eave,and lapped
in successive courses installed up the deck in a manner that effectively sheds water from the deck. End
laps shall be staggered between courses in accordance with the manufacturers application instructions.
7) -The underlayment may be used as described in other current FBC product approval documents.
8) The underlayrnent shall not be installed over existing roof coverings.
9) Contact the manufacturer regarding specific exposure limits for each underlayment
10) All products listed in this report shall be manufactured under a quality assurance program in compliance With
Rule 61G20-3.
REFERENCES
9M Report No. Standard Year
PRI Construction Materials Technologies(TST6049) TAP-192-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TSTqQ49) TAP-193-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-214-102-01 ASTM 0 4869 2016
PRI Construction Materials Technologies(TST6049) TAP-215-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(17ST6049) TAP-216-02-03 ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-217-02-OIRE\/ ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-218-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAR-219-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-220-02-01 ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-222-02-01 ASTM D 4860 2016
PRI Construction Materials Technologies(TST6049) TAP-245-02-01 TAS 103 1995
ASTM D 4798 2011
PRI Construction Materials Technologies(TST6049) TAP-311-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-319-02-01.1 ACC 188 2012
PRI Construction Materials Technologies(TST6049) TAP-387-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-388-02-01 ASTM D 1970 2015a
UL Li-c(rst9628) 13CA12269 ASTM D 226 2009
TBP14001.4 FL12328-R8 Page 3 of 4
This evaluation report Is provided for State of Florida product approval under Rule 6IG20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODCUITS,INC.
TAMKO Underlayments
TECHNICAL SERVICES,LLC
COMPLIANCE STATEMENT
The products_evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code,6u`Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer.
1�*��trltlrrrrrr�t � 2017.10.19-
No
nNo 74021 (� 12:15:58
� lRP4,y�HLmwaIM v. ,
04'00'
STATEOF . 41
�'rd�.'•,p� P••`���+ Zachary R.Priest,P.E.
• , O R Florida Registration No.14021
�O N A� 0 Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any dompany manufacturing or distributing products under this
evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R.Priest,P.E.does not have,not will acquire,a financial interest In any company manufacturing or distributing products under this evaluation.
Zachary R.Priest,P:E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the producL
END OF REPORT
TBP14001.4 FL12328-R8 Page 4 of 4
This evaluation report is provided fol-State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify.CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use, or other product attributes that are not
specifically addressed herein.