HomeMy WebLinkAboutCCE02252019_00000All APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: FEBRUARY 25, 2019 Permit Number:
Building Permit Application
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential X
PERMITTYPE:HVAC/ MECHANICAL
PROPOSED IMPROVEMENT LOCATION:
Address: 3042 NW RADCLIFFE WAY, PALM CITY, FL 34990
Property Tax ID #: 4425-703-0017-000-7
Site Plan Name:
Project Name: JAMES COVEY
Lot No. 12
Block No.
DETAILED DESCRIPTION OF WORK:
INSTALL 1 - 24000 BTU DUCTLESS MITSUBISHI MINI -SPLIT INCLUDING OUTDOOR CONDENSING UNIT AND INSIDE
HEADS, NO DUCTWORKI
CONSTRUCTION INFORMATION:
Additional work to be performed under this permit—check all that apply:
_Mechanical _Gas Tank _Gas Piping _Shutters
Electric _ Plumbing _ Sprinklers
Total Sq. Ft of Construction: 1050
Cost of Construction: $ 6500
_ Generator
Sq. Ft. of First Floor:
Windows/Doors
Roof Pitch
Utilities: _Sewer _Septic Building Height:
OWNER/LESSEE:
CONTRACTOR:
Name JAMES COVEY
Name: NEESE ENTERPRISES INC.
Address: 3042 NW RADCLIFFE WAY
Company: QUALITY A/C & HEATING OF
Address: 5351 SW 16TH AVE
City: OKEECHOBEE
OKEECHOBEE
City: PALM CITY State: _JI
Zip Code: 34990 Fax:
Phone No. 8634671545
State: FL
34670696
Zip Code: 34974 Fax: 8E
Phone No 8634671545
E -Mail lauraaltman@embargmail.com
E -Mail:
Fill in fee simple Title Holder on next page ( if different
from the Owner listed above)
State or County License CACO29420
If value of construction is $2500 or more, a RECORDED Notice of Commencement is required.
It value of HVAC IS $7,suu or more, a RECORDED Notice of Commencement Is required.
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION:
DESIGNER/ENGINEER: _ Not Applicable
Name:
MORTGAGE COMPANY: _Not
Name:
Address:
City:
Applicable
Address:
City: State:
Zip: Phone
State:
Zip: Phone:
FEE SIMPLE TITLE HOLDER: _ Not Applicable
Name:
BONDING COMPANY: _
Name:
of Applicable
Address:
Address:
City:
City:
Zip: Phone:
Zip: Phone:
OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and in itallation as indicated.
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build thesubject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform I he work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additi ns,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non,idential use
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RES U T IN YOUR PAYING
TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND
POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT."
Signature of Owner/ essee/ ontractor as Agent for Owner Signature
STATE OF FLORIDA
COUNTY OF OKEECHOBEE
The forgoing instrument was acknowledged before me
this 25 day of FEBRUARY 20-H by
STATE OF FLORIDA
COUNTY OF
The forgoing instrument was acknowledge befc
this251dayofQkx%AQ20-r
0 by
SAMUEL G. NEESE III
Name of person making statement. Name of person making statement.
Personally Known x
Type of Identification
Commission No. GG 123172
OR Produced Identification Personally Known -X--- OR Produced
Type of Identification
REVIEWS FRONT
COUNTER
a LAURA JEAN ALiM Yu re of Notary Public- State of Flori
• 4 MY COMMISSIONMGG12112
"rs eal)ExPIRES:July11,202 `o fission No.GCn alfa- ,tiy";
, 9ordM lhru NotaryPuDk Urde r R
ZONING SUPERVISOR PLANS VEGETATION SEA
REVIEW REVIEW I REVIEW REVIEW I REVIEW
me
MY COMMISSION p
REVIEW
2. SPECIFICATIONS
2-1. OUTDOOR UNIT
MXZ-3C24NA2
Item
Test
Outdoor model
Out or air condition
Dry bulb Wet bulb
MXZ-3C24NA2
'1: "A" Cooling steady state at rated compressorspeed
80
67
Indoor pe
Non -Duct 06+09+09
Duct (09+)9+09)
"B-2" Cooling steady state at rated compressor speed
Cooling '1
Btu/h
22,000
(65)
23,6(0
Capacity
Heating 47 *1
Btu/h
25,000
(65)
24,6 0
Low ambient cooling steady state at minimum compressor speed
Heating 17 -2
Btu/h
19,600
53.5)
19,6(6--
9,6 0Power
Power
Cooling *1
W
1,620
(69)
210
consumption
Heating 47 '1
W
1,750
43
1,90
*2: Low temperature heating at maximum compressor speed
Heating 17 '2
W
2,580
15
2,44
EER
Cooling
60
13.6
56.5
11.
SEER
Coolin
60
20.0
43
16
HSPF IV V
Heating9.8
60
7.6
8 (7.
_
33
9.2 7 6
COP
Heating
60
3
33
3.8
6cternal finish
Munsell 3.6Y 7.8/1.1
Powersupply
V, phase, Hz
208/230, 1, 60
MAXIMUM fuse size time dela
A
25
Min. circuit ampacity
A
22.1
Fan motor
FLA
2.43
Model
SNB220FQGMC
Winding resistance
Compressor
(at 68 °F)
U -V 0.95 V -W 0.95 W -U
0.95
R.L.A
12
L.R.A
13.7
Refrigerant control
LEV
Sound level
dB(A)
51/55
Defrost method
Reverse cycle
W
in.
37-13132
Dimensions I
D
in.
13
H
in.
31-11/32
Weight
Ib.
137
Remote controller
Wireless type
Control voltage (by
built-in transformer
12-24 VDC
Refrigerant piping
Not supplied (optional arts
Valve size
Liquid
in,
1/4
Gas
in.
A: 1/2 B,C: 3/8
Connection method
Indoor
Flared
Outdoor
Flared
Refrigerant charge (R410A)
Ib.
6 lb. 13 oz.
Refrigeration oil Model
fl oz. L
23.7 0.7 FV503
NOTE : Test conditions are based on ARI 210/240. Unit: 'F
Mode
Test
Indoor air condition
Dry bulb Wet bulb
Out or air condition
Dry bulb Wet bulb
Cooling
'1: "A" Cooling steady state at rated compressorspeed
80
67
9
75
"B-2" Cooling steady state at rated compressor speed
80
67
8
(65)
"B-1" Cooling steady state at minimum compressor speed
80
67
8
(65)
Low ambient cooling steady state at minimum compressor speed
80
67
6
53.5)
Intermediate cooling steady state at intermediate compressor speed
80
67
8
(69)
Heating
*1: Standard rating -heating at rated compressor speed
70
60
4
43
*2: Low temperature heating at maximum compressor speed
70
60
1
15
Maximum temperature heating at minimum compressor speed
70
60
6
56.5
High temperature heating at minimum compressor speed
70
60
4
43
Frost accumulation at rated compressor speed
70
60
3
_
33
Frost accumulation at intermediate compressor speed
70
60
3
33
Due to continuing improvement, above specification may be subject to chanoe without notice.
M -Series Multi -Zone MXZ-3C24-3030-4C36-5C42NA2_MXZ-2020-3024-3C30NAHZ2(September201 IMTSUBISM ELECI
MXZ-C2-2
02016
Single Zona I SLZ Heat Pump I o4 2� •
NOTES: Test conditions are based on AHRI 2101240.
Capacity Range
BtWh
'4. Indoor units receive power from outdoor units through field -supplied intercunnected wiring.
,., 00
150
47-F (8 Cit, WB. is -F(6- C)I
LIMITED WARRANTY I Seven-year warranty on compressor. Five-year warranty on parts.
-3. Rating corditions(heating)-mcooc D.E.70' F (21-C)i W.B. 60' F (Iso C); Outdoor. D.B.
3,10-73,300
17° F (-8" C), W.B. 15- F (9° C).
3,800-17,700
Cooling '1
Total Input
W
920
EnergyEfficienc
SEER
1,460
Moisture Removal
Pints/h
154
16
Heat Factor
M1.2
2.3
2.3
4.5Sensible
4.5Rated
Capacity
Btu/h
Capac'Ty Range
,600
18,000
Heating at 47°F-2
Blu/h
3,117,100
3122000Total
Input
W
HSPF
Btu/h/W
,180
9.6
1,950
Rated Capacity
Bluth
6,200
Heating at 17' F'3
Rated Total Input
W
8,300
10,200
Maximum Capacity
BIWh
740
930
1,310
Power Supply
Phase, CYcle, Voltage
6.21
8,300
12,000
1 Phase, 501-1z, 208 / 230V -4
Voltage
Indoor -Outdoor S7 - S2
AC
Indoor -Outdoor 52 - 33
208-230V
DC 12-24V
MCA
A
Fan Motor
F.LA.
0.23���-280-320-390
0.28
Airflow at Cooling/Heating (Lo-Med-H)
DRY (CFM)
280320350
WET(CFM
250-290-320250290350
Sound Pressure Level
dB
29-32-38
3034-39
31-35-40
Indoor Unit
EIdennal Finish
Galvanized -Steel Sheets; Grille: Munsell 6.4 8.9/0.4
W: In.
22-7/16 (25-5/8)
Dimension Unit (Grille)
D:In.
22-7/16 25-5/8
H: In.
9-1/4(73/16)
Wel ht Unil Grille
Lbs.
36
Drain-litt Mechanism ndutl
H: In.
19-11716
Field Drainpipe Size O.D.
In.
1-t//1
Remote Controller
Type
Selectfrom MHKI(Preferred).PA8-21MA, or PAR-FL/FA32 R1 mote Controllers
MCA
A
12
MOCP
A
15
Fan Motor
RLA
0.50
Model (Type)
DC
INVERTER-drwn
DC INVERTER -driven Twin
Compressor
RLARot
6.6
7.4
LRA.
B.2
9.3
Aidlow(Cooling/Heating)
CFM
1,151/1,225
1,229/1,172
1,293/1,228
Outdoor Unit
Refrigerant Control
Linear Expansion Valve
Defrost Method
Reverse cycle
Sound Pressure Level at Cooling '1
dB(A)
46
49
Sound Pressure Level at Heating '2
dB(A)
50
51
Fxtemal Finish Calor
Munsell No. 3Y 7.8/1.1
W: In.
31-1/2
D:In.
11-1/4
Dimensions
H: In.
21-5/8
Weight
Lbs.
66
77
80
52e
R41 OA
Refrigerant
Charge
Lbs., Oz.
2
2,9
Oil
I Type Ill. oz.
NE022 10.8
NE022 15.2
Refrigerant Pipe
Gas Side O.D.
In.
3/8
1/2
Liquid Side O.D. i
In.
1/4
Refrigerant Pipe Length
Height Difference (Max.)
Ft.
40
Length (Max.)
FL
65
Connection Method
Indoor/Outdoor
Flared/Hared
NOTES: Test conditions are based on AHRI 2101240.
`1: Rating conditions (cooling) -Indoor. D.R. 80' F (27" C), W B 8P F(Igo .C);. Outdoor: 0.6.
'4. Indoor units receive power from outdoor units through field -supplied intercunnected wiring.
95 F (35'. C). WE. 75" F (24` Q.
-2. Rating conditions (heat ng) Indoor: D.B. 70' F (21- C), W.R. 6W F(16 -C); Outdoor D.B.
SpecitmaWns are subject to change without notice.
47-F (8 Cit, WB. is -F(6- C)I
LIMITED WARRANTY I Seven-year warranty on compressor. Five-year warranty on parts.
-3. Rating corditions(heating)-mcooc D.E.70' F (21-C)i W.B. 60' F (Iso C); Outdoor. D.B.
17° F (-8" C), W.B. 15- F (9° C).
28 / MITSUBfSHI ELECTRIC / M -SERIES / SPECIFICATIONS