Loading...
HomeMy WebLinkAboutProduct Approval BCIS Home Log In User Registration Hot Toga Sutanit Surcharge Stats&Facts Publications Contact Us i BCIS Site Map Unks Search Florida t� J Product Approval 1 USER:Public User Product Aonmval Mem">P-&ct or Annlicatfon Search>ADAh[atiOn I 15>Application Detail FL# FL18355-114 RECEIVED Application Type Revision Code Version 2017 FEB 2 6 2.019 Application Status Approved ST. l_ycie count t fa�rml In Comments __�.._..__ -. Archived C Product Manufacturer TAMKO Building Products,Inc. Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri_eden@tamko.com Authorized Signature Kerrl Eden kerri_eden@tamko.com Technical Representative Kerri Eden Address/Phone/Emali PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri_eden@tamko.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 01 iJ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Zachary R.Priest the Evaluation Report U, Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 01/07/2019 Validated By Locke Bowden P.E. 1- Validation Checklist-Hardcopy Received Certificate of Independence FL18355 R4 COI TBP15001 4 7017 FBC Fval Report Shingles final prif Referenced Standard and.Year(of Standard) Standard Year ASTM D 3161 2016 ASTM D 3462 2010 ASTMD D 7158 2011 TAS 100 1995 Equivalence of Product Standards Certified By Approved Testing Lab FL18355 R4 Eauiv UL.letter for standards for FBC 2017.ndf Sectlons from the Code Product Approval Method Method 1 Option D Date Submitted 09/25/2017 Date Validated 09/27/2017 Date Pending FBC Approval 10/08/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 18355.1 Glass-Seal,Elite Glass-Seal, ASTM D 3462 asphalt shingles and hip and ridge shingles Heritage,Heritage Premium, Heritage Woodgate,Heritage Vintage,Hip and Ridge,and Vintage Hip and Ridge Shingles Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL18355 R4 II TBP15001.4 2017 FBC Fval Report Shlonies Approved for use outside HVHZ:Yes finalmdf Impact Resistant:N/A Verified By:Zachary R.Priest PE-74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL18355 R4 AE TBPS 001.4 2017 FBC Eval Report Shingles final.ndf Created by Independent Third Party:Yes Back N® Contact Us::2601 Blair Stone Road.Tallahassee FI 37399 phone:850-487-1824 The State of Florida is an AA/EEO employer.Coovrioht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-ma0 address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please dick here. Product Approval Accepts: 0®® Kttid z Credit Card Safe Certificate of Authorization No.29824 17520 Edinburgh Dr CREEK Tampa,FL 33647 TEctiNICAL SF-RvicF-s, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODET,137H EDITION(2017) Manufacturer: (,IAMKO BUILDING PRODUCTS Issued September 25,2017 226—West 4 Street Joplin,MO 64801 (417)624-6644 Manufacturing Plants: Joplin,IMO, Phillipsburg,KS Frederick,MD Dallas,TX Tuscaloosa,AL Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing'----, Subcategory: Asphalt Shingles) Code Sections: 1-564.-1-1�-16-677.2.5,1507.2.7.1,1523.6.6.1 Properties: Physical properties,Wind Resistance,Wind Driven Rain REFERENCES 9n& Report No. Standard Year PRI Construction Materials Technologies(TST5878) TAP-043-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-051-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-054-02-01 TAS 100 1995 PRI Construction Materials Technologies(rST5878) TAP-114-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-117-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-130-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-131-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-165-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-280-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-303-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878)' TAP-307-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-314-02-01 Rev 2 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-315-02-01 ASTM D 6381 2008(2013)e1 PRI Construction Materials Technologies(TST5878) TAP-317-02-01 TAS 100 1995 