HomeMy WebLinkAboutProduct Approval ffi-7
ew ouWIN DOW SOLUTIONS
2526 Okeechobee Blvd,West Palm Beach,FL 33409•561-712-9000•CRC1330822
Property Information Building Information
Owner: JEANNETTE&DOUG OWENS Wind Zone: 170 MPH.
j Address: 8287 SPICEBUSH TERRACE Exposure Category: C
PORT ST LUCIE,FL 34952 Minimum Building Dimension: 25 ft.
Mean Roof Height: 15 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device IFDevice Max Positive EMax Negative
Number Zone Width(in)-][ Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 72.75 61.75 7 35.0 -38.2
2 Int 34.75 22.75 7 37.8 -41.0
3 Int 72.75 61.75 7 35.0 -38.2
4 Int 25.25 61.75 7 37.6 -40.8
5 Int 35.75 49.25 7 37.3 -40.5
6 Int 51.75 61.75 7 35.8 -39.0
7 Int 72.75 61.75 7 35.0 -38.2
8 Int 51.75 61.75 7 35.8 -39.0
9 Int 51.75 61.75 7 35.8 -39.0
10 Int 51.75 61.75 7 35.8 -39.0
11 Int 58 79 7 35.0 -38.2
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.
Page 1 of 1
Opening I Size
(WxH) "N
1. HORIZONTAL SLIDER 72 3/4 x 61 314
(OFFICE)
2. FIXED WINDOWS 34 3/4 x 22 3/4
(FOYER)
3. HORIZONTAL SLIDER 72 3/4 x.61 3/4
(LIVINGROOM)
4. PICTURE WINDOW 25+14x61 3/4 8 Z
(BATHROOM)
5. SINGLE HUNG 35 3/4 x 49'A
6. (BEDRSINGLE HUNG 51 3/4 x 61 314
OOM)
7. HORIZONTAL SLIDER 72 314 x 61 3/4 cn
(FAMILYROOM) 7 6 o
8. SINGLE HUNG 51 314 x 61 3/4
(BEDROOM)
V
9. SINGLE HUNG 51 3/4 x61 314 lwZ0
10. SINGLE HUNG 51 3/4 x 61 3/4
11. IMPACT DOOR 58 x 79
(KITCHEN) 9
2
3 4 Z
Lu 0 04
to
10 meq, 0
1--
uj —i
u-
0 1: d
oiS co
Lu UJ —J
W
Z
Z 000
< c\I (L
UJ 00
SCALE:
NOT TO SCALE
Feb 21,ME)
�AGr..-W-�N-
Site Plan
PAGE: OF
.i
1/4/2019 Florida Building Code Online
lit
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search
Florida
Product Approval
r@ USER:Public User
Product 6wr2ai Menu>Product or Aoplication Search>Application List
{ Search Criteria Refine Search
Code Version 2017 FL# 16851.6
Application Type ALL Product Manufacturer ALL
Category ALL Subcategory ALL
Application Status ALL Compliance Method ALL
Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL
j Product Model,Number or Name ALL Product Description ALL
Approved for use in HVHZ ALL Approved for use outside HVHZ ALL
Impact Resistant ALL Design Pressure ALL
Other ALL
Search Results-Ap plications
Type Manufacturer Validated By, Status
FL16851 Revision NewSouth Window Solutions _ Ryan J.King, Approved
R7 FL#:FL16851.6 P.E.
History Model:f.9450 Single Hung Window Impact Rated-HVHZ (813)767-
Description:Extruded Vinyl"Impact"Single Hung Tilt Window with Flange 6555
(0/X-configuration)
Category:Windows
Subcategory:Single Hung
-Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850.487-1824
The State of Florida Is an AA/EEO employer.QjIyAaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mall.Ir you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalis
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here_.
Product Approval Accepts:
rr � etfeu
Credit Card
Safe
https://www.loridabuilding.org/pr/pr app_lst.aspx 1/1
1/412019 Florida Building Code Online ! f
SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Pubrications Contact Us BCIS Site Map Links Search
Florida
1 'ttft1 Product Approval
Vr USER:Public User
ProduR.2V-j1-Menu>Product or Aoolicatlon Search>AqRlkatlon List>Application Detail
() 3rJ`tam 3 I FL# FL16B51-R7
Application Type Revision
! Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer NewSouth Window Solutions
Address/Phone/Email 4901 oak fair blvd
tampa,FL 33610
(513)284-0129
danochstein@newsouthwindow.com
Authorized Signature Vivian Wright
rickw@rwbidgconsultants.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
I
i
Category Windows
Subcategory Single Hung
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Lyndon F.Schmidt
Evaluation Report
Florida License PE-43409
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2019
Validated By Ryan J.King,P.E.
d Validation Checklist-Hardcopy Received
Certificate of Independence .FL16851 R7 COI (4)Certificate of Indeoendence.odf
Referenced Standard and Year(of Standard) Standard Year
AAMA/WDMA/CSA101/I.S.2/A440 2011
AAMA/WDMA/CSA101/I.S.2/A440 2008
ASTM E1886 2005
ASTM E1996 2006
ASTM E1996 2009
TAS 201,202,203 1994
Equivalence of Product Standards
Certified By
Sections from the Code
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsaefoLiCDIJOysrHoxOGe9cEYNv7g2QiOQ%3d%3d 1/5
1/4/2019 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 06/07/2018
Date Validated 06/26/2018
Date Pending FBC Approval 06/27/2018
Date Approved 08/15/2018
Summary of Products
Go to Page m 0 Page 1/20 0
FL At Model,Number or Name Description
16851.1 a.9400 Single Hung Window Extruded Vinyl"Non-Impact'Single Hung Tilt Window New
Construction with Nail Fin(DIX-configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16851 R7 II (¢)Inst 16851.1.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 16851.1 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851.1.pdf
additional use limitations,installation Instructions and product Created by Independent Third Party:Yes
particulars,
16851.2 �b.9400 Single Hung Window Extruded Vinyl"Non-Impact"Single Hung Tilt Window with
-_ Flange(O/X-configuration) --- - - --__ —-
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16851 R7 11 (¢)Inst 16851.2.p.!f
Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 16851.2 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851.2.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16851.3 C.9450 Single Hung Window Extruded Vinyl"Impact"Single Hung Tilt Window New
— Construction with Nail Fin(O/X-configuration)
Limits of Use - _ Installation Instructions -
Approved for use In HVHZ:No FL16851 R7 11 (p)Inst 16851.3.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16851.3 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851.3.pdf
additional use limitations,installation Instructions and product Created by Independent Third Party:Yes
particulars,
16851.4d.9450 Single Hung Window Extruded Vinyl"Impact"Single Hung Tilt Window with Flange
(O/X-configuration)
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL16851 R7 11 (b)Inst 16851.4.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16851.4 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851.4.odf
additional use limitations,installation Instructions and product Created by Independent Third Party:Yes
particulars.
e.
16851.5 — - �FLt d50HVHZ SingleHung Window Impact C nstructionExtruded ywith Nai Fin(O/X Hcon gul"Impact"Single ung tration)w New
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL16851 R7 Ii (JZ)Inst 16851.5.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16851.5 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851.5.1
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16851.6 f.9450 Single Hung Window Impact Extruded Vinyl"Impact"Single Hung Tilt Window with Flange
Rated-HVHZ (O/X-configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL16851 R7 li (¢)Inst 16851.6.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param--wGEVXQwlDgtmmTSTNdVPsacfoLiCDIJOysrHoxOGe9cEYNv7g2Q!OQ°/a3d%3d 215
1/4/2019 Florida Building Code Online
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16851.6 for Design Pressure Ratings,any FL16851 R7 AE (t)Eval 16851.6.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16851.7 g.4400 Single Hung Window Extruded Vinyl"Non-Impact"Single Hung Window New
Construction with Nail Fin(0/X-configuration)
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL16851 R7 11 (¢)Inst 16851.7.gdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16851.7 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851.7.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16851.8 h.4400 Single Hung Window Extruded Vinyl"Non-Impact"Single Hung Window with Flange
-- --- -- --- -- (0/X-configuration)
Limits of Use Installation Instructions —
Approved for use in HVHZ:No FL16851 R7 II (d)Inst 16851.8.pd
Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16851.8 for Design Pressure Ratings,any FL16851 R7 AE (d)Eval 16851.8.p�j
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars,
16851.9 1.4450 Single Hung Window Extruded Vinyl"Impact"Single Hung Window New Construction
with Nail Fin(0/X-configuration) _
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16851 R7 II (.d)Inst 16851.9.adf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16851.9 for Design Pressure Ratings,any FL16851 R7 AE (0)Eval 16851.9.pdf
additional use limitations,installation Instructions and product Created by Independent Third Party:Yes
particulars.
16851.10 —~ a J.4450 Single Hung Window -` Extruded Vinyl"Impact"Single Hung Window with Flange(O/X
-- - - - --- —- - - - -configuration) ---
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL16851 R7 iI (c)Inst 16851.10.pd
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16851.10 for Design Pressure Ratings,any FL16851 R7 AE (d)Eval 16851.10.pdf
additional use limitations,Installation Instructions and product Created by Independent Third Party:Yes
particulars.
16851.11 `— k.4450 Single Hung Window Impact Extruded Vinyl"Impact"Single Hung Window New Construction
Rated-HVHZ with Nall Fin(0/X-configuration)
Limits of Use Installation Instructions
Approved for use In HVHZ:Yes FL16851 R7 II (¢)Inst 16851.11.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16851.11 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851.11.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16851.12 I.4450 Single Hung Window Impact Extruded Vinyl"Impact"Single Hung Window with Flange(O/X
Rated-HVHZ -configuration)
— ---- --HVHZ -- - - — -- - - - — - - -
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL16851 R7 iI (h)Inst 16851.12.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
j Design Pressure: N/A Evaluation Reports
Other:See INST 16851.12 for Design Pressure Ratings,any FL16851 R7 AE ()2)Eval 16851.12.odj
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16851.13 M.4000 Twin Single Hung Window Extruded Vinyl"Non-Impact"Twin Integral Mulled Common
Jamb Single Hung Window New Construction with Nail Fin(O/X
I O/X-configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16851 R7 II (11)Inst 16851.13.pdf
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsaefoLiCDIJOysrHoxOGe9cEYNv7g2QiOQ%3d%3d 315
1/4/2019 Florida Building Code Online
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 16851.13 for Design Pressure Ratings,any FL16851 R7 AE (b)Eva] 16851.13. df
additional use limitations,installation Instructions and product Created by Independent Third Party:Yes
particulars.
16851.14 i n.4000 Twin Single Hung Window Extruded Vinyl"Non-Impact"Twin Integral Mulled Common
Jamb Single Hung Window with Flange(O/X I 0/X-
configuration)
Limps of Use Installation Instructions
Approved for use in HVHZ:No FL36851 R7 II (�Inst 16851.14.pt f
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16851.14 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851.14.pdf
additional use limitations,Installation Instructions and product Created by Independent Third Party:Yes
particulars.
