Loading...
HomeMy WebLinkAboutCCE02252019_00000All APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: FEBRUARY 25, 2019 Permit Number: Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential X PERMITTYPE:HVAC/ MECHANICAL PROPOSED IMPROVEMENT LOCATION: Address: 3042 NW RADCLIFFE WAY, PALM CITY, FL 34990 Property Tax ID #: 4425-703-0017-000-7 Site Plan Name: Project Name: JAMES COVEY Lot No. 12 Block No. DETAILED DESCRIPTION OF WORK: INSTALL 1 - 24000 BTU DUCTLESS MITSUBISHI MINI -SPLIT INCLUDING OUTDOOR CONDENSING UNIT AND INSIDE HEADS, NO DUCTWORKI CONSTRUCTION INFORMATION: Additional work to be performed under this permit—check all that apply: _Mechanical _Gas Tank _Gas Piping _Shutters Electric _ Plumbing _ Sprinklers Total Sq. Ft of Construction: 1050 Cost of Construction: $ 6500 _ Generator Sq. Ft. of First Floor: Windows/Doors Roof Pitch Utilities: _Sewer _Septic Building Height: OWNER/LESSEE: CONTRACTOR: Name JAMES COVEY Name: NEESE ENTERPRISES INC. Address: 3042 NW RADCLIFFE WAY Company: QUALITY A/C & HEATING OF Address: 5351 SW 16TH AVE City: OKEECHOBEE OKEECHOBEE City: PALM CITY State: _JI Zip Code: 34990 Fax: Phone No. 8634671545 State: FL 34670696 Zip Code: 34974 Fax: 8E Phone No 8634671545 E -Mail lauraaltman@embargmail.com E -Mail: Fill in fee simple Title Holder on next page ( if different from the Owner listed above) State or County License CACO29420 If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. It value of HVAC IS $7,suu or more, a RECORDED Notice of Commencement Is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: _ Not Applicable Name: MORTGAGE COMPANY: _Not Name: Address: City: Applicable Address: City: State: Zip: Phone State: Zip: Phone: FEE SIMPLE TITLE HOLDER: _ Not Applicable Name: BONDING COMPANY: _ Name: of Applicable Address: Address: City: City: Zip: Phone: Zip: Phone: OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and in itallation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build thesubject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform I he work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additi ns, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non,idential use "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RES U T IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Signature of Owner/ essee/ ontractor as Agent for Owner Signature STATE OF FLORIDA COUNTY OF OKEECHOBEE The forgoing instrument was acknowledged before me this 25 day of FEBRUARY 20-H by STATE OF FLORIDA COUNTY OF The forgoing instrument was acknowledge befc this251dayofQkx%AQ20-r 0 by SAMUEL G. NEESE III Name of person making statement. Name of person making statement. Personally Known x Type of Identification Commission No. GG 123172 OR Produced Identification Personally Known -X--- OR Produced Type of Identification REVIEWS FRONT COUNTER a LAURA JEAN ALiM Yu re of Notary Public- State of Flori • 4 MY COMMISSIONMGG12112 "rs eal)ExPIRES:July11,202 `o fission No.GCn alfa- ,tiy"; , 9ordM lhru NotaryPuDk Urde r R ZONING SUPERVISOR PLANS VEGETATION SEA REVIEW REVIEW I REVIEW REVIEW I REVIEW me MY COMMISSION p REVIEW 2. SPECIFICATIONS 2-1. OUTDOOR UNIT MXZ-3C24NA2 Item Test Outdoor model Out or air condition Dry bulb Wet bulb MXZ-3C24NA2 '1: "A" Cooling steady state at rated compressorspeed 80 67 Indoor pe Non -Duct 06+09+09 Duct (09+)9+09) "B-2" Cooling steady state at rated compressor speed Cooling '1 Btu/h 22,000 (65) 23,6(0 Capacity Heating 47 *1 Btu/h 25,000 (65) 24,6 0 Low ambient cooling steady state at minimum compressor speed Heating 17 -2 Btu/h 19,600 53.5) 19,6(6-- 9,6 0Power Power Cooling *1 W 1,620 (69) 210 consumption Heating 47 '1 W 1,750 43 1,90 *2: Low temperature heating at maximum compressor speed Heating 17 '2 W 2,580 15 2,44 EER Cooling 60 13.6 56.5 11. SEER Coolin 60 20.0 43 16 HSPF IV V Heating9.8 60 7.6 8 (7. _ 33 9.2 7 6 COP Heating 60 3 33 3.8 6cternal finish Munsell 3.6Y 7.8/1.1 Powersupply V, phase, Hz 208/230, 1, 60 MAXIMUM fuse size time dela A 25 Min. circuit ampacity A 22.1 Fan motor FLA 2.43 Model SNB220FQGMC Winding resistance Compressor (at 68 °F) U -V 0.95 V -W 0.95 W -U 0.95 R.L.A 12 L.R.A 13.7 Refrigerant control LEV Sound level dB(A) 51/55 Defrost method Reverse cycle W in. 37-13132 Dimensions I D in. 13 H in. 31-11/32 Weight Ib. 137 Remote controller Wireless type Control voltage (by built-in transformer 12-24 VDC