Loading...
HomeMy WebLinkAboutRevisions OFFICE USE ONLY: DATE FILED: PERMIT# 1811-0381 REVISION FEE: RECEIPT# CA4-UP PLANNING& DEVELOPMENT SERVICES BUILDING&CODE REGULATION DIVISION 2300 VIRGINIA AVENUE -11 - FORT PIERCE, FL 34982 56, CA (772)462-1553 APPLICATION FOR BUILDING-PERMIII S R r PROJECT INFORMATION 11m itis fR LOCATION/SITE ADDRESS: 775 E Prima Vista Blvd p-T"? DETAILED DESCRIPTION OF PROJECT xv'. z" REVISIONS: Remove existing Master Flow Attic Fan Replacing w.new Master Flow attic fan A X- CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CCC1330918 ST. LUCIE CO CERT. BUSINESS NAME: Alliance Group QUALIFIERS NAME: Danielle Ryckman ADDRESS: 605 NW Enterprise Drive CITY: Port St. Lucie STATE: FL ZIP: 34986 PHONE(DAYTIME): 772-492-8006 FAX: 772-492-8008 OWNER/BUILDER INFORMATION: NAME: Transitions LLC ADDRESS:123 Queen Guinevere Ct CITY: Fort Pierce STATE: FL ZIP: 34949 PHONE (DAYTIME: FAX: ARCHITECT/ENGINEER INFORMATION: NAME: N/A ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME): FAX: L REO-1VEI) SLCCC.- 9123109 D Revised 06130117 JAN 3 0'2019 Permitting Department St. Lucie County, FL J AWOL PERMIT# � � p-� 1, ISSUE DATE PLANNING & DEVELOPMENT SERVIt Building & Code Compliance Divis oLEIVED • BUILDING PERMIT FEB 19 2019 SUB-CONTRACTOR AGREEMENT Permitting Department St. Lucie County, FL have agreed to be (Company Name/Individual Name) p the y/�Y�&4A— Sub-contractor for �,(",�,,{ *IJ(g &P-0 (.� (Type of Trade) (Primary Contractor) For the project located at 7fIDI-1 m 4 V/S 7-A t3 L L `��J" (Project Street Address or Property Tax ID#) It is understood that, if there is any change of status regarding our participation with the above mentioned project, the Building and Code Regulation Division of St. Lucie County will be advised pursuant to the filing of a Change of Sub-contractor notice. CONT CTOR SIGNA E(Qualifier) SUB-CONTRACTOR SIGN&URE(Qualifier) ' �s7n�Cie rem i Gt- ��• ( 11°�'7 i��171 (��i"�-J�-I i Q- � i' PRINT NAME PRINT NAME q / COUNTY CERTIFICATION NUMBER COUNTY CER/7TIF�If/CATION NUMBER State of Florida,County of S4—.A.uoe— State of Florida,County of _:5T1. Luuc— The foregoing instrument was signed before me this (5 day of The foregoing instrument was signed before me this day of 2019,by��hnlL ���f`�j2 . /► bYe�af ,20fi,by e f)C Cere R 4rte- who is personally known or has produced a who is personally known or has produced a as identification. as identification. STAMP STAMP Signature of Notary Public Signature of Notary Public Print Name of Notary Public Print Name of Notary Public us- MILDAEDBARBOSA NotaryPublic-StateofFlorida Commission<GU 148903 MyComm,Expires Oct 5,2021 `�:` Bandedthrough NatlaealNataiyAm; Revised 11/16/2016 "" I , ;� :.f ✓,q R�Q11k, O n �y St let /1) 1p,9 Co rt MIAMI OADP �v:�'k;a r i y=� 3':% I!--: MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 -r(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) "i4-x,•-mi.iroidade.Lo,•/cconomv GAFF 1 Campus Drive 4,JIf � �, � �+ '^i ` E•. Parsippany,NJ 07054 Y� �1 :.,x.11 �•� � ;� G;�'�-h' i'�i SCOPE' :.,� ,; ;'/ F ;I♦Fy u / This NOA is being issued under the applicable rules and regulations governing the use of construction mai rials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this tial fails o perform in the accepted product or material tested for quality assurance purposes. If this product or mate t p p A manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Master Flow°Power Attic Vent—ERV4 Roof Mount GAF Master Flow'`-'Power Attic Vent—ERV5 Roof Mount GAF Master Flow'Power Attic Vent—ERV6 Roof Mount GAF Master Flow®Attic Exhaust Vent High-Capacity Dome Vent HCD144 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety.. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No.15-0218.04 and consists of pages 1 through 4. The submitted documentation was reviewed by Gaspar J Rodriguez. NOA No.: 16-0209.11 QMW1AMWDADEC=0UNTY—51 Expiration Date: 09/24/20 Approval Date:05/05/16 Page 1 of 4 I s ROOFING COMPONENT APPROVAL Category: Roofing Sub-Category: Ventilation Material: Galvanized Steel Minimum Slope: 2:12 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT Product Dimensions Test Product Specification Description GAF Master Flow' Power Attic Vent— Height=8.00" Powered Roof Vent,with fan and ERV4 Roof Mount Length&Width=25" TAS 100 thermostat with a galvanized hood. 0.020" Thick Gavlanized Steel GAF Master Flow`s 00"=8 h igt . Power Attic Vent— HePowered Roof Vent,with fan and ERV5 Roof Mount Length&Width=25" TAS 100 thermostat with a galvanized hood. 0.020"Thick Gavlanized Steel 'GAF Master-Flow' Power.Attic Vent— Height=-8.00"- Powered-Roof Vent with-fan and Length.&Width 25" TAS 100 ' ERV6 Roof:Moiint -.thelnnostatwith,a galvanized_hood. 0:020"'ThickGavlanizdd Steel. -- GAF Master Flow Attic Exhaust Vent Height=8.00" Static Roof Vent,with a galvanized High-Capacity Dome Length&Width=25 TAS 100 food. Vent HCD144 0.020"Thick Gavlanized Steel MANUFACTURING LOCATION 1. Burgaw,NC EVIDENCE SUBMITTED Test Agency Test Name/Report Test Identifier Date PRI Construction Materials Technologies TAS 100(A) LLB-027-02-01 01/29/16 NOA No.: 16-0209.11 MIAMI-DADE COUNTY Expiration Date: 09/24/20 �- Approval Date:05/05/16 Page 2 of 4 I I i • s APPROVED APPLICATIONS Tradename: GAF Master Flow"Power Attic Vent—ERV4 Roof Mount,Power Attic Vent—ERV5 Roof Mount,Power Attic Vent—ERV6 Roof Mount and GAF Master Flow'Attic Exhaust Vent High- Capacity Dome Vent HCD144. System Type: Mechanical attachment of powered or static vent under asphalt shingle roof systems. Cutout: Vent must be located 18-inches from ridgeline. At chosen location and centered between two roof rafters,cut a 15-inch diameter hole through shingles and sheathing boards. Using marked position as center point,scribe a circle that is the same diameter as the vent throat opening. Starting with the drill hole,cut vent hole. Installation: Vents should be evenly spaced on the rear slope of the roof. Remove roofing nails from top row of shingles so the flashing of the roof vent will slide under shingles. Apply approved roof cement around the edge of the hole and approved roof sealant on underside of the base unit flange,with two 1/2-inch beads of approved sealant;with the first bead 3/4-inch from the throat and the second placed'/4-inch from outside perimeter. Carefully slide base of vent under shingles with arrow facing up. Make sure the throat of the vent is centered over vent hole. Fasten the base to roof decking at corners,and approx. 5.75-inch on center 1-inch from the outside edge of the flange and 1-inch from stack every 900 with approved roofing nails,keeping heads of nails under shingles where possible. Use a minimum of 20 nails that shall be of sufficient length to penetrate through roof sheathing a minimum of/z". See detail drawings herein. Seal all seams and nails with roofing cement. Net Free Area: Refer to manufacturers published literature. GENERAL LIMITATIONS 1. Refer to applicable Building Code required ventilation. 2. For GAF Master Flow' Power Attic Vent— ERV4 Roof Mount, Power Attic Vent—ERV5 Roof Mount, and Power Attic Vent — ERV6 Roof Mount, thermostat and wiring shall be installed in compliance with GAF's published instructions,and in accordance with applicable Building Codes. 3. This acceptance is for installations under asphaltic shingle roof systems only. 4. GAF Master FlowQD Power Attic Vent—ERV4 Roof Mount,Power Attic Vent—ERV5 Roof Mount,Power Attic Vent—ERV6 Roof Mount and GAF Master Flow Attic Exhaust Vent High-Capacity Dome Vent.HCD144 shall not be installed on roof mean heights greater than 33 feet. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 6. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miarni-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. CMIAMII-DADE COUNTY NOA No.: 16-0209.11 MIAMI•DADECOUNTY Expiration Date:09/24/20 Approval Date:05/05/16 Page 3 of 4 r DETAIL DRAWINGS GAF MASTER FLOW®Power Attic Vent—ERV4 Roof Mount,Power Attic Vent—ERV5 Roof Mount, Power Attic Vent—ERV6 Roof Mount and GAF Master Flow®Attic Exhaust Vent High-Capacity Dome Vent HCD144 f 1� (All dimensions in inches) END OF THIS ACCEPTANCE NOA No.: 16-0309:11 MIAMI•DADECOUNTY Expiration Date: 09/24/20 �F'uwuvj Approval Date:05/05/16 Page 4 of 4