16851.15 o.4000 Triple Single Hung Window Extruded Vinyl"Non-Impact"Triple Integral Mulled Common
Jamb Single Hung Window New Construction with Nall Fin(0/X
I O/X I O/X-configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16851 R7 II (b)Inst 16851.15.pdf
Approved.for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16851.15 for Design Pressure Ratings,any FL16851 R7 AE (p)Eval 16851.15.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16851.16 p.4600 Twin Mulled Single Hung/ Extruded Vinyl"Non-Impact"Twin Integral Mulled Common
Picture Window Jamb Single Hung/Picture Window New Construction with Nail
Fin(O/X 10-configuration)
Limits of Use Installation Instructions
Approved for use In HVHZ: No FL16851 R7 11 la)Inst 16851.16.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16851.16 for Design Pressure Ratings,any FL16851 R7 AE (11)Eval 16851.16.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16851.17 q.4600 Twin Mulled Single Hung/ Extruded Vinyl"Non-Impact"Twin Integral Mulled Common
Picture Window Jamb Single Hung/Picture Window with Flange(O/X 10-
configuration)
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL16851 R7 II (¢)Inst 16851.17.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16851.17 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851.17.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16851.18 — r.4800 SH/SH/SH-Triple Single Extruded Vinyl Integrally Mulled Triple Single Hung Windows
Hung – with Flange; (0/X I O/X I 0/X configuration)
Limits of Use— - Installation Instructions --– – - --–
Approved for use In HVHZ:No FL16851 R7 II (k)_Inst 1685j5 p0j
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16851.18 for Design Pressure Ratings,any FL16851 R7 AE (b)Eval 16851.18.pdt
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
16851.19 s.4900 SH/SH-Twin Single Hung Extruded Vinyl Integrally Mulled Twin Single Hung Windows
with Flange; (O/X I O/X configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16851 R7 I1 (d)-Inst 16851.19.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16851.19 for Design Pressure Ratings,any FL16851 R7 AE ( Eval 16851.19.pdf
additional use limitations,installation Instructions and product Created by Independent Third Party:Yes
particulars.
16851.20 It.4900 SH/SH/SH-Triple Single Extruded Vinyl Integrally Mulled Triple Single Hung Windows
https://www.fioridabuilding.org/pr/pr_app_dtl.aspx7param=viGEVXQwtDgtmmTSTNdVPsacfoLiCDIJOysrHoxOGe9cEYNv7g2QiOQ%3d%3d 4/5
1/4/2019 Florida Building Code Online
Hung with Flange; (O/X I O/X I 0/X configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16851 R7 Il (d)Inst 16851,20.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 16851.20 for Design Pressure Ratings,any FL16851 R7 AE (d)Eval 16851 20 Ddf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
Go to Page Page 1/2
O Ncrl
i
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850.487-1824
The State of Florida is an WEED employer.QRyri_ght 2007-2013 State of Florida,:: rlP vacv Statement::Accessibllity,Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
.Cted rr,
Credit Card
Safe
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsacfoLiCDIJOysrHoxOGegcEYNv7g2QiOQ%3d%3d 515
`` ,,....
ewSouth5SMAX.OVERALL FLANGE%MDTH
WINDOWSOLUTIONS 1(�54'""Ax°"�"LL�A"'E"�°'" .�''ti Z �• ,
I ��.�•• • To
n
4901 Oak Fair Blvd.,Tampa,FL 33610 o�s Z
U N•;
/ o O "Z;
/ \ Ci Em Zm°oU
cwt ! o r 9 d n
� H� mda�
9450 Single Hun Window
9 9 � ' N
IMPACT RATED - HVHZ
m o QZ
w/Flange
Z
oz
V GW
R O =
GENERAL NOTES
G 1. This product has been evaluated and Is In compliance with the 6th Edition
o a
b (20171 Ronda Budding Code(FBC1,Including the"High Velocity Hurricane a a
Zone"(HVHZ1. // Ile fn
2. Product anchors shag be as listed and spaced as shown on detalb.Anchor o I
N embedment to base material shag be beyond wag dressing or stucco.
^NF
3. when used in the-HVHZ",this product compiles with Section 1626 of the Florida $ o
Building Code and does not require an impact resistant covering. E o=a o
b 6��N
4. For 2K stud framing construction,anchoring of these units shag be the same as N
that shown for 2x buck masonry construction. o o
n �
a 5. Site conditions that deviate from the details of this drawing require further U
engineering analysis by a licensed engineer or registered architect. 0 0 0
Wig;: 5
^new R
m ^^ems <
zC TABLE OF CONEENiS MAX OVERALL MAX OVERALL MAX MAX DESIGN PRESSURE
FLANGE FRAME DAY LITE DAYUFE GLASS z
SHEETS DESCRIPIION DIMENSION DIMENSION TYPE fpm
1 Typical elevations,design pressures LL general notes DIMENSION DIMENSION (O► LEI (FIXED) FOS• NEG. ME 2/19/14
's
2 Vertical&horizontal cross sections SS.G X 77.(r SW X 76.G 47.25 x 34-W 4935"x 34.x^ G1.G2 +SS.0 -65.0 SCAM, N.T.S.
3 Vertical 3 horizontal cross sections DWM By. JK m
4 Buck LL frame anchoring 31L0 X 63.0' 37A-X 620• 30,25':27.38° 32.7rx 27.r GI.02 +65.0 -85.0 au,eY. LFS 3
a
.5_..__Components °P" NO-
851.6 a
y 6 Bill of materials and glazing details Note:This product,when used with GI glaring,is not approved for use above 30 feet in the-Mr. __-- -FL FL-166 85 t.6 N
SNar—Lori:
0
a
•oMl raMva�ntuo°rn�u�uu•M•Y•tar p
rigs *ON Yo 3dw SHOtl�3S SSO!!� ti
Le1BOCY•cm VON�4d 7YINOIUM �•llrJfJll3A N .�.
C60CC 1d 'af+lb/►'OCL aC 'Old Sn MU ri '03 H[C OL 3LVCdn St 9Z 9 [ vi x
'OIO laim dmoo Draw" 'X 8N3MIIOWd 71P 4! LI Z[ S 0 F"
``````\`\►ltllll LL�,',,,i SOKI,i MOQNIM;JNIIH 379NI5 Sii 3aS MOQN[N Z9+LC Ll SIL 1• N z I �l
QO OL
W MAY :1Jfl00Ld YOdll L!
:AIL!
OMPTH
C
if 111110
NAD TM I .r/L•L
WWi/L•1 an
a
• ZZIN p � r i
r ..
N U
a � v.
15
L!
r+ N
W ♦� � W �
� I
61
a � t
32
n u
i
ao
^• f N
N"
.4
O X 17"
u
�N �N � •.
L•= t1Af[i0t110191•1foom4-7%"SAM IM1• !> �/•PIR1-V1lMNYISHa PM1�P^�SWNW Y
R11 emv4"South twodows PEAMANINM-Foe&ft0wApp NJz%K-166'sm4v ftW-C-hWL-16151(M7)\FL-76ML&&yD-2
•, a ���
m �
4
wr
CP
A
ww x 0
N 13
P
r
to Q a w u+
fig
w
a 71i
WN V NI
r e
P *, r. A
X
N r a033
r 5'
SL
Y firl w
w z a
. a S
>v Tu
a w fid
v � v
ww
r
17 N
r
•a � c* P
A
P f`���55 P I-1/OAAR7
nmIrwL 36 B.pyp•l
EMB.(TYPE / `LLLLL11111III7/fgA�4
` HsL43101
l
O=bW7{,2017 2 L 7
PRODUOT: Or+i �
5 T 7 1JP647E TD 8M 6D. 2017 F13C JMX SINGLE HUNG IYwm don R Swwwt ��j �'••w ��,
T7 18 AL ANCHOR sfft ON b IN.d340G
711111/1/
Z Y PART 0R ASSNBLY:
1 i7 75 ClAZ1TIG EIIALCIAIG COHStN.77d41S• INC.
$4 1 6/20/15,U-MITE TO 501 M • P.C.Dox 770,Vo kx4 R 33808
0 + OATE CM HORI NS AL PIM No-I 813,089A107
FHPE CA No.0813
71DT 4 R.W.OWLOn1O QC1uuLTAHM Iw0.
Ri,QlvttslNtwSoutl�WlndoxeN�tNxNNMM-fbiidswoduRAPD�a'3515151t1pe)4vtgyC•f3aNY�\F4illStC�7T�d6ES16dry,42
W N r
4 O
i ..;
PYP,j
K
00ftW It'2H7
M�
X r
I
I ' r\\�tlttiiHtttt�,
UPOW Msoot sec nc Paooucr NVNC WNDow {y am ~ �. +.y...
1 42/1.3/17&M 37x6? MMOOw tFs .PLG No. 43400 '�i/� ,•���•
2 3 4 T r6 I/ \\
R y m t ! Ib atJu.O�MC COl1Rq♦ tiR40. t
TO S3H E0. 20t4 } P�1ti DR tii�K FPAME �.0. ewc 239.Vobb% FL 33561f
ANCHORM Phom Ne,t 813.BA0A107
8 ttat a.w.Mun.omo carnsuraunr 3Ko. FM C.A. No.gala
n4kCZ*ijW WSouthwhtd0mvc+MMTn A-Fbfkba dUCIA OMM-IM519*"g\C Mnft t-IMIMUsw.•MlAd■ss•1
2.27'
3.29"
i
P
Q our
219'
IN
a
III Q
j
G
,ArT
p vr__
qQ � �
b
_T Daw
2.IT
{ N" t
Q OdMM 1&2017 = s
&III- UAWITE In 8TH 2077 JK PROOU NI �s
SMIGLE NlJNC WINDOW ryyTnfdon F.340fnldl
1 3 aADDED]7x62 W SltetFs F.0No. assa0
'412 7 NL JK PAIR'O9 A�19LY: CP.O.stmema
�Fa 3369!!x to rTE STH ED. ZOIA FBC lF5 j!�!CQMPORM pkww N" 1013.969.9197
ILrB G. Na 9013
2014 A.W.9UILOMS ewmm"Tu no. --REVISIONS X I
\ R
° 9't599i-7d
iF V
uQk° ---------- -- -_
9NI113S(9)OMI M 9 M.9B<`ONWO 310N
C F 'N
ii Lt Z�t
WN ON1iVi0
N�
V V V IAm a?ItflMw Tfm
c Y p V SSY19a3af3d1++@l.!?!1 � i
3�YdS7pY
SSY19�IV3t8JV,S1t �
>V
a�°"� 79AV17EIhN8Mi�tiYSJ160Q
� SSVIJ 03iV3NNV 9l1
':'rT10iWAM OAd a1JR18Od SWIRIWU NOMVDUUMD NWW.NI SMSN3On VMn81Xd
1rh Y S Jwtvt0 Aa a9OiWU 39 OL 3W SMOaM VW MWWW?JORM OAd OM U M MA WJV MU*
+ 'JH2 sms YOWL am SWIS wVOd La91n8 tr.
OAd OMM ) dRla IMaaa ZZ
OAd aM�11 MAO 1Z
9 wnwsl-Eso1+ i1'8W3011O}1Mmu 6t
xtn�a 3
WOW avw 91t
tell t9 wn1Vs1•O 1t�1"D4WNMW3WOUM CL
ZNAFt,eyi�l teol Oi esn xK penaxidc 14N _ sum at S
�i Wtt7YS1•f9a9 1taW3O71O3Nt�17N VX)m 01
��SSS UUIe U 031�11V1�W 1�8W9OaOd11811 To�o"ImW 6
{ � S4V10�NdNWAlI � �OAdaI'J�t • YYO11O9 8
33VdSW OAd `DIJI?! •4 flfilJlOOi L
SiYI'JQ31V31NV.9/1 O?AAdd a IM ONMW 9
37US s
OAd ahsJlB Tug v w
v t9AVRBIM8Ad�lCftiNS.060ti Jr"� OAdMrd VSId UNacoanam 9
i ssvt�a37v3reiv.i�t1--'� (—J 3Adalala am VIMIA San Z
OAd CMIN .Sft nava t
''�` 73315 *mw dd XOiII 7
H iNVTMONsM 733ts sWs r t»s Ndd o1 x
-_ 7BusSY10 1ro.@JLmom LEM WIW %qwmftLsmn r
N 733ts SM Ndd.Ztt'Z X OI# N
a 6 `��� fNtritpi DOOM 0=<go OMS �J
73315 NfYY i•t Hdd X t d
41' 'O ION Ol JN KMN003i380NOO'MW ISd 000'£-AMNOSM 3
s r 7$15 M31iOS3137tONMAkUHOOO73Ndd.*/nxxt a
7VJMW my
3OYdSwRt I"1=!t O
DOOM SS Q=t X 9
S7YAd1YWlOT11/
a
1/4/2019 Florida Building Code Online
Al
BCIs Home Log In User Registration Hot Topics i Submit Surcharge Stats&Facts Publications Contact Us ! EC
Site Map Links Search
b'r
-`�lProduct Approval
"`° USER:Public User
r
Product Approval Menu>Product or Agplication Search>Application List
Search Criteria Refine Search
Code Version 2017 FL# 15054.18
Application Type ALL Product Manufacturer ALL
Category ALL Subcategory ALL
Application Status ALL Compliance Method ALL
Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL
Product Model,Number or Name ALL Product Description ALL
Approved for use in HVHZ ALL Approved for use outside HVHZ ALL
Impact Resistant ALL Design Pressure ALL
Other ALL
Search Results-Applications
FL# Types Manufacturer Validated By, Status
FL15054- Revision NewSouth Window Solutions Ryan J.King, Approved
R6 FL#:FL15054.18 P.E.
History Model:r.9650 Fixed Window-Impact Rated-HVHZ (813)767-
Description.Extruded Vinyl Direct Glazed"Impact"Fixed Window with Flange 6555
(0 configuration)
Category:Windows
Subcategory:Fixed
•Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission If necessary.
Contact ::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850.487-1824
The State of Florida Is an AA/EEo employer. Privacy Statement::Accessibility statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,FS.,please click e e.
Product Approval Accepts:
Credit Card
Safe
https://www.floridabuilding.org/pr/pr app_Ist.aspx 1/1
1/4/2019 Florida Building Code Online
BCIS Home Login User Registration Hot Topica Submit Surcharge Stats&Facts Publications Contact Us ` BCIS Site Map I Links Search
b
a
Product Approval
IUSER:Public User
} �rg9uct Approval Menu>Product or Application Search>Qpytication List>Application Detail
U �a Glwtt f FL# FL15054-R6
Application Type Revision
Code Version 2017
Application Status Approved
i
Comments
, I
Archived
Product Manufacturer NewSouth Window Solutions
Address/Phone/Email 4901 oak fair blvd
tampa,FL 33610
(513)284-0129
danochstein@newsouthwindow.com
Authorized Signature Vivian Wright
rickw@rwbidgconsultants.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory Fixed
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Lyndon F Schmidt
Evaluation Report
Florida License PE-43409
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2019
Validated By Ryan 1.King,P.E.
Validation Checklist-Hardcopy Received
Certificate of Independence FL15054 R6 COI (4)Certificate of IndeoenderiL f
Referenced Standard and Year(of Standard) Standard Year
AAMA/WDMA/CSA101/I.S.2/A440 2008
AAMA/WDMA/CSA101/I.S.2/A440 2005
AAMA/WDMA/CSA101/I.S.2/A440 2011
ASTM E1886 2005
ASTM E1996 2006
ASTM E1996 2008
ASTM E1996 2009
TAS 201,202,203 1994
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
FL15054 R6 Ea t v (R)_guivalencv of Standards,of
httpsl/www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDquS73Fr2ZyiPl8Ew9YUwBR2H3fjp/*2fiTNBzuDZKx5cBPf3A%3d%3d 1/5
1/4/2019 Florida Building Code Online
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 01/23/2018
Date Validated 02/05/2018
Date Pending FBC Approval 02/15/2018
Date Approved 04/10/2018
Summary of Products
j Go to Page ® Page 1/20 0
FL# Model,Number or Name Description
15054.1 a.DuraGard Fixed Window Extruded Vinyl Direct Glazed"Non-Impact"Fixed Window
utilizing a Nail Fin Installation(0 configuration)
Limits of Use — -- —— Installation Instructions
Approved for use in HVHZ:No FL15054 R6 II (j Inst 15054.1.adf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15054.1 for Design Pressure Ratings,any FL15054 R6 AE (a)Eval 15054,1,pdf
additional use limitations,installation instructions and product Created by independent Third Party:Yes
particulars.
15054.2 b.DuraGard Fixed Window Extruded Vinyl Direct Glazed"Non-Impact"Fixed Window(O
! configuration) -_-----
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL15054 R6 II (a)Inst 15054.2.odf
Approved for use outside HVHZ:Yes Verifled By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15054.2 for Design Pressure Ratings,any FL15054 R6 AE (a)Eyal 15054,2 pddf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15054.3 c.TrustSer(es Fixed Window Extruded Vinyl Direct Glazed"Non-Impact"Fixed Window
utilizing a Nail Fin Installation(0 configuration)
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL15054 R6 II (a)Inst 15054,3.Rdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15054.3 for Design Pressure Ratings,any FL15054 R6 AE (a)Eval 15054,3.pdf
additional use limitations,Installation instructions and product Created by Independent Third Party:Yes
particulars.