UL LLC(TST9628) 02NK9507 ASTM D 3161 2016 UL LLC(TST9628) 04NK24366 ASTM D 3462 2010A UL LLC(TST9628) 05NK28005 ASTM 0 6381 2008(2013)e1 UL 2390 ASTM D 7158 2011 UL LLC(TST9628) 06NK03898 ASTM D 3161 2016 ASTM D 3462 2010A UL LLG(TST9628) 08CA59132 ASTM D 3161 2016 UL LLC(TST9628) 09NK07896 ASTM D 3161 2016 ASTM D 3462 2010A UL U-C(TST9628) I0CA50498 ASTM D 3462 2010A UL LLC(TST9628) 1 OCA64882 ASTM D 3161 2016 UL LLC(TST9628) IINK14014 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC(TST9628) 12CA24551 ASTM D 3161 2016 UL LLC(TST9628) 4786110643 ASTM D 6381 2008(2013)el UL LLC(TST9628) 4787043762 ASTM D 3161 2016 UL LLC(TST9628) 4787148748 ASTM D 7158 2011 ASTM D 3161 2016 ASTM D 3462 2010A CREEK Technical Services LLC(ANEI 1669) TBP15001.3 Calculations 2017 T131215001.4 FL18365-R4 Page 1 of I I This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. TAIVIKO BUILDING PRODUCTS -4CREEK Asphalt Shingles TECHNICAL SERVICES,LLC PRODUCT DESCRIPTION Elite Glass-Seal® 12-1/4"x 36', ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 34ab (Frederick,Joplin& asphalt shingle with fiberglass mat coated on both sides With asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass-Seal 12-1/4"x 36', ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass-Seal 12-1/4'x 36,ASTM D 7158,Class H self-sealing,3-tab asphalt shingle with fiberglass (Joplin) mat coated on both sides with asphalt and surfaced with ceramic granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. HeritagelD 13-1/4* x 39-318", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas,Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Joplin,Phillipsburg& complying with ASTM D 3462. Tuscaloosa) Heritage@ Premium 13-1/4' x: 39-318", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas,Frederick, reinforced, laminated architectural asphalt shingle surfaced With mineral granules Phillipsburg& complying With ASTM D 3462. Tuscaloosa) HerltageO Premium 12" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Frederick) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. HerltageO VintageS 17-1/2"x 40",ASTM D 3161,Class F and ASTM ID 7158,Class H fiberglass reinforced, (Phillipsburg) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage@ Woodgete 13-114" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas&Frederick) reinforced, laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage@ Woodgate 12; x: 36-3/8*, ASTM D 3161, Class F fiberglass reinforced, laminated architectural (Frederick) asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Hip and Ridge Shingles 12-1/4' x 12', ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt (Frederick&Joplin) shingle surfaced with mineral granules complying with ASTM D 3462. VintageQ Hip and Ridge 12'x 12*, ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle (Phillipsburg) surfaced with mineral granules complying with ASTM D 3462. TBP15001.4 FL18355-R4 Page 2 of 11 This evaluation report is provided for State of Florida product approval under Rule 6IG20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. — CREEK TAMKOBUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES,LLC INSTALLATION Elite Glass-Seal® Basic Wind Speed(Vwo: Max 194 mph (Frederick,Joplin& Basic Wind Speed(V,,d): Max. 150 mph Tuscaloosa) Deck(HVHZ): In accordance with FBG requirements; & Solidly sheathed min. 19/32 in. plywood or wood plank for Glass-Seal new construction; Min. 15/32 in. plywood existing (Frederick,Joplin(Non- construction. HVHZ)&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min.7/16 in.OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): Installed with 5-1/8 inch exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using T Nail Pattern" detailed below. Installation .(Non-HVHZ): Installed with 5-1/8-inch exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattem"detailed below. NAILS w Nailing- Area ailing Area --------- ------------ ---------- - 5-118" Butt Edge Figure 1. Elite Glass-Seal&Glass-Seal 4 Nail Pattern(Non-HVHZ only) NAILS Nailing -- - z-......._...... ........-....-- .._�. - 6-78° Area _...._ - ....._...... -.....�_ _..... _ 5.118" Butt Edge Figure 2. Elite Glass-Seal&Glass-Seal 6 Nail Pattern TBP15001.4 FL18355-R4 Page 3 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. [MCREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES,LLC Heritage& Basic Wind Speed(V„�: Max. 194 mph (Dallas,Frederick,Joplin, Basic Wind Speed(Vasd): Max.150 mph Phillipsburg&Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 19132 in. plywood or wood plank for Heritage®Premium new construction; Min. 15/32 in. plywood existing (Dallas,Frederick construction. Phillipsburg&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 15132 in. plywood or wood plank-for Heritage®Woodgate new construction;Min.7/16 in.OSB existing construction. (Dallas&Frederick) Undedayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): Installed with 5-5/8 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ):. Installed with 5-5/8 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be-attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. FASTENERS NAIL ZONE COMMON BOND 6-118" E URE E-E/8" 12-11211 12-3/8"' h--1" Figure 3. Heritage%Heritage®Premium,and Heritage®Woodgate(Dallas) 4 Nail Pattern(non-HVHZ only). FASTENERS NAIL ZONE COMMON BOND EXPOSURE 5-518" i�%� �4-7-i/2"i�-7-1/2°-�t-7�/8"-�4-7-1f2"-►N-7-1/2`� ��-1" _ Figure 4. Heritage®&Heritage®Premium .6 Nail Pattern TBP15001 A FL18355-R4 Page 4 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall-notify CREEK Technical Services;LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. CREEK Tan�Ko BUILDING PRODUCTS Asphalt Shingles fpiIIIIIIIIIII TECHNICAL-SERviCEs,LLC NAIL ZONE/ ASTENE- COMMON BOND T ExQOSURE 5 SW 1L4 �7-1/2+7-1/2+-N+-1/21+74/211101 �1-1" Figure 5. Heritage®Woodgate 6 Nail Pattern -►�t�tiai.—l2-i/2°._—� •�---12-i/2"-=--+ii°j1'�+= I " ; i Common Bond ( ; FASTENERS ; I r +. cb a i _ ff -— 39-30 i Figure 6. Heritage®,HeritageO Premium,&Heritage@ Woodgate Alternate 6 Nail Pattern, PAINT LINE. NAILZONE -.,EDGE OF 6-1/su COMMON . BOND EXPOSURE 5-518" ACCEPTABLE FASTENER LOCATION 00 NOT FASTEN ALONG EDGE OF COMMON BOND PREFERRED FASTENER LOCATION Figure 7. Heritage@(Tuscaloosa) Expanded Nail Zone Nail patterns from Figures 3,4,and 6 may be placed In the nail zone as described above TBP15001 A FI-18365-R4 Page 5 of i 1 This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Techhical Services,LLC of any product changes or quality assurance changes throughout the duration Tor which this report Is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. TAUKO BUILDING PRODUCTS aCREEK Asphalt Shingles TECHNICAL SERVICES,LLC HeritageV Premium Basic Wind Speed(Vwt): Max. 194 mph (Frederick) Basic Wind Speed(Vasa): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction;Min.7116 in.OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. . Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation Instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. NAIL ZONE/ FASTENERS /COMMON BOND 6'12 EXPOSURE 5u no 1 lit 1" � -- lin 12u 111 Figure 8. Heritage@)Premium(Frederick) 4 Nail Pattern(non-HVHZ only) NAIL ZONE! FASTENERS& COMMON BOND T T51/211 U —LL S I RE 5n Figure 9. Heritage@ Premium(Frederick) 6 Nail Pattern TBP15001.4 FL18355-R4 Page 6 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. yr TAMKO BUILDING PRODUCTSCREEK Asphalt Shingles TECHNICAL SERVICES,LLC Heritage®Woodgate Basic Wind Speed(Vut): Max 194 mph (Frederick) Basic Wind Speed(Vasd): Max.150 mph Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction;Min.7/16 in.OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nall Pattern'or"6 Nail Pattern'detailed below. NALZONEI FASTENERS COMMON BOND # - I qT EXPOSURE V' Figure 1O. HeritageOWoodgate(Fredenick) 4-Nail Pattern(non-HVHZ only) NAIL ZONE/ COMMON BOND z�n[ASTENERSjZ:jr r "lir EXPOSURE So Figure"11. HeritageSiWoodgate(Frederick) 6 Nail Pattern TBP15001A FI-18366-R4 Page 7 of 11 This evaluation report is provided for State of Florida product approval under Rule 6IG20-3: The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report don not express nor imply warranty,installation,recommended use,or other product attributes-that are not specifically addressed herein. TAMKO BUILDING PRODUCTS [MCREEK Asphalt Shingles TECHNICAL SERVICES,LLC Heritage@ Vintage® Basic Wind Speed(Vut): Max. 194 mph (Phillipsburg) Basic Wind Speed(Vase): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new *construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15132 in. plywood or wood plank for new construction;Min.7/16 in.OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern' detailed below. Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"5 Nail Pattern"or'6 Nail Pattern"detailed below. 4W ]EXPOSUM %h 6" Famners Fha are - -— — —— — —— — — — - - — 17.1/24 51 Expasum t 9 1W Figure 12. HeritageV Vintage(& 6 Nail Pattern(non-HVHZ only) hot& MOMS + Figure 13. Hedtage@ Vintage 6 Nail Pattern TBP1 5001 A FI-18366-R4 Page 8 of 11 This evaluation report Is provided for State of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK Technical Services.LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. TAMKO BUILDING PRODUCTS CREEK Asphalt Shingles TECHMCAL SERVICES,LLC Hip&Ridge Basic Wind Speed(Wit): Max. 194 mph (Frederick&Joplin) Basic Wind Speed(Vaw): Maio 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction;Min.7/16 in.OSB existing construction. Underlayment: In accordance with.FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Installation: Installed with 5-1/8 inch exposure in accordance with the FBC and manufacturer's published installation instructions. The direction of the exposed end shall be away from the prevailing wind. Direction of prevailing wind pun exposure nere--- /Fn]\o Start M5 Figure 1 here 5-1/8"9— exposure iI lot Fastener astenerso Figur2� �.1 /4" Figure 3 Figure 14. Hip&Ridge(Frederick&Joplin) TBP15001.4 FL18355-R4 Page 9 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services.LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES,LLC Vintage®Hip&Ridge Basic Wind Speed(Vu): Max. 194 mph ' (Phillipsburg) Basic Wind Speed(Va,d): Max 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction;Min.7/16 in.OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Installation: Installed with 5 inch exposure in accordance with the FBC and manufacturer's published installation instructions. The direction of the exposed end shall be away from the prevailing wind. Directiofn of prevailing wind -1 exposure Darty /FFn]1] R Start Figure 1 here 5"exposure 1" . � Fastener Fastener G ri5-1/2" "-5-1/2" Figure 2 IN' Figure 3 Figure 15. Vintage@)Hip&Ridge(Phillipsburg) TBP15001.4 FL18355-R4 Page 10 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. TAMKO BUILDING PRODUCTS CREEK Asphalt Shingles TECHNICAL SERvicEs,LLC LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ. 4) Classification to ASTM D 7158 applies to exposure B&C with a building mean roof height of 60-ft or less. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to undedayment application. 6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the deck. 7) Installation of the evaluated products shall comply with this report, the FBC,, and the menufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and code compliant detail shall prevail. 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, Edition(2017)ds evidenced in the referenced documents submitted by the named manufacturer. t%J11111881111 00� R. CENS 2017.09.2 No 74021 11 :31 :41 - '00' .0% STATE OF • 04 Zachary R.Priest,P.E. k\ • 4.0 R I VX- N A N, Florida Registration No.74021 **0; Irp4r;�/0NM-;& Organization No.ANEI 1669 11111111110" CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial Interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity Involved in the approval process of the product. END OF REPORT TBP15001.4 FI-18355-R4 Page 11 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3, The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein.