Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval-Door
2/12/20,19: Florida Building Code Online �., . COW:. •�' �' ' Fat ` iR4Ai�4PAttNTGP'a � u t es5 l&frOfessiortalY R °gut y I9 ;, � s ' '" ratillkOzet 0.40.baPftcrg tYllott `A r BCIS Home ( Log In ' User Registration 1 Hot Topics 1 Submit Surcharge 1 Stats @ Facts 1 Publications ( Contact Us BCIS Site Map ; Links ' F�011t�3 4,7guptifkilifjoval RECEIVED Product Approval Menu>Product or Application Search>Application List>Application Detail FEB 1 2 2019 t tC FL# � FL20470-R1 Permitting DepartMent Application Type .—. St. LuEI@ County Code Version 2017 Application Status Approved >ave_ rg' Comments Archived Product Manufacturer Therma-Tru Corporation I Address/Phone/Email 118 Industrial Drive Q • W Edgerton;OH 43517 . I� (419) 298-1740 rickw©rwbldgconsultants.com o� r �e Authorized Signature Vivian Wright , L' rickw@rwbldgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed F Professional Engineer u} Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Lyndon F. Schmidt, P.E. Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2020 Validated By Ryan J. King, P.E. Validation Checklist-Hardcopy Received Certificate of Independence FL20470 R1 COI (b)Certificate of Indeoendence.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D1929 1996 ASTM D2843 1999 ASTM D635 2003 ASTM D638 1996 ASTM E1300 2004 ASTM E84 2000 ASTM G26 1995 ASTM G7 1997 https://www.floridebuilding,org/pr/pr app_dtLaspx7param=wGEVXQwtDgsJ9a49YAgXJuu9%2fp88zxka9rWOzxE1e2Y1MMLGdCkEKQ%3d%3d 1/6 2/12/20,&9= Florida Building Code Online 20470.5 j e.Therma-Tru Fiber-Classic and Nominal 8'0"Impact" Opaque Composite Edge Fiberglass Smooth-Star Door with Sidelite(s) (Inswing/Outswing; XO,OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL20470 R1 II (b) Inst 20470.5.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 20470.5 for Design Pressure Ratings,any FL20470 R1 AE (b) Eval 20470.5.pdf additional use limitations,installation instructions and product FL20470 R1 AE (b)TT Plastics.2.pdf particulars. Created by Independent Third Party: Yes 20470.6 f.Therma-Tru Fiber-Classic and Nominal 8'0"Impact"Opaque Composite Edge Fiberglass Smooth-Star Double Door with or without Sidelites(Inswing/Outswing; OXXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL20470 R1 II (b) Inst 20470.6.p f Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 20470.6 for Design Pressure Ratings, any FL20470 R1 AE (b) Eval 20470.6.pdf additional use limitations, installation instructions and product FL20470 R1 AE (b)TT Plastics.2.pdf particulars. Created by Independent Third Party: Yes 20470.7 g.Therma-Tru Fiber-Classic and Nominal 6'8"Impact"Glazed Composite Edge Fiberglass Smooth-Star Door(Inswing/Outswing;X configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL20470 R1 II (b) Inst 20470.7.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20470.7 for Design Pressure Ratings,any FL20470 R1 AE (b) Eval 20470.7.pdf additional use limitations, installation instructions and product FL20470 R1 AE (b)TT Plastics.2.l particulars. Created by Independent Third Party: Yes 20470.8 h.Therma-Tru Fiber-Classic and Nominal 6'8"Impact"Glazed Composite Edge Fiberglass: Smooth-Star Door with Sidelite(s) (Inswing/Outswing;XO, OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL20470 R1 II (b)Inst 20470.8.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20470.8 for Design Pressure Ratings,any FL20470 R1 AE (b) Eval 20470.8.0f additional use limitations, installation instructions and product FL20470 R1 AE (b)TT Plastics.2.pdf particulars. Created by Independent Third Party: Yes 20470.9 i.Therma-Tru Fiber-Classic and Nominal 6'8"Impact"Glazed Composite Edge Fiberglass Smooth-Star Door with or without Sidelites(Inswing/Outswing; XX or 1 configurations) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL20470 R1 II (b) Inst 20470.9.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 20470.9 for Design Pressure Ratings,any FL20470 R1 AE (b) Eval 20470.9.odf additional use limitations, installation instructions and product FL20470 R1 AE (b)TT Plastics,2.pdf particulars. Created by Independent Third Party: Yes 20470.10 j.Therma-Tru Fiber-Classic and Nominal 8'0"Impact"Glazed Composite Edge Fiberglass Smooth-Star Door(Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL20470 R1 II (b)Inst 20470.10.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 20470.10 for Design Pressure Ratings,any FL20470 R1 AE (b) Eval 20470.10.odf additional use limitations, installation instructions and product FL20470 R1 AE (b)TT Plastics.2.pdf particulars. Created by Independent Third Party: Yes 20470.11 k.Therma-Tru Fiber-Classic and Nominal 8'0"Impact" Glazed Composite Edge Fiberglass Smooth-Star Door with Sidelite(s) (Inswing/Outswing;XO, OX or OXO configurations) https://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJuu9%2fp88zxka9rWOzxE1e2Y1MMLGdCkEKQ%3d%3d 3/6 4 R:10ients\Thenna Tru PERMANENT A Florida Product APprovaI51FL-20470 HVHZ 1T-Composite\C-Drawings\FL-20470(2017)18-20470.7-94w0,103 05 0 g®�1. � 3 fmi. W 00 1 I I I.. I • • 0000 Vi X >� i- I. I I I c 14"MAX. I I 6.PP)� -il o K5,- 00 rn , I ..1'.•1:1 310 - 1,-.1' 1 _.I I. 1_ I -1 o _ z 2C3 0 1 1 1 `- L I = 1 —I 00 GI O _ r= - _±.1. oN2-;)—Tri) {nn og N 1. 1 —{ E G2 1,3 NnI •F V•.•�VCEN$�'•.J` f1.7. 14 MAX I / L 0.C.(TYP.) 6'(TYP.)--.4 �-- G No.43409 '7 2t!�7 is $ 9 - - _ PRODUCT: Documenb Prapoled BY: � •, BTREOF . tr THERM.4—TRU Lyndon.F.Schmidt i P,.. 7 ice- U:U. �.h••• ;ORID.. • I° o i. o FlBERG DOOR P.E.P.e'No. aa4o9 'i7,40r4AL 0,\•`' I° -1, ,_ y is,0 _ PART OR ASSEMBLY: ///�� BUILDING"CONSULTANTS, 114x' I p x i0' 1 7/14/17 UPDATE TO 6TH ED. (2017) FBC JK V U P.O. Box 230, VDINeo; Ft 33595 - ro 01 N0 DATE BY FRAME ANCHORING Phone No.: 813.659.9197 REVISIONS FIBRE.CA No. 9813 O 201 6 R.W.BUILDING CONSULTANTS INC. BILL OF MATERIALS. BILL'OF MATERIALS ? 'V ITEM# DESCRIPTION MATERIAL REM 0 DESCRIPTION. MATERIAL s r:t o' Es j= A 1X BUCK(SG>=0.42) WOOD 25. #8 x 2-1/2"PFH WOOD SCREW STEEL. -y .. . : 2.;rln B 2X BUCK(SG>=0.42) WOOD 26 #8x5/8' PFH WOOD SCREW STEEL .v.A. 1_4%i.:• °' C 1/4"MAX.SHIM SPACE - 27 LATCH STRIKE PLATE STEEL �'�i>�''••:. '''k 1 9" D 1/4"X 2-3/4"PFH ELCO OR I1W CONCRETE SCREW STEEL 28'. DEADBOLT STRIKE PLATE. STEEL ..iq� •..p\ps.$ g>M m E. MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI CONCRETE 29 4"X 4"HINGE STEEL I f T�: , -. 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 . . 32. INSWING THRESHOLD ALUM/COMP � \�.`.Is- . - Z d G 3/16"X 3-1/4"ITW CONCRETE SCREW STEEL 33 INSWING THRESHOLD ALUM/COMP ,(` $ og� 9 m o a I 1/4"X 1-3/4"PFH ELCO OR 11W CONCRETE SCREW STEEL 34 INSWING THRESHOLD ALUM/COMPow 'S"� 'm oa`a J 1/4"X 3-3/4"PFH ELCO OR ITW CONCRETE SCREW. STEEL .. 35 INSWING THRESHOLD. ALUM/COMP 4 0 L #10 X 2-1/7'PFH WOOD SCREW(1.15'MIN.EMBEDMENT) STEEL 36 INSWING THRESHOLD. ALUM/COMP ggE 9 z k M 3/16"X 2-1/4"ITW CONCRETE SCREW STEEL 37 INSWING THRESHOLD ALUM/COMP g ��a N 3/16"X 2-3/4"ITW CONCRETE SCREW STEEL 38 INSWING THRESHOLD ALUM/COMP rr., P 1/4"X 2-3/4"PFH ELCO CONCRETE SCREW STEEL 39 INSWING THRESHOLD ALUM/COMP 1 . JAMB(FINGER JOINT PINE) WOOD 40 DOOR PANEL(BOOK) • 6 WEATHERSTRIP(MEDIUM REACH) FOAM 41 DOOR PANEL(HYBRID) - �o E 7 WEATHERSTRIP(LONG REACH) FOAM 42 DOOR PANEL(U.1) � J d 8 SWEEP VINYL 50 SIDELITE - m 4 9 SWEEP(USE W/MODERATE CLIMATE THRESHOLD) VINYL 75 SIDELITE SPACER(INSWING) PVC " g 10 SWEEP(USE W/PUBLIC ACCESS THRESHOLD) . VINYL 76 SIDELITE SPACER(OUTSWING) PVC . m m ry . 11 #10 X 1-3/4"PFH WOOD SCREW . . . STEEL 77 . SIDELITE SPACER(INSWING)-MODERATE CLIMATE SILL. . PVC 'o a 15 PUBLIC ACCESS THRESHOLD ALUM 78 MULTIPOINT LOCK STRIKE PLATE Col HEAD STEEL a Wd - 16 OUTSWING THRESHOLD .ALUM/COMP 79 MULTIPOINT LOCK STRIKE PLATE©SILL STEEL 17 OUTSWING THRESHOLD ALUM/COMP . 80. ASTRAGAL STRIKE PLATE . STEEL. 'm 18 OUTSWING THRESHOLD ALUM/COMP 88. 2X MULLION(SG>=0.55) WOOD 0 k 19 COASTAL OUTSWING THRESHOLD ALUM/WOOD 8 20 . COASTAL ALUMINUM ASTRAGAL ALUM N 23 #10x3/4"PFH WOOD SCREW STEEL cn TE ANCHOR NOTES: 24 #10x.1"PFHWOODSCREW STEEL CONCREn g �£ 1:Concrete anchor locations at the comers maybe adjusfedtto maintain the min. � R edge distance to mortar joints. S 2.Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to .c maintain the min.edge distance to mortar joints,additional concrete anchors may be required to ensure the"MAX.ON CENTER"dimension are not exceeded. .. e 3.Concrete anchor table c) ANCHOR-. NCHO 1 MIN CLEARANCE MIN CLEARANCE k 2 A A M 70 MASONRY TO ADJACENT w TYPE .SIZE EMBEDMENT -_v r E E N O TAP ON® 1/4" 1.1/4" 2" 4".IPN ^o n ULTRACONELCO ® 1/4". 1-114" 1" 4". wl 08/02/16 0 ITW ® `3/16" 1-1/4" AS SHOWN 1.1/2. . s N.T.S. 3 TAPCONe Br: . JK mm 2 WOOD SCREW INSTALLATION NOTES: ONE W: LFS 3 re 1.Maintain a minimum 5/e edge distance,1"end distance,&1" DRAWING NO.:o.c.spacing of 0 wood screws to prevent the splitting of wood. ' f1-20470.9 E a sew]4.or14 a _ r(.