Loading...
HomeMy WebLinkAboutProduct Approval-Roof Underlayment RZcA, 41,4) PerstmrittEt u::le2Dee6oPuo?nr .9.nt - - t4106.4k#0501°P ' • "4' Busitiess4 ProlessianaIRetutalicip---;-1 acts Home log In User Registration Hot Topics I Submit Surcharge Stats&Facts Publications PBC Staff 13CtS Site Map links Search; d bih lin Product Approval r: USER:Public User eig-r.S.V.VrotWr Product Approval Menu>Product or Application Search>Application Int>Application Detail trptArP7Z 1-=*- FL# FL12328-R8 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer TAMKO Building Products,Inc. Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri_eden@tamko.com CI) Authorized Signature Kern Eden (J) kerri_eden@tamko.com 11'1 Technical Representative Kern Eden Address/Phone/Email PO Box 1404 tall=L1 Joplin,MO 64802 loarn (417)624-6644 Ext 2305 kerri_eden@tamko.corn Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Zachary R.Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LW Quality Assurance Contract Expiration Date 01/07/2019 Validated By Locke Bowden P.E. 5- Validation Checklist-Hardcopy Received Certificate of Independence FL12328 R8 COI TBP14001.4 20 7 FBC Eval Report TAMKO Underlayments final.ndf Referenced Standard and Year(of Standard) Standard Year ASTM 01970 2015 ASTM 0226 2009 ASTM D4869 2016 ASTM D6380 2003 TAS 103 1995 Equivalence of Product Standards Certified By 1 11 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/05/2017 Date Validated 10/19/2017 Date Pending FBC Approval 10/20/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description , - 1 12328.1 ASTM Slate Surfaced Roll Roofing Roll roofing surfaced with mineral granules Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO Approved for use outside HVHZ:Yes Underlavments final.odf Impact Resistant:N/A Verified By:Zachary R.Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes , Other:See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO Underlavments final.pdf i I Created by Independent Third Party:Yes 12328.2 ASTM Tile Underlayment Coated organic underlayment Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO Approved for use outside HVHZ:Yes Underlavments final.pdf Impact Resistant:N/A Verified By:Zachary R.Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO Underlavments final.pdf Created by Independent Third Party:Yes 12328.3 Master Smooth Asphalt saturated organic underlayment. ' Limits of Use Installation Instructions Approved for use in HVHZ:No FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO Approved for use outside HVHZ:Yes Underlavments final,odf Impact Resistant:N/A Verified By:Zachary R.Priest 74021 I Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 B _ AETBP14001.4 bitumen40Ol.42underlayment.nRte.port TAMKO Underlavments final.pdf Created by Independent Third Party:Yes 1 12328.4 Moisture Guard Awa2dh eRringmodified Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL12328 R8 II TBP14001.4 2Q17 FBC Eval Report TAMKO Approved for use outside HVHZ:Yes Underlavments final.pdf I Impact Resistant:N/A Verified By:Zachary R.Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO Underlavments final.Ddf Created by Independent Third Party:Yes 12328.5 No. 15 ASTM Asphalt saturated organic felt Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL12328 REI II TBP14001.4 2017 FBC Eval Report TAMKO Approved for use outside HVHZ:Yes Underlayments final.pdf , Impact Resistant:N/A Verified By:Zachary R.Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports ,I FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO Underlavments final.pdf Created by Independent Third Party:Yes 12328.6 No. 15 UL Asphalt saturated organic felt Limits of Use Installation Instructions i Approved for use in HVHZ:Yes FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO Approved for use outside HVHZ:Yes Underlavments final.pdf , I -------. ii Impact Resistant:N/A Verified By:Zachary R.Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001,4 2.017 EBG Eval Report TAMKO Underlavments final.pdf Created by Independent Third Party:Yes 12328.7 No.30 ASTM Asphalt saturated organic felt Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL12328 R8 IT TBP14001.4 2017 FBC Eval Report TAMKO Approved for use outside HVHZ:Yes Underlavments flnal.pdf Impact Resistant:N/A Verified By:Zachary R.Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO Underlavments final,odf Created by Independent Third Party:Yes 12328.8 No.•30 UL Asphalt saturated organic felt Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL12328 RB II TBP14001,4 2017 FBC Eval Report TAMKO Approved for use outside HVHZ:Yes Underlayments final.odf Impact Resistant:N/A Verified By:Zachary R.Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO Underlavments finai.DdF Created-by Independent Third Party:Yes 12328.9 TAM-FELT Alternate to ASTM D 226,Type II underlayment Limits of-Use Installation Instructions Approved for use in HVHZ:Yes FL12328 RB II TBP14001,4 2017 FBC Eval Report TAMKOI Approved for use outside HVHZ:Yes Underlavrrients final.pdf Impact Resistant:N/A Verified By:Zachary R.Priest PE-74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL1232.8 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO Underlavments final,odf Created by Independent Third Party:Yes 12328.10 TW Metal and Tile Underlayment self-adhering modified bitumen underlayment Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL12328 RB IT TBP14001,4 2017 FBC Eval Report TAMKO. Approved for use outside HVHZ:Yes Underlavments final.pdf Impact Resistant:N/A Verified By:Zachary R.Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE.TBP14001,4 2017 FBC Eval Report TAMKO Underlavments final,odf Created by Independent Third Party:Yes 12328.11 TW Underlayment self-adhering modified bitumen underlayment Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL12328 R8 II TBP14001.4 2017 FBC Eval Reoprt TAMKO Approved for use outside HVHZ:Yes Underlavments final.odf Impact Resistant:N/A Verified By:Zachary R.Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO Underlavments final.pdf Created by Independent Third Party:Yes Back 'Next' Contact Us::7601 Stair Stone Road,Tallahassee FI,32399 Phnne:850-487-1024 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida,::Privacy Statement::-Accessibility tatement::fefund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall,If you have any questions,please contact 850.487.1395.•Pursuant to Section 455.275 (1);Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one,The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please" dick bere Product Approval'Accepts: 17-7-71 ll eCrici ! Certcate of Authorization No. 29824 _ , . r.[ CREEK 17520 Edinburgh Drive Tampa,FL 33647 _.. TECHNICAL SERVICES, LLC (813)480-3421 1 EVALUATION REPORT FLORIDA BUILDING CODE,6m EDITION(2017),' I Manufacturer: TAMKO BUILDING PRODUCTS, INC. ;Issued October 19, 2017 P.O. Box 1404 Joplin, MO 64802 (417)624-6644 http:l/www.tamko.com Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing ' Subcategory: Underlayments Code Sections: 1507.1.1 Properties: Physical properties PRODUCT DESCRIPTION i TAMKO®ASTM Slate ASTM D 6380,Class M,Type II underlayment constructed from organic felt saturated Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules. TAMKO®ASTM Tile ASTM D 6380, Class M,Type II underlayment constructed from an organic felt saturated Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules. . TAMKO®Master ASTM D 6380, Class S,Type IV underlayment constructed from an organic felt saturated I! Smooth with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For � use in non-HVHZ only. TAMKO®Moisture 'Self-adhered, ASTM D 1970, fiberglass reinforced; modified bitumen sheet membrane Guard® with a mineral.surfacing and a removable release film on the adhesive side and removable selvedge release tape. TAMKO®No.15 ASTM ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt TAMKO®No. 15 UL ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt Organic Felt TAMKO®No.30 ASTM ASTM 0 226,Type II underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt Organic Felt TAMKO®No.30 UL ASTM D 226,Type II underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt TAMKO®TW Metal and Self-adhered,flexible, ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side. TAMKO®TW Self-adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a Underlayment polymer film on the surface and a removable release film on the adhesive side. l TBP14001.4 FL12328-R8 Page 1'of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. �—�----� '| i ������ TAMKO BUILDING PRODCUTS,INC: QC� 1 m�~0��0�"��*��� T»moKOVnd»davmxnts '� TECHNICAL SERVICES,LLC TAMKO®TAM-FELT Alternate to ASTM D 226,Type I and Type U underlayment constructed from a non perforated organic felt that is saturated with asphalt. ] APPLICATION METHOD ] Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the | requirements below. I | Deck substrates shall be clean, dry, and freefrom irregularities and debris. fasteners Alletenomin theshalldockbe,' checked for protrusion and corrected prior to underlayment application. / The roof deck shall be constructed of cl . Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting joints. ' The mini |icoU shall 50°F follows: . a) The minimum application temperature of TAMKO®TW Metal and Tile Underlayment and TAMKO®1W I Und \ nLoho||bn4O^F� —r� — | b) The minimum application temperature of TAMKOO Moisture Guardl shall be 35°F. mo[slope shaUbeinaccordance v��FBCne requirements ' The minimum � | a) The minimum slope of TAMKO®ASTM Slate Surfaced Roll Roofing shall be 2:12. Underlayments shall be exposed in accordance with the manufacturer's nanommondationo, but in no case shall exposure exceed 30 days Exception: TAMKOc 1W Metal and Tile Underlayment may be exposed for a maximum 90 days. Self-adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ. 1 . All roof coverings shall be mechanically fastened through the underlayment to the roof deck. Allowable Roof Coverings: � Metal Roof Mineral Wood Asphalt Panels and Surfaced Roll Shingles and Slate Clay u unuenaymmm Shingles Shingles Roofing Shakes Shingles Concrete Tile | TAmKmmASTM Slate / v N N N N Y oun�vodm�|noonng | ' , | TAMKO®ASTM Tile N N N N N Y unuonavrn*nt ) .| TAmKOCD Master Smooth Y' N N N N N / , T4Mmo@Moisture ouard@ r N N N N N ! TAMKO@ No.15 ASTNI Asphalt Saturated Organic Y Y Y vu N N Felt / TAmmo@No.1muLAsphalt v v Y Ya Y N Saturated Organic Felt , TvMn00No.uoASTM Asphalt Saturated Organic Y Y v Y Y v Felt '' TAMKO No.30 UL Asphalt Y Y Y N Y N . Saturated OrgFelt 1 Txmandn� '. ' Metalv v N N N Y unuewuy�rn | TAMKOO TW Underlayment Y Y N N N N TmwmOVTAM-FsLT v N N N N N Notes: �openvan ouatimmper 1507.2.e2 ` | 2)Wood shinles only TBP14001.4 FL12328-R8 Page om* ` Floridaproductppmvounu�Rv�s1G2V� The manufacturershallnotify CREEK Technical Services,LLC of any product changes or qualitychanges throux utmadunmnnxxwmmhm/sn:pouixna|m. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not , specifically addressed herein. ' . 1 . '/ . � � . ., . CREEK• n�m BUILDING! Underlayments __ _ __ ��-: . TECHNICAL SERVICES,LLC UMITAllONS 1) Fire Classification is not within the scope of this evaluation. 2) Wind uplift resistance 3) Installation of the evaluated product shall comply with this report,the FBC, and the manufacturer's publishedl application instructions, Where discrepancies exist between these sources, the more restrictive and FBC1 compliant installation detail shall prevail. , 4) Contact the manufacturer when installing at temperatures below the minimum application temperature: , 5) Unless otherwise stated,the minimum roof slU op�uhoboinoccondmncomithFBC,equimmontu. ` 6) All underents shall be installed with the roll length parallel to the eave, starting at the eave, and ld ' in successive courses installed up the deck in a manner that effectively sheds water from the deck. End ' laps shall be staggered between courses in accordance with the manufactrer's alication instructions. ,i 7) The underlayment may be used as described in other current FBC product approval documents. 8) The underlayment shall not be installed over existing roof coverings. / 9) Contact the manufacturer regarding specific exposure limits for each underlayment 10) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. REFERENCES | . Entity ReoorNo �nndomd Year PR Construction Materials TAP-192-02-01 ASTM o197u 2015o PR Construction Materials TechnolTAp' 93-02-01 ASTM D 1970 2015a ! PR Construction Materials Technologies TAP:-214-02-01 ASTM o4VVo 2016 PR Construction Materials TechnoloieTxp-215-02o1 ASTM D 22 2008 | PR Construction Materials Technologies TApa16-02-03 ASTM o6uuo 2003(2013) PR Construction Materials Technologies T*p'217-02-01ReV ASTM D 6380 2003(2013) 1 PR Construction Materials Technologies TAP-218'02'01 ASTM D 22e 2009 PR Construction Materials Technologies rAp'219-02-01 ASTM oocn 2009 , PR Construction Materials TechnoloT�P�uu'n�o1 ASTM�nouu oon*�n�n> '-PR Construction Materials Technologies TAP-222-02-01 ASTM D 4869 2016 i PR Construction Materials Technologies(TST6049TAP-245-02-01 TAS�Vu 1995 �\ / ASTM o*7en 2011 PR Construction Materials Txp-311-02-01 ASTM o,n7o 2015a .\ PR Construction Materials TAp-319-02-011 ACC 188 2012 PR Construction Materials TnPa87-02-01 ASTM D 1970 2015o PR Construction Materials Technologies(TST6049) T*p'388-02-01 ASTM 0 1970 2015o ` / ' UL LLC(TST9628) 13CA12269 ASTM Duus2009 | , i I ' i / , | • | | �| � / \ } '' ! , / | . | / . TBP14001.4 FL12328-R8 Page nm« / This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK 1 Technical Services,LLC of any product cha =g" throughout is valid. This evaluatireport does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. , | .1 | - �� -�-� — -�� --- CREEK BUILDING PRODCUTS,INC. TAMKO Underlayments TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6m Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. 0‘‘ •( ``‘ •n n►►,,ite ,•`G�P�G E N•pR� F�-.. 201 7.10.1 9 11 No 74021 = - 12:15:58 • -04'00' 10• • 'N•' :c( P,�\_ � Zachary R.Priest, P.E. �i�S'• • R�.• ' C? �` Florida Registration No.74021 Organization No.ANE9641 ,l CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 11 END OF REPORT TBP14001.4 FL12328-R8 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not specifically addressed herein.