Refrigerant piping Not supplied (optional arts Valve size Liquid in, 1/4 Gas in. A: 1/2 B,C: 3/8 Connection method Indoor Flared Outdoor Flared Refrigerant charge (R410A) Ib. 6 lb. 13 oz. Refrigeration oil Model fl oz. L 23.7 0.7 FV503 NOTE : Test conditions are based on ARI 210/240. Unit: 'F Mode Test Indoor air condition Dry bulb Wet bulb Out or air condition Dry bulb Wet bulb Cooling '1: "A" Cooling steady state at rated compressorspeed 80 67 9 75 "B-2" Cooling steady state at rated compressor speed 80 67 8 (65) "B-1" Cooling steady state at minimum compressor speed 80 67 8 (65) Low ambient cooling steady state at minimum compressor speed 80 67 6 53.5) Intermediate cooling steady state at intermediate compressor speed 80 67 8 (69) Heating *1: Standard rating -heating at rated compressor speed 70 60 4 43 *2: Low temperature heating at maximum compressor speed 70 60 1 15 Maximum temperature heating at minimum compressor speed 70 60 6 56.5 High temperature heating at minimum compressor speed 70 60 4 43 Frost accumulation at rated compressor speed 70 60 3 _ 33 Frost accumulation at intermediate compressor speed 70 60 3 33 Due to continuing improvement, above specification may be subject to chanoe without notice. M -Series Multi -Zone MXZ-3C24-3030-4C36-5C42NA2_MXZ-2020-3024-3C30NAHZ2(September201 IMTSUBISM ELECI MXZ-C2-2 02016 Single Zona I SLZ Heat Pump I o4 2� • NOTES: Test conditions are based on AHRI 2101240. Capacity Range BtWh '4. Indoor units receive power from outdoor units through field -supplied intercunnected wiring. ,., 00 150 47-F (8 Cit, WB. is -F(6- C)I LIMITED WARRANTY I Seven-year warranty on compressor. Five-year warranty on parts. -3. Rating corditions(heating)-mcooc D.E.70' F (21-C)i W.B. 60' F (Iso C); Outdoor. D.B. 3,10-73,300 17° F (-8" C), W.B. 15- F (9° C). 3,800-17,700 Cooling '1 Total Input W 920 EnergyEfficienc SEER 1,460 Moisture Removal Pints/h 154 16 Heat Factor M1.2 2.3 2.3 4.5Sensible 4.5Rated Capacity Btu/h Capac'Ty Range ,600 18,000 Heating at 47°F-2 Blu/h 3,117,100 3122000Total Input W HSPF Btu/h/W ,180 9.6 1,950 Rated Capacity Bluth 6,200 Heating at 17' F'3 Rated Total Input W 8,300 10,200 Maximum Capacity BIWh 740 930 1,310 Power Supply Phase, CYcle, Voltage 6.21 8,300 12,000 1 Phase, 501-1z, 208 / 230V -4 Voltage Indoor -Outdoor S7 - S2 AC Indoor -Outdoor 52 - 33 208-230V DC 12-24V MCA A Fan Motor F.LA. 0.23���-280-320-390 0.28 Airflow at Cooling/Heating (Lo-Med-H) DRY (CFM) 280320350 WET(CFM 250-290-320250290350 Sound Pressure Level dB 29-32-38 3034-39 31-35-40 Indoor Unit EIdennal Finish Galvanized -Steel Sheets; Grille: Munsell 6.4 8.9/0.4 W: In. 22-7/16 (25-5/8) Dimension Unit (Grille) D:In. 22-7/16 25-5/8 H: In. 9-1/4(73/16) Wel ht Unil Grille Lbs. 36 Drain-litt Mechanism ndutl H: In. 19-11716 Field Drainpipe Size O.D. In. 1-t//1 Remote Controller Type Selectfrom MHKI(Preferred).PA8-21MA, or PAR-FL/FA32 R1 mote Controllers MCA A 12 MOCP A 15 Fan Motor RLA 0.50 Model (Type) DC INVERTER-drwn DC INVERTER -driven Twin Compressor RLARot 6.6 7.4 LRA. B.2 9.3 Aidlow(Cooling/Heating) CFM 1,151/1,225 1,229/1,172 1,293/1,228 Outdoor Unit Refrigerant Control Linear Expansion Valve Defrost Method Reverse cycle Sound Pressure Level at Cooling '1 dB(A) 46 49 Sound Pressure Level at Heating '2 dB(A) 50 51 Fxtemal Finish Calor Munsell No. 3Y 7.8/1.1 W: In. 31-1/2 D:In. 11-1/4 Dimensions H: In. 21-5/8 Weight Lbs. 66 77 80 52e R41 OA Refrigerant Charge Lbs., Oz. 2 2,9 Oil I Type Ill. oz. NE022 10.8 NE022 15.2 Refrigerant Pipe Gas Side O.D. In. 3/8 1/2 Liquid Side O.D. i In. 1/4 Refrigerant Pipe Length Height Difference (Max.) Ft. 40 Length (Max.) FL 65 Connection Method Indoor/Outdoor Flared/Hared NOTES: Test conditions are based on AHRI 2101240. `1: Rating conditions (cooling) -Indoor. D.R. 80' F (27" C), W B 8P F(Igo .C);. Outdoor: 0.6. '4. Indoor units receive power from outdoor units through field -supplied intercunnected wiring. 95 F (35'. C). WE. 75" F (24` Q. -2. Rating conditions (heat ng) Indoor: D.B. 70' F (21- C), W.R. 6W F(16 -C); Outdoor D.B. SpecitmaWns are subject to change without notice. 47-F (8 Cit, WB. is -F(6- C)I LIMITED WARRANTY I Seven-year warranty on compressor. Five-year warranty on parts. -3. Rating corditions(heating)-mcooc D.E.70' F (21-C)i W.B. 60' F (Iso C); Outdoor. D.B. 17° F (-8" C), W.B. 15- F (9° C). 28 / MITSUBfSHI ELECTRIC / M -SERIES / SPECIFICATIONS