HomeMy WebLinkAboutProduct Approval ffi-7 ew ouWIN DOW SOLUTIONS 2526 Okeechobee Blvd,West Palm Beach,FL 33409•561-712-9000•CRC1330822 Property Information Building Information Owner: JEANNETTE&DOUG OWENS Wind Zone: 170 MPH. j Address: 8287 SPICEBUSH TERRACE Exposure Category: C PORT ST LUCIE,FL 34952 Minimum Building Dimension: 25 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device IFDevice Max Positive EMax Negative Number Zone Width(in)-][ Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 72.75 61.75 7 35.0 -38.2 2 Int 34.75 22.75 7 37.8 -41.0 3 Int 72.75 61.75 7 35.0 -38.2 4 Int 25.25 61.75 7 37.6 -40.8 5 Int 35.75 49.25 7 37.3 -40.5 6 Int 51.75 61.75 7 35.8 -39.0 7 Int 72.75 61.75 7 35.0 -38.2 8 Int 51.75 61.75 7 35.8 -39.0 9 Int 51.75 61.75 7 35.8 -39.0 10 Int 51.75 61.75 7 35.8 -39.0 11 Int 58 79 7 35.0 -38.2 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1 Opening I Size (WxH) "N 1. HORIZONTAL SLIDER 72 3/4 x 61 314 (OFFICE) 2. FIXED WINDOWS 34 3/4 x 22 3/4 (FOYER) 3. HORIZONTAL SLIDER 72 3/4 x.61 3/4 (LIVINGROOM) 4. PICTURE WINDOW 25+14x61 3/4 8 Z (BATHROOM) 5. SINGLE HUNG 35 3/4 x 49'A 6. (BEDRSINGLE HUNG 51 3/4 x 61 314 OOM) 7. HORIZONTAL SLIDER 72 314 x 61 3/4 cn (FAMILYROOM) 7 6 o 8. SINGLE HUNG 51 314 x 61 3/4 (BEDROOM) V 9. SINGLE HUNG 51 3/4 x61 314 lwZ0 10. SINGLE HUNG 51 3/4 x 61 3/4 11. IMPACT DOOR 58 x 79 (KITCHEN) 9 2 3 4 Z Lu 0 04 to 10 meq, 0 1-- uj —i u- 0 1: d oiS co Lu UJ —J W Z Z 000 < c\I (L UJ 00 SCALE: NOT TO SCALE Feb 21,ME) �AGr..-W-�N- Site Plan PAGE: OF .i 1/4/2019 Florida Building Code Online lit BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search Florida Product Approval r@ USER:Public User Product 6wr2ai Menu>Product or Aoplication Search>Application List { Search Criteria Refine Search Code Version 2017 FL# 16851.6 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL j Product Model,Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search Results-Ap plications Type Manufacturer Validated By, Status FL16851 Revision NewSouth Window Solutions _ Ryan J.King, Approved R7 FL#:FL16851.6 P.E. History Model:f.9450 Single Hung Window Impact Rated-HVHZ (813)767- Description:Extruded Vinyl"Impact"Single Hung Tilt Window with Flange 6555 (0/X-configuration) Category:Windows Subcategory:Single Hung -Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850.487-1824 The State of Florida Is an AA/EEO employer.QjIyAaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.Ir you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here_. Product Approval Accepts: rr � etfeu Credit Card Safe https://www.loridabuilding.org/pr/pr app_lst.aspx 1/1 1/412019 Florida Building Code Online ! f SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Pubrications Contact Us BCIS Site Map Links Search Florida 1 'ttft1 Product Approval Vr USER:Public User ProduR.2V-j1-Menu>Product or Aoolicatlon Search>AqRlkatlon List>Application Detail () 3rJ`tam 3 I FL# FL16B51-R7 Application Type Revision ! Code Version 2017 Application Status Approved Comments Archived Product Manufacturer NewSouth Window Solutions Address/Phone/Email 4901 oak fair blvd tampa,FL 33610 (513)284-0129 danochstein@newsouthwindow.com Authorized Signature Vivian Wright rickw@rwbidgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email I i Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Lyndon F.Schmidt Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2019 Validated By Ryan J.King,P.E. d Validation Checklist-Hardcopy Received Certificate of Independence .FL16851 R7 COI (4)Certificate of Indeoendence.odf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA101/I.S.2/A440 2011 AAMA/WDMA/CSA101/I.S.2/A440 2008 ASTM E1886 2005 ASTM E1996 2006 ASTM E1996 2009 TAS 201,202,203 1994 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsaefoLiCDIJOysrHoxOGe9cEYNv7g2QiOQ%3d%3d 1/5 1/4/2019 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 06/07/2018 Date Validated 06/26/2018 Date Pending FBC Approval 06/27/2018 Date Approved 08/15/2018 Summary of Products Go to Page m 0 Page 1/20 0 FL At Model,Number or Name Description 16851.1 a.9400 Single Hung Window Extruded Vinyl"Non-Impact'Single Hung Tilt Window New Construction with Nail Fin(DIX-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R7 II (¢)Inst 16851.1.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 16851.1 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851.1.pdf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars, 16851.2 �b.9400 Single Hung Window Extruded Vinyl"Non-Impact"Single Hung Tilt Window with -_ Flange(O/X-configuration) --- - - --__ —- Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R7 11 (¢)Inst 16851.2.p.!f Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 16851.2 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851.2.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.3 C.9450 Single Hung Window Extruded Vinyl"Impact"Single Hung Tilt Window New — Construction with Nail Fin(O/X-configuration) Limits of Use - _ Installation Instructions - Approved for use In HVHZ:No FL16851 R7 11 (p)Inst 16851.3.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.3 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851.3.pdf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars, 16851.4d.9450 Single Hung Window Extruded Vinyl"Impact"Single Hung Tilt Window with Flange (O/X-configuration) Limits of Use Installation Instructions Approved for use In HVHZ:No FL16851 R7 11 (b)Inst 16851.4.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.4 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851.4.odf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. e. 16851.5 — - �FLt d50HVHZ SingleHung Window Impact C nstructionExtruded ywith Nai Fin(O/X Hcon gul"Impact"Single ung tration)w New Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16851 R7 Ii (JZ)Inst 16851.5.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.5 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851.5.1 additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.6 f.9450 Single Hung Window Impact Extruded Vinyl"Impact"Single Hung Tilt Window with Flange Rated-HVHZ (O/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16851 R7 li (¢)Inst 16851.6.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param--wGEVXQwlDgtmmTSTNdVPsacfoLiCDIJOysrHoxOGe9cEYNv7g2Q!OQ°/a3d%3d 215 1/4/2019 Florida Building Code Online Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.6 for Design Pressure Ratings,any FL16851 R7 AE (t)Eval 16851.6.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.7 g.4400 Single Hung Window Extruded Vinyl"Non-Impact"Single Hung Window New Construction with Nail Fin(0/X-configuration) Limits of Use Installation Instructions Approved for use In HVHZ:No FL16851 R7 11 (¢)Inst 16851.7.gdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.7 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851.7.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.8 h.4400 Single Hung Window Extruded Vinyl"Non-Impact"Single Hung Window with Flange -- --- -- --- -- (0/X-configuration) Limits of Use Installation Instructions — Approved for use in HVHZ:No FL16851 R7 II (d)Inst 16851.8.pd Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.8 for Design Pressure Ratings,any FL16851 R7 AE (d)Eval 16851.8.p�j additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars, 16851.9 1.4450 Single Hung Window Extruded Vinyl"Impact"Single Hung Window New Construction with Nail Fin(0/X-configuration) _ Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R7 II (.d)Inst 16851.9.adf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.9 for Design Pressure Ratings,any FL16851 R7 AE (0)Eval 16851.9.pdf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 16851.10 —~ a J.4450 Single Hung Window -` Extruded Vinyl"Impact"Single Hung Window with Flange(O/X -- - - - --- —- - - - -configuration) --- Limits of Use Installation Instructions Approved for use In HVHZ:No FL16851 R7 iI (c)Inst 16851.10.pd Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.10 for Design Pressure Ratings,any FL16851 R7 AE (d)Eval 16851.10.pdf additional use limitations,Installation Instructions and product Created by Independent Third Party:Yes particulars. 16851.11 `— k.4450 Single Hung Window Impact Extruded Vinyl"Impact"Single Hung Window New Construction Rated-HVHZ with Nall Fin(0/X-configuration) Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL16851 R7 II (¢)Inst 16851.11.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.11 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851.11.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.12 I.4450 Single Hung Window Impact Extruded Vinyl"Impact"Single Hung Window with Flange(O/X Rated-HVHZ -configuration) — ---- --HVHZ -- - - — -- - - - — - - - Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16851 R7 iI (h)Inst 16851.12.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes j Design Pressure: N/A Evaluation Reports Other:See INST 16851.12 for Design Pressure Ratings,any FL16851 R7 AE ()2)Eval 16851.12.odj additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.13 M.4000 Twin Single Hung Window Extruded Vinyl"Non-Impact"Twin Integral Mulled Common Jamb Single Hung Window New Construction with Nail Fin(O/X I O/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R7 II (11)Inst 16851.13.pdf https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsaefoLiCDIJOysrHoxOGe9cEYNv7g2QiOQ%3d%3d 315 1/4/2019 Florida Building Code Online Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 16851.13 for Design Pressure Ratings,any FL16851 R7 AE (b)Eva] 16851.13. df additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 16851.14 i n.4000 Twin Single Hung Window Extruded Vinyl"Non-Impact"Twin Integral Mulled Common Jamb Single Hung Window with Flange(O/X I 0/X- configuration) Limps of Use Installation Instructions Approved for use in HVHZ:No FL36851 R7 II (�Inst 16851.14.pt f Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.14 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851.14.pdf additional use limitations,Installation Instructions and product Created by Independent Third Party:Yes particulars. 16851.15 o.4000 Triple Single Hung Window Extruded Vinyl"Non-Impact"Triple Integral Mulled Common Jamb Single Hung Window New Construction with Nall Fin(0/X I O/X I O/X-configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R7 II (b)Inst 16851.15.pdf Approved.for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.15 for Design Pressure Ratings,any FL16851 R7 AE (p)Eval 16851.15.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.16 p.4600 Twin Mulled Single Hung/ Extruded Vinyl"Non-Impact"Twin Integral Mulled Common Picture Window Jamb Single Hung/Picture Window New Construction with Nail Fin(O/X 10-configuration) Limits of Use Installation Instructions Approved for use In HVHZ: No FL16851 R7 11 la)Inst 16851.16.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.16 for Design Pressure Ratings,any FL16851 R7 AE (11)Eval 16851.16.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.17 q.4600 Twin Mulled Single Hung/ Extruded Vinyl"Non-Impact"Twin Integral Mulled Common Picture Window Jamb Single Hung/Picture Window with Flange(O/X 10- configuration) Limits of Use Installation Instructions Approved for use In HVHZ:No FL16851 R7 II (¢)Inst 16851.17.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.17 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851.17.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.18 — r.4800 SH/SH/SH-Triple Single Extruded Vinyl Integrally Mulled Triple Single Hung Windows Hung – with Flange; (0/X I O/X I 0/X configuration) Limits of Use— - Installation Instructions --– – - --– Approved for use In HVHZ:No FL16851 R7 II (k)_Inst 1685j5 p0j Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.18 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851.18.pdt additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 16851.19 s.4900 SH/SH-Twin Single Hung Extruded Vinyl Integrally Mulled Twin Single Hung Windows with Flange; (O/X I O/X configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R7 I1 (d)-Inst 16851.19.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.19 for Design Pressure Ratings,any FL16851 R7 AE ( Eval 16851.19.pdf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 16851.20 It.4900 SH/SH/SH-Triple Single Extruded Vinyl Integrally Mulled Triple Single Hung Windows https://www.fioridabuilding.org/pr/pr_app_dtl.aspx7param=viGEVXQwtDgtmmTSTNdVPsacfoLiCDIJOysrHoxOGe9cEYNv7g2QiOQ%3d%3d 4/5 1/4/2019 Florida Building Code Online Hung with Flange; (O/X I O/X I 0/X configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL16851 R7 Il (d)Inst 16851,20.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 16851.20 for Design Pressure Ratings,any FL16851 R7 AE (d)Eval 16851 20 Ddf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. Go to Page Page 1/2 O Ncrl i Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850.487-1824 The State of Florida is an WEED employer.QRyri_ght 2007-2013 State of Florida,:: rlP vacv Statement::Accessibllity,Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: .Cted rr, Credit Card Safe https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsacfoLiCDIJOysrHoxOGegcEYNv7g2QiOQ%3d%3d 515 `` ,,.... ewSouth5SMAX.OVERALL FLANGE%MDTH WINDOWSOLUTIONS 1(�54'""Ax°"�"LL�A"'E"�°'" .�''ti Z �• , I ��.�•• • To n 4901 Oak Fair Blvd.,Tampa,FL 33610 o�s Z U N•; / o O "Z; / \ Ci Em Zm°oU cwt ! o r 9 d n � H� mda� 9450 Single Hun Window 9 9 � ' N IMPACT RATED - HVHZ m o QZ w/Flange Z oz V GW R O = GENERAL NOTES G 1. This product has been evaluated and Is In compliance with the 6th Edition o a b (20171 Ronda Budding Code(FBC1,Including the"High Velocity Hurricane a a Zone"(HVHZ1. // Ile fn 2. Product anchors shag be as listed and spaced as shown on detalb.Anchor o I N embedment to base material shag be beyond wag dressing or stucco. ^NF 3. when used in the-HVHZ",this product compiles with Section 1626 of the Florida $ o Building Code and does not require an impact resistant covering. E o=a o b 6��N 4. For 2K stud framing construction,anchoring of these units shag be the same as N that shown for 2x buck masonry construction. o o n � a 5. Site conditions that deviate from the details of this drawing require further U engineering analysis by a licensed engineer or registered architect. 0 0 0 Wig;: 5 ^new R m ^^ems < zC TABLE OF CONEENiS MAX OVERALL MAX OVERALL MAX MAX DESIGN PRESSURE FLANGE FRAME DAY LITE DAYUFE GLASS z SHEETS DESCRIPIION DIMENSION DIMENSION TYPE fpm 1 Typical elevations,design pressures LL general notes DIMENSION DIMENSION (O► LEI (FIXED) FOS• NEG. ME 2/19/14 's 2 Vertical&horizontal cross sections SS.G X 77.(r SW X 76.G 47.25 x 34-W 4935"x 34.x^ G1.G2 +SS.0 -65.0 SCAM, N.T.S. 3 Vertical 3 horizontal cross sections DWM By. JK m 4 Buck LL frame anchoring 31L0 X 63.0' 37A-X 620• 30,25':27.38° 32.7rx 27.r GI.02 +65.0 -85.0 au,eY. LFS 3 a .5_..__Components °P" NO- 851.6 a y 6 Bill of materials and glazing details Note:This product,when used with GI glaring,is not approved for use above 30 feet in the-Mr. __-- -FL FL-166 85 t.6 N SNar—Lori: 0 a •oMl raMva�ntuo°rn�u�uu•M•Y•tar p rigs *ON Yo 3dw SHOtl�3S SSO!!� ti Le1BOCY•cm VON�4d 7YINOIUM �•llrJfJll3A N .�. C60CC 1d 'af+lb/►'OCL aC 'Old Sn MU ri '03 H[C OL 3LVCdn St 9Z 9 [ vi x 'OIO laim dmoo Draw" 'X 8N3MIIOWd 71P 4! LI Z[ S 0 F" ``````\`\►ltllll LL�,',,,i SOKI,i MOQNIM;JNIIH 379NI5 Sii 3aS MOQN[N Z9+LC Ll SIL 1• N z I �l QO OL W MAY :1Jfl00Ld YOdll L! :AIL! OMPTH C if 111110 NAD TM I .r/L•L WWi/L•1 an a • ZZIN p � r i r .. N U a � v. 15 L! r+ N W ♦� � W � � I 61 a � t 32 n u i ao ^• f N N" .4 O X 17" u �N �N � •. L•= t1Af[i0t110191•1foom4-7%"SAM IM1• !> �/•PIR1-V1lMNYISHa PM1�P^�SWNW Y R11 emv4"South twodows PEAMANINM-Foe&ft0wApp NJz%K-166'sm4v ftW-C-hWL-16151(M7)\FL-76ML&&yD-2 •, a ��� m � 4 wr CP A ww x 0 N 13 P r to Q a w u+ fig w a 71i WN V NI r e P *, r. A X N r a033 r 5' SL Y firl w w z a . a S >v Tu a w fid v � v ww r 17 N r •a � c* P A P f`���55 P I-1/OAAR7 nmIrwL 36 B.pyp•l EMB.(TYPE / `LLLLL11111III7/fgA�4 ` HsL43101 l O=bW7{,2017 2 L 7 PRODUOT: Or+i � 5 T 7 1JP647E TD 8M 6D. 2017 F13C JMX SINGLE HUNG IYwm don R Swwwt ��j �'••w ��, T7 18 AL ANCHOR sfft ON b IN.d340G 711111/1/ Z Y PART 0R ASSNBLY: 1 i7 75 ClAZ1TIG EIIALCIAIG COHStN.77d41S• INC. $4 1 6/20/15,U-MITE TO 501 M • P.C.Dox 770,Vo kx4 R 33808 0 + OATE CM HORI NS AL PIM No-I 813,089A107 FHPE CA No.0813 71DT 4 R.W.OWLOn1O QC1uuLTAHM Iw0. Ri,QlvttslNtwSoutl�WlndoxeN�tNxNNMM-fbiidswoduRAPD�a'3515151t1pe)4vtgyC•f3aNY�\F4illStC�7T�d6ES16dry,42 W N r 4 O i ..; PYP,j K 00ftW It'2H7 M� X r I I ' r\\�tlttiiHtttt�, UPOW Msoot sec nc Paooucr NVNC WNDow {y am ~ �. +.y... 1 42/1.3/17&M 37x6? MMOOw tFs .PLG No. 43400 '�i/� ,•���• 2 3 4 T r6 I/ \\ R y m t ! Ib atJu.O�MC COl1Rq♦ tiR40. t TO S3H E0. 20t4 } P�1ti DR tii�K FPAME �.0. ewc 239.Vobb% FL 33561f ANCHORM Phom Ne,t 813.BA0A107 8 ttat a.w.Mun.omo carnsuraunr 3Ko. FM C.A. No.gala n4kCZ*ijW WSouthwhtd0mvc+MMTn A-Fbfkba dUCIA OMM-IM519*"g\C Mnft t-IMIMUsw.•MlAd■ss•1 2.27' 3.29" i P Q our 219' IN a III Q j G ,ArT p vr__ qQ � � b _T Daw 2.IT { N" t Q OdMM 1&2017 = s &III- UAWITE In 8TH 2077 JK PROOU NI �s SMIGLE NlJNC WINDOW ryyTnfdon F.340fnldl 1 3 aADDED]7x62 W SltetFs F.0No. assa0 '412 7 NL JK PAIR'O9 A�19LY: CP.O.stmema �Fa 3369!!x to rTE STH ED. ZOIA FBC lF5 j!�!CQMPORM pkww N" 1013.969.9197 ILrB G. Na 9013 2014 A.W.9UILOMS ewmm"Tu no. --REVISIONS X I \ R ° 9't599i-7d iF V uQk° ---------- -- -_ 9NI113S(9)OMI M 9 M.9B<`ONWO 310N C F 'N ii Lt Z�t WN ON1iVi0 N� V V V IAm a?ItflMw Tfm c Y p V SSY19a3af3d1++@l.!?!1 � i 3�YdS7pY SSY19�IV3t8JV,S1t � >V a�°"� 79AV17EIhN8Mi�tiYSJ160Q � SSVIJ 03iV3NNV 9l1 ':'rT10iWAM OAd a1JR18Od SWIRIWU NOMVDUUMD NWW.NI SMSN3On VMn81Xd 1rh Y S Jwtvt0 Aa a9OiWU 39 OL 3W SMOaM VW MWWW?JORM OAd OM U M MA WJV MU* + 'JH2 sms YOWL am SWIS wVOd La91n8 tr. OAd OMM ) dRla IMaaa ZZ OAd aM�11 MAO 1Z 9 wnwsl-Eso1+ i1'8W3011O}1Mmu 6t xtn�a 3 WOW avw 91t tell t9 wn1Vs1•O 1t�1"D4WNMW3WOUM CL ZNAFt,eyi�l teol Oi esn xK penaxidc 14N _ sum at S �i Wtt7YS1•f9a9 1taW3O71O3Nt�17N VX)m 01 ��SSS UUIe U 031�11V1�W 1�8W9OaOd11811 To�o"ImW 6 { � S4V10�NdNWAlI � �OAdaI'J�t • YYO11O9 8 33VdSW OAd `DIJI?! •4 flfilJlOOi L SiYI'JQ31V31NV.9/1 O?AAdd a IM ONMW 9 37US s OAd ahsJlB Tug v w v t9AVRBIM8Ad�lCftiNS.060ti Jr"� OAdMrd VSId UNacoanam 9 i ssvt�a37v3reiv.i�t1--'� (—J 3Adalala am VIMIA San Z OAd CMIN .Sft nava t ''�` 73315 *mw dd XOiII 7 H iNVTMONsM 733ts sWs r t»s Ndd o1 x -_ 7BusSY10 1ro.@JLmom LEM WIW %qwmftLsmn r N 733ts SM Ndd.Ztt'Z X OI# N a 6 `��� fNtritpi DOOM 0=<go OMS �J 73315 NfYY i•t Hdd X t d 41' 'O ION Ol JN KMN003i380NOO'MW ISd 000'£-AMNOSM 3 s r 7$15 M31iOS3137tONMAkUHOOO73Ndd.*/nxxt a 7VJMW my 3OYdSwRt I"1=!t O DOOM SS Q=t X 9 S7YAd1YWlOT11/ a 1/4/2019 Florida Building Code Online Al BCIs Home Log In User Registration Hot Topics i Submit Surcharge Stats&Facts Publications Contact Us ! EC Site Map Links Search b'r -`�lProduct Approval "`° USER:Public User r Product Approval Menu>Product or Agplication Search>Application List Search Criteria Refine Search Code Version 2017 FL# 15054.18 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model,Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search Results-Applications FL# Types Manufacturer Validated By, Status FL15054- Revision NewSouth Window Solutions Ryan J.King, Approved R6 FL#:FL15054.18 P.E. History Model:r.9650 Fixed Window-Impact Rated-HVHZ (813)767- Description.Extruded Vinyl Direct Glazed"Impact"Fixed Window with Flange 6555 (0 configuration) Category:Windows Subcategory:Fixed •Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission If necessary. Contact ::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850.487-1824 The State of Florida Is an AA/EEo employer. Privacy Statement::Accessibility statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,FS.,please click e e. Product Approval Accepts: Credit Card Safe https://www.floridabuilding.org/pr/pr app_Ist.aspx 1/1 1/4/2019 Florida Building Code Online BCIS Home Login User Registration Hot Topica Submit Surcharge Stats&Facts Publications Contact Us ` BCIS Site Map I Links Search b a Product Approval IUSER:Public User } �rg9uct Approval Menu>Product or Application Search>Qpytication List>Application Detail U �a Glwtt f FL# FL15054-R6 Application Type Revision Code Version 2017 Application Status Approved i Comments , I Archived Product Manufacturer NewSouth Window Solutions Address/Phone/Email 4901 oak fair blvd tampa,FL 33610 (513)284-0129 danochstein@newsouthwindow.com Authorized Signature Vivian Wright rickw@rwbidgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Fixed Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Lyndon F Schmidt Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2019 Validated By Ryan 1.King,P.E. Validation Checklist-Hardcopy Received Certificate of Independence FL15054 R6 COI (4)Certificate of IndeoenderiL f Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA101/I.S.2/A440 2008 AAMA/WDMA/CSA101/I.S.2/A440 2005 AAMA/WDMA/CSA101/I.S.2/A440 2011 ASTM E1886 2005 ASTM E1996 2006 ASTM E1996 2008 ASTM E1996 2009 TAS 201,202,203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL15054 R6 Ea t v (R)_guivalencv of Standards,of httpsl/www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDquS73Fr2ZyiPl8Ew9YUwBR2H3fjp/*2fiTNBzuDZKx5cBPf3A%3d%3d 1/5 1/4/2019 Florida Building Code Online Sections from the Code Product Approval Method Method 1 Option D Date Submitted 01/23/2018 Date Validated 02/05/2018 Date Pending FBC Approval 02/15/2018 Date Approved 04/10/2018 Summary of Products j Go to Page ® Page 1/20 0 FL# Model,Number or Name Description 15054.1 a.DuraGard Fixed Window Extruded Vinyl Direct Glazed"Non-Impact"Fixed Window utilizing a Nail Fin Installation(0 configuration) Limits of Use — -- —— Installation Instructions Approved for use in HVHZ:No FL15054 R6 II (j Inst 15054.1.adf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15054.1 for Design Pressure Ratings,any FL15054 R6 AE (a)Eval 15054,1,pdf additional use limitations,installation instructions and product Created by independent Third Party:Yes particulars. 15054.2 b.DuraGard Fixed Window Extruded Vinyl Direct Glazed"Non-Impact"Fixed Window(O ! configuration) -_----- Limits of Use Installation Instructions Approved for use in HVHZ:No FL15054 R6 II (a)Inst 15054.2.odf Approved for use outside HVHZ:Yes Verifled By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15054.2 for Design Pressure Ratings,any FL15054 R6 AE (a)Eyal 15054,2 pddf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15054.3 c.TrustSer(es Fixed Window Extruded Vinyl Direct Glazed"Non-Impact"Fixed Window utilizing a Nail Fin Installation(0 configuration) Limits of Use Installation Instructions Approved for use In HVHZ:No FL15054 R6 II (a)Inst 15054,3.Rdf Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15054.3 for Design Pressure Ratings,any FL15054 R6 AE (a)Eval 15054,3.pdf additional use limitations,Installation instructions and product Created by Independent Third Party:Yes particulars. 15054.4 d.TrustSerles Fixed Window Extruded Vinyl Direct Glazed"Non-Impact"Fixed Window(0 configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15054 R6 II (p)Inst 15054.4.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15054.4 for Design Pressure Ratings,any FL15054 R6 AE (ij)_EyqLj5054.4,pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15054.5 e.Sashlite Fixed Window Extruded Vinyl Sash in Frame Glazed"Non-Impact"Fixed T _ - Window utilizing a Nall Fin Installation(0 configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FLIS054 R6 II (2)Inst 15054,5.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15054.5 for Design Pressure Ratings,any FL15054 R6 AE (a)Eval 15054.5.pdf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 15054.6 -' - f.Sashlite Fixed Window —— Extruded Vinyl Sash In Frame Glazed"Non-Impact"Fixed httpsJ/www.floridabuilding.org/pr/Pr_app_dtl.aspx?param=wGEVXQwtDquS73Fr2ZyiP18Ew9YUwBR2H3fI%2fiTNBzuDZKx5cBPf3A%3d%3d 2/5 1/4/2019 Florida Building Code Online Window(0 configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15054 R6 II (a)Inst 15054.6.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15054.6 for Design Pressure Ratings,any FLIS054 R6 AE (a)Eval 15054.6,pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars--- -- - - -- ------ — __—_-- --------- - ---- - - 15054.7 - g.DuraGard Fixed Window - - Extruded Vinyl Direct Glazed"Impact"Fixed Window utilizing a Nail Fin Installation(O configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FLIS054 R6 11 (a)Inst 1.5054.7.12df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See Inst 15054.7 for Design Pressure Ratings,any FL15054 R6 AE (a)Eval 15054.7.pdf additional use limitations,Installation Instructions and product Created by Independent Third Party:Yes particulars. ---- ----- ----- 15054.8 h.DuraGard Fixed Window Extruded Vinyl Direct Glazed"Impact"Fixed Window with Flange(0 configuration) Limits of Use Installation Instructions Approved for use In HVHZ:No FL15054 R6 I1 (a)Inst 15054.8.12df Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See Inst 15054.8 for Design Pressure Ratings,any FLIS054 R6 AE (a)Eval 15054.B.Rdf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 15054.9 1.4600 Fixed Window Extruded Vinyl Direct Glazed"Non-Impact"Fixed Window utilizing a Nail Fin Installation(O configuration) Limits of Use Installation Instructions Approved for use In HVHZ:No FLIS054 R6 II (a)Inst 15054.9,pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15054.9 for Design Pressure Ratings,any FLIS054 R6 AE (a)Eval 15054.9.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15054.10 —J-_.4600 Fixed Window Extruded Vinyl Direct Glazed"Non-Impact"Fixed Window with Flange(O configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15054 R6 II (a)Inst 15054.10.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See Inst 15054.10 for Design Pressure Ratings,any FL15054 R6 AE (a)Eval 15054.'10.odf additional use limitations, installation instructions and product Created by Independent Third Party:Yes particulars. 15054.11 —— :jk��4650 Fixed Window-Impact Extruded Vinyl Direct Glazed"Impact"Fixed Window utilizing a ted-HVHZ Nail Fin Installation(0 configuration) -- --------------- -- ------------------- Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL15054 R6 Ii (a)Inst 15054.11.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15054.11 for Design Pressure Ratings,any FL15054 R6 AE (c) Eval 15054.11.odf additional use limitations,Installation Instructions and product Created by Independent Third Party:Yes particulars. 15054.12 — — I.4650 Fixed Window-Impact Rated Extruded Vinyl Direct Glazed"Impact"Fixed Window with - -HVHZ - Flange(0 configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FLIS054 R6 II (a)Inst 15054.12.adf Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15054.12 for Design Pressure Ratings,any FL15054 R6 AE (c)Eval 15054.12.adf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. 15054.13 m.9600 Fixed Window Extruded Vinyl Direct Glazed"Non-Impact"Fixed Window https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDquS73Fr2ZyiPlBEw9YUwBR2H3fj%2fiTNBzuDZKx5cBPf3A%3d%3d 3/5 1/4/2019 Florida Building Code Online I utilizing a Nail Fin Installation(O configuration) Limits of Use 1 Installation Instructions Approved for use in HVHZ:No FLIS054 R6 II (a)Inst 1054.13.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15054.13 for Design Pressure Ratings,any FLIS054 R6 AE (a)Eval 15.054 13pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. ------ -- — - ----_ .—_..—___ __—�---- 15054.14 n.9600 Fixed Window Extruded Vinyl Direct Glazed"Non-Impact"Fixed Window with Flange(O configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL15054 R6 II (a)Inst 15054.14.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 j Impact Resistant:No Created by Independent Third Parry:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15054.14 for Design Pressure Ratings,any FL15054 R6 AE (a)Eval 15054.14.p additional dfl use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. —— —_ 15054.15 0.9650 Fixed Window-Impact Extruded Vinyl Direct Glazed"Impact"Fixed Window utilizing a Rated Nail Fin Installation(O configuration) Limits of Use Installatlon Instructions Approved for use In HVHZ: No FLIS054 R6 II (a)Inst 15054.15.odf. Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15054.15 for Design Pressure Ratings,any FL15054 R6 AE (g)Eval 15054.15.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15054.16 ' p.9650 Fixed Window-Impact— Extruded Vinyl Direct Glazed"Impact"Fixed Window with-- Rated Flange(O configuration) — Llmits of Use Installation Instructions Approved for use in HVHZ:No FL15054 R6 II (p)Inst 15054.16.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,RE,43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports ! Other:See INST 15054.16 for Design Pressure Ratings,any FL150S4 R6 AE (c) Eval 15054.16.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 1505417— -1 Rated 9650 Fixed Window-Impact Extruded Vinyl Direct Glazed"Impact"Fixed Window utilizing a Rated-HVHZ _ Nail Fin Installation(O configuration) — _ — Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15054 R6 11 (g)Inst 15054.17.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15054.17 for Design Pressure Ratings,any FLIS054 R6 AE (C)Eval 15054.17.pd additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15054.18 r.9650 Fixed Window-Impact Rated Extruded Vinyl Direct Glazed"Impact"Fixed Window with -HVHZ Flange(O configuration) Limits of Use Installation Instructions Approved for use In HVHZ:Yes FLIS054 R6 II (a)Inst 15054.18.gdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15054.18 for Design Pressure Ratings,any FL15054 R6 AE (g)Eval 15054.18.pd1 additional use limitations, installation Instructions and product Created by Independent Third Party:Yes particulars. 15054.19 — s.4800 Twin Mulled"Common Jamb" Extruded Vinyl Direct Glazed"Non-Impact"Integral Mulled Fixed Window "Common Jamb"Twin Fixed Window with Flange(0/O Vertical or Horizontal configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No F1,15054 R6 II (a)Inst 15054.19.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15054.19 for Design Pressure Ratings,any FL15054 R6 AE (a)Eval-15054,19.pdf additional use limitations,installation Instructions and product Created by Independent Third Party:Yes particulars. httpsJ/www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquS73Fr2ZylPl8Ew9YUwBR2H3fj%2frTNBzuDZKx5cBPf3A%3d%3d 415 114/2019 Florida Building Code Online 15054.20 t.4800 Mulled"Common Jamb" Extruded Vinyl Direct Glazed"Non-Impact"Integral Mulled Fixed Window "Common Jamb"Triple Fixed Window utilizing a Nail Fin Installation(0/0/0 Vertical or Horizontal configurations) Limits of Use Installation Instructions Approved for use In HVHZ:No FL15054 R6 II (a)Inst 15054.20.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:-No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15054.20 for Design Pressure Ratings,any FL1S054 R6 AE (P)Eval 15054.20.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. Go to Page —�----------_--_--------------- ---------- ----— � � Page 1/2 [i,u to Ncxl Contact Us::2601 Blair Stone Road,Tallahassee Fl.32399 Phone:850-487-1824 j The State of Florida is an AA/EEO employer.Copyright 2007.2013 State of Florida.::Privagy,Statement::Accessibilitv,Statement::Refund Statement I Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 4S5,F.S.must provide the Department with an email address If they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: nYa. I Credit Card Safe https://www.floridabuilding.org/pripr_app dtl.aspx?param=wGEVXQwtDquS73Fr2ZyiPlBEw9YUwBR2H3f*/a2iiTNBzuDZKx5cBPf3A°/a3da/o3d 5/5 trot rr,. .." ice: m i O [ENewsouth WINDOWSOLUTIONs 61"MN(OVERALLRN WIDTH '�i4,•' 4901 Oak Fair Blvd.,Tampa,FL 33610 60'" OPLL FBnME:M Z 5 o gi{ \ z v \V �N4 9m=a 9650 Fixed Window �z Impact Rated - HVHZ Uz W/ Flange z (33 cl GENERAL.NOTES � ii F W I. M product hos been evoluoted and is in compliance With the 6th motion(2017)Florida Budding Code(FBC)structural requirements including the High Velocity Hurricane lona' J' (HVHZ). < K c � U 2. Product anchors shall be as rated and spaced as shown on details.Anchor embedment to m base material shall be beyond won dressing or stucco. a a a 3. When used in the°HVHZ'this product complies with Section 1626 of the Florida Building Code and does riot require an impact resistant covering. � U 4. When used in areas outside of the HVHP requiring wind bome debris protection it*product complies with FBC Sections 1609.12&R301212 and does not require an impact resistant covering.This product meets missile level'['and includes Wind Zone 4 as defined in ASTM $o E1996 and FBC Sections 1609.122&R3012-Ul. 5. For 2x stud framing construction,anchoring of these units shad be the some as that shown for 0 e $ 2x buck masonry construction. s 6. Site condifiors that deviate from the details of this drawing require further engineering anotysis by a licensed engineer Or registered architect. NOTE:VERTICAL ORIENTATION SHOWN(HORIZONTAL ORIENTATION ALSO APPROVED) _ 7. This product meets water infiltration requirements for'HVHr. MAIL OVERALL MAX OVERALL MAX GLASS OFSlGN PRESSURE g FLANGE FRAME DAYLITE (PSF) N N Q rz TABLE OF CONTENTS DIMENSION DIMENSION DIMENSION TYPE NEQ o m F42 f 37.1' DESCRIFFION X73.1- 76.0'X 72.D' 31.75 X 67J5' Gt +70.0 7Q0 Typical elevations,design pressures&general notes - o�m 6126115 = Horizontal aoss sections 611 .'X85.1' 60.0"X44. 55.75•X79.75' G2 +60.0 -60.0 SME N.T.S. Horizontal cross sections MM0" SMEw JK m Buck anchoring am BY, LFS Frame anchoring Bill of materials.-components&glazing details --- - Note:This product is not approved for use above 30 feet in the°HVHP. FL—t 5054.to o e N son 1 a 6 C a a MCdetdsVdm Sou1fi Windays PENaAN0r1W-NolfaU ProduR WP�sVI-1Sost FcadlC.pt�.in�t.150S10017N�1S0%Isdeg,2.2 • • .d r .F-- 7 T ' N + N � N W v Z N N 2.a i N C")M. �1 i W d • • d g A ry In r N r N p `��tNtlllllll////'I 4 ' No.43�09 OcwW1$2017S e, PROOUCF. e� p tyld, F.Schmidt 4 NdrSouth p.E Ne. 43409 g y ONi 27 UPDATE TO BTM ED. 2077 FBC JK PARr OR Y: SUILDIN9 CONSULTANTS. IND. 1 9 6 16 AWW ALT. HORlZON7AL �Yy P.O. Sox 230'VbMw, rl 3S693 m N NO DATE, CROSS SECTIONS Phonw N04 813.669.9197 FOPE CA. No. 9813 O 3Ol 0 R.W.EWLDING CONMLTANM IND. 1 0 ,tpt * t K H01E.gmetMetdsaemwA 1-11�MRd f ftougag le of 3ltreads gig nyp�h Maid C 1 y * 2I: INMR C 1 �tv g°�I n Oil Nrazlog 12 12 tt p Y 12 • .• 9 o Tf 2 o b a b G1 G2 n b E 2 ExleeoR 9 2 Gl G2 . 3 Mom D"dtoM Ony r b SECT ON MOM 3 +W/sleets►udreen�o�on E MAX,DESIGN PRESSURE FOR ALTERNATE A MB.�lj d ANCHORING LOCATION SHOWN ON THIS SHEET c ±65 PSF(UP TO 36"X 7T FRAME SIZE) a L 1 t50 PSF(UP TO MY X84"FRAME SIZE) 1 KmfjoR H R y ` 12 • 12 0 v .• pp • O• D1 q w G1 G2 I-Ilf'M1N. 2 G1 G2 —1 N.T.S. E LFS /-l-N NOW NlAL CR S ON 2 R L C O SE ON °7�O'd e Ft—f505L18 n - - efu 3_a'_L '.MI�Jr1Y1.'1mXgD gNIGTIf1A'!It'M L t Oi Q vivo-N yo 'JA47lOFgNV Lets•ato•rto-ON�.geyd rG'9Cr Zi'ggY[q1{OCL8 Nott ?lOifONY't7Y 4900Y 9t 9 6 t V1 X ,``11�11�1f1/!fq/ 1V1SN00 OPR01H1i •A�811 k1' am LCOS Hl9 91 31YOdtf l `��� '.�' ,. �i✓� iPao", :��PttR'1 y�nggntyN ••tDMtOild 3 tl t t L3PZ'�t�9nPA � I ' NAII A o'O%VW.LI I �► i. {'dilly '70xvw sl is -+ x y9 6 ! _i, ? op all i a:•ra.Pst•Kosr-vttccat►rsosr-tn�w+o-�u+�+sosc-��+acrav��rl•wnari.wn�a�.�an+untaros�rrWu+ro�ro MO*W�W"saw W[fW*M PU0AANRiM-Raft M)dUCIAXMRWL-1$M WodkC. S4 14 car SL PC Co - .4n. . 111MMO.0 mea 11-MAXOQj - .0C", ? \ jr % 1A. Ookboria I N+rSolrth PSE Ift.43W ffiff OR ASSDMLY,, lllWiIII FPAVC Aw'15==10,Vchim.FL 33M ANCHOM Fa 0. 1FNLOFMATERfA15 119A� DBClIl4lDM WiH1At .`��� �� .6I in A IX BUCK x 0 WOOD B 2X B K x WOOD C 1/4 MAX.SHIM SPACE - 0 D I/4X2%VCPHiELCOORIIWCONCRETESCREW STEEL oo y� rf E �MA9CM TRY-3AOD 1 OR HOLLOW BLOCK GTO ATO ACF CONCRETE �4 * ,����� � j F NTOXTPPH 1-T MIN � nn 0062 I Og�� rrrrnf^ 8 - G 1/4"X 3-IX NIMH ELCO OR ITW CONCRETE SCREW STEEL D F� g H 1/4 X 23/4 HWH ELCO OR FTYU CONCRETE SCREW STEEL J STEELSTUD .033' A653GRADE33 Id .FLn45 STEL Z G BEAD K #10PPHSEIF4RBIINGSMS S11H L #I0XrPFHSf4(I-l)rMIN.EM[BEDMENQ STEEL 1 EXTRUDED VINYL FRAME RIGID FVC �� a 2 1 EMDED VINYL GLAZING BEAD • RICA PVC 12 1 FRAME ADAPTER RIGID PVC 6 •TFE APPROVED WHBE RIGID PVC EXTERIOR DRR1JSlOW FOR WINDOWS AREM BE PRODUCED BY EXTRUDERS LKSMEES IN AAMACER11FICATION PROGRAMS FOR ROD PVC FX1R1=Ns.. aw Fes---2.06' � Z I g ISM Irr 1� ctA551�E chin BR GlA&*SE UANT GLAR1GSEAL W 8 a ls1cAF>ETLssil 7/8'O A GlAsS IHK (51CAFlF)cds217kAWM.SPACER '0.&GLASS THK f 7 IMANNEA1EDGLASS I)TANNEAIIDGLAM 0.010'SARW PVB NOLAYER O.IOS'SEN RYGLASSIN16BAYER 1/V ANNEALED GLASS I)T ANNEAM GLASS AM SPACE AIRSPACE 118'MNEAIIDGU►a Iff ANNEALED GLASS ^H ALUM.SPACER 01 3 N. u am V26115 15 L G1i G G GiA191GDlTAB uH.T.S.oftn: .1K ■ orc x LFS 3 auw�Ma: a - ---- - --- -- - NOTE:GLAZINGa96'WDEREQUIRES TWO PSETTING BLOCKS CONFORNWGTO FBC SECTION 241123.1 --- - - R-15054.1 B n so}*J---p-jo :