HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2
6 sSr+v¢. yi
# wy kM-y4 s "hnM ' ✓.'fix .. y 1 s 3F.�F',''�'A
ke �eik
€ BCIS Home Log In w User Registration Hot Topics Submit Surcharge i Stats&Facts Publications FBC Staff i BCIS Site Map Links Search~~
3� IJil�l3
r Ae iUSER PubhcUser al RECEIVED
Product Aroval Menu>Producr Ap I-fcation-$earth>Alicatlon List>Application Detail
FEBy 1 2019
oot oppf G D
F he �v FL# FL10674-1113 ST. Lucie Count
Application Type Revision y, Permitting
Code Version 2017
Application Status Approved
Comments
Archived
FILt %.O%apy
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829'
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscoming.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Coming PKWY
Toledo,OH 43659
(419)376-8360
mel.sancrant@owenscomig.com
Quality Assurance Representative
Address/Phone/Email
Category Rooting
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M. Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/16/2020
Validated By John W. Knezevich,PE
1: Validation Checklist-Hardcopy Received
Certificate of Independence FL10674 R13 COI 2017 O1 COI Nieminen.Ddf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2016
ASTM D3462 2010
ASTM D7158 2011
Equivalence of Product Standards
Certified By
Sections from the Code
http://w-ww.floridabuilding.orgipr/pr app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2... 1/15/2018
Florida Building Code Online _ Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 10/10/2017
Date Validated 10/11/2017
Date Pending FBC Approval 10/15/2017
Date Approved 12/12/2017
SummarV of Products
FL# Model,Number or Name Description
10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,S-tab,laminated,starter and hip&ridge
Shingles and Starters shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL10674 R13—H 2017 10 FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-RQ.pdf
Impact Resistant:N/A Verified By: Robert].M. Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other:Refer to ER,Section S. Evaluation Reports
FL10674 R13 AE 20_17 10 FINAL ER OC ASPHALT
SHINGLES FL10674-R13.odf �A
Created by Independent Third Party:Yes
Back Next
Contact Us::.2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida.is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mall to this entity.Instead,contact the office by phone or by traditional mail ff you have any questions,please contact 850.487.1395.'Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emalls provided maybe used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
K�xl
{:red:!Cara
Sate
http://www.floridabuildinor.org/pr/pr app_dtl.aspx?paraln=wGEVXQwtDgtBNbEY5V%2... 1/15/2018
r. . .
EXTERIOR RESEARCH&DESIGN, LLC.
Certificate ofAuthorization#9503
l ' 353 CHRISTIAN STREET,UNIT#13
'ERD OXFORD,CT 06478
(203)262-9245
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-R8
One Owens Corning Parkway FL10674-1113
Toledo,OH 43659 Date of Issuance:02/06/2012
(740)404-7829 Revision 8: 10/09/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1/R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity(ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by: —
o.
���; ter'^~,.4�,•1t
Robert J.M.Nieminen,P.E. The facsimile seal appearing was authorized by Robert
Florida Registration No.59166,Florida DCA ANE1983
,jar+rn;i« Nieminen,P.E.on 10/09/2017. This does not serve as an
,
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
-4 TRINEIERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated
compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
3. REFERENCES:
gatim Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-132453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FEC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
&
4.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire&are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshirer"are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration TruDefinitiona Duration Duration' Premium Cool, TruDefinition& Duration* Designer Color
Collection,TruDefinitionoOakridge Oakridge" and WeatherGuard& HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip&Ridge Shingles:
4.2.1 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard&HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidgel Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 Accessory Starter Strips:
4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS
Certificate of Authorisation#9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 2 of 8
• -- i
J
am T I-FY ERD
5.4 Wind Classification:
5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable
for use in all wind zones up to Vasd = 150 mph (V„it = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All Owens Corning hip &•ridge-shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for use in all wind zones up to Vasd=150 mph (Milt=194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean
roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 UnderfaVment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or 11905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,.with the following
exceptions:
b Berkshire shingles require minimum five(5)nails per shingle.
➢ WeatherGuard®HP shingles require minimum six(6)nails per shingle.
➢ Devonshire'""shingles require minimum six(6)nails per shingle.
> Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 MinimumNailing—StarterStripShingleandStarterStripPlus:
FeltunderlaYment Deck Feftunderla ment irk. Desk Sdf-adhered
- Y WeatherLock,
x Self•adhered •, undodaymerd
=rr WeatherLock's ",l,-•
1((c_; �underlsymeni �`=
_ Drip edge
Dnp 1. Drip edge Drip—
edge '
edgt edge
't•
-Nails located halt located
•?' 2'-3'from cave
"y
2"_3'from cave f
Install first Self-sealing adhesive Self-sung adhesive
StartetSttipp pasitionedalong eave Ensta9firn5tarterstrip Plus
Positioned dong eave
shinglev,itlt r tvhhFremeved \
6"removed r ,
Starter Strip shingle overhangs eaves and rakes h=:P StarterStrip Plus overhangs caves and rakes 1/4-314'
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8
Certificate of Autharl:ation#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 3 of 9
RI
TINTY ERR
6.2.6 Minimum Nailing—Classic®&Supreme:
Normal Mansard or Aroa para Normal Mansard orArea pora
Wind Areas High Wind desvad=nes v Wind Areas High Wind =ames v
Area porn vientas.normeles Areas vientos fuertes Area para viatttos normales Areas vientos fuertes
FT' 2~ SB t r r, (A)-- t.., rt. Z.. -(Bl
721 ` --121
6"Exposure 6 6/8"Exposure
Exposicidn Euposieion
6.2.7 Minimum Nailing—Berkshire®:
Sealant strip Sealant strip
La tira de sdlador La tirade sellador
a F--P a 9 *-*-a
V . B Y4"
r
0
Standard Fastening Pattern 6-Nail Fastening Pattern
Salam ship ,
f La}ira de c�ladar
t
t -
0
b�vv
2" Asphalt rooting cement
Comoro do tocho do astalto
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS
Certificate 4Authariration 1/9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 4 of 8
` TRINITYiERD
6.2.8 Minimum Nailing—Devonshire':
clam
Nails
5.5/8"exposure x, I_--= ---=L __•--�,= --,` ,
Sealant location
Exposid6n de 5.518 pulg
U6icaci6n del sellador
Ten t"Spots of Asphalt Roof Cement
Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition®
Duration Designer Color Collection:
4-Nail Fastening Pattern 6-Nall Fastening Pattern
SureNan�tastemrry area aidat SureNaiW fauerung ares width
Nall 7yp1eal N2147ypical
�7 F]
I � I
-
p'wacaoyl6 .. .'.O- +M�.S hf -- M.l^a1�i taJ�—•:3' ....®" - L.� 9-: 6:+e t . '-•
Standard Fastening Pattern 11 6-Nail Fastening Pattern
Fastening for Slopes Greater Than 21:12
SwoN�gB
.1.g--1=
r nau,swc1
I
8.118"I Sin T7T
11 ��
Four t"spins of mptart Raahpg Cement
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS
Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 5 of 8
• .2 _.TRINITY .E
RD
a
6.2.1 Minimum Nailing—TruDefinition Oakridge®,Oakridge®:
4 all PattAin 6 Nail Pattern
£squema can 4 clavas Esquema con 8 clavos
r r
r r
ice— 12 —�I 14-
5 5/8
4—
5618 Exposure Nails 56?8"Eaposule 641ls
aposic161?de 55/8 ping. Clavas £xposicldn de 55/8 ping. 5 518"Exposure Clans 5 618"Expm-we
Etpadd6a d6 5518 ping. £xpoSM611 de 55/8 pulg.
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Slopes Greater Than 21:12-
suroH,itl W or inq nr.,width
Ha I Typt d
8•tln` 17 F7
Four t"Spots o1Aspha[Rooting taetnont
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuard®HP:
7® 9 �re gods VbW
r—
�, r T*wv%aril Lkw
isAhmdo
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certificate ofAuthorizatlon 99503 6'H EDITION(2017)F13C NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 6 of 8
I 9 E ILA
6_3 Hip&Ridge Shingles:
® a
6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard HP Hip and Ridge Shingles
and ProEdge Flip & Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of DuraRidgell Hip & Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistance and installation limitations, including the use of hand-sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge:
Fig.1 4 Fig.2
IN��gwnN /�`� (�, A roliviem sidebiem
MIS \�� A Mals 1 nails1. 1I7 i
/`0Q "Ne's1 Topiaminated 116
plece
, Y
I I l
I l I I I
2-11\, 1 ��
4
6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge:
Fig A 44 Fig.'C Hip&Ridge Shingle Fastening
Prevalling VIM f.�� �. TOp'Jk'W
4-Dlrcstbn
Nolls q o \ham
\ NnlLs Nulls
/ �` � I � i I t� i P•
O` I I i � ,••i
Ezpo'curo
511 Exposure
_I
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS
Certificate of Authorization#9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 7 of 8
A>.
I EPS
6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Prevailiing Standard t1„�
Wind DirectionFastening
Sealant Scrip Pattern
6°Exposure
I
I } Sealant
Fasten 7112” 7 s/:"
6"Exposure
Cover Exposed
Fasteners with
Roof Cement I 12"
6.3.6 Minimum Nailing—DuraRidgeT"Hip&Ridge Shingles:
Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
Wi
Prasaiia rd Diradssi Top View
Diroaiond=ir.3nza&jvwE 1"i'Ealau
Dirordondal ri�nwpredxninsnco II- m.supericr 1-`-01
4�1 II cb
,rr�, 211Cik _ so"
Na _ `� �4 u^ 6rr:nsConun§.°.ssr t-0al. caw
44l0tre
i
rtL�+a V i
�lmprB r �
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(631)546-2458;Kanchi.Agrawala-Dokania@ul.com
END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS
Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 8 of 8