15054.4 d.TrustSerles Fixed Window Extruded Vinyl Direct Glazed"Non-Impact"Fixed Window(0
configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15054 R6 II (p)Inst 15054.4.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15054.4 for Design Pressure Ratings,any FL15054 R6 AE (ij)_EyqLj5054.4,pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15054.5 e.Sashlite Fixed Window Extruded Vinyl Sash in Frame Glazed"Non-Impact"Fixed
T _ - Window utilizing a Nall Fin Installation(0 configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:No FLIS054 R6 II (2)Inst 15054,5.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15054.5 for Design Pressure Ratings,any FL15054 R6 AE (a)Eval 15054.5.pdf
additional use limitations,installation Instructions and product Created by Independent Third Party:Yes
particulars.
15054.6 -' - f.Sashlite Fixed Window —— Extruded Vinyl Sash In Frame Glazed"Non-Impact"Fixed
httpsJ/www.floridabuilding.org/pr/Pr_app_dtl.aspx?param=wGEVXQwtDquS73Fr2ZyiP18Ew9YUwBR2H3fI%2fiTNBzuDZKx5cBPf3A%3d%3d 2/5
1/4/2019 Florida Building Code Online
Window(0 configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15054 R6 II (a)Inst 15054.6.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15054.6 for Design Pressure Ratings,any FLIS054 R6 AE (a)Eval 15054.6,pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars--- -- - - -- ------ — __—_-- --------- - ---- - -
15054.7 - g.DuraGard Fixed Window - - Extruded Vinyl Direct Glazed"Impact"Fixed Window utilizing a
Nail Fin Installation(O configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FLIS054 R6 11 (a)Inst 1.5054.7.12df
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See Inst 15054.7 for Design Pressure Ratings,any FL15054 R6 AE (a)Eval 15054.7.pdf
additional use limitations,Installation Instructions and product Created by Independent Third Party:Yes
particulars.
---- ----- -----
15054.8 h.DuraGard Fixed Window Extruded Vinyl Direct Glazed"Impact"Fixed Window with
Flange(0 configuration)
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL15054 R6 I1 (a)Inst 15054.8.12df
Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See Inst 15054.8 for Design Pressure Ratings,any FLIS054 R6 AE (a)Eval 15054.B.Rdf
additional use limitations,installation Instructions and product Created by Independent Third Party:Yes
particulars.
15054.9 1.4600 Fixed Window Extruded Vinyl Direct Glazed"Non-Impact"Fixed Window
utilizing a Nail Fin Installation(O configuration)
Limits of Use Installation Instructions
Approved for use In HVHZ:No FLIS054 R6 II (a)Inst 15054.9,pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15054.9 for Design Pressure Ratings,any FLIS054 R6 AE (a)Eval 15054.9.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15054.10 —J-_.4600 Fixed Window Extruded Vinyl Direct Glazed"Non-Impact"Fixed Window with
Flange(O configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15054 R6 II (a)Inst 15054.10.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See Inst 15054.10 for Design Pressure Ratings,any FL15054 R6 AE (a)Eval 15054.'10.odf
additional use limitations, installation instructions and product Created by Independent Third Party:Yes
particulars.
15054.11 —— :jk��4650 Fixed Window-Impact Extruded Vinyl Direct Glazed"Impact"Fixed Window utilizing a
ted-HVHZ Nail Fin Installation(0 configuration)
-- --------------- -- -------------------
Limits of Use Installation Instructions
Approved for use In HVHZ:Yes FL15054 R6 Ii (a)Inst 15054.11.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15054.11 for Design Pressure Ratings,any FL15054 R6 AE (c) Eval 15054.11.odf
additional use limitations,Installation Instructions and product Created by Independent Third Party:Yes
particulars.
15054.12 — — I.4650 Fixed Window-Impact Rated Extruded Vinyl Direct Glazed"Impact"Fixed Window with
- -HVHZ - Flange(0 configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FLIS054 R6 II (a)Inst 15054.12.adf
Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15054.12 for Design Pressure Ratings,any FL15054 R6 AE (c)Eval 15054.12.adf
additional use limitations,installation Instructions and product Created by Independent Third Party:Yes
particulars.
15054.13 m.9600 Fixed Window Extruded Vinyl Direct Glazed"Non-Impact"Fixed Window
https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDquS73Fr2ZyiPlBEw9YUwBR2H3fj%2fiTNBzuDZKx5cBPf3A%3d%3d 3/5
1/4/2019 Florida Building Code Online
I utilizing a Nail Fin Installation(O configuration)
Limits of Use 1 Installation Instructions
Approved for use in HVHZ:No FLIS054 R6 II (a)Inst 1054.13.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15054.13 for Design Pressure Ratings,any FLIS054 R6 AE (a)Eval 15.054 13pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars. ------ -- — - ----_ .—_..—___ __—�----
15054.14 n.9600 Fixed Window Extruded Vinyl Direct Glazed"Non-Impact"Fixed Window with
Flange(O configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL15054 R6 II (a)Inst 15054.14.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
j Impact Resistant:No Created by Independent Third Parry:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15054.14 for Design Pressure Ratings,any FL15054 R6 AE (a)Eval 15054.14.p
additional dfl use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars. —— —_
15054.15 0.9650 Fixed Window-Impact Extruded Vinyl Direct Glazed"Impact"Fixed Window utilizing a
Rated Nail Fin Installation(O configuration)
Limits of Use Installatlon Instructions
Approved for use In HVHZ: No FLIS054 R6 II (a)Inst 15054.15.odf.
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15054.15 for Design Pressure Ratings,any FL15054 R6 AE (g)Eval 15054.15.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15054.16 ' p.9650 Fixed Window-Impact— Extruded Vinyl Direct Glazed"Impact"Fixed Window with--
Rated Flange(O configuration) —
Llmits of Use Installation Instructions
Approved for use in HVHZ:No FL15054 R6 II (p)Inst 15054.16.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,RE,43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
! Other:See INST 15054.16 for Design Pressure Ratings,any FL150S4 R6 AE (c) Eval 15054.16.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
1505417— -1 Rated
9650 Fixed Window-Impact Extruded Vinyl Direct Glazed"Impact"Fixed Window utilizing a
Rated-HVHZ _ Nail Fin Installation(O configuration) — _ —
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15054 R6 11 (g)Inst 15054.17.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15054.17 for Design Pressure Ratings,any FLIS054 R6 AE (C)Eval 15054.17.pd
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15054.18 r.9650 Fixed Window-Impact Rated Extruded Vinyl Direct Glazed"Impact"Fixed Window with
-HVHZ Flange(O configuration)
Limits of Use Installation Instructions
Approved for use In HVHZ:Yes FLIS054 R6 II (a)Inst 15054.18.gdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15054.18 for Design Pressure Ratings,any FL15054 R6 AE (g)Eval 15054.18.pd1
additional use limitations, installation Instructions and product Created by Independent Third Party:Yes
particulars.
15054.19 — s.4800 Twin Mulled"Common Jamb" Extruded Vinyl Direct Glazed"Non-Impact"Integral Mulled
Fixed Window "Common Jamb"Twin Fixed Window with Flange(0/O Vertical
or Horizontal configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ: No F1,15054 R6 II (a)Inst 15054.19.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15054.19 for Design Pressure Ratings,any FL15054 R6 AE (a)Eval-15054,19.pdf
additional use limitations,installation Instructions and product Created by Independent Third Party:Yes
particulars.
httpsJ/www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquS73Fr2ZylPl8Ew9YUwBR2H3fj%2frTNBzuDZKx5cBPf3A%3d%3d 415
114/2019 Florida Building Code Online
15054.20 t.4800 Mulled"Common Jamb" Extruded Vinyl Direct Glazed"Non-Impact"Integral Mulled
Fixed Window "Common Jamb"Triple Fixed Window utilizing a Nail Fin
Installation(0/0/0 Vertical or Horizontal configurations)
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL15054 R6 II (a)Inst 15054.20.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:-No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15054.20 for Design Pressure Ratings,any FL1S054 R6 AE (P)Eval 15054.20.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
Go to Page —�----------_--_--------------- ---------- ----— � � Page 1/2
[i,u to Ncxl
Contact Us::2601 Blair Stone Road,Tallahassee Fl.32399 Phone:850-487-1824
j The State of Florida is an AA/EEO employer.Copyright 2007.2013 State of Florida.::Privagy,Statement::Accessibilitv,Statement::Refund Statement
I
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 4S5,F.S.must provide the Department with an email address If they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
nYa.
I
Credit Card
Safe
https://www.floridabuilding.org/pripr_app dtl.aspx?param=wGEVXQwtDquS73Fr2ZyiPlBEw9YUwBR2H3f*/a2iiTNBzuDZKx5cBPf3A°/a3da/o3d 5/5
trot rr,.
.." ice: m
i O
[ENewsouth
WINDOWSOLUTIONs
61"MN(OVERALLRN WIDTH '�i4,•'
4901 Oak Fair Blvd.,Tampa,FL 33610 60'" OPLL FBnME:M Z
5 o gi{
\ z v
\V �N4 9m=a
9650 Fixed Window
�z
Impact Rated - HVHZ Uz
W/ Flange z (33
cl
GENERAL.NOTES �
ii F W
I. M product hos been evoluoted and is in compliance With the 6th motion(2017)Florida
Budding Code(FBC)structural requirements including the High Velocity Hurricane lona'
J'
(HVHZ). < K
c � U
2. Product anchors shall be as rated and spaced as shown on details.Anchor embedment to m
base material shall be beyond won dressing or stucco. a
a a
3. When used in the°HVHZ'this product complies with Section 1626 of the Florida Building Code
and does riot require an impact resistant covering.
� U
4. When used in areas outside of the HVHP requiring wind bome debris protection it*product
complies with FBC Sections 1609.12&R301212 and does not require an impact resistant
covering.This product meets missile level'['and includes Wind Zone 4 as defined in ASTM $o
E1996 and FBC Sections 1609.122&R3012-Ul.
5. For 2x stud framing construction,anchoring of these units shad be the some as that shown for 0
e
$ 2x buck masonry construction.
s 6. Site condifiors that deviate from the details of this drawing require further engineering anotysis
by a licensed engineer Or registered architect. NOTE:VERTICAL ORIENTATION SHOWN(HORIZONTAL ORIENTATION ALSO APPROVED) _
7. This product meets water infiltration requirements for'HVHr. MAIL OVERALL MAX OVERALL MAX GLASS OFSlGN PRESSURE
g FLANGE FRAME DAYLITE (PSF) N N Q
rz TABLE OF CONTENTS DIMENSION DIMENSION DIMENSION TYPE NEQ o m
F42
f 37.1'
DESCRIFFION X73.1- 76.0'X 72.D' 31.75 X 67J5' Gt +70.0 7Q0
Typical elevations,design pressures&general notes
-
o�m 6126115
=
Horizontal aoss sections 611
.'X85.1' 60.0"X44. 55.75•X79.75' G2 +60.0 -60.0 SME N.T.S.
Horizontal cross sections MM0" SMEw JK m
Buck anchoring am BY, LFS Frame anchoring Bill of materials.-components&glazing details --- - Note:This product is not approved for use above 30 feet in the°HVHP. FL—t 5054.to o
e N
son 1 a 6 C
a
a
MCdetdsVdm Sou1fi Windays PENaAN0r1W-NolfaU ProduR WP�sVI-1Sost FcadlC.pt�.in�t.150S10017N�1S0%Isdeg,2.2
• • .d
r
.F-- 7
T
' N
+ N
� N W
v
Z
N
N 2.a
i N
C")M.
�1
i
W d •
• d g A ry
In
r
N
r
N p
`��tNtlllllll////'I
4 '
No.43�09
OcwW1$2017S e,
PROOUCF.
e� p tyld, F.Schmidt
4 NdrSouth p.E Ne. 43409
g y ONi 27 UPDATE TO BTM ED. 2077 FBC JK PARr OR Y: SUILDIN9 CONSULTANTS. IND.
1 9 6 16 AWW ALT. HORlZON7AL �Yy P.O. Sox 230'VbMw, rl 3S693
m N NO DATE, CROSS SECTIONS Phonw N04 813.669.9197
FOPE CA. No. 9813
O 3Ol 0 R.W.EWLDING CONMLTANM IND.
1 0
,tpt * t
K H01E.gmetMetdsaemwA 1-11�MRd
f ftougag le of 3ltreads gig nyp�h Maid C 1 y * 2I:
INMR
C 1 �tv g°�I n
Oil
Nrazlog 12
12
tt p Y
12 • .• 9
o
Tf
2
o
b a
b G1 G2
n b E 2
ExleeoR
9 2 Gl G2 . 3 Mom D"dtoM Ony
r b SECT ON MOM
3 +W/sleets►udreen�o�on
E
MAX,DESIGN PRESSURE FOR ALTERNATE A
MB.�lj d ANCHORING LOCATION SHOWN ON THIS SHEET c
±65 PSF(UP TO 36"X 7T FRAME SIZE)
a L 1 t50 PSF(UP TO MY X84"FRAME SIZE) 1
KmfjoR
H
R y
`
12 • 12
0
v
.• pp
• O• D1
q w
G1 G2 I-Ilf'M1N. 2 G1 G2 —1 N.T.S.
E LFS
/-l-N NOW NlAL CR S ON 2 R L C O SE ON °7�O'd e
Ft—f505L18 n
- - efu 3_a'_L
'.MI�Jr1Y1.'1mXgD gNIGTIf1A'!It'M L t Oi Q
vivo-N yo 'JA47lOFgNV
Lets•ato•rto-ON�.geyd
rG'9Cr Zi'ggY[q1{OCL8 Nott ?lOifONY't7Y 4900Y 9t 9 6 t V1 X
,``11�11�1f1/!fq/ 1V1SN00 OPR01H1i •A�811 k1' am LCOS Hl9 91 31YOdtf l
`��� '.�' ,. �i✓� iPao", :��PttR'1 y�nggntyN ••tDMtOild 3 tl
t t L3PZ'�t�9nPA
� I '
NAII
A o'O%VW.LI
I
�► i. {'dilly
'70xvw sl
is
-+ x y9 6 !
_i,
? op all i
a:•ra.Pst•Kosr-vttccat►rsosr-tn�w+o-�u+�+sosc-��+acrav��rl•wnari.wn�a�.�an+untaros�rrWu+ro�ro
MO*W�W"saw W[fW*M PU0AANRiM-Raft M)dUCIAXMRWL-1$M WodkC.
S4 14
car
SL
PC Co
- .4n. .
111MMO.0
mea
11-MAXOQj
-
.0C",
? \
jr %
1A.
Ookboria I
N+rSolrth PSE Ift.43W
ffiff OR ASSDMLY,, lllWiIII
FPAVC Aw'15==10,Vchim.FL 33M
ANCHOM
Fa 0.
1FNLOFMATERfA15
119A� DBClIl4lDM WiH1At .`��� �� .6I in
A IX BUCK x 0 WOOD
B 2X B K x WOOD
C 1/4 MAX.SHIM SPACE - 0
D I/4X2%VCPHiELCOORIIWCONCRETESCREW STEEL oo y� rf
E �MA9CM TRY-3AOD 1 OR HOLLOW BLOCK GTO ATO ACF CONCRETE �4 * ,����� � j
F NTOXTPPH 1-T MIN � nn 0062 I Og�� rrrrnf^ 8 -
G 1/4"X 3-IX NIMH ELCO OR ITW CONCRETE SCREW STEEL D F� g
H 1/4 X 23/4 HWH ELCO OR FTYU CONCRETE SCREW STEEL
J STEELSTUD .033' A653GRADE33 Id .FLn45 STEL Z G BEAD
K #10PPHSEIF4RBIINGSMS S11H
L #I0XrPFHSf4(I-l)rMIN.EM[BEDMENQ STEEL
1 EXTRUDED VINYL FRAME RIGID FVC �� a
2 1 EMDED VINYL GLAZING BEAD • RICA PVC
12 1 FRAME ADAPTER RIGID PVC
6 •TFE APPROVED WHBE RIGID PVC EXTERIOR DRR1JSlOW FOR WINDOWS AREM BE PRODUCED BY
EXTRUDERS LKSMEES IN AAMACER11FICATION PROGRAMS FOR ROD PVC FX1R1=Ns..
aw
Fes---2.06'
� Z
I g
ISM
Irr 1�
ctA551�E chin BR
GlA&*SE UANT GLAR1GSEAL W 8 a
ls1cAF>ETLssil 7/8'O A GlAsS IHK (51CAFlF)cds217kAWM.SPACER
'0.&GLASS THK
f 7
IMANNEA1EDGLASS I)TANNEAIIDGLAM
0.010'SARW PVB NOLAYER O.IOS'SEN RYGLASSIN16BAYER
1/V ANNEALED GLASS I)T ANNEAM GLASS
AM SPACE AIRSPACE
118'MNEAIIDGU►a Iff ANNEALED GLASS ^H
ALUM.SPACER 01 3
N. u
am
V26115
15 L
G1i G G GiA191GDlTAB
uH.T.S.oftn: .1K ■
orc x LFS 3
auw�Ma: a
- ---- - --- -- -
NOTE:GLAZINGa96'WDEREQUIRES TWO PSETTING BLOCKS CONFORNWGTO FBC SECTION 241123.1
--- - - R-15054.1 B
n
so}*J---p-jo
: